PERKASA MEDICAL

Free shipping worldwide. Orders over $200
Availability: In Stock

Tomey RC-5000 Auto Refractor Keratometer For Sale

$4,800.00

The Tomey RC-5000 has highly accurate measurement combined with short examination time and ease of use, makes working with the Tomey RC-5000 Autorefractor Keratometer both professional and quick. The advanced touch-screen display allows you to perform both refraction and keratometry automatically with one simple movement, capture one eye on the display and the Tomey RC-5000 will do both eyes automatically. With the new features, the Tomey RC-5000 Autorefractor Keratometer will surely make your office more efficient.

Other people want this. 15 people have this in their carts right now.

Description

Tomey RC-5000 Auto Refractor Keratometer

Tomey RC-5000 Refractometry

Normal Mode:

-Fogging is applied automatically for each measurement for more Accurate Results

Quick Mode:

-Fogging is applied as needed for consecutive measurements.

IOL/CAT Mode:

-This mode is used to measure cataract or pseudophakic eyes.

Keratometry:

-Short consecutive measurements and time provide reliable data.
-Measurements at 6.00mm (R=8.0mm) as well as at 3.00mm give you enough information for contact lens fitting.
-base curves of contact lenses are stored, categorized and suggested manufacturers are automatically printed.

Diameter Measurements of Cornea and Pupil:

-Measurement can be done easily by moving the two cursors on the display to the boundary of cornea or pupil. This is useful for deciding the diameter of a contact lens and for other contact lens fitting practice.

Power Joystick:

-Move the joystick ring up/down and the instrument head moves up/down quickly.
-Move the joystick hand rest to the right/left or backward/forward and the instrument head moves to the right/left or backward/forward quickly.
-Rotate the joystick ring and the instrument head moves up/down slowly.
-Tilt the joystick and the instrument head moves in each direction slowly.

Power Chinrest:

-The chin rest can be moved by pushing the buttons on the front panel. No need to reach out to the chin rest for manual adjustments.

Autorefractor Keratometer Features:

Refractometory : Tomey RC-5000 Auto Refractor Keratometer

-Sphere 25.00 to +22.00D (VD =12.00mm) Cylinder -10.00 to +10.00D (VD = 12.00mm)
-Axis 0 to 180 Degree
-Minimum Pupil Dia. 2.2mm
-Measurements Time 0.2 Sec.

Keratometry :

-Range 5.00mm to 11.00mm
-Corneal Refraction 30.68D to 67.50D (n = 1.3375)
-Corneal Astigmatism 0D to 10D (n = 1.3375)
-Axis 0 to 180 Degree
-Measured Area 3.0mm / 6.0 mm
-Measured Time 0.1 Sec PD
-Measurement Yes (50 to 86mm)
-Diameter Measuremnt of Cornea & Pupil 1.0 to 14.0mm
-Chinrest : Power Chin Rest
-Printer : High Speed Thermal Line Printer
-OutputPort RS-232C
-Power Requirements: AC 100V to 240V
-50/60Hz 130VA

Reviews

There are no reviews yet.

Be the first to review “Tomey RC-5000 Auto Refractor Keratometer For Sale”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsTomey RC-5000 Auto Refractor Keratometer For Sale removeTomey RC-800 Auto Refractor Keratometer For Sale removeHuvitz HRK-8000A Auto Refractor Keratometer For Sale removeZeiss Humphrey Hark 599 Autorefractor / Keratometer For Sale removeNidek OPD-Scan III Corneal Analyzer For Sale removeZeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD remove
NameTomey RC-5000 Auto Refractor Keratometer For Sale removeTomey RC-800 Auto Refractor Keratometer For Sale removeHuvitz HRK-8000A Auto Refractor Keratometer For Sale removeZeiss Humphrey Hark 599 Autorefractor / Keratometer For Sale removeNidek OPD-Scan III Corneal Analyzer For Sale removeZeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD remove
Image
SKU
Rating
Price $4,800.00 $3,700.00 $3,500.00 $2,500.00 $5,650.00 $4,500.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

DescriptionThe Tomey RC-5000 has highly accurate measurement combined with short examination time and ease of use, makes working with the Tomey RC-5000 Autorefractor Keratometer both professional and quick. The advanced touch-screen display allows you to perform both refraction and keratometry automatically with one simple movement, capture one eye on the display and the Tomey RC-5000 will do both eyes automatically. With the new features, the Tomey RC-5000 Autorefractor Keratometer will surely make your office more efficient.The Auto “Refkeratometer” RC-800 is the latest in economical, user-friendly, highly accurate auto “refkeratometry”. The RC-800 provides simple, easy measurement by the operator at an economical cost, without compromising accuracy or reliability.The image can then be displayed on a monitor, helping you to educate your patients The HRK can provide peripheral keratometry measurement data which is very useful when fitting contact lenses. The eye can be displayed in full colour mode on a tilting touch screen which enables you to see the patient’s contact lens fitting status, previously only possible using a slit lamp. As the HRK has the world’s first contact lens fitting function in an auto keratometer, you can now see the flourescein liquid with blue illumination along with automatic calculation and recommendation for contact lens fitting.

The HUMPHREY 599 is the best combination refractor-keratometer to offer subjective refinement of sphere, cylinder, and axis as well as isolated acuity lines, children’s targets, near testing, and low contrast sensitivity testing.

The OPD-Scan III is an automated 5 in 1 instrument that combines topography, wavefront, autorefraction, keratometry, and pupillometry — allowing accurate and reliable analysis of corneal aberration.The Cirrus HD-OCT is a non-contact, high resolution tomographic and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures, including cornea, retina, retinal nerve fiber layer, ganglion cell plus inner plexiform layer, macula, and optic nerve head. The Cirrus normative databases are quantitative tools for the comparison of retinal nerve fiber layer thickness, macular thickness, ganglion cell plus inner plexiform layer thickness, and optic nerve head measurements to a database of normal subjects. The Cirrus HD-OCT is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration, and glaucoma.
Content

Tomey RC-5000 Auto Refractor Keratometer

Tomey RC-5000 RefractometryNormal Mode:-Fogging is applied automatically for each measurement for more Accurate ResultsQuick Mode:-Fogging is applied as needed for consecutive measurements.IOL/CAT Mode:-This mode is used to measure cataract or pseudophakic eyes.Keratometry:-Short consecutive measurements and time provide reliable data. -Measurements at 6.00mm (R=8.0mm) as well as at 3.00mm give you enough information for contact lens fitting. -base curves of contact lenses are stored, categorized and suggested manufacturers are automatically printed.Diameter Measurements of Cornea and Pupil:-Measurement can be done easily by moving the two cursors on the display to the boundary of cornea or pupil. This is useful for deciding the diameter of a contact lens and for other contact lens fitting practice.Power Joystick:-Move the joystick ring up/down and the instrument head moves up/down quickly. -Move the joystick hand rest to the right/left or backward/forward and the instrument head moves to the right/left or backward/forward quickly. -Rotate the joystick ring and the instrument head moves up/down slowly. -Tilt the joystick and the instrument head moves in each direction slowly.Power Chinrest:-The chin rest can be moved by pushing the buttons on the front panel. No need to reach out to the chin rest for manual adjustments.Autorefractor Keratometer Features:Refractometory : Tomey RC-5000 Auto Refractor Keratometer-Sphere 25.00 to +22.00D (VD =12.00mm) Cylinder -10.00 to +10.00D (VD = 12.00mm) -Axis 0 to 180 Degree -Minimum Pupil Dia. 2.2mm -Measurements Time 0.2 Sec.Keratometry :-Range 5.00mm to 11.00mm -Corneal Refraction 30.68D to 67.50D (n = 1.3375) -Corneal Astigmatism 0D to 10D (n = 1.3375) -Axis 0 to 180 Degree -Measured Area 3.0mm / 6.0 mm -Measured Time 0.1 Sec PD -Measurement Yes (50 to 86mm) -Diameter Measuremnt of Cornea & Pupil 1.0 to 14.0mm -Chinrest : Power Chin Rest -Printer : High Speed Thermal Line Printer -OutputPort RS-232C -Power Requirements: AC 100V to 240V -50/60Hz 130VA

Tomey RC-800 Auto Refractor Keratometer

Refractometry: Simple handling of the fine adjustment and measurement by yourself. Fogging is applied automatically for each measurement for more accurate results.Keratometry: Short consecutive measurements and time provide reliable data. Measurements at φ3.0mm (R = 8.0mm) give you enough information for contact lens fitting.Diameter Measurement of Cornea and Pupil: Easy measurement by moving the two cursors on the display to the boundaries of Cornea or Pupil.Language Selection: RC-800 has a Multi-language function. You can select your required language from “English”, “Japanese”, “German”, “Chinese”, “Spanish”, “Spanish Latin America”, “Italian”, “Portuguese”, “French” and “Russian”.Features:• Highly Accurate • Simple to Use • Diameter Measurement of Cornea and Pupil • High Speed Printer • Auto Shot • Color Touch Screen • USB connection • Large Patient Database • Easy Database Operation • Multi-Language Operation • Fourier Refractive Analysis • Quick Data Reference • Built-in LCD Alignment • Keratoconus Screening & Other ApplicationsMeasurement Ranges:Refraction:• Sphere: -25.00D to +22.00D (VD=12.0mm) • Cylinder: 0D to ±10.00D (VD=12.0mm) • Axis: 0° to 180° • Minimum Pupil Dia: Ø2.0mm • Measurement time: 0.2 second/single eye (data taking time)Keratometry:• Range: 5.00mm to 11.00mm • Corneal Refraction: 30.68D to 67.50D (n=1.3375) • Corneal Astigmatism: 0D to 10D (n=1.3375) • Axis: 0° to 180° • Measurement area: Ø3mm (at 8.00mm corneal curvature) • Measurement time: 0.1 second/single eye (data taking time)Other features:Tomey RC-800 Auto Refractor Keratometer• PD Measurement range 50 to 86mm • Corneal diameter measurement • Measurement range: 10.0 to 14.0mm • Display unit: 0.1mm • Pupil diameter measurement • Measurement range: 1.0 to 10.0 mm • Display unit: 0.1mm • Built-in Printer Thermal printer • Data output type RS232C / USB-D • Display 5.7 inch color liquid crystal display • Dimensions and weight 297(W)x 500(D) x 448(H)mm • Approx. 17kg • Power Requirements AC 100V to 240V, 50 / 60 Hz, 80VA to 100VAThe Auto “Refkeratometer” RC-800 is the latest in economical, user-friendly, highly accurate auto “refkeratometry”. The RC-800 provides simple, easy measurement by the operator at an economical cost, without compromising accuracy or reliability.

Huvitz HRK-8000A Auto Refractor KeratometerHuvitz Auto Ref – Keratometer HRK-8000A
  • Touch and tilting 7″ LCD Screen that allows for free and smooth tilting for viewing at any angle.
  • Optimized Optical System
  • Micro Lens Array
  • Aberration Measurement which also can be displayed in a graphical Zernike Refraction Map
  • PSF & Image Simulation
  • Colour View Mode
  • Peripheral Keratometry Measurement
  • Ultra High Precision KER Data
  • Contact Lens Fitting Assistance Guide
  • Contact Lens Prescription Guide
  • Auto Tracking
  • Animated Guide
  • Faster Measurement Speed
  • Quiet and speedy auto cutting printer
  • More data on aberration measurement
With its extreme precision and accuracy, the HRK8000A uses the most advanced wavefront technology to measure the light reflected from the retina and helps you to diagnose any refractive error. With a micro lens array developed by Huvitz, the HRK creates a number of focal points, the pattern of which can give a valuable insight into the patients ocular system. The HRK not only displays the conventional data such as spherical, cylinder and axis, the high order aberration data is displayed in a graphical Zernike refractive map, giving you a deeper understanding of your patient’s eyes.Optimized Optical System Huvitz HRK-8000A Auto Refractor Keratometer A wavefront is a physical representation of the optical quality of a light beam. Using various methods, aberrometers map how light rays travel through the eye. The HR-8000A is engineered according to the Hartmann-Shack wavefront measurement technique, which is widely preferred for its speed and repeatability.Touch & Tilting Color Display Screen  A bright, high contrast 7″ VGA color TFT LCD screen provides high resolution video images. A smooth, free tilting function also offers you a comfortable and clear view at any angle.The image can then be displayed on a monitor, helping you to educate your patients The HRK can provide peripheral keratometry measurement data which is very useful when fitting contact lenses. The eye can be displayed in full colour mode on a tilting touch screen which enables you to see the patient’s contact lens fitting status, previously only possible using a slit lamp. As the HRK has the world’s first contact lens fitting function in an auto keratometer, you can now see the flourescein liquid with blue illumination along with automatic calculation and recommendation for contact lens fitting.

Zeiss Humphrey Hark 599 Autorefractor / Keratometer

The HUMPHREY 599 allows for immediate patient feedback on the prescription and can be linked to the Humphrey Lens Analyzer to allow patients to compare their current RX to the new refraction results. Precise keratometer readings can be instantly obtained for all clinical needs.Fast, accurate and objective measurements with complete printout Automatic cycle for objective measurements Complete automatic alignment and tracking Acuity line isolation Cylinder and axis refinement Duochrome target Jackson Cross Cylinder Test Near vision testing Glare testing Spherical equivalents PD displayed on printout Children’s acuity targets Recall for old and new Rx comparisons Communicom Interface Keratometry Reading including average and delta K’s 
  • Fast, accurate and objective measurements with complete printout
  • Automatic cycle for objective measurements
  • Complete automatic alignment and tracking
  • Acuity line isolation
  • Cylinder and axis refinement
  • Duochrome target
  • Jackson Cross Cylinder Test
  • Near vision testing
  • Spherical equivalents
  • PD displayed on printout
  • Children’s acuity targets
  • Recall for old and new Rx comparisons
  • Communicom Interface
  • Keratometry Reading including average and delta K’s
Features:Fast, accurate and objective measurements with complete printout Automatic cycle for objective measurements Complete automatic alignment and tracking Acuity line isolation Cylinder and axis refinement Duochrome target Jackson Cross Cylinder Test Near vision testing Glare testing Spherical equivalents PD displayed on printout Children’s acuity targets Recall for old and new Rx comparisons Communicom Interface Keratometry Reading including average and delta K’s in the Humphrey HARK 599About us:Zeiss Humphrey Hark 599 Autorefractor / Keratometer ALT Medical Device is your complete eye care equipment solution. Is comprehensive company offering only high end, quality equipment. As a company, ALT Medical Device combines outstanding business practices with an unparalleled approach to customer service. We have 100% customer satisfaction by delivering quality equipment and full customer service with every transaction.

Nidek OPD-Scan III Corneal Analyzer

Comprehensive vision analysis

OPD-Scan III VS is a device that mainly measures corneal shape (topographer) and refractive error (refractometer). It clarifies causes of vision difficulties through wavefront analysis of information measured over a wide area.


Solutions for face-to-face consulting

Tablet viewer provides four kinds of easy-to-understand reports for explanation and consulting. *The tablet is not included or sold with the OPD-Scan III VS.




Basic information report

Basic information to generally judge the patient’s eye conditions.




Topography report

Intuitive maps and numerical data for comprehending the corneal surface.



Simulation report

Visual performance simulations and MTF graphs for a variety of conditions.




Eye diagram image report

Eye model to visually understand eye conditions ranging from eye fundus to cornea.




Wide range of display patterns


Placido image


Axial map (Additional indication)


Visual Acuity map (Image charts)

Features Nidek OPD-Scan III Corneal Analyzer
  • Five-in-One true refractive workstation for all practitioners
  • Overview summary for optimal clinical decisions
  • A number of summaries
  • Wider measurement area
  • Greater topography resolution, blue placido rings
The OPD-Scan lll is the Five-in-One true refractive workstation combining
  • Wavefront Aberrometer
  • Topographer
  • Auto Refractometer
  • Auto Keratometer
  • Pupillometer and Pupillographer
  1. Irregularity helps determine the best strategy for vision correction. Separation into Total, Corneal and Internal components allows determination of the source of the optical pathology.
  2. PSF images of OPD, Axial, and Internal OPD map simulate objective retinal visual quality from each component of the eye for easy clinical assessment and patient education.
  3. Corneal Spherical Aberration aids in the selection of aspheric IOLs and contact lenses.
  4. Color coded Classification Indices help identify post-LASIK corneas and Keratoconus.
  5. The Astigmatism index aids the implantation of toric IOLs such as incision placement and lens alignment.
  6. A retroillumination image of cataracts captured during the OPD exam allows better understanding of pupillary effects on vision and in patient education.

Zeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD

Accessories
  •     The ZEISS Certified Factory Direct Cirrus 4000 HD-OCT also includes the full Accessory Kit
  •     External Fixation Light
  •     Test Eye
  •     Mini Keyboard
  •     Optical Mouse
  •     Dust Cover
  •     Metric 5A/250v Fuse
  •     14 Ft. CAT 5e Network Cable
  •     USB Cable
  •     IEC 320 to NEMA 12 inch Power Cable
  •     IEC 320 39in. Power Cable
  •     Install Disc including Roxio Basic
  •     Symbol Sheet
  •     OCT Primer Guide
  •     Quick Start Guide
HD-OCT Imaging
  • Methodology: Spectral Domain OCT
  • Optical Source: superluminescent diode (SLD), 840 nm
  • Optical Power: < 725 μW at the cornea
  • Scan Speed: 27,000 A-scans per second
  • A-Scan depth: 2.0 mm (in tissue), 1024 points
  • Axial resolution: 5 μm (in tissue)
  • Transverse resolution: 15 μm (in tissue)
Fundus Imaging
  • Methodology: Line scanning ophthalmoscope
  • Live Fundus Image: During alignment and during OCT scan
  • Optical Source: Superluminescent diode (SLD), 750 nm
  • Optical Power: < 1.5 mW at the cornea
  • Field of View: 36 degrees W x 30 degrees H
  • Frame rate: >20 Hz
  • Transverse resolution: 25 μm (in tissue)
Iris Imaging
  • Methodology: CCD Camera
  • Resolution: 1280 x 1024
  • Live iris image: During alignment
Electrical, Physical and Environmental
  • Weight: 38kg (83 lbs)
  • Dimensions: 65L x 44W x 53H (cm)
  • Fixation: Internal, external
  • Internal fixation focus adjustment: -20D to +20D (diopters)
  • Input devices: Keyboard, mouse
  • Electrical rating (115V) Single Phase, 100/120V~ systems:50-60Hz, 5A
  • Fuse rating (115V) T 5A 250V
  • Electrical rating (230V) Single Phase, 220/240V~ systems:50-60 Hz, 2.5A
  • Fuse rating (230V) Fuse rating: T 5A 250V
  • Convenience Receptacle output ratings 115V~, 0.5 A Max, 50-60 Hz
  • Temperature (transport and storage) -40º to +70º C
  • Relative humidity (transport and storage) 10% to 100%, including condensation
  • Atmospheric pressure (transport and storage): 500 hPa to 1060 hPa
  • Temperature (operation) +10º to +35º C
  • Relative humidity (operation) 30% to 75%, excluding condensation
  • Atmospheric Pressure (operation) 700 hPa to 1060 hPa
Computer Zeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD
  • • High performance multi-core processor
  • • Internal storage: > 80,000 scans
  • • CD-RW, DVD-ROM drive
  • • Integrated 15″ color flat panel display.
The Cirrus HD-OCT is a non-contact, high resolution tomographic and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures, including cornea, retina, retinal nerve fiber layer, ganglion cell plus inner plexiform layer, macula, and optic nerve head. The Cirrus normative databases are quantitative tools for the comparison of retinal nerve fiber layer thickness, macular thickness, ganglion cell plus inner plexiform layer thickness, and optic nerve head measurements to a database of normal subjects. The Cirrus HD-OCT is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration, and glaucoma.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: Tomey RC-5000 Auto Refractor Keratometer For Sale $4,800.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Shopping cart close