PERKASA MEDICAL

Free shipping worldwide. Orders over $200
Availability: In Stock

Tomey RT-7000 Autorefractor Keratometer Topographer For Sale

$11,350.00

The Tomey Refractometer Keratometer and Topographer only in 1 unit senior citizens and children can also get the inspection with out any trouble because they dont have to move the seat for three measurements.

Other people want this. 15 people have this in their carts right now.

Description

Tomey RT-7000 Autorefractor Keratometer Topographer

-Three Functions in One Instrument

-Easy & Speedy Touch Screen Alignment

-6.4 inches color TFT LCD

-Dual  CCD technology for Refractometry

-IOL/ Cataract Mode

-New incites for Keratometry KAI, KRI

-Auto Alignment / Auto Shot of Topography

Corneal Topography

– Auto Alignment / Auto Shot

Any one can easily capture measurement with Auto Alignment and Auto Shot. The Measurement variation is significantly reduced no matter what the skill level is of the operator.

CL Fitting Simulation

-A pseudo-fluorescent pattern of the contact lens selected from the built-in data base can be confirmed and the fitting can be stimulated before the patient wears  the trial lens.

Corneal Eccentricity Index

-The index of CEI (Corneal Eccentricity Index) indicates the ratio of flattering in percentage from the central cornea to the periphery.

Three Function in One Instrument

– Refractometer Keratometer and Topographer only in 1 unit senior citizens and children can also get the inspection with out any trouble because they don’t have to move the seat for three measurements. Switch from Ref-Kerato Mode to Corneal Topography Mode with only ONE TOUCH. The light come appears with only one button from the measuring head and the Ref-Keratometer is transformed to the topographer.

Refractometry

– Dual CCD technology for Refractometry

Two CCD cameras are used to capture images for observation and for measurement while providing highly accurate measurement data.

Keratometory

– New Indices for Keratometry

The Corneal Irregular astigmatism display function is installed to expand the possibility of Keratometer. This is the new function to measure the level of corneal irregular astigmatism which was difficult in the past.

SPECIFICATIONS

MeasurmentRanges

Refraction Measuremnt

Sphere  -25.00D to ±22.00DIVD=12.0mm

Cylinder  0D to ± 10.00DIVD=12.0mm

Axis  0 to 180

Corneal Curvature Measurement  5.00mm to 11.00mm

Measurement Zone 3mm R:8.00mm

Corneal Mapping

Display Range  9 to 100 D

-Normal Mode

1.0 to 8.0mm (R:8.00mm)

-Special Mode

0.9 to 7.0 mm (R:8.00mm)

Measurement Time

REF 0.2 Seconds

KRT 0.1 Seconds

Minimum Pupil Diameter  2.2mm

Minimum Measurment Step

 

Refraction Measurement

Sphere  0.01D

Cylinder  0.01D

Axis  1

Corneal Curvature Measurement  0.01mm

PD (Pupil Distance)  50mm to 86mm

Recording  Built-In Thermal Printer

Vertex Distance  0mm, 12.0mm, 13.5mm, 14.0mm, 15.5mm, 16.0mm

Exterior Output  (AN port / 4USB ports)

Dimensions Tomey RT-7000 Autorefractor Keratometer Topographer

High  466mmm or 18 Inches

Width  307mm or 12 Inches

Depth  490mm or 19 Inches

Weight  Approx 20,000Kg / 44.4 Pounds

Display  6.4 Inches color liquid crystal

Power Supply

Voltage  AC 100 to 240V

Frequency  50/60 Hz

Consumption Power  120VA to 150VA

Temperature  +10C to + 40C

Display  30% to 75%

Reviews

There are no reviews yet.

Be the first to review “Tomey RT-7000 Autorefractor Keratometer Topographer For Sale”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsTomey RT-7000 Autorefractor Keratometer Topographer For Sale removeActive Optical Systems Optima 518 IPL Laser removeTopcon KR-8800 Autorefractor Keratometer For Sale removeNidek OPD-Scan III Corneal Analyzer For Sale removeZeiss Humphrey Acuitus 5015 Autorefractor Keratometer removeTopcon KR8000PA Autorefractor Keratometer For Sale remove
NameTomey RT-7000 Autorefractor Keratometer Topographer For Sale removeActive Optical Systems Optima 518 IPL Laser removeTopcon KR-8800 Autorefractor Keratometer For Sale removeNidek OPD-Scan III Corneal Analyzer For Sale removeZeiss Humphrey Acuitus 5015 Autorefractor Keratometer removeTopcon KR8000PA Autorefractor Keratometer For Sale remove
Image
SKU
Rating
Price $11,350.00 $5,200.00 $3,200.00 $5,650.00 $1,800.00 $4,100.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

DescriptionThe Tomey Refractometer Keratometer and Topographer only in 1 unit senior citizens and children can also get the inspection with out any trouble because they dont have to move the seat for three measurements.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece: * Faster treatments – up to 0.5 Seconds Between pulses. * Real-time handpiece temperature control. * Contemporary and stylish design. * Light weight design – 25% less weight to improve the therapists’ comfort.

Topcon KR 8800 autorefractor keratometer has been checked and certified by an authorized Topcon technician.

The OPD-Scan III is an automated 5 in 1 instrument that combines topography, wavefront, autorefraction, keratometry, and pupillometry — allowing accurate and reliable analysis of corneal aberration.The Zeiss Humphrey Acuitus 5015 Auto Refractor Keratometer offers expanded refracting capabilities, allowing a practice to refract children and elderly patients alike. The Zeiss Acuitus 5015 also allows refraction one-day post operative of IOL and refractive surgery patients. The Zeiss Acuitus 5015 includes a flat color screen display which produces clear and concise images.The new tri-functional Autorefractor Keratometer Topcon KR-8000PA Supra combines an autorefractor, an autokeratometer, and a computerized color corneal mapping system all in a single, compact unit! This enables the instrument to provide three times the diagnostic capabilities in one-third the space, at a fraction of the cost of the individual instruments.
Content

Tomey RT-7000 Autorefractor Keratometer Topographer

-Three Functions in One Instrument-Easy & Speedy Touch Screen Alignment-6.4 inches color TFT LCD-Dual  CCD technology for Refractometry-IOL/ Cataract Mode-New incites for Keratometry KAI, KRI-Auto Alignment / Auto Shot of TopographyCorneal Topography– Auto Alignment / Auto ShotAny one can easily capture measurement with Auto Alignment and Auto Shot. The Measurement variation is significantly reduced no matter what the skill level is of the operator.CL Fitting Simulation-A pseudo-fluorescent pattern of the contact lens selected from the built-in data base can be confirmed and the fitting can be stimulated before the patient wears  the trial lens.Corneal Eccentricity Index-The index of CEI (Corneal Eccentricity Index) indicates the ratio of flattering in percentage from the central cornea to the periphery.Three Function in One Instrument– Refractometer Keratometer and Topographer only in 1 unit senior citizens and children can also get the inspection with out any trouble because they don’t have to move the seat for three measurements. Switch from Ref-Kerato Mode to Corneal Topography Mode with only ONE TOUCH. The light come appears with only one button from the measuring head and the Ref-Keratometer is transformed to the topographer.Refractometry– Dual CCD technology for RefractometryTwo CCD cameras are used to capture images for observation and for measurement while providing highly accurate measurement data.Keratometory– New Indices for KeratometryThe Corneal Irregular astigmatism display function is installed to expand the possibility of Keratometer. This is the new function to measure the level of corneal irregular astigmatism which was difficult in the past.SPECIFICATIONSMeasurmentRangesRefraction MeasuremntSphere  -25.00D to ±22.00DIVD=12.0mmCylinder  0D to ± 10.00DIVD=12.0mmAxis  0 to 180Corneal Curvature Measurement  5.00mm to 11.00mmMeasurement Zone 3mm R:8.00mmCorneal MappingDisplay Range  9 to 100 D-Normal Mode1.0 to 8.0mm (R:8.00mm)-Special Mode0.9 to 7.0 mm (R:8.00mm)Measurement TimeREF 0.2 SecondsKRT 0.1 SecondsMinimum Pupil Diameter  2.2mmMinimum Measurment Step Refraction MeasurementSphere  0.01DCylinder  0.01DAxis  1Corneal Curvature Measurement  0.01mmPD (Pupil Distance)  50mm to 86mmRecording  Built-In Thermal PrinterVertex Distance  0mm, 12.0mm, 13.5mm, 14.0mm, 15.5mm, 16.0mmExterior Output  (AN port / 4USB ports)Dimensions Tomey RT-7000 Autorefractor Keratometer TopographerHigh  466mmm or 18 InchesWidth  307mm or 12 InchesDepth  490mm or 19 InchesWeight  Approx 20,000Kg / 44.4 PoundsDisplay  6.4 Inches color liquid crystalPower SupplyVoltage  AC 100 to 240VFrequency  50/60 HzConsumption Power  120VA to 150VATemperature  +10C to + 40CDisplay  30% to 75%
Active Optical Systems Optima 518 IPL Laser
Handpiece (Standard):Multipurpose Wavelength Mark-II Handpiece (Optional):Facial Treatments Pulse Interval/Repetition Rate:0.5 – 2 Seconds Maximum Output Treatment Pattern:22 Joule /cm 2 Output Power:11-31 Joule / cm 2 , up to 4000 W Cooling System:Improved Air Cooling Control:Advanced Software Interface Lamp’s Life Span:200,000 Flashes (minimum) Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2) Wavelength:420 – 1,100 nm Weight:88.18 lbs (40Kg) (including stand) Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm) Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz Max Mains Power:600 VA Treatments Variety: Skin Rejuvenation Pigmentation Treatment Acne Treatment Hair Removal Hair Removal – Deep Follicles Hair Removal – Sensitive Skin Vascular (Facial) Treatment Tattoo Removal The Laser uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated. 12 Programs 1 – Very Dark Skin, Fitzpatrick Skin Type IV 2 – Dark Skin, Fitzpatrick Skin Type IV 3 – Dark Skin, Fitzpatrick Skin Type III 4 – Dark Skin, Fitzpatrick Skin Type III 5 – Medium Skin, Fitzpatrick Skin Type II 6 – Medium Skin, Fitzpatrick Skin Type II 7 – Light Skin, Fitzpatrick Skin Type II 8 – Light Skin, Fitzpatrick Skin Type I 9 – Very Light Skin, Fitzpatrick Skin Type I 10 – Very Light Skin, Fitzpatrick Skin Type I 11 – Very Light Skin, Fitzpatrick Skin Type I 12 – High Power, Fitzpatrick Skin Type IOptima-518-Classic Active Optical Systems Optima 518 IPL LaserThe Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece: * Faster treatments – up to 0.5 Seconds Between pulses. * Real-time handpiece temperature control. * Contemporary and stylish design. * Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.Approvals * CE MDD Intl. Medical Standard * FDA U.S. Safety Standard * ISO-13485 Med. Production STD * IEC 60-601-1 Medical Safety STD * CFS Gov. Health Approval * CSA Can. & U.S. Safety App * TGA Australian health STD.

Topcon KR-8800 Autorefractor Keratometer

The Topcon KR-8800 Autorefractor Keratometer features fast, easy and accurate measurements. The Topcon KR-8800 Autorefractor Keratometer also offers a 20% wider measurement range, a color LCD screen, and a 2.0mm minimum pupil diameter. Fast and accurate refraction and keratometry readings are also standard on the KR-8800, as well as a new color LCD screen. The Topcon KR-8800 Autorefractor Keratometer offers Rotary Prism measurement for enhanced accuracy. Other features offered on the Topcon KR-8800 Autorefractor Keratometer are simultaneous display of binocular readings, scenic fixation chart, USB connection for fast data transfer, and auto fire mode for fast reliable data collection.Simultaneous Display of Binocular Readings The new color LCD monitor simultaneously displays the readings of both right and left eyes so that the operator can instantly observe all of the pertinent information.Wider Measurement Range The new 8800 series’ wider range allows measurements to be obtained on patients with up to 10D of astigmatism.Rotary Prism Measurement System The new 8800 series features Topcon’s exclusive Rotary Prism Technology for unmatched accuracy and reliability. The off-centered ring target is able to measure areas that may be occluded by a small diameter pupil. The prism angle enables a much wider area of the retina to be measured. As a result, the measurement image provides extremely reliable data.Faster Measurement Topcon KR-8800 Autorefractor Keratometer The 8800 series are among the fastest auto refractors in the world. A specially designed CPU enables the 8800 series to significantly reduce the measurement time.Scenic Fixation Chart The scenic color chart makes eye fixation easier and is adjustable in two brightness levels for optimal measuring results with either large or small pupils.Auto Measurement As soon as the KR-8800 is properly aligned, this innovative function initiates the measurement process and completes three readings of each eye providing that proper alignment is maintained.Cornea Diameter Measurement Corneal diameter can be measured either during testing of the patient or later by recalling the image of the cornea on the monitor.

Nidek OPD-Scan III Corneal Analyzer

Comprehensive vision analysis

OPD-Scan III VS is a device that mainly measures corneal shape (topographer) and refractive error (refractometer). It clarifies causes of vision difficulties through wavefront analysis of information measured over a wide area.


Solutions for face-to-face consulting

Tablet viewer provides four kinds of easy-to-understand reports for explanation and consulting. *The tablet is not included or sold with the OPD-Scan III VS.




Basic information report

Basic information to generally judge the patient’s eye conditions.




Topography report

Intuitive maps and numerical data for comprehending the corneal surface.



Simulation report

Visual performance simulations and MTF graphs for a variety of conditions.




Eye diagram image report

Eye model to visually understand eye conditions ranging from eye fundus to cornea.




Wide range of display patterns


Placido image


Axial map (Additional indication)


Visual Acuity map (Image charts)

Features Nidek OPD-Scan III Corneal Analyzer
  • Five-in-One true refractive workstation for all practitioners
  • Overview summary for optimal clinical decisions
  • A number of summaries
  • Wider measurement area
  • Greater topography resolution, blue placido rings
The OPD-Scan lll is the Five-in-One true refractive workstation combining
  • Wavefront Aberrometer
  • Topographer
  • Auto Refractometer
  • Auto Keratometer
  • Pupillometer and Pupillographer
  1. Irregularity helps determine the best strategy for vision correction. Separation into Total, Corneal and Internal components allows determination of the source of the optical pathology.
  2. PSF images of OPD, Axial, and Internal OPD map simulate objective retinal visual quality from each component of the eye for easy clinical assessment and patient education.
  3. Corneal Spherical Aberration aids in the selection of aspheric IOLs and contact lenses.
  4. Color coded Classification Indices help identify post-LASIK corneas and Keratoconus.
  5. The Astigmatism index aids the implantation of toric IOLs such as incision placement and lens alignment.
  6. A retroillumination image of cataracts captured during the OPD exam allows better understanding of pupillary effects on vision and in patient education.

Zeiss Humphrey Acuitus 5015 Autorefractor Keratometer

Autorefractor/Keratometer that can take a combination of refraction, central and peripheral keratometry. Unit has been tested with a reference eye (not included) and as well with a test subject and takes accurate OD/OS reading. Great unit for your optometry practice. Unit is patient ready. This has just been professionally calibrated by our optical engineer. Also includes a printed out Acuitus 5015 User manual,power cord.
The Zeiss Humphrey Acuitus 5015 Auto Refractor Keratometer offers expanded refracting capabilities, allowing a practice to refract children and elderly patients alike. The Zeiss Acuitus 5015 also allows refraction one-day post operative of IOL and refractive surgery patients. The Zeiss Acuitus 5015 includes a flat color screen display which produces clear and concise images. Additional features on the Zeiss Acuitus 5015 include auto acquisition, auto XYZ, making the measurements easily acquired. Additional benefits on the Zeiss Acuitus 5015 are automatic eye detection, thirty measurements per second, and RS 232 interface. The Zeiss Acuitus 5015 offers a multitude of features in a small compact footprint at an extremely affordable price point.
Zeiss Humphrey Acuitus 5015 Autorefractor Keratometer Autorefractor/Keratometer that can take a combination of refraction, central and peripheral keratometry. Unit has been tested with a reference eye (not included) and as well with a test subject and takes accurate OD/OS reading. Great unit for your optometry practice. Unit is patient ready. This has just been professionally calibrated by our optical engineer. Also includes a printed out Acuitus 5015 User manual,power cord.Zeiss Humphrey Acuitus 5015 Autorefractor Keratometer allows refracting one-day postoperative IOL and refractive surgery patients with its expanded refracting capabilitiesZeiss Humphrey Acuitus 5015 is easily acquired because come with Auto Acquisition and Auto XYZ with benefits automatic eye detection, thirty measurements per second, RS 232 interface and affordability.central and peripheral keratometry measurements is another features come with Zeiss Humphrey Acuitus 5015Include: -Zeiss Humphrey Acuitus 5015 -Boxed calibrated Test Eye -Printer -a printed out Acuitus 5015 User Manual

Topcon KR8000PA Autorefractor Keratometer

By implementing Topcon’s Autorefractor Keratometer Topcon KR-8000PA Supraexclusive rotary prism technology for the refraction portion of the measurement, the Autorefractor Keratometer Topcon KR-8000PA Supra provides objective data that is unmatched in accuracy and reliability. Auto tracking and auto measurement enhance the ease of operation.

The Autorefractor Keratometer Topcon KR-8000PA Supra unit also incorporates ten placido rings for enhanced testing precision, providing corneal mapping measurements out to 10mm!

Features for Autorefractor Keratometer Topcon KR-8000PA Supra

Topcon Color Mapping 32 Software

This versatile 32-bit color mapping software system enhances clinical evaluations with the output of highly accurate, full color corneal maps. The system offers an enlarged color map, tangential axial maps, sagittal maps, refractive and keratometric data, and peripheral keratometric maps. It provides early phase detection of subclinical keratoconus as well as pre and post-op evaluation. The software also features a new image overlay function, as well as a Multi-Map and Difference Map View, which display multiple image maps for easy comparison.

The color mapping system is an excellent patient education tool and is designed for use with the Topcon KR-7000P or KR-8000PA Auto Refractor/Keratometer. Windows® 95/98/NT Compatible.

The color mapping software also features a contact lens fitting module with adjustable parameters to view the contact lens fit on screen.The Autorefractor Keratometer Topcon KR-8000PA Supra System Benefits Include:Topcon KR8000PA Autorefractor Keratometer
  • Allows Three Functions at One Station: – Refraction – Keratometry – Corneal Mapping
  • Contact Lens Fitting Utility
  • Early Phase Detection of Subclinical Keratoconus
  • Direct Link to CV System
The new tri-functional Autorefractor Keratometer Topcon KR-8000PA Supra combines an autorefractor, an autokeratometer, and a computerized color corneal mapping system all in a single, compact unit! This enables the instrument to provide three times the diagnostic capabilities in one-third the space, at a fraction of the cost of the individual instruments.

WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: Tomey RT-7000 Autorefractor Keratometer Topographer For Sale $11,350.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Shopping cart close