PERKASA MEDICAL

Free shipping worldwide. Orders over $200
Availability: In Stock

Tomey RT-7000 Autorefractor Keratometer Topographer For Sale

$11,350.00

The Tomey Refractometer Keratometer and Topographer only in 1 unit senior citizens and children can also get the inspection with out any trouble because they dont have to move the seat for three measurements.

Other people want this. 15 people have this in their carts right now.

Description

Tomey RT-7000 Autorefractor Keratometer Topographer

-Three Functions in One Instrument

-Easy & Speedy Touch Screen Alignment

-6.4 inches color TFT LCD

-Dual  CCD technology for Refractometry

-IOL/ Cataract Mode

-New incites for Keratometry KAI, KRI

-Auto Alignment / Auto Shot of Topography

Corneal Topography

– Auto Alignment / Auto Shot

Any one can easily capture measurement with Auto Alignment and Auto Shot. The Measurement variation is significantly reduced no matter what the skill level is of the operator.

CL Fitting Simulation

-A pseudo-fluorescent pattern of the contact lens selected from the built-in data base can be confirmed and the fitting can be stimulated before the patient wears  the trial lens.

Corneal Eccentricity Index

-The index of CEI (Corneal Eccentricity Index) indicates the ratio of flattering in percentage from the central cornea to the periphery.

Three Function in One Instrument

– Refractometer Keratometer and Topographer only in 1 unit senior citizens and children can also get the inspection with out any trouble because they don’t have to move the seat for three measurements. Switch from Ref-Kerato Mode to Corneal Topography Mode with only ONE TOUCH. The light come appears with only one button from the measuring head and the Ref-Keratometer is transformed to the topographer.

Refractometry

– Dual CCD technology for Refractometry

Two CCD cameras are used to capture images for observation and for measurement while providing highly accurate measurement data.

Keratometory

– New Indices for Keratometry

The Corneal Irregular astigmatism display function is installed to expand the possibility of Keratometer. This is the new function to measure the level of corneal irregular astigmatism which was difficult in the past.

SPECIFICATIONS

MeasurmentRanges

Refraction Measuremnt

Sphere  -25.00D to ±22.00DIVD=12.0mm

Cylinder  0D to ± 10.00DIVD=12.0mm

Axis  0 to 180

Corneal Curvature Measurement  5.00mm to 11.00mm

Measurement Zone 3mm R:8.00mm

Corneal Mapping

Display Range  9 to 100 D

-Normal Mode

1.0 to 8.0mm (R:8.00mm)

-Special Mode

0.9 to 7.0 mm (R:8.00mm)

Measurement Time

REF 0.2 Seconds

KRT 0.1 Seconds

Minimum Pupil Diameter  2.2mm

Minimum Measurment Step

 

Refraction Measurement

Sphere  0.01D

Cylinder  0.01D

Axis  1

Corneal Curvature Measurement  0.01mm

PD (Pupil Distance)  50mm to 86mm

Recording  Built-In Thermal Printer

Vertex Distance  0mm, 12.0mm, 13.5mm, 14.0mm, 15.5mm, 16.0mm

Exterior Output  (AN port / 4USB ports)

Dimensions Tomey RT-7000 Autorefractor Keratometer Topographer

High  466mmm or 18 Inches

Width  307mm or 12 Inches

Depth  490mm or 19 Inches

Weight  Approx 20,000Kg / 44.4 Pounds

Display  6.4 Inches color liquid crystal

Power Supply

Voltage  AC 100 to 240V

Frequency  50/60 Hz

Consumption Power  120VA to 150VA

Temperature  +10C to + 40C

Display  30% to 75%

Reviews

There are no reviews yet.

Be the first to review “Tomey RT-7000 Autorefractor Keratometer Topographer For Sale”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsTomey RT-7000 Autorefractor Keratometer Topographer For Sale removeCarl Zeiss Cirrus HD-OCT 4000 removeNidek OPD-Scan III Corneal Analyzer For Sale removeEssilor Mr Blue 2.0 Lens Edgers and Tracer For Sale removeTomey RC-800 Auto Refractor Keratometer For Sale removeActive Optical Systems Optima 518 IPL Laser remove
NameTomey RT-7000 Autorefractor Keratometer Topographer For Sale removeCarl Zeiss Cirrus HD-OCT 4000 removeNidek OPD-Scan III Corneal Analyzer For Sale removeEssilor Mr Blue 2.0 Lens Edgers and Tracer For Sale removeTomey RC-800 Auto Refractor Keratometer For Sale removeActive Optical Systems Optima 518 IPL Laser remove
Image
SKU
Rating
Price $11,350.00 $3,980.00 $5,650.00 $3,600.00 $3,700.00 $5,200.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

DescriptionThe Tomey Refractometer Keratometer and Topographer only in 1 unit senior citizens and children can also get the inspection with out any trouble because they dont have to move the seat for three measurements.
CIRRUS 4000 delivers high-speed image capture with HD imaging detail and a wider field of view so you can make more informed decisions and spend more time with the patients who need it.
The OPD-Scan III is an automated 5 in 1 instrument that combines topography, wavefront, autorefraction, keratometry, and pupillometry — allowing accurate and reliable analysis of corneal aberration.Mr Blue 2.0 is on the cutting edge of innovation – serving as a genuine ECP partner since its launch. Now featuring a whole range of new functions and even greater flexibility, Mr Blue is the perfect solution for demanding workshop.The Auto “Refkeratometer” RC-800 is the latest in economical, user-friendly, highly accurate auto “refkeratometry”. The RC-800 provides simple, easy measurement by the operator at an economical cost, without compromising accuracy or reliability.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece: * Faster treatments – up to 0.5 Seconds Between pulses. * Real-time handpiece temperature control. * Contemporary and stylish design. * Light weight design – 25% less weight to improve the therapists’ comfort.
Content

Tomey RT-7000 Autorefractor Keratometer Topographer

-Three Functions in One Instrument-Easy & Speedy Touch Screen Alignment-6.4 inches color TFT LCD-Dual  CCD technology for Refractometry-IOL/ Cataract Mode-New incites for Keratometry KAI, KRI-Auto Alignment / Auto Shot of TopographyCorneal Topography– Auto Alignment / Auto ShotAny one can easily capture measurement with Auto Alignment and Auto Shot. The Measurement variation is significantly reduced no matter what the skill level is of the operator.CL Fitting Simulation-A pseudo-fluorescent pattern of the contact lens selected from the built-in data base can be confirmed and the fitting can be stimulated before the patient wears  the trial lens.Corneal Eccentricity Index-The index of CEI (Corneal Eccentricity Index) indicates the ratio of flattering in percentage from the central cornea to the periphery.Three Function in One Instrument– Refractometer Keratometer and Topographer only in 1 unit senior citizens and children can also get the inspection with out any trouble because they don’t have to move the seat for three measurements. Switch from Ref-Kerato Mode to Corneal Topography Mode with only ONE TOUCH. The light come appears with only one button from the measuring head and the Ref-Keratometer is transformed to the topographer.Refractometry– Dual CCD technology for RefractometryTwo CCD cameras are used to capture images for observation and for measurement while providing highly accurate measurement data.Keratometory– New Indices for KeratometryThe Corneal Irregular astigmatism display function is installed to expand the possibility of Keratometer. This is the new function to measure the level of corneal irregular astigmatism which was difficult in the past.SPECIFICATIONSMeasurmentRangesRefraction MeasuremntSphere  -25.00D to ±22.00DIVD=12.0mmCylinder  0D to ± 10.00DIVD=12.0mmAxis  0 to 180Corneal Curvature Measurement  5.00mm to 11.00mmMeasurement Zone 3mm R:8.00mmCorneal MappingDisplay Range  9 to 100 D-Normal Mode1.0 to 8.0mm (R:8.00mm)-Special Mode0.9 to 7.0 mm (R:8.00mm)Measurement TimeREF 0.2 SecondsKRT 0.1 SecondsMinimum Pupil Diameter  2.2mmMinimum Measurment Step Refraction MeasurementSphere  0.01DCylinder  0.01DAxis  1Corneal Curvature Measurement  0.01mmPD (Pupil Distance)  50mm to 86mmRecording  Built-In Thermal PrinterVertex Distance  0mm, 12.0mm, 13.5mm, 14.0mm, 15.5mm, 16.0mmExterior Output  (AN port / 4USB ports)Dimensions Tomey RT-7000 Autorefractor Keratometer TopographerHigh  466mmm or 18 InchesWidth  307mm or 12 InchesDepth  490mm or 19 InchesWeight  Approx 20,000Kg / 44.4 PoundsDisplay  6.4 Inches color liquid crystalPower SupplyVoltage  AC 100 to 240VFrequency  50/60 HzConsumption Power  120VA to 150VATemperature  +10C to + 40CDisplay  30% to 75%

Carl Zeiss Cirrus HD-OCT 4000

The Cirrus HD-OCT is a non-contact, high resolution tomographic and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures, including cornea, retina, retinal nerve fiber layer, ganglion cell plus inner plexiform layer, macula, and optic nerve head. The Cirrus normative databases are quantitative tools for the comparison of retinal nerve fiber layer thickness, macular thickness, ganglion cell plus inner plexiform layer thickness, and optic nerve head measurements to a database of normal subjects. The Cirrus HD-OCT is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration, and glaucoma.The ZEISS Certified Factory Direct Cirrus 4000 HD-OCT also includes the full Accessory Kit External Fixation Light Test Eye Mini Keyboard Optical Mouse Dust Cover Metric 5A/250v Fuse 14 Ft. CAT 5e Network Cable USB Cable IEC 320 to NEMA 12 inch Power Cable IEC 320 39in. Power Cable Install Disc including Roxio Basic Symbol Sheet OCT Primer Guide Quick Start GuideHD-OCT ImagingMethodology: Spectral Domain OCT Optical Source: superluminescent diode (SLD), 840 nm Optical Power: < 725 μW at the cornea Scan Speed: 27,000 A-scans per second A-Scan depth: 2.0 mm (in tissue), 1024 points Axial resolution: 5 μm (in tissue) Transverse resolution: 15 μm (in tissue)Zeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD Fundus ImagingMethodology: Line scanning ophthalmoscope Live Fundus Image: During alignment and during OCT scan Optical Source: Superluminescent diode (SLD), 750 nm Optical Power: < 1.5 mW at the cornea Field of View: 36 degrees W x 30 degrees H Frame rate: >20 Hz Transverse resolution: 25 μm (in tissue)Carl Zeiss Cirrus HD-OCT 4000 Iris ImagingMethodology: CCD Camera Resolution: 1280 x 1024 Live iris image: During alignmentElectrical, Physical and EnvironmentalWeight: 38kg (83 lbs) Dimensions: 65L x 44W x 53H (cm) Fixation: Internal, external Internal fixation focus adjustment: -20D to +20D (diopters) Input devices: Keyboard, mouse Electrical rating (115V) Single Phase, 100/120V~ systems:50-60Hz, 5A Fuse rating (115V) T 5A 250V Electrical rating (230V) Single Phase, 220/240V~ systems:50-60 Hz, 2.5A Fuse rating (230V) Fuse rating: T 5A 250V Convenience Receptacle output ratings 115V~, 0.5 A Max, 50-60 Hz Temperature (transport and storage) -40º to +70º C Relative humidity (transport and storage) 10% to 100%, including condensation Atmospheric pressure (transport and storage): 500 hPa to 1060 hPa Temperature (operation) +10º to +35º C Relative humidity (operation) 30% to 75%, excluding condensation Atmospheric Pressure (operation) 700 hPa to 1060 hPa

Nidek OPD-Scan III Corneal Analyzer

Comprehensive vision analysis

OPD-Scan III VS is a device that mainly measures corneal shape (topographer) and refractive error (refractometer). It clarifies causes of vision difficulties through wavefront analysis of information measured over a wide area.


Solutions for face-to-face consulting

Tablet viewer provides four kinds of easy-to-understand reports for explanation and consulting. *The tablet is not included or sold with the OPD-Scan III VS.




Basic information report

Basic information to generally judge the patient’s eye conditions.




Topography report

Intuitive maps and numerical data for comprehending the corneal surface.



Simulation report

Visual performance simulations and MTF graphs for a variety of conditions.




Eye diagram image report

Eye model to visually understand eye conditions ranging from eye fundus to cornea.




Wide range of display patterns


Placido image


Axial map (Additional indication)


Visual Acuity map (Image charts)

Features Nidek OPD-Scan III Corneal Analyzer
  • Five-in-One true refractive workstation for all practitioners
  • Overview summary for optimal clinical decisions
  • A number of summaries
  • Wider measurement area
  • Greater topography resolution, blue placido rings
The OPD-Scan lll is the Five-in-One true refractive workstation combining
  • Wavefront Aberrometer
  • Topographer
  • Auto Refractometer
  • Auto Keratometer
  • Pupillometer and Pupillographer
  1. Irregularity helps determine the best strategy for vision correction. Separation into Total, Corneal and Internal components allows determination of the source of the optical pathology.
  2. PSF images of OPD, Axial, and Internal OPD map simulate objective retinal visual quality from each component of the eye for easy clinical assessment and patient education.
  3. Corneal Spherical Aberration aids in the selection of aspheric IOLs and contact lenses.
  4. Color coded Classification Indices help identify post-LASIK corneas and Keratoconus.
  5. The Astigmatism index aids the implantation of toric IOLs such as incision placement and lens alignment.
  6. A retroillumination image of cataracts captured during the OPD exam allows better understanding of pupillary effects on vision and in patient education.
Essilor Mr Blue 2.0 Lens Edgers and TracerComplete Control of Lens Mounting
  • Optimal monitoring of all trajectories, irrespective of finishing materials or shapes
  • Absolute axis control thanks to hybrid edging technology: grinding + milling
  • Ideally suited for quality finishing even on highest base curves
  • Fast and accurate drilling with data acquired in a single operation
  • Automatic centering and blocking for simple operation
Unrivalled Ergonomics
  • Completely integrated functions without external peripheral devices
  • Vertical architecture with <Heads-up displays> for optimum comfort
  • Storage features ensure all accessories are within reach.
  • Intelligent interface adapts to the way you work.
Highest Quality Guaranteed Essilor Mr Blue 2.0 Lens Edgers and TracerPerfect Centering
  • Binocular 3-D tracing of full-rim frames up to base 9*
  • Automatic adjustment of centering data based on the frames’ 30D parameters*
Aesthetic and Robust Mountings
  • FIT-4-Frame technology with dedicated small wheel*
  • Drilling and grooving tools can be tilted up to 30o, making it safe to mount lenses of up to base 10. *Essilor patents and exclusives
Safe Process
  • Roughing cycle automatically adapts to the curves of lenses up to base 10, avoiding all risk of breakage
  • Bevel placement and shelf depth optimized for safe mounting without undue stress of lens
Aesthetically Pleasing and Easy-to-Mount Bevels
  • The bevel heights are adjustable to perfectly adjust to the thinnest grooves
  • The shelf bevel heights are optimized to follow the frame’s shape perfectly
  • The step bevel is particularly suited for sport eyeglasses with deep, rectangular or uneven groove profile
Mr Blue 2.0 is on the cutting edge of innovation – serving as a genuine ECP partner since its launch. Now featuring a whole range of new functions and even greater flexibility, Mr Blue is the perfect solution for demanding workshop.

Tomey RC-800 Auto Refractor Keratometer

Refractometry: Simple handling of the fine adjustment and measurement by yourself. Fogging is applied automatically for each measurement for more accurate results.Keratometry: Short consecutive measurements and time provide reliable data. Measurements at φ3.0mm (R = 8.0mm) give you enough information for contact lens fitting.Diameter Measurement of Cornea and Pupil: Easy measurement by moving the two cursors on the display to the boundaries of Cornea or Pupil.Language Selection: RC-800 has a Multi-language function. You can select your required language from “English”, “Japanese”, “German”, “Chinese”, “Spanish”, “Spanish Latin America”, “Italian”, “Portuguese”, “French” and “Russian”.Features:• Highly Accurate • Simple to Use • Diameter Measurement of Cornea and Pupil • High Speed Printer • Auto Shot • Color Touch Screen • USB connection • Large Patient Database • Easy Database Operation • Multi-Language Operation • Fourier Refractive Analysis • Quick Data Reference • Built-in LCD Alignment • Keratoconus Screening & Other ApplicationsMeasurement Ranges:Refraction:• Sphere: -25.00D to +22.00D (VD=12.0mm) • Cylinder: 0D to ±10.00D (VD=12.0mm) • Axis: 0° to 180° • Minimum Pupil Dia: Ø2.0mm • Measurement time: 0.2 second/single eye (data taking time)Keratometry:• Range: 5.00mm to 11.00mm • Corneal Refraction: 30.68D to 67.50D (n=1.3375) • Corneal Astigmatism: 0D to 10D (n=1.3375) • Axis: 0° to 180° • Measurement area: Ø3mm (at 8.00mm corneal curvature) • Measurement time: 0.1 second/single eye (data taking time)Other features:Tomey RC-800 Auto Refractor Keratometer• PD Measurement range 50 to 86mm • Corneal diameter measurement • Measurement range: 10.0 to 14.0mm • Display unit: 0.1mm • Pupil diameter measurement • Measurement range: 1.0 to 10.0 mm • Display unit: 0.1mm • Built-in Printer Thermal printer • Data output type RS232C / USB-D • Display 5.7 inch color liquid crystal display • Dimensions and weight 297(W)x 500(D) x 448(H)mm • Approx. 17kg • Power Requirements AC 100V to 240V, 50 / 60 Hz, 80VA to 100VAThe Auto “Refkeratometer” RC-800 is the latest in economical, user-friendly, highly accurate auto “refkeratometry”. The RC-800 provides simple, easy measurement by the operator at an economical cost, without compromising accuracy or reliability.

Active Optical Systems Optima 518 IPL Laser
Handpiece (Standard):Multipurpose Wavelength Mark-II Handpiece (Optional):Facial Treatments Pulse Interval/Repetition Rate:0.5 – 2 Seconds Maximum Output Treatment Pattern:22 Joule /cm 2 Output Power:11-31 Joule / cm 2 , up to 4000 W Cooling System:Improved Air Cooling Control:Advanced Software Interface Lamp’s Life Span:200,000 Flashes (minimum) Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2) Wavelength:420 – 1,100 nm Weight:88.18 lbs (40Kg) (including stand) Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm) Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz Max Mains Power:600 VA Treatments Variety: Skin Rejuvenation Pigmentation Treatment Acne Treatment Hair Removal Hair Removal – Deep Follicles Hair Removal – Sensitive Skin Vascular (Facial) Treatment Tattoo Removal The Laser uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated. 12 Programs 1 – Very Dark Skin, Fitzpatrick Skin Type IV 2 – Dark Skin, Fitzpatrick Skin Type IV 3 – Dark Skin, Fitzpatrick Skin Type III 4 – Dark Skin, Fitzpatrick Skin Type III 5 – Medium Skin, Fitzpatrick Skin Type II 6 – Medium Skin, Fitzpatrick Skin Type II 7 – Light Skin, Fitzpatrick Skin Type II 8 – Light Skin, Fitzpatrick Skin Type I 9 – Very Light Skin, Fitzpatrick Skin Type I 10 – Very Light Skin, Fitzpatrick Skin Type I 11 – Very Light Skin, Fitzpatrick Skin Type I 12 – High Power, Fitzpatrick Skin Type IOptima-518-Classic Active Optical Systems Optima 518 IPL LaserThe Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece: * Faster treatments – up to 0.5 Seconds Between pulses. * Real-time handpiece temperature control. * Contemporary and stylish design. * Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.Approvals * CE MDD Intl. Medical Standard * FDA U.S. Safety Standard * ISO-13485 Med. Production STD * IEC 60-601-1 Medical Safety STD * CFS Gov. Health Approval * CSA Can. & U.S. Safety App * TGA Australian health STD.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: Tomey RT-7000 Autorefractor Keratometer Topographer For Sale $11,350.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Shopping cart close