PERKASA MEDICAL

Free shipping worldwide. Orders over $200
Availability: In Stock

Tomey RC-5000 Auto Refractor Keratometer For Sale

$4,800.00

The Tomey RC-5000 has highly accurate measurement combined with short examination time and ease of use, makes working with the Tomey RC-5000 Autorefractor Keratometer both professional and quick. The advanced touch-screen display allows you to perform both refraction and keratometry automatically with one simple movement, capture one eye on the display and the Tomey RC-5000 will do both eyes automatically. With the new features, the Tomey RC-5000 Autorefractor Keratometer will surely make your office more efficient.

Other people want this. 15 people have this in their carts right now.

Description

Tomey RC-5000 Auto Refractor Keratometer

Tomey RC-5000 Refractometry

Normal Mode:

-Fogging is applied automatically for each measurement for more Accurate Results

Quick Mode:

-Fogging is applied as needed for consecutive measurements.

IOL/CAT Mode:

-This mode is used to measure cataract or pseudophakic eyes.

Keratometry:

-Short consecutive measurements and time provide reliable data.
-Measurements at 6.00mm (R=8.0mm) as well as at 3.00mm give you enough information for contact lens fitting.
-base curves of contact lenses are stored, categorized and suggested manufacturers are automatically printed.

Diameter Measurements of Cornea and Pupil:

-Measurement can be done easily by moving the two cursors on the display to the boundary of cornea or pupil. This is useful for deciding the diameter of a contact lens and for other contact lens fitting practice.

Power Joystick:

-Move the joystick ring up/down and the instrument head moves up/down quickly.
-Move the joystick hand rest to the right/left or backward/forward and the instrument head moves to the right/left or backward/forward quickly.
-Rotate the joystick ring and the instrument head moves up/down slowly.
-Tilt the joystick and the instrument head moves in each direction slowly.

Power Chinrest:

-The chin rest can be moved by pushing the buttons on the front panel. No need to reach out to the chin rest for manual adjustments.

Autorefractor Keratometer Features:

Refractometory : Tomey RC-5000 Auto Refractor Keratometer

-Sphere 25.00 to +22.00D (VD =12.00mm) Cylinder -10.00 to +10.00D (VD = 12.00mm)
-Axis 0 to 180 Degree
-Minimum Pupil Dia. 2.2mm
-Measurements Time 0.2 Sec.

Keratometry :

-Range 5.00mm to 11.00mm
-Corneal Refraction 30.68D to 67.50D (n = 1.3375)
-Corneal Astigmatism 0D to 10D (n = 1.3375)
-Axis 0 to 180 Degree
-Measured Area 3.0mm / 6.0 mm
-Measured Time 0.1 Sec PD
-Measurement Yes (50 to 86mm)
-Diameter Measuremnt of Cornea & Pupil 1.0 to 14.0mm
-Chinrest : Power Chin Rest
-Printer : High Speed Thermal Line Printer
-OutputPort RS-232C
-Power Requirements: AC 100V to 240V
-50/60Hz 130VA

Reviews

There are no reviews yet.

Be the first to review “Tomey RC-5000 Auto Refractor Keratometer For Sale”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsTomey RC-5000 Auto Refractor Keratometer For Sale removeTomey RC-800 Auto Refractor Keratometer For Sale removeNidek OPD-Scan II ARK 10000 Autorefractor Keratometer removeAcuson Sequoia 512 LCD Ultrasound Machine removeCarl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD removeRighton Retinomax 5 Auto Refractor For Sale remove
NameTomey RC-5000 Auto Refractor Keratometer For Sale removeTomey RC-800 Auto Refractor Keratometer For Sale removeNidek OPD-Scan II ARK 10000 Autorefractor Keratometer removeAcuson Sequoia 512 LCD Ultrasound Machine removeCarl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD removeRighton Retinomax 5 Auto Refractor For Sale remove
Image
SKU
Rating
Price $4,800.00 $3,700.00 $5,150.00 $8,430.00 $6,950.00 $4,850.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

DescriptionThe Tomey RC-5000 has highly accurate measurement combined with short examination time and ease of use, makes working with the Tomey RC-5000 Autorefractor Keratometer both professional and quick. The advanced touch-screen display allows you to perform both refraction and keratometry automatically with one simple movement, capture one eye on the display and the Tomey RC-5000 will do both eyes automatically. With the new features, the Tomey RC-5000 Autorefractor Keratometer will surely make your office more efficient.The Auto “Refkeratometer” RC-800 is the latest in economical, user-friendly, highly accurate auto “refkeratometry”. The RC-800 provides simple, easy measurement by the operator at an economical cost, without compromising accuracy or reliability.The NIDEK OPD-Scan II provides information on corneal topography, wavefront, autorefraction, keratometry and pupillometry in one unit, utilizing state-of-the-art imaging and analysis technology developed specifically to measure normal to highly aberrated eyes.  The system offers a variety of data maps to provide information on the total refractive error, wavefront, corneal shape, internal aberrations and visual quality of the eye, allowing highly accurate and reliable information for optic diagnostics.The Sequoia system’s advanced technologies are designed to make image acquisition easier, reduce exam time and increase overall efficiency. Along with many other included features, the Sequoia system offers Native, a patient specific imaging which adapts both phase and amplitude information of each unique patient’s properties which delivers a consistently better image across a broad range of patients.CIRRUS HD-OCT 5000 is configured with the highest resolution visualization capabilities and sophisticated clinical applications such as Advanced RPE analysis to track retinal pigment epithelial integrity and Ganglion Cell Analysis to assess glaucomatous loss in the macula that may not be evident in the peripapillary region. The new FastTrac  retinal tracking reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning. This feature enables the highest resolution B-Scans to be captured in identical locations from visit to visit providing precise assessment of change in targeted pathologies.

RIGHTON RETINOMAX-5 AUTO REFRACTOMETER / KERATOMETER

  Automatic AxisCompensation and extended measurement range Not only does the device let examiner know the cylinder axis angle, but it can also be automatically adjusted if it is not level.
Content

Tomey RC-5000 Auto Refractor Keratometer

Tomey RC-5000 RefractometryNormal Mode:-Fogging is applied automatically for each measurement for more Accurate ResultsQuick Mode:-Fogging is applied as needed for consecutive measurements.IOL/CAT Mode:-This mode is used to measure cataract or pseudophakic eyes.Keratometry:-Short consecutive measurements and time provide reliable data. -Measurements at 6.00mm (R=8.0mm) as well as at 3.00mm give you enough information for contact lens fitting. -base curves of contact lenses are stored, categorized and suggested manufacturers are automatically printed.Diameter Measurements of Cornea and Pupil:-Measurement can be done easily by moving the two cursors on the display to the boundary of cornea or pupil. This is useful for deciding the diameter of a contact lens and for other contact lens fitting practice.Power Joystick:-Move the joystick ring up/down and the instrument head moves up/down quickly. -Move the joystick hand rest to the right/left or backward/forward and the instrument head moves to the right/left or backward/forward quickly. -Rotate the joystick ring and the instrument head moves up/down slowly. -Tilt the joystick and the instrument head moves in each direction slowly.Power Chinrest:-The chin rest can be moved by pushing the buttons on the front panel. No need to reach out to the chin rest for manual adjustments.Autorefractor Keratometer Features:Refractometory : Tomey RC-5000 Auto Refractor Keratometer-Sphere 25.00 to +22.00D (VD =12.00mm) Cylinder -10.00 to +10.00D (VD = 12.00mm) -Axis 0 to 180 Degree -Minimum Pupil Dia. 2.2mm -Measurements Time 0.2 Sec.Keratometry :-Range 5.00mm to 11.00mm -Corneal Refraction 30.68D to 67.50D (n = 1.3375) -Corneal Astigmatism 0D to 10D (n = 1.3375) -Axis 0 to 180 Degree -Measured Area 3.0mm / 6.0 mm -Measured Time 0.1 Sec PD -Measurement Yes (50 to 86mm) -Diameter Measuremnt of Cornea & Pupil 1.0 to 14.0mm -Chinrest : Power Chin Rest -Printer : High Speed Thermal Line Printer -OutputPort RS-232C -Power Requirements: AC 100V to 240V -50/60Hz 130VA

Tomey RC-800 Auto Refractor Keratometer

Refractometry: Simple handling of the fine adjustment and measurement by yourself. Fogging is applied automatically for each measurement for more accurate results.Keratometry: Short consecutive measurements and time provide reliable data. Measurements at φ3.0mm (R = 8.0mm) give you enough information for contact lens fitting.Diameter Measurement of Cornea and Pupil: Easy measurement by moving the two cursors on the display to the boundaries of Cornea or Pupil.Language Selection: RC-800 has a Multi-language function. You can select your required language from “English”, “Japanese”, “German”, “Chinese”, “Spanish”, “Spanish Latin America”, “Italian”, “Portuguese”, “French” and “Russian”.Features:• Highly Accurate • Simple to Use • Diameter Measurement of Cornea and Pupil • High Speed Printer • Auto Shot • Color Touch Screen • USB connection • Large Patient Database • Easy Database Operation • Multi-Language Operation • Fourier Refractive Analysis • Quick Data Reference • Built-in LCD Alignment • Keratoconus Screening & Other ApplicationsMeasurement Ranges:Refraction:• Sphere: -25.00D to +22.00D (VD=12.0mm) • Cylinder: 0D to ±10.00D (VD=12.0mm) • Axis: 0° to 180° • Minimum Pupil Dia: Ø2.0mm • Measurement time: 0.2 second/single eye (data taking time)Keratometry:• Range: 5.00mm to 11.00mm • Corneal Refraction: 30.68D to 67.50D (n=1.3375) • Corneal Astigmatism: 0D to 10D (n=1.3375) • Axis: 0° to 180° • Measurement area: Ø3mm (at 8.00mm corneal curvature) • Measurement time: 0.1 second/single eye (data taking time)Other features:Tomey RC-800 Auto Refractor Keratometer• PD Measurement range 50 to 86mm • Corneal diameter measurement • Measurement range: 10.0 to 14.0mm • Display unit: 0.1mm • Pupil diameter measurement • Measurement range: 1.0 to 10.0 mm • Display unit: 0.1mm • Built-in Printer Thermal printer • Data output type RS232C / USB-D • Display 5.7 inch color liquid crystal display • Dimensions and weight 297(W)x 500(D) x 448(H)mm • Approx. 17kg • Power Requirements AC 100V to 240V, 50 / 60 Hz, 80VA to 100VAThe Auto “Refkeratometer” RC-800 is the latest in economical, user-friendly, highly accurate auto “refkeratometry”. The RC-800 provides simple, easy measurement by the operator at an economical cost, without compromising accuracy or reliability.

Nidek OPD-Scan II ARK 10000 Autorefractor KeratometerThe OPD SCAN II is the only instrument that easily combines Wavefront, Topography and Refraction all into one unit that sits on a table top! This allows the isolation of any optical problem to cornea or crystalline lens making it easy to decide if lensectomy or corneal surgery is the procedure of choice. It is also very mobile if need be!
The NIDEK OPD-Scan II provides information on corneal topography, wavefront, autorefraction, keratometry and pupillometry in one unit, utilizing state-of-the-art imaging and analysis technology developed specifically to measure normal to highly aberrated eyes. The system offers a variety of data maps to provide information on the total refractive error, wavefront, corneal shape, internal aberrations and visual quality of the eye, allowing highly accurate and reliable information for optic diagnostics.Our units are carefully refurbished, inspected and serviced by our trained technician prior to shipment.  We also offer service on almost all Nidek equipment!ARK-10000 measures the refractive condition and analyzes corneal shape of the patient’s eye.  The refractive condition is measured by weak infrared rays, and corneal shape is analyzedbased on projected placido rings onto the cornea.FinancingWe offer easy and flexible financing options on new and used ophthalmic equipment, including, Bausch & Lomb, Visx, Zeiss Humphrey, Topcon, Canon, Alcon and more! Maximize your budget and improve your bottom line with Laser Locators easy equipment financing plan. We have partnered with Stearns Bank to provide financing to our customers.Features Nidek OPD-Scan II ARK 10000 Autorefractor Keratometer – OPD Map shows point by point aberration of patient’s eye in diopters – Measurement Selection for Improved Reliability – Fast Processing Speed – Improved Accessibility to a Patient eye – Wide Measurement Range (Sphere -20.0 to +22.0D and Cylinder 0.0 to ±12.0D) – Easy Data Maintenance with a Detachable HDD – Network Capabilities – Corneal NavigatorCorneal Navigator
Siemens Acuson Sequoia 512 LCD Ultrasound Machine18″ Flat panel LCD Monitor–Progressive Media & Display II Package, Cardiac/OB/Vascular Calc. Package, Signature II Option, AUX, CPS Cardiology, CPS General Cadene Trigg Burst, Calc Data to MO, Card Cadence II Contrast Quant, Cornoary Flow reserve, Dicome Store/Print, DTI (Doppler Tissue Imaging), High HR ECG, MIS/MIF, Modality Worklist Native TEQ, Native TEQ, NTHI (Native Tissue Harmonics), Spectral TEQ, TEQ (Tissue Equalization), VVI

Features

  • Shared Service
  • Native Patient Specific Imaging
  • Four Sight TEE view
  • Axius quantitative strain rate imaging
  • Cadence contrast pulse sequencing technology
  • Native Tissue Harmonic Imaging
  • Native TEQ ultrasound technology
  • Color doppler, Color angio and b-color
  • PW/CW Doppler
  • M-Mode
  • Folding Flat Panel Display
  • DICOM capabilities

Applications

  • Abdominal
  • Breast
  • OB/GYN
  • Vascular
  • Pediatrics
  • Cardiology
  • Musculoskeletal
  • Neonatal

Acuson Sequoia 512 Features:

  • Imaging: Gray-scale 2-D, M-mode, SST Color Doppler, Solo Spectral Doppler, 3-D Surface Rendering, Native Tissue Harmonic Imaging, Auto Doppler, M-Mode, PW Doppler, Color Doppler, Color Power Doppler
  • 19" color CRT monitor
  • Native tissue harmonic imaging (NTHI)
  • DIMAQ: image management
  • Advanced vascular analysis
  • Advanced spatial compounding
  • Native patient specific imaging
  • Mitral valve assessment
  • CPS contrast pulse sequencing technology
  • Clarifying vascular enhancement technology
  • High resolution color flow
  • Vascular, and General Imaging calculation packages
  • Coherent beamformer technology/spatial compounding
  • Space/time resolution control
  • Cine and zoom/RES
Compatible Ultrasound Probes and Transducers:
  • Acuson V5Ms TEE Probe
  • Acuson 4C1 Curved Array Probe
  • Acuson 6C2 Curved Array Probe
  • Acuson 8C4 Curved Array Probe
  • Acuson 4V1 Vector Array Probe
  • Acuson EV-8C4 Endocavitary Probe
  • Acuson EC-10C5 Endocavitary Probe
  • Acuson 6L3 Linear Array Probe
  • Acuson 8L5T Intraoperative Probe
  • Acuson 8L5 Linear Array Probe
  • Acuson 9L4 Linear Array Probe
  • Acuson 15L8 Linear Array Probe
  • Acuson 17L5 Linear Array Probe
The Sequoia 512 with LCD ultrasound machine uniquely minimizes automatic image optimization time by up to 80% to make way for an easier and speedier ultrasound test time as well as allow for a more confident diagnosis each time. As a patient-specific imaging ultrasound, it has a unique matched response capacity for accurate image quality, sharp clinical specificity, and optimized diagnostic outcomes that makes infinitesimal pathologies and other anatomical detail in the most difficult-to-image patients becomes more vivid and visible. 
Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD

Advancing Smart OCT

for Anterior Segment, Glaucoma and Retina
  • Anterior Segment Premier Module
  • PanoMap Wide-Field Display
  • Smart HD Scans
  • En face report
Measurement centering with Foveafinder

Visualization at the speed of CIRRUS

Analyzing a single pathology from multiple views provides comprehensive insight and analysis of the clinical situation. How this helps you:
  • Spot small areas of pathology. Tightly spaced B-scans, (either 30 or 47 μm apart), in the cube ensure that small areas of pathology are imaged. For reference, a human hair is about 40-120 μm in diameter.
  • Visualize the fovea. Scans that are spaced further apart than in the CIRRUS cube may miss the central fovea.
  • Fuel for analysis. Millions of data points from the cube are fed into the Zeiss proprietary algorithms for accurate segmentation, reproducible measurements and registration for change analysis.
  • Take the pressure off the operator. As long as the scan is placed in the vicinity of the fovea or optic nerve, the software automatically centers the measurements after the capture.
  • See the tissue from different perspectives. View the cube data from all angles, with 3D rendering, OCT fundus images and Advanced Visualization™.
  • Future ready. Previously captured CIRRUS cubes can be analyzed using new analyses.
 
Measurement centering with Foveafinder

Tracking at the speed of CIRRUS

FastTrac™ reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning With FastTrac, scan at the highest resolution at the same location at each visit.
Watch video
Measurement centering with Foveafinder

Assessment at the speed of CIRRUS

Measurement centering with FoveaFinder and AutoCenter
On the macula, the unique FoveaFinder technology ensures the ETDRS and ganglion cell plus inner plexiform layer measurement frameworks are centered on the fovea.AutoCenter™ function automatically centers the 3.4 mm diameter peripapillary RNFL calculation circle around the disc for precise placement and repeatable registration. The placement of the circle is not operator dependent. Accuracy, registration and reproducibility are assured.
Measurement centering with Foveafinder

Manage at the speed of CIRRUS Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD

Guided Progression Analysis (GPA™) for Assessing RNFL and Optic Disc Change
GPA™ compares RNFL thickness and optic disc measurements over time and determines if statistically significant change has occurred.Focal Progression Analysis – Up to 6 progression maps are compared to two baselines. Areas of statistically significant change are color-coded yellow when first noted and then red when the change is sustained over consecutive visits. Trend Analysis with Rate of Change – RNFL thickness values are plotted over time. Trends are calculated and confidence intervals are shaded when rate of change is statistically significant.
 

Righton Retinomax 5 Auto Refractor

The Retinomax Series, the world’s leading handheld autorefractor and autorefractor/keratometer, delivers wide measurement range on par with table type refr, now boasts greater mobility, stability and accuracy. The Retinomax series is widely used as a global standard device for pediatric, screening, medical care in remote areas, disaster area and wide range of ophthalmic scene.FEATURES
  • View Finder – With view finder observation, no limit of operator age. Diopter adjustable range is +/-8D the same as Retinomax3. View finder arm angle is changeable of 0-135 degrees, making measurement easy regardless of patient’s position or posture. Adjustable diopter +/- 8D.
  • Wider Eye Piece – Eye piece relief is 48mm from 32.2mm so that enable to look inside image while even looking at outside. No need to stick eye to the eyepiece all the time.
  • Improved battery life – At 180 minutes, the battery capacity is now twice that of conventional models
  • Automatic Axis Compensation and Extended Measurement Range – Not only does the device let examiner know the cylinder axis angle, but it can also be automatically adjusted if it is not level
  • New Child Mode – While the measurement is being taken, a melody plays continually to keep children’s attention. A constantly changing color display, both on the outside and inside target the device, also keeps children involved during the process.
  • Light weight and easy-to-hold grip
View Finder Righton Retinomax 5 Auto RefractorWith view finder observation, no limit of operator age. Diopter adjustable rangeis +/-8D the same as Retinomax3. View finder arm angle is changeable of 0-135degrees, making measurement easy regardless of patient’s position or posture.Adjustable diopter +/- 8D.Improved battery lifeAt 180 minutes, the battery capacity is now twice that of conventional modelsWider Eye PieceEye piece relief is 48mm from 32.2mm so that enable to look inside image while even looking at outside. No need to stick eye to the eyepiece all the time.Focus AssistLets you know the exact focusing point with the following color-coding system.New Child ModeWhile the measurement is being taken, a melody plays continually to keep children’s attention. A constantly changing color display, both on the outside and inside of the device, also keeps children involved during the process.Automatic AxisCompensation and extended measurement range Not only does the device let examiner know the cylinder axis angle, but it can also be automatically adjusted if it is not level. 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: Tomey RC-5000 Auto Refractor Keratometer For Sale $4,800.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Shopping cart close