Confidently measure the human eye with a sophisticated cutting edge technology designed to enhance your ability to diagnose ocular errors faster, easier, and accurately. Ezers ERK-7800 is brilliantly designed technology measures the eye with ultra precision and speed to provide reliable data as the starting point of your refraction and contact lens fitting. It’s compact and modern design enables seamless operation and an enhanced patient comfort, making it the ideal choice in for any ophthalmic practice. Backed by an industry leading 2-years warranty!

Other people want this. 15 people have this in their carts right now.

Description

Ezer ERK-9000 Ezer Autorefractor Keratometer

The ERK-9000 offers your staff the opportunity to gather a wealth of precise information about the patient in one fast and easy test, making the remainder of your exam swift, simple and exact. In addition to the wealth of functions you’d expect from a top-of-the-line autorefractor/keratometer, the ERK-9000 features auto-shoot programming, an illumination mode, IOL mode and so much more.
Features:

– Auto Refractor/Keratometer
– Auto-Shoot Programming
– Simple and Convenient User Environment
– IOL Mode
– Illumination Mode
– Easy Network Capability
– Wide Dioptric Measurement Range
– Accurate Iris and Pupil Measurement
– Ergonomic Joystick
– Motorized Chin Rest
– High-Speed Printer with Auto Paper Cut
– 2-Year Warranty

Includes:Ezer ERK-9000 Ezer Autorefractor Keratometer

– Power Supply Cable
– Model Eye ( S-5.0D or 5.12D or 5.25D, VD=12mm, R–7.95 )
– 2 rolls Printing Paper( Thermal Paper, Size : 57 X 50 mm )
– Dust cover ( Vinyl Cover: Use for long-term storage to prevent dust pollution )
– Operation Manual

The ERK-9000 combines all of the necessary visual pre-testing functions in one smartly designed instrument. Operators can perform refractometry and keratometry alone or simultaneously. The ERK-9000 is also quick. In fact, not even the unwanted effects of patient accommodation will stand in your way thanks to the unit’s valuable built-in auto-fogging mechanism.

Auto-Shoot Programming
Users can program the ERK-9000 to shoot at their preferred mode. One click on the joystick button can take a single measurement, three continuous measurements or five continuous measurements.

Simple and Convenient User Environment
The ERK-9000 features a user-friendly dashboard view. Sharp images with easy-to-understand icons make this 7.0-inch color TFT color touch screen LCD interface enjoyable to work with.
IOLMode
Patients presenting with cataract or IOL won’t present a challenge with the ERK-7800. In fact, now you can gather a wealth of information about natural lens opacity as well as take measurements on patients who have intraocular lens implants.

Reviews

There are no reviews yet.

Be the first to review “Ezer ERK-9000 Ezer Autorefractor Keratometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsEzer ERK-9000 Ezer Autorefractor Keratometer removeNew ZEISS CIRRUS 6000 – 100 kHz OCT Imaging System removeAcuson Cypress PLUS Ultrasound For Sale removeCarl Zeiss Cirrus HD-OCT 4000 removeNidek RS-330 Retina Scan Duo 2 with FAF removeZeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD remove
NameEzer ERK-9000 Ezer Autorefractor Keratometer removeNew ZEISS CIRRUS 6000 – 100 kHz OCT Imaging System removeAcuson Cypress PLUS Ultrasound For Sale removeCarl Zeiss Cirrus HD-OCT 4000 removeNidek RS-330 Retina Scan Duo 2 with FAF removeZeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD remove
Image
SKU
Rating
Price $8,550.00 $7,200.00 $7,200.00 $3,980.00 $3,150.00 $4,500.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

DescriptionConfidently measure the human eye with a sophisticated cutting edge technology designed to enhance your ability to diagnose ocular errors faster, easier, and accurately. Ezers ERK-7800 is brilliantly designed technology measures the eye with ultra precision and speed to provide reliable data as the starting point of your refraction and contact lens fitting. It’s compact and modern design enables seamless operation and an enhanced patient comfort, making it the ideal choice in for any ophthalmic practice. Backed by an industry leading 2-years warranty!
Performance OCT. 100,000 scans per second to power your practice.
CIRRUS  6000 is the next-generation OCT from ZEISS, delivering high-speed image capture with HD imaging detail and a wider field of view so you can make more informed decisions and spend more time with the patients who need it.Learn how you can maximize patient throughput and practice efficiency with ZEISS CIRRUS 6000.
Acuson Cypress cardiovascular system PLUS delivers advanced ergonomics and superior performance in a highly portable package. TheCypress System PLUSis a highly miniaturized, all digital, phased array echocardiography system that provides complete studies and outstanding images – even on patients who are difficult to image.
CIRRUS 4000 delivers high-speed image capture with HD imaging detail and a wider field of view so you can make more informed decisions and spend more time with the patients who need it.
The Nidek RS-330 OCT is a combination of a High-Definition OCT and fundus camera. Optional delivery with FAF (Auto-fluorescence function)
The Cirrus HD-OCT is a non-contact, high resolution tomographic and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures, including cornea, retina, retinal nerve fiber layer, ganglion cell plus inner plexiform layer, macula, and optic nerve head. The Cirrus normative databases are quantitative tools for the comparison of retinal nerve fiber layer thickness, macular thickness, ganglion cell plus inner plexiform layer thickness, and optic nerve head measurements to a database of normal subjects. The Cirrus HD-OCT is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration, and glaucoma.
ContentEzer ERK-9000 Ezer Autorefractor KeratometerThe ERK-9000 offers your staff the opportunity to gather a wealth of precise information about the patient in one fast and easy test, making the remainder of your exam swift, simple and exact. In addition to the wealth of functions you’d expect from a top-of-the-line autorefractor/keratometer, the ERK-9000 features auto-shoot programming, an illumination mode, IOL mode and so much more. Features:– Auto Refractor/Keratometer – Auto-Shoot Programming – Simple and Convenient User Environment – IOL Mode – Illumination Mode – Easy Network Capability – Wide Dioptric Measurement Range – Accurate Iris and Pupil Measurement – Ergonomic Joystick – Motorized Chin Rest – High-Speed Printer with Auto Paper Cut – 2-Year WarrantyIncludes:Ezer ERK-9000 Ezer Autorefractor Keratometer– Power Supply Cable – Model Eye ( S-5.0D or 5.12D or 5.25D, VD=12mm, R–7.95 ) – 2 rolls Printing Paper( Thermal Paper, Size : 57 X 50 mm ) – Dust cover ( Vinyl Cover: Use for long-term storage to prevent dust pollution ) – Operation ManualThe ERK-9000 combines all of the necessary visual pre-testing functions in one smartly designed instrument. Operators can perform refractometry and keratometry alone or simultaneously. The ERK-9000 is also quick. In fact, not even the unwanted effects of patient accommodation will stand in your way thanks to the unit’s valuable built-in auto-fogging mechanism.Auto-Shoot Programming Users can program the ERK-9000 to shoot at their preferred mode. One click on the joystick button can take a single measurement, three continuous measurements or five continuous measurements.Simple and Convenient User Environment The ERK-9000 features a user-friendly dashboard view. Sharp images with easy-to-understand icons make this 7.0-inch color TFT color touch screen LCD interface enjoyable to work with. IOLMode Patients presenting with cataract or IOL won’t present a challenge with the ERK-7800. In fact, now you can gather a wealth of information about natural lens opacity as well as take measurements on patients who have intraocular lens implants.New ZEISS CIRRUS 6000 – 100 kHz OCT Imaging System
Faster, wider with a new level of detail
At 100,000 scans per second, ZEISS CIRRUS 6000 enables clinicians to image a larger field of view up to 12mm in a single scan. It also captures high-defintion (HD) OCT and OCT Angiography (OCTA) scans, revealing the finer microvascular details of the retina and providing more insight into your patient’s condition.
Making the revolutionary, routine.ZEISS AngioPlex OCT Angiography New ZEISS CIRRUS 6000 – 100 kHz OCT Imaging System
AngioPlexOCT Angiography from ZEISS ushers in a new era of eye care with non-invasive imaging of retinal microvasculature—taking glaucoma and retinal disease management and treatment planning to the next level. By offering the industry’s most comprehensive tools for assessing and analyzing a range of pathologies, ZEISS provides a complete OCT Angiography (OCTA) solution.
CIRRUS 6000 is the latest addition to an already robust portfolio of OCT devices that are designed to meet the needs of all types and levels of practices and/or clinicians. It offers customers high-speed and high-throughput to help manage their large patient volume faster, all while improving imaging and image quality.
“This system was designed with the patient in mind, enabling doctors to continue accessing their patient data from CIRRUS devices that are crucial to effective long-term patient care,” said Jim Mazzo, Global President of Ophthalmic Devices at Carl Zeiss Meditec. “We are committed to our customers and believe this will become an essential asset to their practice.”The 100kHz speed of the CIRRUS 6000 allows clinicians to scan patients faster, with increased efficiency and improved imaging detail. Additional features include:
  • Wider and deeper OCT/OCTA scans with 12x12mm OCTA and B-scan depth up to 2.9mm
  • HD AngioPlex scan is a new scan type that provides more detail
  • New workflow protocols to aid in increasing efficiency
  • Patient-friendly “Wellness report” to help educate the patient
According to retina and vitreoretinal physician and surgeon Gregg T. Kokame, MD, of Retina Consultants of Hawaii, the new ZEISS CIRRUS 6000 is extremely fast and impressive. “With the new scan acquisition time of 100,000 per second I can scan and assess my patients much quicker, giving me the details I need with every image,” says Kokame.“ZEISS is dedicated to advancing eye care through development of new and innovative solutions, like the CIRRUS 6000,” said Dr. Ludwin Monz, President and CEO of Carl Zeiss Meditec AG. “With our comprehensive diagnostics portfolio, we will continue to create better vision standards to benefit patients today and in the future.”
Acuson Cypress PLUS UltrasoundAcuson Cypress cardiovascular system PLUS delivers advanced ergonomics and superior performance in a highly portable package. TheCypress System PLUSis a highly miniaturized, all digital, phased array echocardiography system that provides complete studies and outstanding images – even on patients who are difficult to image.The Cypress PLUS transitions easily from your small private office or hospital echo lab to the operating theatre or your patient’s bedside. It’s ultrasound where you need it.The Cypress PLUS delivers high performance in a complete range of cardiovascular capabilities.Designed with advanced ergonomics in mind, the Cypress system PLUS streamlines your workflow and increases your productivity.If you already own a Cypress system, keeping technologically current is simple with the Cypress Upgrade program.The Cypress system is the smallest, lightest, high performance, phased array echo system ever built. Weighing in at just 19 pounds, with digital storage capacity for over 100 studies and network capabilities to send studies from remote locations, clinicians can perform complete echocardiography studies from almost anywhere. TheCypress system was designed for portability, durability and reliability, and to withstand the rigors of constant transportation. Internal system interconnects are minimized. Key components are shock mounted and the entire system sits inside a robust chassis. From hospital to office or from airplane to mountain village, the Cypress system will perform.Full Range of Capabilities The Cypress system is a complete, full-featured echo cardiography system that provides complete studies and outstanding image quality even on the most difficult to image patients. It offers a full range of features including:Acuson Cypress PLUS Ultrasound– 2D with Harmonics – Patient Report with audio capture – M-Mode – Embedded DICOM conformance – Color PW and CW Doppler – High frame rate color flow imaging – Stress echo – Network output – Vascular imaging – Comprehensive calculations package – Contrast agent imaging – USB peripheral support (PC printer connectivity)Physical Characteristics • Single unit houses ultrasound system with control panel, flat panel display and MO drive • Weight: 8.6 Kg (19 pounds) • Height: 35.6 cm (14 in) • Width: 40.6 cm (16 in) • Depth: 20.3 cm (8 in) – with keyboard folded up 34.3 cm (13.5 in) – with keyboard down • Heat dissipation: 490 BTU/hour (nominal)User Interface • Fold-up control panel for portability • Direct access to system functions through dedicated keyboard controls and multifunctional soft keys • Easy-access main controls, including multifunctional trackball, enter and select keys, for minimum hand movement while controlling the system • Adjustable trackball speed • Functional grouping of keys, rotational knobs, switches and sliding TGC controls for direct access to critical functions • Tactile feedback on control activation • Backlighting of control panel labels • Mode-dependent soft keys • User-interface tools • Pre-defined and user-entered labeling textMonitor • 10.4 inch/26.4 cm flat panel active matrix display screen • Protective anti-glare, anti-reflective lensHard Drive • Internal hard drive for image and data storage • Internal storage of approximately 50 patient studies (25 – 30 loops per study)Transducer Ports • One transducer connector (type IEC601BF)Operating/Display Modes • 2-D, fundamental and harmonic imaging • Color Doppler Velocity (CDV) • Color Doppler Energy (CDE) • M-mode, vertical split screen display with 2-D • Pulsed Wave (PW) Spectral Doppler • Continuous Wave (CW) Spectral Doppler • Duplex Doppler (combined 2-D and Spectral Doppler display)2D Calipers – Generic Measurements and Calculations • Measurements and calculations in 2D, M-mode, color Doppler, PW and CW spectral Doppler modes • Basic measurements and report calculations • Comprehensive patient calculations report • On-screen “mini-reports” • Complete or configured patient report • Cardiac package • Carotid package • Arterial package • Venous package • Abdominal package • User configurable Sites • Selectable menu position • Four cursor types • Angle correction • Distance • Area • Slope • Time • Velocity • Velocity/pressure • Mean velocity/pressure gradient • Velocity Time Integral • Pressure halftime • Continuity Equation • Ejection Fraction • Left Ventricular Volumes, including End-Systolic and End-Diastolic volumes • Cardiac output • Cardiac index • Fractional area changeCine Review • 2D Cine memory up to 15 seconds of history • Color Doppler cine memory up to 15 seconds of history • M-mode strip cine along with PW and CW Doppler mode • strip cine memory determined by sweep speed (selectable by the user) 10, 20, 30 or 40 secondsTransducer Technology • 3V2c: 2-4 MHz wideband phased array • 7V3c: 3-7 MHz wideband phased array • 7L3: 5-7 MHz wideband linear array (Vascular) • 4C1: 2-4 MHz wideband curved linear array (Abdominal) • V5Ms: 3-6 MHz wideband phased array (micro-pinless (MP) connector)

Carl Zeiss Cirrus HD-OCT 4000

The Cirrus HD-OCT is a non-contact, high resolution tomographic and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures, including cornea, retina, retinal nerve fiber layer, ganglion cell plus inner plexiform layer, macula, and optic nerve head. The Cirrus normative databases are quantitative tools for the comparison of retinal nerve fiber layer thickness, macular thickness, ganglion cell plus inner plexiform layer thickness, and optic nerve head measurements to a database of normal subjects. The Cirrus HD-OCT is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration, and glaucoma.The ZEISS Certified Factory Direct Cirrus 4000 HD-OCT also includes the full Accessory Kit External Fixation Light Test Eye Mini Keyboard Optical Mouse Dust Cover Metric 5A/250v Fuse 14 Ft. CAT 5e Network Cable USB Cable IEC 320 to NEMA 12 inch Power Cable IEC 320 39in. Power Cable Install Disc including Roxio Basic Symbol Sheet OCT Primer Guide Quick Start GuideHD-OCT ImagingMethodology: Spectral Domain OCT Optical Source: superluminescent diode (SLD), 840 nm Optical Power: < 725 μW at the cornea Scan Speed: 27,000 A-scans per second A-Scan depth: 2.0 mm (in tissue), 1024 points Axial resolution: 5 μm (in tissue) Transverse resolution: 15 μm (in tissue)Zeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD Fundus ImagingMethodology: Line scanning ophthalmoscope Live Fundus Image: During alignment and during OCT scan Optical Source: Superluminescent diode (SLD), 750 nm Optical Power: < 1.5 mW at the cornea Field of View: 36 degrees W x 30 degrees H Frame rate: >20 Hz Transverse resolution: 25 μm (in tissue)Carl Zeiss Cirrus HD-OCT 4000 Iris ImagingMethodology: CCD Camera Resolution: 1280 x 1024 Live iris image: During alignmentElectrical, Physical and EnvironmentalWeight: 38kg (83 lbs) Dimensions: 65L x 44W x 53H (cm) Fixation: Internal, external Internal fixation focus adjustment: -20D to +20D (diopters) Input devices: Keyboard, mouse Electrical rating (115V) Single Phase, 100/120V~ systems:50-60Hz, 5A Fuse rating (115V) T 5A 250V Electrical rating (230V) Single Phase, 220/240V~ systems:50-60 Hz, 2.5A Fuse rating (230V) Fuse rating: T 5A 250V Convenience Receptacle output ratings 115V~, 0.5 A Max, 50-60 Hz Temperature (transport and storage) -40º to +70º C Relative humidity (transport and storage) 10% to 100%, including condensation Atmospheric pressure (transport and storage): 500 hPa to 1060 hPa Temperature (operation) +10º to +35º C Relative humidity (operation) 30% to 75%, excluding condensation Atmospheric Pressure (operation) 700 hPa to 1060 hPa

Nidek RS-330 Retina Scan Duo 2 with FAF

The Retina Scan Duo 2 is a combined OCT and fundus camera system that incorporates new features enhancing screening and clinical efficiency in addition to user-friendly features that were incorporated from the previous model.FEATURES : Nidek RS-330 Retina Scan Duo 2 with FAF
  • Fundus image acquisition with macula and disc capture in one image on OCT
  • Combined diagnosis of macular and disc pathologies
  • Wide area scan (12 x 9 mm) Wide area normative database (macula: 9 x 9 mm, disc: 6 x 6 mm): A 12 x 9 mm wide area image can be acquired. The retina map captures both the macula and disc in a single shot. The normative database provides a wide area color-coded map comparing the patient’s macular thickness to a population of normal eyes.
  • Denoising technique with deep learning: A new image enhancement technique using deep learning automatically displays a denoised image once B-scan acquisition is complete. With deep learning of a large data set of images averaged from 120 images, this denoising technique provides high definition images comparable to a multiple-image-averaging technique. The denoising function generates high definition images from a single frame while decreasing image acquisition time and increasing patient comfort.
  • Quick acquisition of high definition B-scan images from a single-frame image
  • Fundus autofluorescence (FAF): The FAF function is an advanced screening feature that allows non-invasive evaluation of the RPE without contrast dye. *Available for the FAF model
Nidek RS-330 Retina Scan Duo 2– Easy operation with 3-D auto tracking, auto shot, and user friendly interface – High definition images – Wide area scan (12 x 9 mm) / Wide area normative database (9 x 9 mm) – Multiple OCT scan patterns – Value added features – Various reports
Nidek High speed image capture OCT images are captured at scan speeds of 70,000 A-scans/s which is 32% faster than acquisition with the Retina Scan Duo™ using Regular OCT sensitivity*Wide area scan (12 x 9 mm) Wide area normative database (macula: 9 x 9 mm, disc: 6 x 6 mm) A 12 x 9 mm wide area image can be acquired. The retina map captures both the macula and disc in a single shot. The normative database provides a wide area color-coded map comparing the patient’s macular thickness to a population of normal eyes.Denoising using deep learning A new image enhancement technique using deep learning automatically displays a denoised image once B-scan acquisition is complete. With deep learning of a large data set of images averaged from 120 images, this denoising technique provides high definition images comparable to a multiple-image-averaging technique. The denoising function generates high definition images from a single frame while decreasing image acquisition time and increasing patient comfort

Zeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD

Accessories
  •     The ZEISS Certified Factory Direct Cirrus 4000 HD-OCT also includes the full Accessory Kit
  •     External Fixation Light
  •     Test Eye
  •     Mini Keyboard
  •     Optical Mouse
  •     Dust Cover
  •     Metric 5A/250v Fuse
  •     14 Ft. CAT 5e Network Cable
  •     USB Cable
  •     IEC 320 to NEMA 12 inch Power Cable
  •     IEC 320 39in. Power Cable
  •     Install Disc including Roxio Basic
  •     Symbol Sheet
  •     OCT Primer Guide
  •     Quick Start Guide
HD-OCT Imaging
  • Methodology: Spectral Domain OCT
  • Optical Source: superluminescent diode (SLD), 840 nm
  • Optical Power: < 725 μW at the cornea
  • Scan Speed: 27,000 A-scans per second
  • A-Scan depth: 2.0 mm (in tissue), 1024 points
  • Axial resolution: 5 μm (in tissue)
  • Transverse resolution: 15 μm (in tissue)
Fundus Imaging
  • Methodology: Line scanning ophthalmoscope
  • Live Fundus Image: During alignment and during OCT scan
  • Optical Source: Superluminescent diode (SLD), 750 nm
  • Optical Power: < 1.5 mW at the cornea
  • Field of View: 36 degrees W x 30 degrees H
  • Frame rate: >20 Hz
  • Transverse resolution: 25 μm (in tissue)
Iris Imaging
  • Methodology: CCD Camera
  • Resolution: 1280 x 1024
  • Live iris image: During alignment
Electrical, Physical and Environmental
  • Weight: 38kg (83 lbs)
  • Dimensions: 65L x 44W x 53H (cm)
  • Fixation: Internal, external
  • Internal fixation focus adjustment: -20D to +20D (diopters)
  • Input devices: Keyboard, mouse
  • Electrical rating (115V) Single Phase, 100/120V~ systems:50-60Hz, 5A
  • Fuse rating (115V) T 5A 250V
  • Electrical rating (230V) Single Phase, 220/240V~ systems:50-60 Hz, 2.5A
  • Fuse rating (230V) Fuse rating: T 5A 250V
  • Convenience Receptacle output ratings 115V~, 0.5 A Max, 50-60 Hz
  • Temperature (transport and storage) -40º to +70º C
  • Relative humidity (transport and storage) 10% to 100%, including condensation
  • Atmospheric pressure (transport and storage): 500 hPa to 1060 hPa
  • Temperature (operation) +10º to +35º C
  • Relative humidity (operation) 30% to 75%, excluding condensation
  • Atmospheric Pressure (operation) 700 hPa to 1060 hPa
Computer Zeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD
  • • High performance multi-core processor
  • • Internal storage: > 80,000 scans
  • • CD-RW, DVD-ROM drive
  • • Integrated 15″ color flat panel display.
The Cirrus HD-OCT is a non-contact, high resolution tomographic and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures, including cornea, retina, retinal nerve fiber layer, ganglion cell plus inner plexiform layer, macula, and optic nerve head. The Cirrus normative databases are quantitative tools for the comparison of retinal nerve fiber layer thickness, macular thickness, ganglion cell plus inner plexiform layer thickness, and optic nerve head measurements to a database of normal subjects. The Cirrus HD-OCT is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration, and glaucoma.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: Ezer ERK-9000 Ezer Autorefractor Keratometer $8,550.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Shopping cart close