| Description | In recent years, the medical aesthetic industry has seen rapid growth in the number of body sculpting and body contouring procedures performed. The trend is projected to continue growing with the overall market growth of 16.3% year over year through 2020.Sculpting With Open ArmstruSculpt iD offers a unique and personalized approach to improve upper arm contouring and definition. Unlike other devices, there is no placement limitation, it is easy to set up, and fast to treat. Provide your patients improved freedom to open their arms and wear sleeveless shirts with confidence.- Unique approach to treat skin with laxity
- Sculpt challenging areas
- Synchronized treatment zones
- No downtime
| 2017 Cutera Excel HR 1064 Nd Yag & 755 Alexandrite Hair Removal System, as well as Pigment & Vein Removal & Laser Genesis Skin Rejuvenation;Manufactured: 11/02/2017; Good Cosmetic and Operating Condition, Complete System Refurbishment Performed March 2022; New Replacement Handpiece Installed 03/2022;1064 Nd Yag Pulse Count = 41,588, 755 Alexandrite Pulse Count = 20,591;Includes: New Handpiece, Footswitch, Key, Operator Manual, Operator Eyewear, Patient Eyewear, Interlock. | Superior, Comfortable Laser Hair RemovalLaser Hair Removal – An In-demand Procedureexcel HR combines a high-power 755 nm Alexandrite laser and Cutera’s proven long-pulse 1064 nm Nd:YAG laser for safe, effective high-volume hair removal on all skin types. The combination of wavelengths not only allows for effective hair removal, but is also a solution for epidermal pigmented lesions, vascular lesions and Cutera’s signature laser genesis skin revitalization procedure. | ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER includes: Handpiece, Footswitch, Operator Eyewear, Patient Eyewear, Cart, Key, Operator Manual, ultrasound gel, replacement fuses, replacement filters | Fotona XP Specto, Nd:YAG laser systemFotona’s new XP Spectro laser generator is the one of the latest models of Fotona to hit the market combining the industry recognised gold standard, long=pulse and quasi-continuous wave in a single multi-application laser generator. This combination of technology allows the client to integrate non-ablative aesthetics with surgical techniques. | Includes:
Hand-held 2 MHz 40 cm2
Hand-held 1 MHz 16 cm2Head
Key
Operators Manual |
| Content | 2020 Cutera Trusculpt iD Monopolar RF Body ContouringPersonalized Body Sculpting:truSculpt iD is the latest body sculpting treatment solution from Cutera, providing a personalized, hands-free and hand-held solution to revolutionize your practice. This powerful, non-invasive, Monopolar RF platform tailors to patients’ individual needs and features Real-Time Temperature Control for clinically proven results, safety, and patient experience. truSculpt iD treats the entire fat layer, resulting in an average of 24% fat reduction.It offers unique handpiece and placement location versatility and customized 15-minute protocols to treat a full abdomen or multiple body areas simultaneously.Sculpting With Open ArmstruSculpt iD offers a unique and personalized approach to improve upper arm contouring and definition. Unlike other devices, there is no placement limitation, it is easy to set up, and fast to treat. Provide your patients improved freedom to open their arms and wear sleeveless shirts with confidence.- Unique approach to treat skin with laxity
- Sculpt challenging areas
- Synchronized treatment zones
- No downtime
Sculpting To Get A Leg Up
Thighs are commonly out of proportion with the rest of the lower body causing growing interest in leg sculpting. truSculpt iD offers an individualized and unmatched solution to regain proportion to inner and outer thighs of all shapes and sizes. Give your patients a leg up and the desire to flaunt their youthful shape.- Versatile to treat various tissue densities
- Tailored for areas large and small
- Flexible treatment configurations
- Immediately resume normal activities
truSculpt iD Technology
truSculpt iD provides an innovative RF technology that delivers clinically proven results to expand your body sculpting business. The system versatility allows for customized treatments to multiple body areas simultaneously based on patients need in as little as one 15-minute treatment protocol.Radiofrequency (RF) Energy
truSculpt iD delivers heat to the entire fat layer while maintaining a comfortable skin temperature – optimizing clinical efficacy and maintaining patient comfort. | 2017 Cutera Excel HR 1064nm & 755nm Hair RemovalAlexandrite | | Wavelength | 755 nm | Maximum Energy | 53J | Pulse Duration | 3 ms | Spot Size | 5-18 mm | Repetition Rate | 2 Hz | | | Nd Yag | | Wavelength | 1064 nm | Maximum Energy | 80J | Pulse Duration | 0.1 – 300 ms | Spot Size | 3-12 mm | Repetition Rate | Up to 10 Hz | Cooling | Contact Sapphire | Aiming Beam | 635 nm | Dimensions | 35″ H x 12″ W x 24″ D | Electricial | 200-240 VAC, 50/60 Hz, 20A/30A | | | Cooling | Contact Sapphire | Aiming Beam | 635 nm | Dimensions | 35″ H x 12″ W x 24″ D | Electricial | 200-240 VAC, 50/60 Hz, 20A/30A |
MANUFACTURER NOTES Superior, Comfortable Laser Hair Removal Laser Hair Removal – An In-demand Procedure Global hair removal procedures are growing at a rapid pace. Laser hair removal has been among the top non-surgical procedures according to the American Society of Aesthetic Plastic Surgery and procedure revenue is anticipated to go to $1.35B by 20221. The industry often refers to laser hair removal as a gateway procedure as it offers an entry point into the aesthetic market for patients and practitioners alike. excel HR combines a high-power 755 nm Alexandrite laser and Cutera’s proven long-pulse 1064 nm Nd:YAG laser for safe, effective high-volume hair removal on all skin types. The combination of wavelengths not only allows for effective hair removal, but is also a solution for epidermal pigmented lesions, vascular lesions, and Cutera’s signature laser genesis skin revitalization procedure. excel HR Technology Proven Wavelengths excel HR combines the gold standard laser wavelengths for hair removal. The 755 nm Alexandrite laser is highly absorbed by melanin making it an ideal solution for finer hair on skin types I-III. Because of the high melanin absorption characteristics, it has also been proven to provide long-term results on epidermal pigmented lesions. The 1064 nm Nd:YAG is the safest wavelength for permanent hair reduction on darker skin types and tanned skin. By selecting the appropriate spot size, this laser can also be used for treating facial and leg veins and perform laser genesis procedures. truPulse Delivery with Index Matching Unique to Cutera, the truPulse technology delivers constant, sustained energy throughout the pulse duration to ensure consistent performance and proven clinical outcomes for your patients. excel HR’s index matching delivery results in more efficient coupling of laser energy to target structures. Index matching allows backscattered light to escape, further protecting the epidermis from heat build-up while maintaining treatment efficacy. Superior Contact Cooling excel HR utilizes sapphire contact cooling to provide continuous cooling, maximizing your patients’ comfort and treatment safety. In a patient preference study that measured comfort and satisfaction for laser hair removal, 100% of the patient’s preferred excel HR over a comparable, competitive laser hair removal procedure. 321st Century Laser Hair Removal System Developed by the innovative leader in aesthetic laser technology, excel HR™ laser hair removal system provides advanced premium hair removal solutions for every skin type. Combining a new high-power 755 nm Alexandrite laser, and CUTERA’s proven long-pulse 1064 nm Nd:YAG laser, coupled with the superiority of sapphire contact cooling, excel HR redefines modern laser hair removal. This makes excel HR laser system an effective, safe and comfortable option for laser hair removal for the 21st century. Applications 2017 Cutera Excel HR 1064nm & 755nm Hair Removal - Hair removal
- Benign pigmented lesion removal – All Skin Types I-IV
- Veins, facial
- Veins, leG
- Laser Genesis
| Cutera Excel HR 1064 755 Hair Removal SystemAlexandrite
Wavelength:755 nm
Maximum Energy:53J
Pulse Duration:3 ms
Spot Size:5-18 mm
Repetition Rate:2 HzNd Yag
Wavelength:1064 nm
Maximum Energy:80J
Pulse Duration:0.1 – 300 ms
Spot Size:3-12 mm
Repetition Rate:Up to 10 Hz
Cooling:Contact Sapphire
Aiming Beam:635 nm
Dimensions:35″ H x 12″ W x 24″ D
Electricial:200-240 VAC, 50/60 Hz, 20A/30ACooling:Contact Sapphire
Aiming Beam:635 nm
Dimensions:35″ H x 12″ W x 24″ D
Electricial:200-240 VAC, 50/60 Hz, 20A/30A
Superior, Comfortable Laser Hair Removal
Laser Hair Removal An In-demand Procedure
Global hair removal procedures are growing at a rapid pace. Laser hair removal has been among the top non-surgical procedures according to the American Society of Aesthetic Plastic Surgery and procedure revenue is anticipated to go to $1.35B by 20221. The industry often refers to laser hair removal as a gateway procedure as it offers an entry point into the aesthetic market for patients and practitioners alike.excel HR combines a high-power 755 nm Alexandrite laser and Cuteras proven long-pulse 1064 nm Nd:YAG laser for safe, effective high-volume hair removal on all skin types. The combination of wavelengths not only allows for effective hair removal, but is also a solution for epidermal pigmented lesions, vascular lesions and Cuteras signature laser genesis skin revitalization procedure.excel HR Technology
Proven Wavelengths
excel HR combines the gold standard laser wavelengths for hair removal. The 755 nm Alexandrite laser is highly absorbed by melanin making it an ideal solution for finer hair on skin types I-III. Because of the high melanin absorption characteristics, it has also been proven to provide long-term results on epidermal pigmented lesions.The 1064 nm Nd:YAG is the safest wavelength for permanent hair reduction on darker skin types and tanned skin. By selecting the appropriate spot size, this laser can also be used for treating facial and leg veins and perform laser genesis procedure.truPulse Delivery with Index Matching
Unique to Cutera, the truPulse technology delivers constant, sustained energy throughout the pulse duration to ensure consistent performance and proven clinical outcomes for your patients.excel HRs index matching delivery results in more efficient coupling of laser energy to target structures. Index matching allows backscattered light to escape, further protecting the epidermis from heat build-up while maintaining treatment efficacy.Superior Contact Cooling
excel HR utilizes sapphire contact cooling to provide continuous cooling, maximizing your patients comfort and treatment safety.2 In a patient preference study that measured comfort and satisfaction for laser hair removal, 100% of the patients preferred excel HR over a comparable, competitive laser hair removal procedure.321st Century Laser Hair Removal System
Developed by the innovative leader in aesthetic laser technology, excel HR laser hair removal system provides advanced premium hair removal solutions for every skin type. Combining a new high-power 755 nm Alexandrite laser, and CUTERAs proven long-pulse 1064 nm Nd:YAG laser, coupled with the superiority of sapphire contact cooling, excel HR redefines modern laser hair removal.This makes excel HR laser system an effective, safe and comfortable option for laser hair removal for the 21st century.Applications Cutera Excel HR 1064 755 Hair Removal System
– Hair removal
– Benign pigmented lesion removal
– Veins, facial
– Veins, leg
– Laser Genesis | Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERr uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IActive Optical Systems Optima 518 IPL LaserOptima-518-Classic
The Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERNew Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. | Fotona XP Spectro Laser GeneratorThe Fotona XP Spectro laser offers an industry leading number of treatments from its advanced platform. The Fotona XP Spectro is an ideal choice for new clinics and clinics wishing to advance to a Fotona laser system from their current equipment.Not looking for a new Laser? See our Used-Laser Sales DirectoryThe Fotona XP Spectro laser offers high quality, fast, efficient treatments in the fields of aesthetics and surgery without compromising efficacy.The Fotona XP Spectro laser system has a 35 watt Nd:YAG engine offering different pulse configurations to be able to offer a wide range of applications at no extra cost and no need for additional hand pieces of software.Non-ablative Nd:YAG lasers are a extremely popular choice of laser in an extremely lucrative marketplace. Nd:YAG is proven as a gold standard in hair removal, skin rejuvenation, vascular treatments and much more. Fotona Xp Spectro Nd:YAG laser emits laser energy at 106nm which is proven to minimize discomfort while showing exceptional efficiently and long term results Features:Fotona XP Spectro Laser Generator
* Highest Performance
* Gold standard ND:YAG lasers
* Optional QCW Nd:YG laser
* Multiple applications
* Advanced scanner for greater Precision, Speed and Efficacy
* FRAC3 modality
* User friendly
* Massive earning potential
* Ability to treat all skin types safely and effectively Key Treatments:
* Laser Hair removal
* Rosacea treatments
* Fine wines and Wrinkles
* Laser peels
* Acne treatments
* Laser assisted lipolysis
* Laser assisted Hyperhidrosis
* Onychomycosis
* Skin tightening, tonng and texturing
* Endovenous laser
* Vascular legions
* Thread veins
* FRAC3
* Pigmentation
* Verrucae Technical Data:
* Laser wavelength:1064 nm
* Max. average power:35 W
* Pulsewidth range:PULSE: 0.1 to 50 ms, QCW: 0.1 to 2 ms
* Max. frequency:PULSE: 75 Hz, QCW*: 100 Hz
* Manual spotsizes:2 to 10 mm
* Scanner spotsizes:3 mm*, 6 mm, 9 mm*
* Scanner area:42 cm²
* Beam delivery type:Optical fiber Comes with:
* 5 Years Full Parts and Labour Warranty
* 3 pairs of laser safety goggles
* Standard Nd:YAG hanpiece (R33)
* Training and ongoing support
* Competative rates for clinic consumables | CUTERA TRUSCULPT 3D BODY SCULPTING
Cutera Trusculpt 3D Body Sculpting A New Dimension in Body Sculpting
The rise in popularity of body sculpting can be attributed to two main factors: improved non-surgical treatment results and a population that values investing in themselves.The truSculpt 3D body sculpting device is ideal for patients and practitioners alike. truSculpt 3D is a non-invasive, Monopolar RF system optimized to deliver Targeted, Repeatable and Uniform sculpting of problem areas for a TRU 3D result with no visual downtime. truSculpt 3D takes a multi-dimensional approach to decrease circumference and reduce fat cells, by delivering and holding clinically therapeutic temperatures to the subcutaneous adipose tissue to achieve the clinical efficacy in the shortest possible treatment time with enhanced comfort.Glide Technique
truSculpt 3D glide technique offers consistent results – an average of 24% fat reduction, in a short treatment time over a large treatment zone.1 One 60-minute session provides clinically proven results in the most common treatment areas — the abdomen and flanks.Targeted RF Energy
The truSculpt 3D system uses a low frequency and high conductivity radiofrequency (RF) technology for deep penetration to target the subcutaneous fat layer while maintaining a comfortable surface temperature for patients. Over a 12-week period, the damaged fat cells are slowly broken down and eliminated from the treated subcutaneous adipose tissue2.Repeatable, Proven Outcomes
truSculpt 3D features a proprietary closed-loop temperature feedback mechanism that ensures therapeutic temperatures are met throughout each treatment. This means your patients are comfortable while achieving consistent results.Cutera Trusculpt 3D Body SculptingtruSculpt 3D Handpieces
truSculpt 3D gives you the flexibility to non-invasively address body sculpting concerns. With truSculpt 3D’s two handpiece options (40 cm2 and 16 cm2), you can decrease circumference and eliminate unwanted fat from large and small areas.Hand-held 2 MHz 40 cm2
For use in a gliding motion over fat pockets contained within the small, medium or large treatment templates. Handpiece covers up to a 576 cm2 treatment area on the abdomen and flanks in 60 minutes.Hand-held 1 MHz 16 cm2
For use with a stationary placement over soft tissue in areas that are smaller than the templates. The 16 cm2 handpiece covers petite treatment areas in 5 minutes.Includes:
Hand-held 2 MHz 40 cm2
Hand-held 1 MHz 16 cm2Head
Key
Operators Manual |
Reviews