| Description | The Tomey Refractometer Keratometer and Topographer only in 1 unit senior citizens and children can also get the inspection with out any trouble because they dont have to move the seat for three measurements. | The HUMPHREY 599 is the best combination refractor-keratometer to offer subjective refinement of sphere, cylinder, and axis as well as isolated acuity lines, children’s targets, near testing, and low contrast sensitivity testing. | In recent years, the medical aesthetic industry has seen rapid growth in the number of body sculpting and body contouring procedures performed. The trend is projected to continue growing with the overall market growth of 16.3% year over year through 2020.Sculpting With Open ArmstruSculpt iD offers a unique and personalized approach to improve upper arm contouring and definition. Unlike other devices, there is no placement limitation, it is easy to set up, and fast to treat. Provide your patients improved freedom to open their arms and wear sleeveless shirts with confidence.- Unique approach to treat skin with laxity
- Sculpt challenging areas
- Synchronized treatment zones
- No downtime
| The Cirrus HD-OCT is a non-contact, high resolution tomographic and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures, including cornea, retina, retinal nerve fiber layer, ganglion cell plus inner plexiform layer, macula, and optic nerve head. The Cirrus normative databases are quantitative tools for the comparison of retinal nerve fiber layer thickness, macular thickness, ganglion cell plus inner plexiform layer thickness, and optic nerve head measurements to a database of normal subjects. The Cirrus HD-OCT is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration, and glaucoma. | New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort. | The Zeiss Humphrey Acuitus 5015 Auto Refractor Keratometer offers expanded refracting capabilities, allowing a practice to refract children and elderly patients alike. The Zeiss Acuitus 5015 also allows refraction one-day post operative of IOL and refractive surgery patients. The Zeiss Acuitus 5015 includes a flat color screen display which produces clear and concise images. |
| Content | Tomey RT-7000 Autorefractor Keratometer Topographer
-Three Functions in One Instrument-Easy & Speedy Touch Screen Alignment-6.4 inches color TFT LCD-Dual CCD technology for Refractometry-IOL/ Cataract Mode-New incites for Keratometry KAI, KRI-Auto Alignment / Auto Shot of TopographyCorneal Topography– Auto Alignment / Auto ShotAny one can easily capture measurement with Auto Alignment and Auto Shot. The Measurement variation is significantly reduced no matter what the skill level is of the operator.CL Fitting Simulation-A pseudo-fluorescent pattern of the contact lens selected from the built-in data base can be confirmed and the fitting can be stimulated before the patient wears the trial lens.Corneal Eccentricity Index-The index of CEI (Corneal Eccentricity Index) indicates the ratio of flattering in percentage from the central cornea to the periphery.Three Function in One Instrument– Refractometer Keratometer and Topographer only in 1 unit senior citizens and children can also get the inspection with out any trouble because they don’t have to move the seat for three measurements. Switch from Ref-Kerato Mode to Corneal Topography Mode with only ONE TOUCH. The light come appears with only one button from the measuring head and the Ref-Keratometer is transformed to the topographer.Refractometry– Dual CCD technology for RefractometryTwo CCD cameras are used to capture images for observation and for measurement while providing highly accurate measurement data.Keratometory– New Indices for KeratometryThe Corneal Irregular astigmatism display function is installed to expand the possibility of Keratometer. This is the new function to measure the level of corneal irregular astigmatism which was difficult in the past.SPECIFICATIONSMeasurmentRangesRefraction MeasuremntSphere -25.00D to ±22.00DIVD=12.0mmCylinder 0D to ± 10.00DIVD=12.0mmAxis 0 to 180Corneal Curvature Measurement 5.00mm to 11.00mmMeasurement Zone 3mm R:8.00mmCorneal MappingDisplay Range 9 to 100 D-Normal Mode1.0 to 8.0mm (R:8.00mm)-Special Mode0.9 to 7.0 mm (R:8.00mm)Measurement TimeREF 0.2 SecondsKRT 0.1 SecondsMinimum Pupil Diameter 2.2mmMinimum Measurment Step Refraction MeasurementSphere 0.01DCylinder 0.01DAxis 1Corneal Curvature Measurement 0.01mmPD (Pupil Distance) 50mm to 86mmRecording Built-In Thermal PrinterVertex Distance 0mm, 12.0mm, 13.5mm, 14.0mm, 15.5mm, 16.0mmExterior Output (AN port / 4USB ports)Dimensions Tomey RT-7000 Autorefractor Keratometer TopographerHigh 466mmm or 18 InchesWidth 307mm or 12 InchesDepth 490mm or 19 InchesWeight Approx 20,000Kg / 44.4 PoundsDisplay 6.4 Inches color liquid crystalPower SupplyVoltage AC 100 to 240VFrequency 50/60 HzConsumption Power 120VA to 150VATemperature +10C to + 40CDisplay 30% to 75% | Zeiss Humphrey Hark 599 Autorefractor / Keratometer
The HUMPHREY 599 allows for immediate patient feedback on the prescription and can be linked to the Humphrey Lens Analyzer to allow patients to compare their current RX to the new refraction results. Precise keratometer readings can be instantly obtained for all clinical needs.Fast, accurate and objective measurements with complete printout
Automatic cycle for objective measurements
Complete automatic alignment and tracking
Acuity line isolation
Cylinder and axis refinement
Duochrome target
Jackson Cross Cylinder Test
Near vision testing
Glare testing
Spherical equivalents
PD displayed on printout
Children’s acuity targets
Recall for old and new Rx comparisons
Communicom Interface
Keratometry Reading including average and delta K’s - Fast, accurate and objective measurements with complete printout
- Automatic cycle for objective measurements
- Complete automatic alignment and tracking
- Acuity line isolation
- Cylinder and axis refinement
- Duochrome target
- Jackson Cross Cylinder Test
- Near vision testing
- Spherical equivalents
- PD displayed on printout
- Children’s acuity targets
- Recall for old and new Rx comparisons
- Communicom Interface
- Keratometry Reading including average and delta K’s
Features:Fast, accurate and objective measurements with complete printout
Automatic cycle for objective measurements
Complete automatic alignment and tracking
Acuity line isolation
Cylinder and axis refinement
Duochrome target
Jackson Cross Cylinder Test
Near vision testing
Glare testing
Spherical equivalents
PD displayed on printout
Children’s acuity targets
Recall for old and new Rx comparisons
Communicom Interface
Keratometry Reading including average and delta K’s in the Humphrey HARK 599About us:Zeiss Humphrey Hark 599 Autorefractor / Keratometer
ALT Medical Device is your complete eye care equipment solution. Is comprehensive company offering only high end, quality equipment. As a company, ALT Medical Device combines outstanding business practices with an unparalleled approach to customer service.
We have 100% customer satisfaction by delivering quality equipment and full customer service with every transaction. | 2020 Cutera Trusculpt iD Monopolar RF Body ContouringPersonalized Body Sculpting:truSculpt iD is the latest body sculpting treatment solution from Cutera, providing a personalized, hands-free and hand-held solution to revolutionize your practice. This powerful, non-invasive, Monopolar RF platform tailors to patients’ individual needs and features Real-Time Temperature Control for clinically proven results, safety, and patient experience. truSculpt iD treats the entire fat layer, resulting in an average of 24% fat reduction.It offers unique handpiece and placement location versatility and customized 15-minute protocols to treat a full abdomen or multiple body areas simultaneously.Sculpting With Open ArmstruSculpt iD offers a unique and personalized approach to improve upper arm contouring and definition. Unlike other devices, there is no placement limitation, it is easy to set up, and fast to treat. Provide your patients improved freedom to open their arms and wear sleeveless shirts with confidence.- Unique approach to treat skin with laxity
- Sculpt challenging areas
- Synchronized treatment zones
- No downtime
Sculpting To Get A Leg Up
Thighs are commonly out of proportion with the rest of the lower body causing growing interest in leg sculpting. truSculpt iD offers an individualized and unmatched solution to regain proportion to inner and outer thighs of all shapes and sizes. Give your patients a leg up and the desire to flaunt their youthful shape.- Versatile to treat various tissue densities
- Tailored for areas large and small
- Flexible treatment configurations
- Immediately resume normal activities
truSculpt iD Technology
truSculpt iD provides an innovative RF technology that delivers clinically proven results to expand your body sculpting business. The system versatility allows for customized treatments to multiple body areas simultaneously based on patients need in as little as one 15-minute treatment protocol.Radiofrequency (RF) Energy
truSculpt iD delivers heat to the entire fat layer while maintaining a comfortable skin temperature – optimizing clinical efficacy and maintaining patient comfort. | Zeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD
Accessories- The ZEISS Certified Factory Direct Cirrus 4000 HD-OCT also includes the full Accessory Kit
- External Fixation Light
- Test Eye
- Mini Keyboard
- Optical Mouse
- Dust Cover
- Metric 5A/250v Fuse
- 14 Ft. CAT 5e Network Cable
- USB Cable
- IEC 320 to NEMA 12 inch Power Cable
- IEC 320 39in. Power Cable
- Install Disc including Roxio Basic
- Symbol Sheet
- OCT Primer Guide
- Quick Start Guide
HD-OCT Imaging- Methodology: Spectral Domain OCT
- Optical Source: superluminescent diode (SLD), 840 nm
- Optical Power: < 725 μW at the cornea
- Scan Speed: 27,000 A-scans per second
- A-Scan depth: 2.0 mm (in tissue), 1024 points
- Axial resolution: 5 μm (in tissue)
- Transverse resolution: 15 μm (in tissue)
Fundus Imaging- Methodology: Line scanning ophthalmoscope
- Live Fundus Image: During alignment and during OCT scan
- Optical Source: Superluminescent diode (SLD), 750 nm
- Optical Power: < 1.5 mW at the cornea
- Field of View: 36 degrees W x 30 degrees H
- Frame rate: >20 Hz
- Transverse resolution: 25 μm (in tissue)
Iris Imaging- Methodology: CCD Camera
- Resolution: 1280 x 1024
- Live iris image: During alignment
Electrical, Physical and Environmental- Weight: 38kg (83 lbs)
- Dimensions: 65L x 44W x 53H (cm)
- Fixation: Internal, external
- Internal fixation focus adjustment: -20D to +20D (diopters)
- Input devices: Keyboard, mouse
- Electrical rating (115V) Single Phase, 100/120V~ systems:50-60Hz, 5A
- Fuse rating (115V) T 5A 250V
- Electrical rating (230V) Single Phase, 220/240V~ systems:50-60 Hz, 2.5A
- Fuse rating (230V) Fuse rating: T 5A 250V
- Convenience Receptacle output ratings 115V~, 0.5 A Max, 50-60 Hz
- Temperature (transport and storage) -40º to +70º C
- Relative humidity (transport and storage) 10% to 100%, including condensation
- Atmospheric pressure (transport and storage): 500 hPa to 1060 hPa
- Temperature (operation) +10º to +35º C
- Relative humidity (operation) 30% to 75%, excluding condensation
- Atmospheric Pressure (operation) 700 hPa to 1060 hPa
Computer Zeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD- • High performance multi-core processor
- • Internal storage: > 80,000 scans
- • CD-RW, DVD-ROM drive
- • Integrated 15″ color flat panel display.
The Cirrus HD-OCT is a non-contact, high resolution tomographic and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures, including cornea, retina, retinal nerve fiber layer, ganglion cell plus inner plexiform layer, macula, and optic nerve head. The Cirrus normative databases are quantitative tools for the comparison of retinal nerve fiber layer thickness, macular thickness, ganglion cell plus inner plexiform layer thickness, and optic nerve head measurements to a database of normal subjects. The Cirrus HD-OCT is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration, and glaucoma. | Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
The Laser uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IOptima-518-Classic Active Optical Systems Optima 518 IPL LaserThe Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. | Zeiss Humphrey Acuitus 5015 Autorefractor Keratometer
Autorefractor/Keratometer that
can take a combination of refraction, central and peripheral keratometry. Unit has been tested with a reference eye (not included) and as well with a test subject and
takes accurate OD/OS reading.
Great unit for your optometry practice.
Unit is patient ready. This has just been professionally calibrated by our optical engineer.
Also includes a printed out Acuitus 5015 User manual,power cord.The Zeiss Humphrey Acuitus 5015 Auto Refractor Keratometer offers expanded refracting capabilities, allowing a practice to refract children and elderly patients alike. The Zeiss Acuitus 5015 also allows refraction one-day post operative of IOL and refractive surgery patients. The Zeiss Acuitus 5015 includes a flat color screen display which produces clear and concise images. Additional features on the Zeiss Acuitus 5015 include auto acquisition, auto XYZ, making the measurements easily acquired. Additional benefits on the Zeiss Acuitus 5015 are automatic eye detection, thirty measurements per second, and RS 232 interface. The Zeiss Acuitus 5015 offers a multitude of features in a small compact footprint at an extremely affordable price point.
Zeiss Humphrey Acuitus 5015 Autorefractor Keratometer Autorefractor/Keratometer that
can take a combination of refraction, central and peripheral keratometry. Unit has been tested with a reference eye (not included) and as well with a test subject and
takes accurate OD/OS reading.
Great unit for your optometry practice.
Unit is patient ready. This has just been professionally calibrated by our optical engineer.
Also includes a printed out Acuitus 5015 User manual,power cord.Zeiss Humphrey Acuitus 5015 Autorefractor Keratometer allows refracting one-day postoperative IOL and refractive surgery patients with its expanded refracting capabilitiesZeiss Humphrey Acuitus 5015 is easily acquired because come with Auto Acquisition and Auto XYZ with benefits automatic eye detection, thirty measurements per second, RS 232 interface and affordability.central and peripheral keratometry measurements is another features come with Zeiss Humphrey Acuitus 5015Include:
-Zeiss Humphrey Acuitus 5015
-Boxed calibrated Test Eye
-Printer
-a printed out Acuitus 5015 User Manual |
Reviews
There are no reviews yet.