PERKASA MEDICAL

Free shipping worldwide. Orders over $200
Availability: In Stock

Tomey RC-5000 Auto Refractor Keratometer For Sale

$4,800.00

The Tomey RC-5000 has highly accurate measurement combined with short examination time and ease of use, makes working with the Tomey RC-5000 Autorefractor Keratometer both professional and quick. The advanced touch-screen display allows you to perform both refraction and keratometry automatically with one simple movement, capture one eye on the display and the Tomey RC-5000 will do both eyes automatically. With the new features, the Tomey RC-5000 Autorefractor Keratometer will surely make your office more efficient.

Other people want this. 15 people have this in their carts right now.

Description

Tomey RC-5000 Auto Refractor Keratometer

Tomey RC-5000 Refractometry

Normal Mode:

-Fogging is applied automatically for each measurement for more Accurate Results

Quick Mode:

-Fogging is applied as needed for consecutive measurements.

IOL/CAT Mode:

-This mode is used to measure cataract or pseudophakic eyes.

Keratometry:

-Short consecutive measurements and time provide reliable data.
-Measurements at 6.00mm (R=8.0mm) as well as at 3.00mm give you enough information for contact lens fitting.
-base curves of contact lenses are stored, categorized and suggested manufacturers are automatically printed.

Diameter Measurements of Cornea and Pupil:

-Measurement can be done easily by moving the two cursors on the display to the boundary of cornea or pupil. This is useful for deciding the diameter of a contact lens and for other contact lens fitting practice.

Power Joystick:

-Move the joystick ring up/down and the instrument head moves up/down quickly.
-Move the joystick hand rest to the right/left or backward/forward and the instrument head moves to the right/left or backward/forward quickly.
-Rotate the joystick ring and the instrument head moves up/down slowly.
-Tilt the joystick and the instrument head moves in each direction slowly.

Power Chinrest:

-The chin rest can be moved by pushing the buttons on the front panel. No need to reach out to the chin rest for manual adjustments.

Autorefractor Keratometer Features:

Refractometory : Tomey RC-5000 Auto Refractor Keratometer

-Sphere 25.00 to +22.00D (VD =12.00mm) Cylinder -10.00 to +10.00D (VD = 12.00mm)
-Axis 0 to 180 Degree
-Minimum Pupil Dia. 2.2mm
-Measurements Time 0.2 Sec.

Keratometry :

-Range 5.00mm to 11.00mm
-Corneal Refraction 30.68D to 67.50D (n = 1.3375)
-Corneal Astigmatism 0D to 10D (n = 1.3375)
-Axis 0 to 180 Degree
-Measured Area 3.0mm / 6.0 mm
-Measured Time 0.1 Sec PD
-Measurement Yes (50 to 86mm)
-Diameter Measuremnt of Cornea & Pupil 1.0 to 14.0mm
-Chinrest : Power Chin Rest
-Printer : High Speed Thermal Line Printer
-OutputPort RS-232C
-Power Requirements: AC 100V to 240V
-50/60Hz 130VA

Reviews

There are no reviews yet.

Be the first to review “Tomey RC-5000 Auto Refractor Keratometer For Sale”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsTomey RC-5000 Auto Refractor Keratometer For Sale removeEzer ERK-7800 Autorefractor Keratometer For Sale removeNidek RS-330 Retina Scan Duo 2 with FAF removeTomey RC-800 Auto Refractor Keratometer For Sale removeNew ZEISS CIRRUS 6000 – 100 kHz OCT Imaging System removeZeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD remove
NameTomey RC-5000 Auto Refractor Keratometer For Sale removeEzer ERK-7800 Autorefractor Keratometer For Sale removeNidek RS-330 Retina Scan Duo 2 with FAF removeTomey RC-800 Auto Refractor Keratometer For Sale removeNew ZEISS CIRRUS 6000 – 100 kHz OCT Imaging System removeZeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD remove
Image
SKU
Rating
Price $4,800.00 $3,300.00 $3,150.00 $3,700.00 $7,200.00 $4,500.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

DescriptionThe Tomey RC-5000 has highly accurate measurement combined with short examination time and ease of use, makes working with the Tomey RC-5000 Autorefractor Keratometer both professional and quick. The advanced touch-screen display allows you to perform both refraction and keratometry automatically with one simple movement, capture one eye on the display and the Tomey RC-5000 will do both eyes automatically. With the new features, the Tomey RC-5000 Autorefractor Keratometer will surely make your office more efficient.Ezer ERK-7800 Auto Refractor/KeratometerConfidently measure the human eye with a sophisticated cutting edge technology designed to enhance your ability to diagnose ocular errors faster, easier, and accurately. Ezers ERK-7800 is brilliantly designed technology measures the eye with ultra precision and speed to provide reliable data as the starting point of your refraction and contact lens fitting. It’s compact and modern design enables seamless operation and an enhanced patient comfort, making it the ideal choice in for any ophthalmic practice. Backed by an industry leading 2-years warranty!
The Nidek RS-330 OCT is a combination of a High-Definition OCT and fundus camera. Optional delivery with FAF (Auto-fluorescence function)
The Auto “Refkeratometer” RC-800 is the latest in economical, user-friendly, highly accurate auto “refkeratometry”. The RC-800 provides simple, easy measurement by the operator at an economical cost, without compromising accuracy or reliability.
Performance OCT. 100,000 scans per second to power your practice.
CIRRUS  6000 is the next-generation OCT from ZEISS, delivering high-speed image capture with HD imaging detail and a wider field of view so you can make more informed decisions and spend more time with the patients who need it.Learn how you can maximize patient throughput and practice efficiency with ZEISS CIRRUS 6000.
The Cirrus HD-OCT is a non-contact, high resolution tomographic and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures, including cornea, retina, retinal nerve fiber layer, ganglion cell plus inner plexiform layer, macula, and optic nerve head. The Cirrus normative databases are quantitative tools for the comparison of retinal nerve fiber layer thickness, macular thickness, ganglion cell plus inner plexiform layer thickness, and optic nerve head measurements to a database of normal subjects. The Cirrus HD-OCT is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration, and glaucoma.
Content

Tomey RC-5000 Auto Refractor Keratometer

Tomey RC-5000 RefractometryNormal Mode:-Fogging is applied automatically for each measurement for more Accurate ResultsQuick Mode:-Fogging is applied as needed for consecutive measurements.IOL/CAT Mode:-This mode is used to measure cataract or pseudophakic eyes.Keratometry:-Short consecutive measurements and time provide reliable data. -Measurements at 6.00mm (R=8.0mm) as well as at 3.00mm give you enough information for contact lens fitting. -base curves of contact lenses are stored, categorized and suggested manufacturers are automatically printed.Diameter Measurements of Cornea and Pupil:-Measurement can be done easily by moving the two cursors on the display to the boundary of cornea or pupil. This is useful for deciding the diameter of a contact lens and for other contact lens fitting practice.Power Joystick:-Move the joystick ring up/down and the instrument head moves up/down quickly. -Move the joystick hand rest to the right/left or backward/forward and the instrument head moves to the right/left or backward/forward quickly. -Rotate the joystick ring and the instrument head moves up/down slowly. -Tilt the joystick and the instrument head moves in each direction slowly.Power Chinrest:-The chin rest can be moved by pushing the buttons on the front panel. No need to reach out to the chin rest for manual adjustments.Autorefractor Keratometer Features:Refractometory : Tomey RC-5000 Auto Refractor Keratometer-Sphere 25.00 to +22.00D (VD =12.00mm) Cylinder -10.00 to +10.00D (VD = 12.00mm) -Axis 0 to 180 Degree -Minimum Pupil Dia. 2.2mm -Measurements Time 0.2 Sec.Keratometry :-Range 5.00mm to 11.00mm -Corneal Refraction 30.68D to 67.50D (n = 1.3375) -Corneal Astigmatism 0D to 10D (n = 1.3375) -Axis 0 to 180 Degree -Measured Area 3.0mm / 6.0 mm -Measured Time 0.1 Sec PD -Measurement Yes (50 to 86mm) -Diameter Measuremnt of Cornea & Pupil 1.0 to 14.0mm -Chinrest : Power Chin Rest -Printer : High Speed Thermal Line Printer -OutputPort RS-232C -Power Requirements: AC 100V to 240V -50/60Hz 130VA

Ezer ERK-7800 Autorefractor KeratometerFeatures of the ERK-7800 Auto Refractor/Keratometer ▪ Auto Refractor/Keratometer ▪ Enhanced Retro-illumination Imaging ▪ Accurate Measurement of Iris & Pupils Diameters ▪ Precise Temperature Sensor Compensation ▪ Enhanced Measuring Speed ▪ Comfortable Motorized Chin Rest ▪ Automatic High Speed Cutting Printer ▪ Simple One Touch Lock Knob ▪ 20 Touch & Tilt Color Monitor Display ▪ Sophisticated TFT LCD Graphic User Interface ▪ Easy Network Capability ▪ Backed by an Industry Leading 2-years Warranty! ▪ Auto Refractor/Keratometer The ERK-7800 instantly reports the patient’s assessed eye power by combining the Auto Refractor/Keratometer functions into this one sharp instrument, making measurement a snap. This determines the refractive and keratometric properties of the human eye to assist eye care professionals in the process of prescribing corrective eyeglasses and contact lenses.▪ Keratometry and Refractometry (RK Mode)▪ Enhanced Retro-illumination Imaging Ezer ERK-7800 Autorefractor Keratometer With the Enhanced Retro-illumination Imaging capability in the ERK-7800, you can treat and see abnormal crystalline lenses, cataracts, and scratches of corneas helping you to determine how healthy the patients eyes are with better clarity. This allows for observation of the eye condition of the cataract or contact lens surface. The system saves up to 2 images of each eye.▪ Accurate Measurement of Iris & Pupils Diameters The corneal diameter and base curve of contact lenses can be measured with this one instrument. Therefore, measurements of eye and prescriptions for glasses and contact lenses can be made more efficiently.▪ Measuring Cornea Size (SIZE MODE)▪ Wide Dioptric Measurement Range Because the ERK-7800 covers a wide measurement range from -25D to +22D, even an examinee with strong myopia can be measured. ▪ Enhanced Measuring Speed Specially designed image chips have succeeded to make REF measuring speed faster reducing the overall examination time and increases throughput for complete examinations.▪ Comfortable Motorized Chin Rest Simply by pressing up/down buttons, user can set the height of measuring point comfortably. With the cutting edge auto sensor mechanism, you can track down, measure and focus the eye with out ever making a mistake.▪ Automatic Printer Paper Cut The printer is designed to execute, print, & cut data automatically at high speed for immediate results.▪ Simple One Touch Lock Knob With just the touch of a single button, the main body can easily be locked to its base.▪ 20 Degrees Tilted LCD Monitor The LCD Monitor tilts up to 20 degrees; a design made for comfort making. Excellent ergonomics makes it possible to operate the ERK-7800 while standing or sitting, for added convenience.▪ Sophisticated TFT LCD Graphic User Interface Sharp images with easy to understand icons make this 6.4-inch color TFT LCD interface user-friendly and enjoyable to work with.

Nidek RS-330 Retina Scan Duo 2 with FAF

The Retina Scan Duo 2 is a combined OCT and fundus camera system that incorporates new features enhancing screening and clinical efficiency in addition to user-friendly features that were incorporated from the previous model.FEATURES : Nidek RS-330 Retina Scan Duo 2 with FAF
  • Fundus image acquisition with macula and disc capture in one image on OCT
  • Combined diagnosis of macular and disc pathologies
  • Wide area scan (12 x 9 mm) Wide area normative database (macula: 9 x 9 mm, disc: 6 x 6 mm): A 12 x 9 mm wide area image can be acquired. The retina map captures both the macula and disc in a single shot. The normative database provides a wide area color-coded map comparing the patient’s macular thickness to a population of normal eyes.
  • Denoising technique with deep learning: A new image enhancement technique using deep learning automatically displays a denoised image once B-scan acquisition is complete. With deep learning of a large data set of images averaged from 120 images, this denoising technique provides high definition images comparable to a multiple-image-averaging technique. The denoising function generates high definition images from a single frame while decreasing image acquisition time and increasing patient comfort.
  • Quick acquisition of high definition B-scan images from a single-frame image
  • Fundus autofluorescence (FAF): The FAF function is an advanced screening feature that allows non-invasive evaluation of the RPE without contrast dye. *Available for the FAF model
Nidek RS-330 Retina Scan Duo 2– Easy operation with 3-D auto tracking, auto shot, and user friendly interface – High definition images – Wide area scan (12 x 9 mm) / Wide area normative database (9 x 9 mm) – Multiple OCT scan patterns – Value added features – Various reports
Nidek High speed image capture OCT images are captured at scan speeds of 70,000 A-scans/s which is 32% faster than acquisition with the Retina Scan Duo™ using Regular OCT sensitivity*Wide area scan (12 x 9 mm) Wide area normative database (macula: 9 x 9 mm, disc: 6 x 6 mm) A 12 x 9 mm wide area image can be acquired. The retina map captures both the macula and disc in a single shot. The normative database provides a wide area color-coded map comparing the patient’s macular thickness to a population of normal eyes.Denoising using deep learning A new image enhancement technique using deep learning automatically displays a denoised image once B-scan acquisition is complete. With deep learning of a large data set of images averaged from 120 images, this denoising technique provides high definition images comparable to a multiple-image-averaging technique. The denoising function generates high definition images from a single frame while decreasing image acquisition time and increasing patient comfort

Tomey RC-800 Auto Refractor Keratometer

Refractometry: Simple handling of the fine adjustment and measurement by yourself. Fogging is applied automatically for each measurement for more accurate results.Keratometry: Short consecutive measurements and time provide reliable data. Measurements at φ3.0mm (R = 8.0mm) give you enough information for contact lens fitting.Diameter Measurement of Cornea and Pupil: Easy measurement by moving the two cursors on the display to the boundaries of Cornea or Pupil.Language Selection: RC-800 has a Multi-language function. You can select your required language from “English”, “Japanese”, “German”, “Chinese”, “Spanish”, “Spanish Latin America”, “Italian”, “Portuguese”, “French” and “Russian”.Features:• Highly Accurate • Simple to Use • Diameter Measurement of Cornea and Pupil • High Speed Printer • Auto Shot • Color Touch Screen • USB connection • Large Patient Database • Easy Database Operation • Multi-Language Operation • Fourier Refractive Analysis • Quick Data Reference • Built-in LCD Alignment • Keratoconus Screening & Other ApplicationsMeasurement Ranges:Refraction:• Sphere: -25.00D to +22.00D (VD=12.0mm) • Cylinder: 0D to ±10.00D (VD=12.0mm) • Axis: 0° to 180° • Minimum Pupil Dia: Ø2.0mm • Measurement time: 0.2 second/single eye (data taking time)Keratometry:• Range: 5.00mm to 11.00mm • Corneal Refraction: 30.68D to 67.50D (n=1.3375) • Corneal Astigmatism: 0D to 10D (n=1.3375) • Axis: 0° to 180° • Measurement area: Ø3mm (at 8.00mm corneal curvature) • Measurement time: 0.1 second/single eye (data taking time)Other features:Tomey RC-800 Auto Refractor Keratometer• PD Measurement range 50 to 86mm • Corneal diameter measurement • Measurement range: 10.0 to 14.0mm • Display unit: 0.1mm • Pupil diameter measurement • Measurement range: 1.0 to 10.0 mm • Display unit: 0.1mm • Built-in Printer Thermal printer • Data output type RS232C / USB-D • Display 5.7 inch color liquid crystal display • Dimensions and weight 297(W)x 500(D) x 448(H)mm • Approx. 17kg • Power Requirements AC 100V to 240V, 50 / 60 Hz, 80VA to 100VAThe Auto “Refkeratometer” RC-800 is the latest in economical, user-friendly, highly accurate auto “refkeratometry”. The RC-800 provides simple, easy measurement by the operator at an economical cost, without compromising accuracy or reliability.

New ZEISS CIRRUS 6000 – 100 kHz OCT Imaging System
Faster, wider with a new level of detail
At 100,000 scans per second, ZEISS CIRRUS 6000 enables clinicians to image a larger field of view up to 12mm in a single scan. It also captures high-defintion (HD) OCT and OCT Angiography (OCTA) scans, revealing the finer microvascular details of the retina and providing more insight into your patient’s condition.
Making the revolutionary, routine.ZEISS AngioPlex OCT Angiography New ZEISS CIRRUS 6000 – 100 kHz OCT Imaging System
AngioPlexOCT Angiography from ZEISS ushers in a new era of eye care with non-invasive imaging of retinal microvasculature—taking glaucoma and retinal disease management and treatment planning to the next level. By offering the industry’s most comprehensive tools for assessing and analyzing a range of pathologies, ZEISS provides a complete OCT Angiography (OCTA) solution.
CIRRUS 6000 is the latest addition to an already robust portfolio of OCT devices that are designed to meet the needs of all types and levels of practices and/or clinicians. It offers customers high-speed and high-throughput to help manage their large patient volume faster, all while improving imaging and image quality.
“This system was designed with the patient in mind, enabling doctors to continue accessing their patient data from CIRRUS devices that are crucial to effective long-term patient care,” said Jim Mazzo, Global President of Ophthalmic Devices at Carl Zeiss Meditec. “We are committed to our customers and believe this will become an essential asset to their practice.”The 100kHz speed of the CIRRUS 6000 allows clinicians to scan patients faster, with increased efficiency and improved imaging detail. Additional features include:
  • Wider and deeper OCT/OCTA scans with 12x12mm OCTA and B-scan depth up to 2.9mm
  • HD AngioPlex scan is a new scan type that provides more detail
  • New workflow protocols to aid in increasing efficiency
  • Patient-friendly “Wellness report” to help educate the patient
According to retina and vitreoretinal physician and surgeon Gregg T. Kokame, MD, of Retina Consultants of Hawaii, the new ZEISS CIRRUS 6000 is extremely fast and impressive. “With the new scan acquisition time of 100,000 per second I can scan and assess my patients much quicker, giving me the details I need with every image,” says Kokame.“ZEISS is dedicated to advancing eye care through development of new and innovative solutions, like the CIRRUS 6000,” said Dr. Ludwin Monz, President and CEO of Carl Zeiss Meditec AG. “With our comprehensive diagnostics portfolio, we will continue to create better vision standards to benefit patients today and in the future.”

Zeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD

Accessories
  •     The ZEISS Certified Factory Direct Cirrus 4000 HD-OCT also includes the full Accessory Kit
  •     External Fixation Light
  •     Test Eye
  •     Mini Keyboard
  •     Optical Mouse
  •     Dust Cover
  •     Metric 5A/250v Fuse
  •     14 Ft. CAT 5e Network Cable
  •     USB Cable
  •     IEC 320 to NEMA 12 inch Power Cable
  •     IEC 320 39in. Power Cable
  •     Install Disc including Roxio Basic
  •     Symbol Sheet
  •     OCT Primer Guide
  •     Quick Start Guide
HD-OCT Imaging
  • Methodology: Spectral Domain OCT
  • Optical Source: superluminescent diode (SLD), 840 nm
  • Optical Power: < 725 μW at the cornea
  • Scan Speed: 27,000 A-scans per second
  • A-Scan depth: 2.0 mm (in tissue), 1024 points
  • Axial resolution: 5 μm (in tissue)
  • Transverse resolution: 15 μm (in tissue)
Fundus Imaging
  • Methodology: Line scanning ophthalmoscope
  • Live Fundus Image: During alignment and during OCT scan
  • Optical Source: Superluminescent diode (SLD), 750 nm
  • Optical Power: < 1.5 mW at the cornea
  • Field of View: 36 degrees W x 30 degrees H
  • Frame rate: >20 Hz
  • Transverse resolution: 25 μm (in tissue)
Iris Imaging
  • Methodology: CCD Camera
  • Resolution: 1280 x 1024
  • Live iris image: During alignment
Electrical, Physical and Environmental
  • Weight: 38kg (83 lbs)
  • Dimensions: 65L x 44W x 53H (cm)
  • Fixation: Internal, external
  • Internal fixation focus adjustment: -20D to +20D (diopters)
  • Input devices: Keyboard, mouse
  • Electrical rating (115V) Single Phase, 100/120V~ systems:50-60Hz, 5A
  • Fuse rating (115V) T 5A 250V
  • Electrical rating (230V) Single Phase, 220/240V~ systems:50-60 Hz, 2.5A
  • Fuse rating (230V) Fuse rating: T 5A 250V
  • Convenience Receptacle output ratings 115V~, 0.5 A Max, 50-60 Hz
  • Temperature (transport and storage) -40º to +70º C
  • Relative humidity (transport and storage) 10% to 100%, including condensation
  • Atmospheric pressure (transport and storage): 500 hPa to 1060 hPa
  • Temperature (operation) +10º to +35º C
  • Relative humidity (operation) 30% to 75%, excluding condensation
  • Atmospheric Pressure (operation) 700 hPa to 1060 hPa
Computer Zeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD
  • • High performance multi-core processor
  • • Internal storage: > 80,000 scans
  • • CD-RW, DVD-ROM drive
  • • Integrated 15″ color flat panel display.
The Cirrus HD-OCT is a non-contact, high resolution tomographic and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures, including cornea, retina, retinal nerve fiber layer, ganglion cell plus inner plexiform layer, macula, and optic nerve head. The Cirrus normative databases are quantitative tools for the comparison of retinal nerve fiber layer thickness, macular thickness, ganglion cell plus inner plexiform layer thickness, and optic nerve head measurements to a database of normal subjects. The Cirrus HD-OCT is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration, and glaucoma.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: Tomey RC-5000 Auto Refractor Keratometer For Sale $4,800.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Shopping cart close