Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD

$6,950.00

CIRRUS HD-OCT 5000 is configured with the highest resolution visualization capabilities and sophisticated clinical applications such as Advanced RPE analysis to track retinal pigment epithelial integrity and Ganglion Cell Analysis to assess glaucomatous loss in the macula that may not be evident in the peripapillary region. The new FastTrac  retinal tracking reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning. This feature enables the highest resolution B-Scans to be captured in identical locations from visit to visit providing precise assessment of change in targeted pathologies.

Other people want this. 15 people have this in their carts right now.

Description

Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD

Advancing Smart OCT

for Anterior Segment, Glaucoma and Retina
  • Anterior Segment Premier Module
  • PanoMap Wide-Field Display
  • Smart HD Scans
  • En face report
Measurement centering with Foveafinder

Visualization at the speed of CIRRUS

Analyzing a single pathology from multiple views provides comprehensive insight and analysis of the clinical situation. How this helps you:

  • Spot small areas of pathology. Tightly spaced B-scans, (either 30 or 47 μm apart), in the cube ensure that small areas of pathology are imaged. For reference, a human hair is about 40-120 μm in diameter.
  • Visualize the fovea. Scans that are spaced further apart than in the CIRRUS cube may miss the central fovea.
  • Fuel for analysis. Millions of data points from the cube are fed into the Zeiss proprietary algorithms for accurate segmentation, reproducible measurements and registration for change analysis.
  • Take the pressure off the operator. As long as the scan is placed in the vicinity of the fovea or optic nerve, the software automatically centers the measurements after the capture.
  • See the tissue from different perspectives. View the cube data from all angles, with 3D rendering, OCT fundus images and Advanced Visualization™.
  • Future ready. Previously captured CIRRUS cubes can be analyzed using new analyses.

 

Measurement centering with Foveafinder

Tracking at the speed of CIRRUS

FastTrac™ reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning
With FastTrac, scan at the highest resolution at the same location at each visit.

Watch video
Measurement centering with Foveafinder

Assessment at the speed of CIRRUS

Measurement centering with FoveaFinder and AutoCenter

On the macula, the unique FoveaFinder technology ensures the ETDRS and ganglion cell plus inner plexiform layer measurement frameworks are centered on the fovea.

AutoCenter™ function automatically centers the 3.4 mm diameter peripapillary RNFL calculation circle around the disc for precise placement and repeatable registration. The placement of the circle is not operator dependent. Accuracy, registration and reproducibility are assured.

Measurement centering with Foveafinder

Manage at the speed of CIRRUS Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD

Guided Progression Analysis (GPA™) for Assessing RNFL and Optic Disc Change

GPA™ compares RNFL thickness and optic disc measurements over time and determines if statistically significant change has occurred.

Focal Progression Analysis – Up to 6 progression maps are compared to two baselines. Areas of statistically significant change are color-coded yellow when first noted and then red when the change is sustained over consecutive visits.
Trend Analysis with Rate of Change – RNFL thickness values are plotted over time. Trends are calculated and confidence intervals are shaded when rate of change is statistically significant.

 

Reviews

There are no reviews yet.

Be the first to review “Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsCarl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD removeZeiss Humphrey Hark 599 Autorefractor / Keratometer For Sale removeCutera Excel HR 1064 755 Hair Removal System For Sale removeNew ZEISS CIRRUS 6000 – 100 kHz OCT Imaging System removeBison Dual ACCENTO Nd YAG Laser For Sale removeNidek OPD-Scan III Corneal Analyzer For Sale remove
NameCarl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD removeZeiss Humphrey Hark 599 Autorefractor / Keratometer For Sale removeCutera Excel HR 1064 755 Hair Removal System For Sale removeNew ZEISS CIRRUS 6000 – 100 kHz OCT Imaging System removeBison Dual ACCENTO Nd YAG Laser For Sale removeNidek OPD-Scan III Corneal Analyzer For Sale remove
Image
SKU
Rating
Price $6,950.00 $2,500.00 $9,800.00 $7,200.00 $9,800.00 $5,650.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

DescriptionCIRRUS HD-OCT 5000 is configured with the highest resolution visualization capabilities and sophisticated clinical applications such as Advanced RPE analysis to track retinal pigment epithelial integrity and Ganglion Cell Analysis to assess glaucomatous loss in the macula that may not be evident in the peripapillary region. The new FastTrac  retinal tracking reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning. This feature enables the highest resolution B-Scans to be captured in identical locations from visit to visit providing precise assessment of change in targeted pathologies.

The HUMPHREY 599 is the best combination refractor-keratometer to offer subjective refinement of sphere, cylinder, and axis as well as isolated acuity lines, children’s targets, near testing, and low contrast sensitivity testing.

Superior, Comfortable Laser Hair RemovalLaser Hair Removal – An In-demand Procedureexcel HR combines a high-power 755 nm Alexandrite laser and Cutera’s proven long-pulse 1064 nm Nd:YAG laser for safe, effective high-volume hair removal on all skin types. The combination of wavelengths not only allows for effective hair removal, but is also a solution for epidermal pigmented lesions, vascular lesions and Cutera’s signature laser genesis skin revitalization procedure.
Performance OCT. 100,000 scans per second to power your practice.
CIRRUS  6000 is the next-generation OCT from ZEISS, delivering high-speed image capture with HD imaging detail and a wider field of view so you can make more informed decisions and spend more time with the patients who need it.Learn how you can maximize patient throughput and practice efficiency with ZEISS CIRRUS 6000.
Bison Dual ACCENTO is the unique device combination with Alexandrite laser (755nm) and Nd:YAG laser (1064nm Long pulse) The combination of two different wavelengths makes DUAL ACCENTO a highly effective system for hair removal and pigmented lesions treatment. The 755nm penetrates deep into the skin and perfectly targets hair the follicle and absorbs melanin.The OPD-Scan III is an automated 5 in 1 instrument that combines topography, wavefront, autorefraction, keratometry, and pupillometry — allowing accurate and reliable analysis of corneal aberration.
ContentCarl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD

Advancing Smart OCT

for Anterior Segment, Glaucoma and Retina
  • Anterior Segment Premier Module
  • PanoMap Wide-Field Display
  • Smart HD Scans
  • En face report
Measurement centering with Foveafinder

Visualization at the speed of CIRRUS

Analyzing a single pathology from multiple views provides comprehensive insight and analysis of the clinical situation. How this helps you:
  • Spot small areas of pathology. Tightly spaced B-scans, (either 30 or 47 μm apart), in the cube ensure that small areas of pathology are imaged. For reference, a human hair is about 40-120 μm in diameter.
  • Visualize the fovea. Scans that are spaced further apart than in the CIRRUS cube may miss the central fovea.
  • Fuel for analysis. Millions of data points from the cube are fed into the Zeiss proprietary algorithms for accurate segmentation, reproducible measurements and registration for change analysis.
  • Take the pressure off the operator. As long as the scan is placed in the vicinity of the fovea or optic nerve, the software automatically centers the measurements after the capture.
  • See the tissue from different perspectives. View the cube data from all angles, with 3D rendering, OCT fundus images and Advanced Visualization™.
  • Future ready. Previously captured CIRRUS cubes can be analyzed using new analyses.
 
Measurement centering with Foveafinder

Tracking at the speed of CIRRUS

FastTrac™ reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning With FastTrac, scan at the highest resolution at the same location at each visit.
Watch video
Measurement centering with Foveafinder

Assessment at the speed of CIRRUS

Measurement centering with FoveaFinder and AutoCenter
On the macula, the unique FoveaFinder technology ensures the ETDRS and ganglion cell plus inner plexiform layer measurement frameworks are centered on the fovea.AutoCenter™ function automatically centers the 3.4 mm diameter peripapillary RNFL calculation circle around the disc for precise placement and repeatable registration. The placement of the circle is not operator dependent. Accuracy, registration and reproducibility are assured.
Measurement centering with Foveafinder

Manage at the speed of CIRRUS Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD

Guided Progression Analysis (GPA™) for Assessing RNFL and Optic Disc Change
GPA™ compares RNFL thickness and optic disc measurements over time and determines if statistically significant change has occurred.Focal Progression Analysis – Up to 6 progression maps are compared to two baselines. Areas of statistically significant change are color-coded yellow when first noted and then red when the change is sustained over consecutive visits. Trend Analysis with Rate of Change – RNFL thickness values are plotted over time. Trends are calculated and confidence intervals are shaded when rate of change is statistically significant.
 

Zeiss Humphrey Hark 599 Autorefractor / Keratometer

The HUMPHREY 599 allows for immediate patient feedback on the prescription and can be linked to the Humphrey Lens Analyzer to allow patients to compare their current RX to the new refraction results. Precise keratometer readings can be instantly obtained for all clinical needs.Fast, accurate and objective measurements with complete printout Automatic cycle for objective measurements Complete automatic alignment and tracking Acuity line isolation Cylinder and axis refinement Duochrome target Jackson Cross Cylinder Test Near vision testing Glare testing Spherical equivalents PD displayed on printout Children’s acuity targets Recall for old and new Rx comparisons Communicom Interface Keratometry Reading including average and delta K’s 
  • Fast, accurate and objective measurements with complete printout
  • Automatic cycle for objective measurements
  • Complete automatic alignment and tracking
  • Acuity line isolation
  • Cylinder and axis refinement
  • Duochrome target
  • Jackson Cross Cylinder Test
  • Near vision testing
  • Spherical equivalents
  • PD displayed on printout
  • Children’s acuity targets
  • Recall for old and new Rx comparisons
  • Communicom Interface
  • Keratometry Reading including average and delta K’s
Features:Fast, accurate and objective measurements with complete printout Automatic cycle for objective measurements Complete automatic alignment and tracking Acuity line isolation Cylinder and axis refinement Duochrome target Jackson Cross Cylinder Test Near vision testing Glare testing Spherical equivalents PD displayed on printout Children’s acuity targets Recall for old and new Rx comparisons Communicom Interface Keratometry Reading including average and delta K’s in the Humphrey HARK 599About us:Zeiss Humphrey Hark 599 Autorefractor / Keratometer ALT Medical Device is your complete eye care equipment solution. Is comprehensive company offering only high end, quality equipment. As a company, ALT Medical Device combines outstanding business practices with an unparalleled approach to customer service. We have 100% customer satisfaction by delivering quality equipment and full customer service with every transaction.
Cutera Excel HR 1064 755 Hair Removal SystemAlexandrite Wavelength:755 nm Maximum Energy:53J Pulse Duration:3 ms Spot Size:5-18 mm Repetition Rate:2 HzNd Yag Wavelength:1064 nm Maximum Energy:80J Pulse Duration:0.1 – 300 ms Spot Size:3-12 mm Repetition Rate:Up to 10 Hz Cooling:Contact Sapphire Aiming Beam:635 nm Dimensions:35″ H x 12″ W x 24″ D Electricial:200-240 VAC, 50/60 Hz, 20A/30ACooling:Contact Sapphire Aiming Beam:635 nm Dimensions:35″ H x 12″ W x 24″ D Electricial:200-240 VAC, 50/60 Hz, 20A/30A Superior, Comfortable Laser Hair Removal Laser Hair Removal  An In-demand Procedure Global hair removal procedures are growing at a rapid pace. Laser hair removal has been among the top non-surgical procedures according to the American Society of Aesthetic Plastic Surgery and procedure revenue is anticipated to go to $1.35B by 20221. The industry often refers to laser hair removal as a gateway procedure as it offers an entry point into the aesthetic market for patients and practitioners alike.excel HR combines a high-power 755 nm Alexandrite laser and Cuteras proven long-pulse 1064 nm Nd:YAG laser for safe, effective high-volume hair removal on all skin types. The combination of wavelengths not only allows for effective hair removal, but is also a solution for epidermal pigmented lesions, vascular lesions and Cuteras signature laser genesis skin revitalization procedure.excel HR Technology Proven Wavelengths excel HR combines the gold standard laser wavelengths for hair removal. The 755 nm Alexandrite laser is highly absorbed by melanin making it an ideal solution for finer hair on skin types I-III. Because of the high melanin absorption characteristics, it has also been proven to provide long-term results on epidermal pigmented lesions.The 1064 nm Nd:YAG is the safest wavelength for permanent hair reduction on darker skin types and tanned skin. By selecting the appropriate spot size, this laser can also be used for treating facial and leg veins and perform laser genesis procedure.truPulse Delivery with Index Matching Unique to Cutera, the truPulse technology delivers constant, sustained energy throughout the pulse duration to ensure consistent performance and proven clinical outcomes for your patients.excel HRs index matching delivery results in more efficient coupling of laser energy to target structures. Index matching allows backscattered light to escape, further protecting the epidermis from heat build-up while maintaining treatment efficacy.Superior Contact Cooling excel HR utilizes sapphire contact cooling to provide continuous cooling, maximizing your patients comfort and treatment safety.2 In a patient preference study that measured comfort and satisfaction for laser hair removal, 100% of the patients preferred excel HR over a comparable, competitive laser hair removal procedure.321st Century Laser Hair Removal System Developed by the innovative leader in aesthetic laser technology, excel HR laser hair removal system provides advanced premium hair removal solutions for every skin type. Combining a new high-power 755 nm Alexandrite laser, and CUTERAs proven long-pulse 1064 nm Nd:YAG laser, coupled with the superiority of sapphire contact cooling, excel HR redefines modern laser hair removal.This makes excel HR laser system an effective, safe and comfortable option for laser hair removal for the 21st century.Applications Cutera Excel HR 1064 755 Hair Removal System – Hair removal – Benign pigmented lesion removal – Veins, facial – Veins, leg – Laser GenesisNew ZEISS CIRRUS 6000 – 100 kHz OCT Imaging System
Faster, wider with a new level of detail
At 100,000 scans per second, ZEISS CIRRUS 6000 enables clinicians to image a larger field of view up to 12mm in a single scan. It also captures high-defintion (HD) OCT and OCT Angiography (OCTA) scans, revealing the finer microvascular details of the retina and providing more insight into your patient’s condition.
Making the revolutionary, routine.ZEISS AngioPlex OCT Angiography New ZEISS CIRRUS 6000 – 100 kHz OCT Imaging System
AngioPlexOCT Angiography from ZEISS ushers in a new era of eye care with non-invasive imaging of retinal microvasculature—taking glaucoma and retinal disease management and treatment planning to the next level. By offering the industry’s most comprehensive tools for assessing and analyzing a range of pathologies, ZEISS provides a complete OCT Angiography (OCTA) solution.
CIRRUS 6000 is the latest addition to an already robust portfolio of OCT devices that are designed to meet the needs of all types and levels of practices and/or clinicians. It offers customers high-speed and high-throughput to help manage their large patient volume faster, all while improving imaging and image quality.
“This system was designed with the patient in mind, enabling doctors to continue accessing their patient data from CIRRUS devices that are crucial to effective long-term patient care,” said Jim Mazzo, Global President of Ophthalmic Devices at Carl Zeiss Meditec. “We are committed to our customers and believe this will become an essential asset to their practice.”The 100kHz speed of the CIRRUS 6000 allows clinicians to scan patients faster, with increased efficiency and improved imaging detail. Additional features include:
  • Wider and deeper OCT/OCTA scans with 12x12mm OCTA and B-scan depth up to 2.9mm
  • HD AngioPlex scan is a new scan type that provides more detail
  • New workflow protocols to aid in increasing efficiency
  • Patient-friendly “Wellness report” to help educate the patient
According to retina and vitreoretinal physician and surgeon Gregg T. Kokame, MD, of Retina Consultants of Hawaii, the new ZEISS CIRRUS 6000 is extremely fast and impressive. “With the new scan acquisition time of 100,000 per second I can scan and assess my patients much quicker, giving me the details I need with every image,” says Kokame.“ZEISS is dedicated to advancing eye care through development of new and innovative solutions, like the CIRRUS 6000,” said Dr. Ludwin Monz, President and CEO of Carl Zeiss Meditec AG. “With our comprehensive diagnostics portfolio, we will continue to create better vision standards to benefit patients today and in the future.”

Bison Dual ACCENTO Nd YAG Laser

Bison Dual ACCENTOBison Dual ACCENTO is the unique device combination with Alexandrite laser (755nm) and Nd:YAG laser (1064nm Long pulse) The combination of two different wavelengths makes DUAL ACCENTO a highly effective system for hair removal and pigmented lesions treatment. The 755nm penetrates deep into the skin and perfectly targets hair the follicle and absorbs melanin.The Dual Accento combined laser system is indicated for the following: 755 nm Long Pulsed Alexandrite Laser Temporary hair reduction. Stable long-term or permanent reduction through targeting of melanin in hair follicles. Treatment of bening pigmented lesions. Treatment of Wrinkles.The photocoagulation of dermatological vascular lesions (such as port of wine stains, hemangiomas, telangiectasis) 1064nm Long pulsed Nd:YAG laser. The removal of un-wanted hair reduction, for stable long term or permanent hair reduction and for treatment of PFB to all skin types Fitzpatrick I-VI including tanned skin.Pigmented lesions to reduce lesion size and patients with lesions. Reduction of red pigmentation in hypertrophic and keloid scars where vascularity is integral part of scar, treatment of wrinkle. Permanent hair reduction is defined as the long term, stable reduction in the number of hairs re- growing when measured at 6,9, and 12 months after the completion of treatment regime.The Dual Accento performs with high efficacy of the pigmentation problems without damaging tissue structures adjacent to the pigment. The wavelength of 1064nm Nd: YAG long pulse rejuvenates the skin by stimulating the collagen layer of the dermis and effectively treats vascular lesions and is appropriate for all skin types when used for hair removal.Bison Dual ACCENTO 1064nm NdYAG Laser With 755nm Alexandrite Laser Bison Dual ACCENTO 1064nm NdYAG Laser with 755nm Alexandrite Laser is the unique device. Combining 755nm Long pulsed Alexandrite and 1064nm Long pulsed NdYAG Alexandrite 755nm long pulsed wavelength. Due to the high melanin absorption is effective for hair removal and pigmented lesions treatment. NdYAG 1064nm long pulsed wavelength rejuvenates skin by stimulating the dermis layer, effectively treating vascular lesions.

Nidek OPD-Scan III Corneal Analyzer

Comprehensive vision analysis

OPD-Scan III VS is a device that mainly measures corneal shape (topographer) and refractive error (refractometer). It clarifies causes of vision difficulties through wavefront analysis of information measured over a wide area.


Solutions for face-to-face consulting

Tablet viewer provides four kinds of easy-to-understand reports for explanation and consulting. *The tablet is not included or sold with the OPD-Scan III VS.




Basic information report

Basic information to generally judge the patient’s eye conditions.




Topography report

Intuitive maps and numerical data for comprehending the corneal surface.



Simulation report

Visual performance simulations and MTF graphs for a variety of conditions.




Eye diagram image report

Eye model to visually understand eye conditions ranging from eye fundus to cornea.




Wide range of display patterns


Placido image


Axial map (Additional indication)


Visual Acuity map (Image charts)

Features Nidek OPD-Scan III Corneal Analyzer
  • Five-in-One true refractive workstation for all practitioners
  • Overview summary for optimal clinical decisions
  • A number of summaries
  • Wider measurement area
  • Greater topography resolution, blue placido rings
The OPD-Scan lll is the Five-in-One true refractive workstation combining
  • Wavefront Aberrometer
  • Topographer
  • Auto Refractometer
  • Auto Keratometer
  • Pupillometer and Pupillographer
  1. Irregularity helps determine the best strategy for vision correction. Separation into Total, Corneal and Internal components allows determination of the source of the optical pathology.
  2. PSF images of OPD, Axial, and Internal OPD map simulate objective retinal visual quality from each component of the eye for easy clinical assessment and patient education.
  3. Corneal Spherical Aberration aids in the selection of aspheric IOLs and contact lenses.
  4. Color coded Classification Indices help identify post-LASIK corneas and Keratoconus.
  5. The Astigmatism index aids the implantation of toric IOLs such as incision placement and lens alignment.
  6. A retroillumination image of cataracts captured during the OPD exam allows better understanding of pupillary effects on vision and in patient education.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD $6,950.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Shopping cart close