PERKASA MEDICAL

Free shipping worldwide. Orders over $200
Availability: In Stock

Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD

$6,950.00

CIRRUS HD-OCT 5000 is configured with the highest resolution visualization capabilities and sophisticated clinical applications such as Advanced RPE analysis to track retinal pigment epithelial integrity and Ganglion Cell Analysis to assess glaucomatous loss in the macula that may not be evident in the peripapillary region. The new FastTrac  retinal tracking reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning. This feature enables the highest resolution B-Scans to be captured in identical locations from visit to visit providing precise assessment of change in targeted pathologies.

Other people want this. 15 people have this in their carts right now.

Description

Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD

Advancing Smart OCT

for Anterior Segment, Glaucoma and Retina
  • Anterior Segment Premier Module
  • PanoMap Wide-Field Display
  • Smart HD Scans
  • En face report
Measurement centering with Foveafinder

Visualization at the speed of CIRRUS

Analyzing a single pathology from multiple views provides comprehensive insight and analysis of the clinical situation. How this helps you:

  • Spot small areas of pathology. Tightly spaced B-scans, (either 30 or 47 μm apart), in the cube ensure that small areas of pathology are imaged. For reference, a human hair is about 40-120 μm in diameter.
  • Visualize the fovea. Scans that are spaced further apart than in the CIRRUS cube may miss the central fovea.
  • Fuel for analysis. Millions of data points from the cube are fed into the Zeiss proprietary algorithms for accurate segmentation, reproducible measurements and registration for change analysis.
  • Take the pressure off the operator. As long as the scan is placed in the vicinity of the fovea or optic nerve, the software automatically centers the measurements after the capture.
  • See the tissue from different perspectives. View the cube data from all angles, with 3D rendering, OCT fundus images and Advanced Visualization™.
  • Future ready. Previously captured CIRRUS cubes can be analyzed using new analyses.

 

Measurement centering with Foveafinder

Tracking at the speed of CIRRUS

FastTrac™ reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning
With FastTrac, scan at the highest resolution at the same location at each visit.

Watch video
Measurement centering with Foveafinder

Assessment at the speed of CIRRUS

Measurement centering with FoveaFinder and AutoCenter

On the macula, the unique FoveaFinder technology ensures the ETDRS and ganglion cell plus inner plexiform layer measurement frameworks are centered on the fovea.

AutoCenter™ function automatically centers the 3.4 mm diameter peripapillary RNFL calculation circle around the disc for precise placement and repeatable registration. The placement of the circle is not operator dependent. Accuracy, registration and reproducibility are assured.

Measurement centering with Foveafinder

Manage at the speed of CIRRUS Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD

Guided Progression Analysis (GPA™) for Assessing RNFL and Optic Disc Change

GPA™ compares RNFL thickness and optic disc measurements over time and determines if statistically significant change has occurred.

Focal Progression Analysis – Up to 6 progression maps are compared to two baselines. Areas of statistically significant change are color-coded yellow when first noted and then red when the change is sustained over consecutive visits.
Trend Analysis with Rate of Change – RNFL thickness values are plotted over time. Trends are calculated and confidence intervals are shaded when rate of change is statistically significant.

 

Reviews

There are no reviews yet.

Be the first to review “Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsCarl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD removeCutera Enlighten III Pico-Nano Second Tattoo Removal For Sale removeCarestream Vita 25 Digital CR System For Sale removeEzer ERK-7800 Autorefractor Keratometer For Sale removeActive Optical Systems Optima 518 IPL Laser removeHuvitz HRK-8000A Auto Refractor Keratometer For Sale remove
NameCarl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD removeCutera Enlighten III Pico-Nano Second Tattoo Removal For Sale removeCarestream Vita 25 Digital CR System For Sale removeEzer ERK-7800 Autorefractor Keratometer For Sale removeActive Optical Systems Optima 518 IPL Laser removeHuvitz HRK-8000A Auto Refractor Keratometer For Sale remove
Image
SKU
Rating
Price $6,950.00 $9,500.00 $9,800.00 $3,300.00 $5,200.00 $3,500.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

DescriptionCIRRUS HD-OCT 5000 is configured with the highest resolution visualization capabilities and sophisticated clinical applications such as Advanced RPE analysis to track retinal pigment epithelial integrity and Ganglion Cell Analysis to assess glaucomatous loss in the macula that may not be evident in the peripapillary region. The new FastTrac  retinal tracking reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning. This feature enables the highest resolution B-Scans to be captured in identical locations from visit to visit providing precise assessment of change in targeted pathologies.Recommended for all skin types, the PicoGenesis laser procedure is used to treat:• Brown spots • Sun damage • Age spots • Melasma • Hyperpigmenation • Pigmented lesionsProviding high-quality diagnostic imaging services to your patients is high on your list of priorities. But there are limits to your budget and your space. That’s why we are excited to offer your customers the CARESTREAM DIRECTVIEW Vita CR System—a reliable, compact, tabletop imaging solution with a small footprint and light weight design. It allows seamless integration into your existing work flow, and helps increase efficiency and productivity, all at an affordable price.Ezer ERK-7800 Auto Refractor/KeratometerConfidently measure the human eye with a sophisticated cutting edge technology designed to enhance your ability to diagnose ocular errors faster, easier, and accurately. Ezers ERK-7800 is brilliantly designed technology measures the eye with ultra precision and speed to provide reliable data as the starting point of your refraction and contact lens fitting. It’s compact and modern design enables seamless operation and an enhanced patient comfort, making it the ideal choice in for any ophthalmic practice. Backed by an industry leading 2-years warranty!New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece: * Faster treatments – up to 0.5 Seconds Between pulses. * Real-time handpiece temperature control. * Contemporary and stylish design. * Light weight design – 25% less weight to improve the therapists’ comfort.The image can then be displayed on a monitor, helping you to educate your patients The HRK can provide peripheral keratometry measurement data which is very useful when fitting contact lenses. The eye can be displayed in full colour mode on a tilting touch screen which enables you to see the patient’s contact lens fitting status, previously only possible using a slit lamp. As the HRK has the world’s first contact lens fitting function in an auto keratometer, you can now see the flourescein liquid with blue illumination along with automatic calculation and recommendation for contact lens fitting.
ContentCarl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD

Advancing Smart OCT

for Anterior Segment, Glaucoma and Retina
  • Anterior Segment Premier Module
  • PanoMap Wide-Field Display
  • Smart HD Scans
  • En face report
Measurement centering with Foveafinder

Visualization at the speed of CIRRUS

Analyzing a single pathology from multiple views provides comprehensive insight and analysis of the clinical situation. How this helps you:
  • Spot small areas of pathology. Tightly spaced B-scans, (either 30 or 47 μm apart), in the cube ensure that small areas of pathology are imaged. For reference, a human hair is about 40-120 μm in diameter.
  • Visualize the fovea. Scans that are spaced further apart than in the CIRRUS cube may miss the central fovea.
  • Fuel for analysis. Millions of data points from the cube are fed into the Zeiss proprietary algorithms for accurate segmentation, reproducible measurements and registration for change analysis.
  • Take the pressure off the operator. As long as the scan is placed in the vicinity of the fovea or optic nerve, the software automatically centers the measurements after the capture.
  • See the tissue from different perspectives. View the cube data from all angles, with 3D rendering, OCT fundus images and Advanced Visualization™.
  • Future ready. Previously captured CIRRUS cubes can be analyzed using new analyses.
 
Measurement centering with Foveafinder

Tracking at the speed of CIRRUS

FastTrac™ reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning With FastTrac, scan at the highest resolution at the same location at each visit.
Watch video
Measurement centering with Foveafinder

Assessment at the speed of CIRRUS

Measurement centering with FoveaFinder and AutoCenter
On the macula, the unique FoveaFinder technology ensures the ETDRS and ganglion cell plus inner plexiform layer measurement frameworks are centered on the fovea.AutoCenter™ function automatically centers the 3.4 mm diameter peripapillary RNFL calculation circle around the disc for precise placement and repeatable registration. The placement of the circle is not operator dependent. Accuracy, registration and reproducibility are assured.
Measurement centering with Foveafinder

Manage at the speed of CIRRUS Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD

Guided Progression Analysis (GPA™) for Assessing RNFL and Optic Disc Change
GPA™ compares RNFL thickness and optic disc measurements over time and determines if statistically significant change has occurred.Focal Progression Analysis – Up to 6 progression maps are compared to two baselines. Areas of statistically significant change are color-coded yellow when first noted and then red when the change is sustained over consecutive visits. Trend Analysis with Rate of Change – RNFL thickness values are plotted over time. Trends are calculated and confidence intervals are shaded when rate of change is statistically significant.
 
Cutera Enlighten III Pico-Nano Second Tattoo RemovalThis next-generation PicoGenesis laser is an advanced, non-thermal way to treat pigmentary concerns, PicoGenesis harnesses a non-thermal, photomechanical effect paired with ultra-short—one trillionth of a second long—pulse durations. The perfect blend of technologies creates shockwaves that shatter pigments in the skin without damaging the surrounding tissue, while inducing dermal disruption and remodelling for true skin revitalisation.Unlike conventional laser toning that requires up to 15 treatment sessions and often lead to adverse side effects such as redness, swelling and itching. Thanks to the incorporated picosecond technology, in as few as three sessions you will experience a dramatic improvement in the reduction of pigmentation as well as a brighter, more uniform complexion in just 20 minutes—and all with no downtime! With entirely changeable parameters, this game-changing treatment an be used to benefit even the most challenging skin concerns, and can also effectively remove all colours of tattoos.Recommended for all skin types, the PicoGenesis laser procedure is used to treat : Cutera Enlighten III Pico-Nano Second Tattoo Removal• Brown spots • Sun damage • Age spots • Melasma • Hyperpigmenation • Pigmented lesions
enlighten III combines multiple wavelengths (1064 nm, 532 nm and 670 nm) and picosecond + nanosecond pulse durations (750/660 ps + 2 ns) in a single platform for the treatment of unwanted multicolor tattoos, epidermal and dermal pigment, and skin revitalization across all skin types.
Unlike conventional laser toning that require up to 15 treatment sessions and often lead to unpredictable results, PICO Genesis harnesses the power and flexibility of enlighten SR combined with its technical benefits in a dual delivery procedure to selectively shatter pigment and induce dermal disruption and remodeling for true skin revitalization in fewer than 3 sessions.“The enlighten laser system has been a game changer for my tattoo removal practice. I feel much more confident that we can deliver patients the results they have been wanting since laser tattoo removal was first invented.”
Carestream Vita 25 Digital CR SystemCARESTREAM Vita Flex CR Systems are designed for small-to-midsize hospitals, clinics and practices that need compact digital solutions at an affordable price. With two options for throughput speed, Vita computed radiography systems offer in-house, high-quality digital imaging to fit your workflow. The flexible orientation makes it perfect for small spaces in offices or in mobile settings.System Beneits Smaller size and weight Multiple throughputs (30/45 PPH) Ability to be positioned for horizontal or vertical feeds Supports a number of cassette sizes Uses Image Suite Software – easy-to-use platform specially designed for the end userImage acquisition and management for CR and DR Systems Image Suite V4 Software has set a new benchmark for workflow efficiency in smaller facilities. This robust software features an easy-to-use, touch-friendly interface, an enhanced set of tools, streamlined workflow and improved image quality. Our advanced “mini-PACS” module allows superb image management and analysis, and is now fully optional. Get the high-quality images you need with a system that’s a perfect fit – at very affordable price.
Physical Specifications Carestream Vita 25 Digital CR System
• Weight: 25 kg (55 lb)
• Dimensions (W x D x H): 68.0 x 34.0 x 45.0 cm (26.7 x 13.4 x 17.7 in.)
Power
• Electrical Rating: 100-240 V AC 50/60 Hz
• Maximum Power Consumption: 120 W
• Power Consumption in Standby Mode: 42 W
• Power Supply Conditions: AC Power 100~240 V AC,50/60 Hz, 1.5 A
Kodak/Carestream Vita25 CR System:25 Plate Per Hour Reader 2, 14×17 Cassettes PC, Keyboard, Monitor, & Mouse Genesis Software 2 Year Warranty Available with the following upgrades:PACS: 250GB & 2 Viewers PACS: 450GB & 4 Viewers Go from 25 to 45 Plates Per Hour Additional 14×17 Cassettes Additional 10×12 Cassettes
Ezer ERK-7800 Autorefractor KeratometerFeatures of the ERK-7800 Auto Refractor/Keratometer ▪ Auto Refractor/Keratometer ▪ Enhanced Retro-illumination Imaging ▪ Accurate Measurement of Iris & Pupils Diameters ▪ Precise Temperature Sensor Compensation ▪ Enhanced Measuring Speed ▪ Comfortable Motorized Chin Rest ▪ Automatic High Speed Cutting Printer ▪ Simple One Touch Lock Knob ▪ 20 Touch & Tilt Color Monitor Display ▪ Sophisticated TFT LCD Graphic User Interface ▪ Easy Network Capability ▪ Backed by an Industry Leading 2-years Warranty! ▪ Auto Refractor/Keratometer The ERK-7800 instantly reports the patient’s assessed eye power by combining the Auto Refractor/Keratometer functions into this one sharp instrument, making measurement a snap. This determines the refractive and keratometric properties of the human eye to assist eye care professionals in the process of prescribing corrective eyeglasses and contact lenses.▪ Keratometry and Refractometry (RK Mode)▪ Enhanced Retro-illumination Imaging Ezer ERK-7800 Autorefractor Keratometer With the Enhanced Retro-illumination Imaging capability in the ERK-7800, you can treat and see abnormal crystalline lenses, cataracts, and scratches of corneas helping you to determine how healthy the patients eyes are with better clarity. This allows for observation of the eye condition of the cataract or contact lens surface. The system saves up to 2 images of each eye.▪ Accurate Measurement of Iris & Pupils Diameters The corneal diameter and base curve of contact lenses can be measured with this one instrument. Therefore, measurements of eye and prescriptions for glasses and contact lenses can be made more efficiently.▪ Measuring Cornea Size (SIZE MODE)▪ Wide Dioptric Measurement Range Because the ERK-7800 covers a wide measurement range from -25D to +22D, even an examinee with strong myopia can be measured. ▪ Enhanced Measuring Speed Specially designed image chips have succeeded to make REF measuring speed faster reducing the overall examination time and increases throughput for complete examinations.▪ Comfortable Motorized Chin Rest Simply by pressing up/down buttons, user can set the height of measuring point comfortably. With the cutting edge auto sensor mechanism, you can track down, measure and focus the eye with out ever making a mistake.▪ Automatic Printer Paper Cut The printer is designed to execute, print, & cut data automatically at high speed for immediate results.▪ Simple One Touch Lock Knob With just the touch of a single button, the main body can easily be locked to its base.▪ 20 Degrees Tilted LCD Monitor The LCD Monitor tilts up to 20 degrees; a design made for comfort making. Excellent ergonomics makes it possible to operate the ERK-7800 while standing or sitting, for added convenience.▪ Sophisticated TFT LCD Graphic User Interface Sharp images with easy to understand icons make this 6.4-inch color TFT LCD interface user-friendly and enjoyable to work with.Active Optical Systems Optima 518 IPL Laser
Handpiece (Standard):Multipurpose Wavelength Mark-II Handpiece (Optional):Facial Treatments Pulse Interval/Repetition Rate:0.5 – 2 Seconds Maximum Output Treatment Pattern:22 Joule /cm 2 Output Power:11-31 Joule / cm 2 , up to 4000 W Cooling System:Improved Air Cooling Control:Advanced Software Interface Lamp’s Life Span:200,000 Flashes (minimum) Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2) Wavelength:420 – 1,100 nm Weight:88.18 lbs (40Kg) (including stand) Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm) Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz Max Mains Power:600 VA Treatments Variety: Skin Rejuvenation Pigmentation Treatment Acne Treatment Hair Removal Hair Removal – Deep Follicles Hair Removal – Sensitive Skin Vascular (Facial) Treatment Tattoo Removal The Laser uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated. 12 Programs 1 – Very Dark Skin, Fitzpatrick Skin Type IV 2 – Dark Skin, Fitzpatrick Skin Type IV 3 – Dark Skin, Fitzpatrick Skin Type III 4 – Dark Skin, Fitzpatrick Skin Type III 5 – Medium Skin, Fitzpatrick Skin Type II 6 – Medium Skin, Fitzpatrick Skin Type II 7 – Light Skin, Fitzpatrick Skin Type II 8 – Light Skin, Fitzpatrick Skin Type I 9 – Very Light Skin, Fitzpatrick Skin Type I 10 – Very Light Skin, Fitzpatrick Skin Type I 11 – Very Light Skin, Fitzpatrick Skin Type I 12 – High Power, Fitzpatrick Skin Type IOptima-518-Classic Active Optical Systems Optima 518 IPL LaserThe Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece: * Faster treatments – up to 0.5 Seconds Between pulses. * Real-time handpiece temperature control. * Contemporary and stylish design. * Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.Approvals * CE MDD Intl. Medical Standard * FDA U.S. Safety Standard * ISO-13485 Med. Production STD * IEC 60-601-1 Medical Safety STD * CFS Gov. Health Approval * CSA Can. & U.S. Safety App * TGA Australian health STD.
Huvitz HRK-8000A Auto Refractor KeratometerHuvitz Auto Ref – Keratometer HRK-8000A
  • Touch and tilting 7″ LCD Screen that allows for free and smooth tilting for viewing at any angle.
  • Optimized Optical System
  • Micro Lens Array
  • Aberration Measurement which also can be displayed in a graphical Zernike Refraction Map
  • PSF & Image Simulation
  • Colour View Mode
  • Peripheral Keratometry Measurement
  • Ultra High Precision KER Data
  • Contact Lens Fitting Assistance Guide
  • Contact Lens Prescription Guide
  • Auto Tracking
  • Animated Guide
  • Faster Measurement Speed
  • Quiet and speedy auto cutting printer
  • More data on aberration measurement
With its extreme precision and accuracy, the HRK8000A uses the most advanced wavefront technology to measure the light reflected from the retina and helps you to diagnose any refractive error. With a micro lens array developed by Huvitz, the HRK creates a number of focal points, the pattern of which can give a valuable insight into the patients ocular system. The HRK not only displays the conventional data such as spherical, cylinder and axis, the high order aberration data is displayed in a graphical Zernike refractive map, giving you a deeper understanding of your patient’s eyes.Optimized Optical System Huvitz HRK-8000A Auto Refractor Keratometer A wavefront is a physical representation of the optical quality of a light beam. Using various methods, aberrometers map how light rays travel through the eye. The HR-8000A is engineered according to the Hartmann-Shack wavefront measurement technique, which is widely preferred for its speed and repeatability.Touch & Tilting Color Display Screen  A bright, high contrast 7″ VGA color TFT LCD screen provides high resolution video images. A smooth, free tilting function also offers you a comfortable and clear view at any angle.The image can then be displayed on a monitor, helping you to educate your patients The HRK can provide peripheral keratometry measurement data which is very useful when fitting contact lenses. The eye can be displayed in full colour mode on a tilting touch screen which enables you to see the patient’s contact lens fitting status, previously only possible using a slit lamp. As the HRK has the world’s first contact lens fitting function in an auto keratometer, you can now see the flourescein liquid with blue illumination along with automatic calculation and recommendation for contact lens fitting.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD $6,950.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Shopping cart close