| Description | CIRRUS HD-OCT 5000 is configured with the highest resolution visualization capabilities and sophisticated clinical applications such as Advanced RPE analysis to track retinal pigment epithelial integrity and Ganglion Cell Analysis to assess glaucomatous loss in the macula that may not be evident in the peripapillary region. The new FastTrac retinal tracking reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning. This feature enables the highest resolution B-Scans to be captured in identical locations from visit to visit providing precise assessment of change in targeted pathologies. | In recent years, the medical aesthetic industry has seen rapid growth in the number of body sculpting and body contouring procedures performed. The trend is projected to continue growing with the overall market growth of 16.3% year over year through 2020.Sculpting With Open ArmstruSculpt iD offers a unique and personalized approach to improve upper arm contouring and definition. Unlike other devices, there is no placement limitation, it is easy to set up, and fast to treat. Provide your patients improved freedom to open their arms and wear sleeveless shirts with confidence.- Unique approach to treat skin with laxity
- Sculpt challenging areas
- Synchronized treatment zones
- No downtime
| Superior, Comfortable Laser Hair RemovalLaser Hair Removal – An In-demand Procedureexcel HR combines a high-power 755 nm Alexandrite laser and Cutera’s proven long-pulse 1064 nm Nd:YAG laser for safe, effective high-volume hair removal on all skin types. The combination of wavelengths not only allows for effective hair removal, but is also a solution for epidermal pigmented lesions, vascular lesions and Cutera’s signature laser genesis skin revitalization procedure. | The NIDEK OPD-Scan II provides information on corneal topography, wavefront, autorefraction, keratometry and pupillometry in one unit, utilizing state-of-the-art imaging and analysis technology developed specifically to measure normal to highly aberrated eyes. The system offers a variety of data maps to provide information on the total refractive error, wavefront, corneal shape, internal aberrations and visual quality of the eye, allowing highly accurate and reliable information for optic diagnostics. | Providing high-quality diagnostic imaging services to your patients is high on your list of priorities. But there are limits to your budget and your space. That’s why we are excited to offer your customers the CARESTREAM DIRECTVIEW Vita CR System—a reliable, compact, tabletop imaging solution with a small footprint and light weight design. It allows seamless integration into your existing work flow, and helps increase efficiency and productivity, all at an affordable price. | The OPD-Scan III is an automated 5 in 1 instrument that combines topography, wavefront, autorefraction, keratometry, and pupillometry — allowing accurate and reliable analysis of corneal aberration. |
| Content | Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HDAdvancing Smart OCTfor Anterior Segment, Glaucoma and Retina- Anterior Segment Premier Module
- PanoMap Wide-Field Display
- Smart HD Scans
- En face report
Visualization at the speed of CIRRUSAnalyzing a single pathology from multiple views provides comprehensive insight and analysis of the clinical situation. How this helps you: - Spot small areas of pathology. Tightly spaced B-scans, (either 30 or 47 μm apart), in the cube ensure that small areas of pathology are imaged. For reference, a human hair is about 40-120 μm in diameter.
- Visualize the fovea. Scans that are spaced further apart than in the CIRRUS cube may miss the central fovea.
- Fuel for analysis. Millions of data points from the cube are fed into the Zeiss proprietary algorithms for accurate segmentation, reproducible measurements and registration for change analysis.
- Take the pressure off the operator. As long as the scan is placed in the vicinity of the fovea or optic nerve, the software automatically centers the measurements after the capture.
- See the tissue from different perspectives. View the cube data from all angles, with 3D rendering, OCT fundus images and Advanced Visualization™.
- Future ready. Previously captured CIRRUS cubes can be analyzed using new analyses.
Tracking at the speed of CIRRUSFastTrac™ reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning
With FastTrac, scan at the highest resolution at the same location at each visit. Assessment at the speed of CIRRUSMeasurement centering with FoveaFinder and AutoCenterOn the macula, the unique FoveaFinder technology ensures the ETDRS and ganglion cell plus inner plexiform layer measurement frameworks are centered on the fovea.AutoCenter™ function automatically centers the 3.4 mm diameter peripapillary RNFL calculation circle around the disc for precise placement and repeatable registration. The placement of the circle is not operator dependent. Accuracy, registration and reproducibility are assured. Manage at the speed of CIRRUS Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HDGuided Progression Analysis (GPA™) for Assessing RNFL and Optic Disc ChangeGPA™ compares RNFL thickness and optic disc measurements over time and determines if statistically significant change has occurred.Focal Progression Analysis – Up to 6 progression maps are compared to two baselines. Areas of statistically significant change are color-coded yellow when first noted and then red when the change is sustained over consecutive visits.
Trend Analysis with Rate of Change – RNFL thickness values are plotted over time. Trends are calculated and confidence intervals are shaded when rate of change is statistically significant.
| 2020 Cutera Trusculpt iD Monopolar RF Body ContouringPersonalized Body Sculpting:truSculpt iD is the latest body sculpting treatment solution from Cutera, providing a personalized, hands-free and hand-held solution to revolutionize your practice. This powerful, non-invasive, Monopolar RF platform tailors to patients’ individual needs and features Real-Time Temperature Control for clinically proven results, safety, and patient experience. truSculpt iD treats the entire fat layer, resulting in an average of 24% fat reduction.It offers unique handpiece and placement location versatility and customized 15-minute protocols to treat a full abdomen or multiple body areas simultaneously.Sculpting With Open ArmstruSculpt iD offers a unique and personalized approach to improve upper arm contouring and definition. Unlike other devices, there is no placement limitation, it is easy to set up, and fast to treat. Provide your patients improved freedom to open their arms and wear sleeveless shirts with confidence.- Unique approach to treat skin with laxity
- Sculpt challenging areas
- Synchronized treatment zones
- No downtime
Sculpting To Get A Leg Up
Thighs are commonly out of proportion with the rest of the lower body causing growing interest in leg sculpting. truSculpt iD offers an individualized and unmatched solution to regain proportion to inner and outer thighs of all shapes and sizes. Give your patients a leg up and the desire to flaunt their youthful shape.- Versatile to treat various tissue densities
- Tailored for areas large and small
- Flexible treatment configurations
- Immediately resume normal activities
truSculpt iD Technology
truSculpt iD provides an innovative RF technology that delivers clinically proven results to expand your body sculpting business. The system versatility allows for customized treatments to multiple body areas simultaneously based on patients need in as little as one 15-minute treatment protocol.Radiofrequency (RF) Energy
truSculpt iD delivers heat to the entire fat layer while maintaining a comfortable skin temperature – optimizing clinical efficacy and maintaining patient comfort. | Cutera Excel HR 1064 755 Hair Removal SystemAlexandrite
Wavelength:755 nm
Maximum Energy:53J
Pulse Duration:3 ms
Spot Size:5-18 mm
Repetition Rate:2 HzNd Yag
Wavelength:1064 nm
Maximum Energy:80J
Pulse Duration:0.1 – 300 ms
Spot Size:3-12 mm
Repetition Rate:Up to 10 Hz
Cooling:Contact Sapphire
Aiming Beam:635 nm
Dimensions:35″ H x 12″ W x 24″ D
Electricial:200-240 VAC, 50/60 Hz, 20A/30ACooling:Contact Sapphire
Aiming Beam:635 nm
Dimensions:35″ H x 12″ W x 24″ D
Electricial:200-240 VAC, 50/60 Hz, 20A/30A
Superior, Comfortable Laser Hair Removal
Laser Hair Removal An In-demand Procedure
Global hair removal procedures are growing at a rapid pace. Laser hair removal has been among the top non-surgical procedures according to the American Society of Aesthetic Plastic Surgery and procedure revenue is anticipated to go to $1.35B by 20221. The industry often refers to laser hair removal as a gateway procedure as it offers an entry point into the aesthetic market for patients and practitioners alike.excel HR combines a high-power 755 nm Alexandrite laser and Cuteras proven long-pulse 1064 nm Nd:YAG laser for safe, effective high-volume hair removal on all skin types. The combination of wavelengths not only allows for effective hair removal, but is also a solution for epidermal pigmented lesions, vascular lesions and Cuteras signature laser genesis skin revitalization procedure.excel HR Technology
Proven Wavelengths
excel HR combines the gold standard laser wavelengths for hair removal. The 755 nm Alexandrite laser is highly absorbed by melanin making it an ideal solution for finer hair on skin types I-III. Because of the high melanin absorption characteristics, it has also been proven to provide long-term results on epidermal pigmented lesions.The 1064 nm Nd:YAG is the safest wavelength for permanent hair reduction on darker skin types and tanned skin. By selecting the appropriate spot size, this laser can also be used for treating facial and leg veins and perform laser genesis procedure.truPulse Delivery with Index Matching
Unique to Cutera, the truPulse technology delivers constant, sustained energy throughout the pulse duration to ensure consistent performance and proven clinical outcomes for your patients.excel HRs index matching delivery results in more efficient coupling of laser energy to target structures. Index matching allows backscattered light to escape, further protecting the epidermis from heat build-up while maintaining treatment efficacy.Superior Contact Cooling
excel HR utilizes sapphire contact cooling to provide continuous cooling, maximizing your patients comfort and treatment safety.2 In a patient preference study that measured comfort and satisfaction for laser hair removal, 100% of the patients preferred excel HR over a comparable, competitive laser hair removal procedure.321st Century Laser Hair Removal System
Developed by the innovative leader in aesthetic laser technology, excel HR laser hair removal system provides advanced premium hair removal solutions for every skin type. Combining a new high-power 755 nm Alexandrite laser, and CUTERAs proven long-pulse 1064 nm Nd:YAG laser, coupled with the superiority of sapphire contact cooling, excel HR redefines modern laser hair removal.This makes excel HR laser system an effective, safe and comfortable option for laser hair removal for the 21st century.Applications Cutera Excel HR 1064 755 Hair Removal System
– Hair removal
– Benign pigmented lesion removal
– Veins, facial
– Veins, leg
– Laser Genesis | Nidek OPD-Scan II ARK 10000 Autorefractor KeratometerThe OPD SCAN II is the only instrument that easily combines Wavefront, Topography and Refraction all into one unit that sits on a table top! This allows the isolation of any optical problem to cornea or crystalline lens making it easy to decide if lensectomy or corneal surgery is the procedure of choice. It is also very mobile if need be!The NIDEK OPD-Scan II provides information on corneal topography, wavefront, autorefraction, keratometry and pupillometry in one unit, utilizing state-of-the-art imaging and analysis technology developed specifically to measure normal to highly aberrated eyes. The system offers a variety of data maps to provide information on the total refractive error, wavefront, corneal shape, internal aberrations and visual quality of the eye, allowing highly accurate and reliable information for optic diagnostics.Our units are carefully refurbished, inspected and serviced by our trained technician prior to shipment. We also offer service on almost all Nidek equipment! ARK-10000 measures the refractive condition and analyzes corneal shape of the patient’s eye. The refractive condition is measured by weak infrared rays, and corneal shape is analyzedbased on projected placido rings onto the cornea. FinancingWe offer easy and flexible financing options on new and used ophthalmic equipment, including, Bausch & Lomb, Visx, Zeiss Humphrey, Topcon, Canon, Alcon and more! Maximize your budget and improve your bottom line with Laser Locators easy equipment financing plan. We have partnered with Stearns Bank to provide financing to our customers. Features Nidek OPD-Scan II ARK 10000 Autorefractor Keratometer
– OPD Map shows point by point aberration of patient’s eye in diopters
– Measurement Selection for Improved Reliability
– Fast Processing Speed
– Improved Accessibility to a Patient eye
– Wide Measurement Range
(Sphere -20.0 to +22.0D and Cylinder 0.0 to ±12.0D)
– Easy Data Maintenance with a Detachable HDD
– Network Capabilities
– Corneal NavigatorCorneal Navigator | Carestream Vita 25 Digital CR SystemCARESTREAM Vita Flex CR Systems are designed for small-to-midsize hospitals, clinics and practices that need compact digital solutions at an affordable price. With two options for throughput speed, Vita computed radiography systems offer in-house, high-quality digital imaging to fit your workflow. The flexible orientation makes it perfect for small spaces in offices or in mobile settings.System Beneits
Smaller size and weight
Multiple throughputs (30/45 PPH)
Ability to be positioned for horizontal or vertical feeds
Supports a number of cassette sizes
Uses Image Suite Software – easy-to-use platform
specially designed for the end userImage acquisition and management for CR and DR Systems
Image Suite V4 Software has set a new benchmark for workflow efficiency in smaller facilities. This robust software features an easy-to-use, touch-friendly interface, an enhanced set of tools, streamlined workflow and improved image quality. Our advanced “mini-PACS” module allows superb image management and analysis, and is now fully optional. Get the high-quality images you need with a system that’s a perfect fit – at very affordable price. Physical Specifications Carestream Vita 25 Digital CR System • Weight: 25 kg (55 lb) • Dimensions (W x D x H): 68.0 x 34.0 x 45.0 cm (26.7 x 13.4 x 17.7 in.) Power • Electrical Rating: 100-240 V AC 50/60 Hz • Maximum Power Consumption: 120 W • Power Consumption in Standby Mode: 42 W • Power Supply Conditions: AC Power 100~240 V AC,50/60 Hz, 1.5 A Kodak/Carestream Vita25 CR System:25 Plate Per Hour Reader
2, 14×17 Cassettes
PC, Keyboard, Monitor, & Mouse
Genesis Software
2 Year Warranty
Available with the following upgrades:PACS: 250GB & 2 Viewers
PACS: 450GB & 4 Viewers
Go from 25 to 45 Plates Per Hour
Additional 14×17 Cassettes
Additional 10×12 Cassettes | Nidek OPD-Scan III Corneal AnalyzerComprehensive vision analysis
OPD-Scan III VS is a device that mainly measures corneal shape (topographer) and refractive error (refractometer).
It clarifies causes of vision difficulties through wavefront analysis of information measured over a wide area.
Solutions for face-to-face consultingTablet viewer provides four kinds of easy-to-understand reports for explanation and consulting.
*The tablet is not included or sold with the OPD-Scan III VS.
Basic information reportBasic information to generally judge the patient’s eye conditions.
Topography reportIntuitive maps and numerical data for comprehending the corneal surface.
Simulation reportVisual performance simulations and MTF graphs for a variety of conditions.
Eye diagram image reportEye model to visually understand eye conditions ranging from eye fundus to cornea.
Wide range of display patterns
  Placido image
  Axial map (Additional indication)
  Visual Acuity map (Image charts)
Features Nidek OPD-Scan III Corneal Analyzer- Five-in-One true refractive workstation for all practitioners
- Overview summary for optimal clinical decisions
- A number of summaries
- Wider measurement area
- Greater topography resolution, blue placido rings
The OPD-Scan lll is the Five-in-One true refractive workstation combining - Wavefront Aberrometer
- Topographer
- Auto Refractometer
- Auto Keratometer
- Pupillometer and Pupillographer
- Irregularity helps determine the best strategy for vision correction. Separation into Total, Corneal and Internal components allows determination of the source of the optical pathology.
- PSF images of OPD, Axial, and Internal OPD map simulate objective retinal visual quality from each component of the eye for easy clinical assessment and patient education.
- Corneal Spherical Aberration aids in the selection of aspheric IOLs and contact lenses.
- Color coded Classification Indices help identify post-LASIK corneas and Keratoconus.
- The Astigmatism index aids the implantation of toric IOLs such as incision placement and lens alignment.
- A retroillumination image of cataracts captured during the OPD exam allows better understanding of pupillary effects on vision and in patient education.
|
Reviews
There are no reviews yet.