PERKASA MEDICAL

Free shipping worldwide. Orders over $200
Availability: In Stock

Tomey RC-5000 Auto Refractor Keratometer For Sale

$4,800.00

The Tomey RC-5000 has highly accurate measurement combined with short examination time and ease of use, makes working with the Tomey RC-5000 Autorefractor Keratometer both professional and quick. The advanced touch-screen display allows you to perform both refraction and keratometry automatically with one simple movement, capture one eye on the display and the Tomey RC-5000 will do both eyes automatically. With the new features, the Tomey RC-5000 Autorefractor Keratometer will surely make your office more efficient.

Other people want this. 15 people have this in their carts right now.

Description

Tomey RC-5000 Auto Refractor Keratometer

Tomey RC-5000 Refractometry

Normal Mode:

-Fogging is applied automatically for each measurement for more Accurate Results

Quick Mode:

-Fogging is applied as needed for consecutive measurements.

IOL/CAT Mode:

-This mode is used to measure cataract or pseudophakic eyes.

Keratometry:

-Short consecutive measurements and time provide reliable data.
-Measurements at 6.00mm (R=8.0mm) as well as at 3.00mm give you enough information for contact lens fitting.
-base curves of contact lenses are stored, categorized and suggested manufacturers are automatically printed.

Diameter Measurements of Cornea and Pupil:

-Measurement can be done easily by moving the two cursors on the display to the boundary of cornea or pupil. This is useful for deciding the diameter of a contact lens and for other contact lens fitting practice.

Power Joystick:

-Move the joystick ring up/down and the instrument head moves up/down quickly.
-Move the joystick hand rest to the right/left or backward/forward and the instrument head moves to the right/left or backward/forward quickly.
-Rotate the joystick ring and the instrument head moves up/down slowly.
-Tilt the joystick and the instrument head moves in each direction slowly.

Power Chinrest:

-The chin rest can be moved by pushing the buttons on the front panel. No need to reach out to the chin rest for manual adjustments.

Autorefractor Keratometer Features:

Refractometory : Tomey RC-5000 Auto Refractor Keratometer

-Sphere 25.00 to +22.00D (VD =12.00mm) Cylinder -10.00 to +10.00D (VD = 12.00mm)
-Axis 0 to 180 Degree
-Minimum Pupil Dia. 2.2mm
-Measurements Time 0.2 Sec.

Keratometry :

-Range 5.00mm to 11.00mm
-Corneal Refraction 30.68D to 67.50D (n = 1.3375)
-Corneal Astigmatism 0D to 10D (n = 1.3375)
-Axis 0 to 180 Degree
-Measured Area 3.0mm / 6.0 mm
-Measured Time 0.1 Sec PD
-Measurement Yes (50 to 86mm)
-Diameter Measuremnt of Cornea & Pupil 1.0 to 14.0mm
-Chinrest : Power Chin Rest
-Printer : High Speed Thermal Line Printer
-OutputPort RS-232C
-Power Requirements: AC 100V to 240V
-50/60Hz 130VA

Reviews

There are no reviews yet.

Be the first to review “Tomey RC-5000 Auto Refractor Keratometer For Sale”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsTomey RC-5000 Auto Refractor Keratometer For Sale removeNidek CEM-530 Specular Microscope For Sale removeTomey RC-800 Auto Refractor Keratometer For Sale removeActive Optical Systems Optima 518 IPL Laser removeEssilor Mr Blue 2.0 Lens Edgers and Tracer For Sale removeZeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD remove
NameTomey RC-5000 Auto Refractor Keratometer For Sale removeNidek CEM-530 Specular Microscope For Sale removeTomey RC-800 Auto Refractor Keratometer For Sale removeActive Optical Systems Optima 518 IPL Laser removeEssilor Mr Blue 2.0 Lens Edgers and Tracer For Sale removeZeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD remove
Image
SKU
Rating
Price $4,800.00 $3,250.00 $3,700.00 $5,200.00 $3,600.00 $4,500.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

DescriptionThe Tomey RC-5000 has highly accurate measurement combined with short examination time and ease of use, makes working with the Tomey RC-5000 Autorefractor Keratometer both professional and quick. The advanced touch-screen display allows you to perform both refraction and keratometry automatically with one simple movement, capture one eye on the display and the Tomey RC-5000 will do both eyes automatically. With the new features, the Tomey RC-5000 Autorefractor Keratometer will surely make your office more efficient.

Combination of auto and manual analyses

All three manual analysis methods can be performed on the same image and also on auto-analyzed images. The versatility of combining automated and manual analyses allows analysis of the range of pathology in a comprehensive practice.
The CEM-530 with new advanced software and enhanced image capture system allows rapid image acquisition. 
The Auto “Refkeratometer” RC-800 is the latest in economical, user-friendly, highly accurate auto “refkeratometry”. The RC-800 provides simple, easy measurement by the operator at an economical cost, without compromising accuracy or reliability.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece: * Faster treatments – up to 0.5 Seconds Between pulses. * Real-time handpiece temperature control. * Contemporary and stylish design. * Light weight design – 25% less weight to improve the therapists’ comfort.Mr Blue 2.0 is on the cutting edge of innovation – serving as a genuine ECP partner since its launch. Now featuring a whole range of new functions and even greater flexibility, Mr Blue is the perfect solution for demanding workshop.The Cirrus HD-OCT is a non-contact, high resolution tomographic and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures, including cornea, retina, retinal nerve fiber layer, ganglion cell plus inner plexiform layer, macula, and optic nerve head. The Cirrus normative databases are quantitative tools for the comparison of retinal nerve fiber layer thickness, macular thickness, ganglion cell plus inner plexiform layer thickness, and optic nerve head measurements to a database of normal subjects. The Cirrus HD-OCT is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration, and glaucoma.
Content

Tomey RC-5000 Auto Refractor Keratometer

Tomey RC-5000 RefractometryNormal Mode:-Fogging is applied automatically for each measurement for more Accurate ResultsQuick Mode:-Fogging is applied as needed for consecutive measurements.IOL/CAT Mode:-This mode is used to measure cataract or pseudophakic eyes.Keratometry:-Short consecutive measurements and time provide reliable data. -Measurements at 6.00mm (R=8.0mm) as well as at 3.00mm give you enough information for contact lens fitting. -base curves of contact lenses are stored, categorized and suggested manufacturers are automatically printed.Diameter Measurements of Cornea and Pupil:-Measurement can be done easily by moving the two cursors on the display to the boundary of cornea or pupil. This is useful for deciding the diameter of a contact lens and for other contact lens fitting practice.Power Joystick:-Move the joystick ring up/down and the instrument head moves up/down quickly. -Move the joystick hand rest to the right/left or backward/forward and the instrument head moves to the right/left or backward/forward quickly. -Rotate the joystick ring and the instrument head moves up/down slowly. -Tilt the joystick and the instrument head moves in each direction slowly.Power Chinrest:-The chin rest can be moved by pushing the buttons on the front panel. No need to reach out to the chin rest for manual adjustments.Autorefractor Keratometer Features:Refractometory : Tomey RC-5000 Auto Refractor Keratometer-Sphere 25.00 to +22.00D (VD =12.00mm) Cylinder -10.00 to +10.00D (VD = 12.00mm) -Axis 0 to 180 Degree -Minimum Pupil Dia. 2.2mm -Measurements Time 0.2 Sec.Keratometry :-Range 5.00mm to 11.00mm -Corneal Refraction 30.68D to 67.50D (n = 1.3375) -Corneal Astigmatism 0D to 10D (n = 1.3375) -Axis 0 to 180 Degree -Measured Area 3.0mm / 6.0 mm -Measured Time 0.1 Sec PD -Measurement Yes (50 to 86mm) -Diameter Measuremnt of Cornea & Pupil 1.0 to 14.0mm -Chinrest : Power Chin Rest -Printer : High Speed Thermal Line Printer -OutputPort RS-232C -Power Requirements: AC 100V to 240V -50/60Hz 130VA

Nidek CEM-530 Specular Microscope

The analysis results with graphic and color-coded cell images helps the clinician to rapidly and effectively evaluate the endothelial cell layer.In addition to conventional central and peripheral specular microscopy, the CEM-530 includes a unique function to capture paracentral images.
  • Paracentral specular microscopy
  • Faster measurements and two-second auto analysis
  • Comprehensive analysis
  • Advanced manual analysis functions
  • Easy operation
  • Additional features with CEM Viewer for NAVIS-EX
Combination of auto and manual analyses
All three manual analysis methods can be performed on the same image and also on auto-analyzed images. The versatility of combining automated and manual analyses allows analysis of the range of pathology in a comprehensive practice.Features
  • Multi area specular microscopy
  • Enhanced usability and quick analysis
  • Advanced manual analysis functions
  • Combination of auto and manual analyses
  • Additional features with CEM Viewer for NAVIS-EX
Multi area specular microscopy
In addition to conventional central and peripheral specular microscopy, the CEM-530 includes a NIDEK original function that captures paracentral images. The combination of central, paracentral, and peripheral imaging provides a broader, overall view that can be used for detailed morphological and quantitative evaluation of the endothelial layer and individual cells.


Enhanced usability and quick analysis

The 3D auto tracking and auto shot functions result in a user friendly and patient friendly experience. Data analysis within 2 seconds allows efficient patient flow.

Detail analysis


Advanced manual analysis functions
Center point

Select the approximate center of a cell. The cells are detected based on the surrounding points. This method is effective for areas where groups of cells are clumped together.




Corner point

Trace the outlines of the cells to be analyzed by selecting the corners of each cell. This method is suitable for detailed identification of the size and dimension of isolated cells.




Pattern select

Select a hexagonal reference pattern that is similar to the cell size and drag it onto the cell to be analyzed. This method is effective for rough identification of the size and dimension of the cells.


 Combination of auto and manual analyses 
All three manual analysis methods can be performed on the same image and on auto-analyzed images. The versatility of combining automated and manual analysis on the same image allows for better clinical interpretation of the diverse range of pathology in a comprehensive practice.


Additional features with CEM Viewer for NAVIS-EX* (optional)
CEM Viewer is software used for viewing and working with CEM-530 data via NAVIS-EX. This function enhances the capability of the CEM-530 with additional features and increases the efficiency of any clinic. *NAVIS-EX is optional software and is required for use of the CEM Viewer.
Data management and endothelial cell count

Unlimited NAVIS-EX database is available for review on the CEM Viewer. The basic functions of the CEM-530 such as endothelial cell count are available on the CEM Viewer.




Progression follow-up and comparison

Multiple examination data sets are displayed in chronological order for follow-up. Additionally, two data sets are displayed for comparison. Endothelial changes can be monitored over time with this function.





Paracentral display with peripheral
The images and analyses of the paracentral and peripheral areas are displayed providing a comprehensive image of endothelial cells.

Tomey RC-800 Auto Refractor Keratometer

Refractometry: Simple handling of the fine adjustment and measurement by yourself. Fogging is applied automatically for each measurement for more accurate results.Keratometry: Short consecutive measurements and time provide reliable data. Measurements at φ3.0mm (R = 8.0mm) give you enough information for contact lens fitting.Diameter Measurement of Cornea and Pupil: Easy measurement by moving the two cursors on the display to the boundaries of Cornea or Pupil.Language Selection: RC-800 has a Multi-language function. You can select your required language from “English”, “Japanese”, “German”, “Chinese”, “Spanish”, “Spanish Latin America”, “Italian”, “Portuguese”, “French” and “Russian”.Features:• Highly Accurate • Simple to Use • Diameter Measurement of Cornea and Pupil • High Speed Printer • Auto Shot • Color Touch Screen • USB connection • Large Patient Database • Easy Database Operation • Multi-Language Operation • Fourier Refractive Analysis • Quick Data Reference • Built-in LCD Alignment • Keratoconus Screening & Other ApplicationsMeasurement Ranges:Refraction:• Sphere: -25.00D to +22.00D (VD=12.0mm) • Cylinder: 0D to ±10.00D (VD=12.0mm) • Axis: 0° to 180° • Minimum Pupil Dia: Ø2.0mm • Measurement time: 0.2 second/single eye (data taking time)Keratometry:• Range: 5.00mm to 11.00mm • Corneal Refraction: 30.68D to 67.50D (n=1.3375) • Corneal Astigmatism: 0D to 10D (n=1.3375) • Axis: 0° to 180° • Measurement area: Ø3mm (at 8.00mm corneal curvature) • Measurement time: 0.1 second/single eye (data taking time)Other features:Tomey RC-800 Auto Refractor Keratometer• PD Measurement range 50 to 86mm • Corneal diameter measurement • Measurement range: 10.0 to 14.0mm • Display unit: 0.1mm • Pupil diameter measurement • Measurement range: 1.0 to 10.0 mm • Display unit: 0.1mm • Built-in Printer Thermal printer • Data output type RS232C / USB-D • Display 5.7 inch color liquid crystal display • Dimensions and weight 297(W)x 500(D) x 448(H)mm • Approx. 17kg • Power Requirements AC 100V to 240V, 50 / 60 Hz, 80VA to 100VAThe Auto “Refkeratometer” RC-800 is the latest in economical, user-friendly, highly accurate auto “refkeratometry”. The RC-800 provides simple, easy measurement by the operator at an economical cost, without compromising accuracy or reliability.

Active Optical Systems Optima 518 IPL Laser
Handpiece (Standard):Multipurpose Wavelength Mark-II Handpiece (Optional):Facial Treatments Pulse Interval/Repetition Rate:0.5 – 2 Seconds Maximum Output Treatment Pattern:22 Joule /cm 2 Output Power:11-31 Joule / cm 2 , up to 4000 W Cooling System:Improved Air Cooling Control:Advanced Software Interface Lamp’s Life Span:200,000 Flashes (minimum) Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2) Wavelength:420 – 1,100 nm Weight:88.18 lbs (40Kg) (including stand) Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm) Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz Max Mains Power:600 VA Treatments Variety: Skin Rejuvenation Pigmentation Treatment Acne Treatment Hair Removal Hair Removal – Deep Follicles Hair Removal – Sensitive Skin Vascular (Facial) Treatment Tattoo Removal The Laser uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated. 12 Programs 1 – Very Dark Skin, Fitzpatrick Skin Type IV 2 – Dark Skin, Fitzpatrick Skin Type IV 3 – Dark Skin, Fitzpatrick Skin Type III 4 – Dark Skin, Fitzpatrick Skin Type III 5 – Medium Skin, Fitzpatrick Skin Type II 6 – Medium Skin, Fitzpatrick Skin Type II 7 – Light Skin, Fitzpatrick Skin Type II 8 – Light Skin, Fitzpatrick Skin Type I 9 – Very Light Skin, Fitzpatrick Skin Type I 10 – Very Light Skin, Fitzpatrick Skin Type I 11 – Very Light Skin, Fitzpatrick Skin Type I 12 – High Power, Fitzpatrick Skin Type IOptima-518-Classic Active Optical Systems Optima 518 IPL LaserThe Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece: * Faster treatments – up to 0.5 Seconds Between pulses. * Real-time handpiece temperature control. * Contemporary and stylish design. * Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.Approvals * CE MDD Intl. Medical Standard * FDA U.S. Safety Standard * ISO-13485 Med. Production STD * IEC 60-601-1 Medical Safety STD * CFS Gov. Health Approval * CSA Can. & U.S. Safety App * TGA Australian health STD.
Essilor Mr Blue 2.0 Lens Edgers and TracerComplete Control of Lens Mounting
  • Optimal monitoring of all trajectories, irrespective of finishing materials or shapes
  • Absolute axis control thanks to hybrid edging technology: grinding + milling
  • Ideally suited for quality finishing even on highest base curves
  • Fast and accurate drilling with data acquired in a single operation
  • Automatic centering and blocking for simple operation
Unrivalled Ergonomics
  • Completely integrated functions without external peripheral devices
  • Vertical architecture with <Heads-up displays> for optimum comfort
  • Storage features ensure all accessories are within reach.
  • Intelligent interface adapts to the way you work.
Highest Quality Guaranteed Essilor Mr Blue 2.0 Lens Edgers and TracerPerfect Centering
  • Binocular 3-D tracing of full-rim frames up to base 9*
  • Automatic adjustment of centering data based on the frames’ 30D parameters*
Aesthetic and Robust Mountings
  • FIT-4-Frame technology with dedicated small wheel*
  • Drilling and grooving tools can be tilted up to 30o, making it safe to mount lenses of up to base 10. *Essilor patents and exclusives
Safe Process
  • Roughing cycle automatically adapts to the curves of lenses up to base 10, avoiding all risk of breakage
  • Bevel placement and shelf depth optimized for safe mounting without undue stress of lens
Aesthetically Pleasing and Easy-to-Mount Bevels
  • The bevel heights are adjustable to perfectly adjust to the thinnest grooves
  • The shelf bevel heights are optimized to follow the frame’s shape perfectly
  • The step bevel is particularly suited for sport eyeglasses with deep, rectangular or uneven groove profile
Mr Blue 2.0 is on the cutting edge of innovation – serving as a genuine ECP partner since its launch. Now featuring a whole range of new functions and even greater flexibility, Mr Blue is the perfect solution for demanding workshop.

Zeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD

Accessories
  •     The ZEISS Certified Factory Direct Cirrus 4000 HD-OCT also includes the full Accessory Kit
  •     External Fixation Light
  •     Test Eye
  •     Mini Keyboard
  •     Optical Mouse
  •     Dust Cover
  •     Metric 5A/250v Fuse
  •     14 Ft. CAT 5e Network Cable
  •     USB Cable
  •     IEC 320 to NEMA 12 inch Power Cable
  •     IEC 320 39in. Power Cable
  •     Install Disc including Roxio Basic
  •     Symbol Sheet
  •     OCT Primer Guide
  •     Quick Start Guide
HD-OCT Imaging
  • Methodology: Spectral Domain OCT
  • Optical Source: superluminescent diode (SLD), 840 nm
  • Optical Power: < 725 μW at the cornea
  • Scan Speed: 27,000 A-scans per second
  • A-Scan depth: 2.0 mm (in tissue), 1024 points
  • Axial resolution: 5 μm (in tissue)
  • Transverse resolution: 15 μm (in tissue)
Fundus Imaging
  • Methodology: Line scanning ophthalmoscope
  • Live Fundus Image: During alignment and during OCT scan
  • Optical Source: Superluminescent diode (SLD), 750 nm
  • Optical Power: < 1.5 mW at the cornea
  • Field of View: 36 degrees W x 30 degrees H
  • Frame rate: >20 Hz
  • Transverse resolution: 25 μm (in tissue)
Iris Imaging
  • Methodology: CCD Camera
  • Resolution: 1280 x 1024
  • Live iris image: During alignment
Electrical, Physical and Environmental
  • Weight: 38kg (83 lbs)
  • Dimensions: 65L x 44W x 53H (cm)
  • Fixation: Internal, external
  • Internal fixation focus adjustment: -20D to +20D (diopters)
  • Input devices: Keyboard, mouse
  • Electrical rating (115V) Single Phase, 100/120V~ systems:50-60Hz, 5A
  • Fuse rating (115V) T 5A 250V
  • Electrical rating (230V) Single Phase, 220/240V~ systems:50-60 Hz, 2.5A
  • Fuse rating (230V) Fuse rating: T 5A 250V
  • Convenience Receptacle output ratings 115V~, 0.5 A Max, 50-60 Hz
  • Temperature (transport and storage) -40º to +70º C
  • Relative humidity (transport and storage) 10% to 100%, including condensation
  • Atmospheric pressure (transport and storage): 500 hPa to 1060 hPa
  • Temperature (operation) +10º to +35º C
  • Relative humidity (operation) 30% to 75%, excluding condensation
  • Atmospheric Pressure (operation) 700 hPa to 1060 hPa
Computer Zeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD
  • • High performance multi-core processor
  • • Internal storage: > 80,000 scans
  • • CD-RW, DVD-ROM drive
  • • Integrated 15″ color flat panel display.
The Cirrus HD-OCT is a non-contact, high resolution tomographic and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures, including cornea, retina, retinal nerve fiber layer, ganglion cell plus inner plexiform layer, macula, and optic nerve head. The Cirrus normative databases are quantitative tools for the comparison of retinal nerve fiber layer thickness, macular thickness, ganglion cell plus inner plexiform layer thickness, and optic nerve head measurements to a database of normal subjects. The Cirrus HD-OCT is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration, and glaucoma.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: Tomey RC-5000 Auto Refractor Keratometer For Sale $4,800.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Shopping cart close