PERKASA MEDICAL

Free shipping worldwide. Orders over $200
Availability: In Stock

Righton Retinomax 5 Auto Refractor For Sale

$4,850.00

RIGHTON RETINOMAX-5 AUTO REFRACTOMETER / KERATOMETER

 

 

Automatic Axis

Compensation and extended measurement range
Not only does the device let examiner know the cylinder axis angle, but it can
also be automatically adjusted if it is not level.

Other people want this. 15 people have this in their carts right now.

Description

Righton Retinomax 5 Auto Refractor

The Retinomax Series, the world’s leading handheld autorefractor and autorefractor/keratometer, delivers wide measurement range on par with table type refr, now boasts greater mobility, stability and accuracy. The Retinomax series is widely used as a global standard device for pediatric, screening, medical care in remote areas, disaster area and wide range of ophthalmic scene.

FEATURES

  • View Finder – With view finder observation, no limit of operator age. Diopter adjustable range is +/-8D the same as Retinomax3. View finder arm angle is changeable of 0-135 degrees, making measurement easy regardless of patient’s position or posture. Adjustable diopter +/- 8D.
  • Wider Eye Piece – Eye piece relief is 48mm from 32.2mm so that enable to look inside image while even looking at outside. No need to stick eye to the eyepiece all the time.
  • Improved battery life – At 180 minutes, the battery capacity is now twice that of conventional models
  • Automatic Axis Compensation and Extended Measurement Range – Not only does the device let examiner know the cylinder axis angle, but it can also be automatically adjusted if it is not level
  • New Child Mode – While the measurement is being taken, a melody plays continually to keep children’s attention. A constantly changing color display, both on the outside and inside target the device, also keeps children involved during the process.
  • Light weight and easy-to-hold grip

View Finder Righton Retinomax 5 Auto Refractor

With view finder observation, no limit of operator age. Diopter adjustable rangeis +/-8D the same as Retinomax3. View finder arm angle is changeable of 0-135degrees, making measurement easy regardless of patient’s position or posture.Adjustable diopter +/- 8D.

Improved battery life

At 180 minutes, the battery capacity is now twice that of conventional models

Wider Eye Piece

Eye piece relief is 48mm from 32.2mm so that enable to
look inside image while even looking at outside. No need
to stick eye to the eyepiece all the time.

Focus Assist

Lets you know the exact focusing point with
the following color-coding system.

New Child Mode

While the measurement is being taken, a
melody plays continually to keep children’s
attention. A constantly changing color
display, both on the outside and inside of
the device, also keeps children involved
during the process.

Automatic Axis

Compensation and extended measurement range
Not only does the device let examiner know the cylinder axis angle, but it can
also be automatically adjusted if it is not level.

 

Reviews

There are no reviews yet.

Be the first to review “Righton Retinomax 5 Auto Refractor For Sale”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsRighton Retinomax 5 Auto Refractor For Sale removeTomey RC-5000 Auto Refractor Keratometer For Sale removeNidek CEM-530 Specular Microscope For Sale removeNidek OPD-Scan III Corneal Analyzer For Sale removeBison Dual ACCENTO Nd YAG Laser For Sale removeEzer ERK-9000 Ezer Autorefractor Keratometer remove
NameRighton Retinomax 5 Auto Refractor For Sale removeTomey RC-5000 Auto Refractor Keratometer For Sale removeNidek CEM-530 Specular Microscope For Sale removeNidek OPD-Scan III Corneal Analyzer For Sale removeBison Dual ACCENTO Nd YAG Laser For Sale removeEzer ERK-9000 Ezer Autorefractor Keratometer remove
Image
SKU
Rating
Price $4,850.00 $4,800.00 $3,250.00 $5,650.00 $9,800.00 $8,550.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description

RIGHTON RETINOMAX-5 AUTO REFRACTOMETER / KERATOMETER

  Automatic AxisCompensation and extended measurement range Not only does the device let examiner know the cylinder axis angle, but it can also be automatically adjusted if it is not level.
The Tomey RC-5000 has highly accurate measurement combined with short examination time and ease of use, makes working with the Tomey RC-5000 Autorefractor Keratometer both professional and quick. The advanced touch-screen display allows you to perform both refraction and keratometry automatically with one simple movement, capture one eye on the display and the Tomey RC-5000 will do both eyes automatically. With the new features, the Tomey RC-5000 Autorefractor Keratometer will surely make your office more efficient.

Combination of auto and manual analyses

All three manual analysis methods can be performed on the same image and also on auto-analyzed images. The versatility of combining automated and manual analyses allows analysis of the range of pathology in a comprehensive practice.
The CEM-530 with new advanced software and enhanced image capture system allows rapid image acquisition. 
The OPD-Scan III is an automated 5 in 1 instrument that combines topography, wavefront, autorefraction, keratometry, and pupillometry — allowing accurate and reliable analysis of corneal aberration.Bison Dual ACCENTO is the unique device combination with Alexandrite laser (755nm) and Nd:YAG laser (1064nm Long pulse) The combination of two different wavelengths makes DUAL ACCENTO a highly effective system for hair removal and pigmented lesions treatment. The 755nm penetrates deep into the skin and perfectly targets hair the follicle and absorbs melanin.Confidently measure the human eye with a sophisticated cutting edge technology designed to enhance your ability to diagnose ocular errors faster, easier, and accurately. Ezers ERK-7800 is brilliantly designed technology measures the eye with ultra precision and speed to provide reliable data as the starting point of your refraction and contact lens fitting. It’s compact and modern design enables seamless operation and an enhanced patient comfort, making it the ideal choice in for any ophthalmic practice. Backed by an industry leading 2-years warranty!
Content

Righton Retinomax 5 Auto Refractor

The Retinomax Series, the world’s leading handheld autorefractor and autorefractor/keratometer, delivers wide measurement range on par with table type refr, now boasts greater mobility, stability and accuracy. The Retinomax series is widely used as a global standard device for pediatric, screening, medical care in remote areas, disaster area and wide range of ophthalmic scene.FEATURES
  • View Finder – With view finder observation, no limit of operator age. Diopter adjustable range is +/-8D the same as Retinomax3. View finder arm angle is changeable of 0-135 degrees, making measurement easy regardless of patient’s position or posture. Adjustable diopter +/- 8D.
  • Wider Eye Piece – Eye piece relief is 48mm from 32.2mm so that enable to look inside image while even looking at outside. No need to stick eye to the eyepiece all the time.
  • Improved battery life – At 180 minutes, the battery capacity is now twice that of conventional models
  • Automatic Axis Compensation and Extended Measurement Range – Not only does the device let examiner know the cylinder axis angle, but it can also be automatically adjusted if it is not level
  • New Child Mode – While the measurement is being taken, a melody plays continually to keep children’s attention. A constantly changing color display, both on the outside and inside target the device, also keeps children involved during the process.
  • Light weight and easy-to-hold grip
View Finder Righton Retinomax 5 Auto RefractorWith view finder observation, no limit of operator age. Diopter adjustable rangeis +/-8D the same as Retinomax3. View finder arm angle is changeable of 0-135degrees, making measurement easy regardless of patient’s position or posture.Adjustable diopter +/- 8D.Improved battery lifeAt 180 minutes, the battery capacity is now twice that of conventional modelsWider Eye PieceEye piece relief is 48mm from 32.2mm so that enable to look inside image while even looking at outside. No need to stick eye to the eyepiece all the time.Focus AssistLets you know the exact focusing point with the following color-coding system.New Child ModeWhile the measurement is being taken, a melody plays continually to keep children’s attention. A constantly changing color display, both on the outside and inside of the device, also keeps children involved during the process.Automatic AxisCompensation and extended measurement range Not only does the device let examiner know the cylinder axis angle, but it can also be automatically adjusted if it is not level. 

Tomey RC-5000 Auto Refractor Keratometer

Tomey RC-5000 RefractometryNormal Mode:-Fogging is applied automatically for each measurement for more Accurate ResultsQuick Mode:-Fogging is applied as needed for consecutive measurements.IOL/CAT Mode:-This mode is used to measure cataract or pseudophakic eyes.Keratometry:-Short consecutive measurements and time provide reliable data. -Measurements at 6.00mm (R=8.0mm) as well as at 3.00mm give you enough information for contact lens fitting. -base curves of contact lenses are stored, categorized and suggested manufacturers are automatically printed.Diameter Measurements of Cornea and Pupil:-Measurement can be done easily by moving the two cursors on the display to the boundary of cornea or pupil. This is useful for deciding the diameter of a contact lens and for other contact lens fitting practice.Power Joystick:-Move the joystick ring up/down and the instrument head moves up/down quickly. -Move the joystick hand rest to the right/left or backward/forward and the instrument head moves to the right/left or backward/forward quickly. -Rotate the joystick ring and the instrument head moves up/down slowly. -Tilt the joystick and the instrument head moves in each direction slowly.Power Chinrest:-The chin rest can be moved by pushing the buttons on the front panel. No need to reach out to the chin rest for manual adjustments.Autorefractor Keratometer Features:Refractometory : Tomey RC-5000 Auto Refractor Keratometer-Sphere 25.00 to +22.00D (VD =12.00mm) Cylinder -10.00 to +10.00D (VD = 12.00mm) -Axis 0 to 180 Degree -Minimum Pupil Dia. 2.2mm -Measurements Time 0.2 Sec.Keratometry :-Range 5.00mm to 11.00mm -Corneal Refraction 30.68D to 67.50D (n = 1.3375) -Corneal Astigmatism 0D to 10D (n = 1.3375) -Axis 0 to 180 Degree -Measured Area 3.0mm / 6.0 mm -Measured Time 0.1 Sec PD -Measurement Yes (50 to 86mm) -Diameter Measuremnt of Cornea & Pupil 1.0 to 14.0mm -Chinrest : Power Chin Rest -Printer : High Speed Thermal Line Printer -OutputPort RS-232C -Power Requirements: AC 100V to 240V -50/60Hz 130VA

Nidek CEM-530 Specular Microscope

The analysis results with graphic and color-coded cell images helps the clinician to rapidly and effectively evaluate the endothelial cell layer.In addition to conventional central and peripheral specular microscopy, the CEM-530 includes a unique function to capture paracentral images.
  • Paracentral specular microscopy
  • Faster measurements and two-second auto analysis
  • Comprehensive analysis
  • Advanced manual analysis functions
  • Easy operation
  • Additional features with CEM Viewer for NAVIS-EX
Combination of auto and manual analyses
All three manual analysis methods can be performed on the same image and also on auto-analyzed images. The versatility of combining automated and manual analyses allows analysis of the range of pathology in a comprehensive practice.Features
  • Multi area specular microscopy
  • Enhanced usability and quick analysis
  • Advanced manual analysis functions
  • Combination of auto and manual analyses
  • Additional features with CEM Viewer for NAVIS-EX
Multi area specular microscopy
In addition to conventional central and peripheral specular microscopy, the CEM-530 includes a NIDEK original function that captures paracentral images. The combination of central, paracentral, and peripheral imaging provides a broader, overall view that can be used for detailed morphological and quantitative evaluation of the endothelial layer and individual cells.


Enhanced usability and quick analysis

The 3D auto tracking and auto shot functions result in a user friendly and patient friendly experience. Data analysis within 2 seconds allows efficient patient flow.

Detail analysis


Advanced manual analysis functions
Center point

Select the approximate center of a cell. The cells are detected based on the surrounding points. This method is effective for areas where groups of cells are clumped together.




Corner point

Trace the outlines of the cells to be analyzed by selecting the corners of each cell. This method is suitable for detailed identification of the size and dimension of isolated cells.




Pattern select

Select a hexagonal reference pattern that is similar to the cell size and drag it onto the cell to be analyzed. This method is effective for rough identification of the size and dimension of the cells.


 Combination of auto and manual analyses 
All three manual analysis methods can be performed on the same image and on auto-analyzed images. The versatility of combining automated and manual analysis on the same image allows for better clinical interpretation of the diverse range of pathology in a comprehensive practice.


Additional features with CEM Viewer for NAVIS-EX* (optional)
CEM Viewer is software used for viewing and working with CEM-530 data via NAVIS-EX. This function enhances the capability of the CEM-530 with additional features and increases the efficiency of any clinic. *NAVIS-EX is optional software and is required for use of the CEM Viewer.
Data management and endothelial cell count

Unlimited NAVIS-EX database is available for review on the CEM Viewer. The basic functions of the CEM-530 such as endothelial cell count are available on the CEM Viewer.




Progression follow-up and comparison

Multiple examination data sets are displayed in chronological order for follow-up. Additionally, two data sets are displayed for comparison. Endothelial changes can be monitored over time with this function.





Paracentral display with peripheral
The images and analyses of the paracentral and peripheral areas are displayed providing a comprehensive image of endothelial cells.

Nidek OPD-Scan III Corneal Analyzer

Comprehensive vision analysis

OPD-Scan III VS is a device that mainly measures corneal shape (topographer) and refractive error (refractometer). It clarifies causes of vision difficulties through wavefront analysis of information measured over a wide area.


Solutions for face-to-face consulting

Tablet viewer provides four kinds of easy-to-understand reports for explanation and consulting. *The tablet is not included or sold with the OPD-Scan III VS.




Basic information report

Basic information to generally judge the patient’s eye conditions.




Topography report

Intuitive maps and numerical data for comprehending the corneal surface.



Simulation report

Visual performance simulations and MTF graphs for a variety of conditions.




Eye diagram image report

Eye model to visually understand eye conditions ranging from eye fundus to cornea.




Wide range of display patterns


Placido image


Axial map (Additional indication)


Visual Acuity map (Image charts)

Features Nidek OPD-Scan III Corneal Analyzer
  • Five-in-One true refractive workstation for all practitioners
  • Overview summary for optimal clinical decisions
  • A number of summaries
  • Wider measurement area
  • Greater topography resolution, blue placido rings
The OPD-Scan lll is the Five-in-One true refractive workstation combining
  • Wavefront Aberrometer
  • Topographer
  • Auto Refractometer
  • Auto Keratometer
  • Pupillometer and Pupillographer
  1. Irregularity helps determine the best strategy for vision correction. Separation into Total, Corneal and Internal components allows determination of the source of the optical pathology.
  2. PSF images of OPD, Axial, and Internal OPD map simulate objective retinal visual quality from each component of the eye for easy clinical assessment and patient education.
  3. Corneal Spherical Aberration aids in the selection of aspheric IOLs and contact lenses.
  4. Color coded Classification Indices help identify post-LASIK corneas and Keratoconus.
  5. The Astigmatism index aids the implantation of toric IOLs such as incision placement and lens alignment.
  6. A retroillumination image of cataracts captured during the OPD exam allows better understanding of pupillary effects on vision and in patient education.

Bison Dual ACCENTO Nd YAG Laser

Bison Dual ACCENTOBison Dual ACCENTO is the unique device combination with Alexandrite laser (755nm) and Nd:YAG laser (1064nm Long pulse) The combination of two different wavelengths makes DUAL ACCENTO a highly effective system for hair removal and pigmented lesions treatment. The 755nm penetrates deep into the skin and perfectly targets hair the follicle and absorbs melanin.The Dual Accento combined laser system is indicated for the following: 755 nm Long Pulsed Alexandrite Laser Temporary hair reduction. Stable long-term or permanent reduction through targeting of melanin in hair follicles. Treatment of bening pigmented lesions. Treatment of Wrinkles.The photocoagulation of dermatological vascular lesions (such as port of wine stains, hemangiomas, telangiectasis) 1064nm Long pulsed Nd:YAG laser. The removal of un-wanted hair reduction, for stable long term or permanent hair reduction and for treatment of PFB to all skin types Fitzpatrick I-VI including tanned skin.Pigmented lesions to reduce lesion size and patients with lesions. Reduction of red pigmentation in hypertrophic and keloid scars where vascularity is integral part of scar, treatment of wrinkle. Permanent hair reduction is defined as the long term, stable reduction in the number of hairs re- growing when measured at 6,9, and 12 months after the completion of treatment regime.The Dual Accento performs with high efficacy of the pigmentation problems without damaging tissue structures adjacent to the pigment. The wavelength of 1064nm Nd: YAG long pulse rejuvenates the skin by stimulating the collagen layer of the dermis and effectively treats vascular lesions and is appropriate for all skin types when used for hair removal.Bison Dual ACCENTO 1064nm NdYAG Laser With 755nm Alexandrite Laser Bison Dual ACCENTO 1064nm NdYAG Laser with 755nm Alexandrite Laser is the unique device. Combining 755nm Long pulsed Alexandrite and 1064nm Long pulsed NdYAG Alexandrite 755nm long pulsed wavelength. Due to the high melanin absorption is effective for hair removal and pigmented lesions treatment. NdYAG 1064nm long pulsed wavelength rejuvenates skin by stimulating the dermis layer, effectively treating vascular lesions.
Ezer ERK-9000 Ezer Autorefractor KeratometerThe ERK-9000 offers your staff the opportunity to gather a wealth of precise information about the patient in one fast and easy test, making the remainder of your exam swift, simple and exact. In addition to the wealth of functions you’d expect from a top-of-the-line autorefractor/keratometer, the ERK-9000 features auto-shoot programming, an illumination mode, IOL mode and so much more. Features:– Auto Refractor/Keratometer – Auto-Shoot Programming – Simple and Convenient User Environment – IOL Mode – Illumination Mode – Easy Network Capability – Wide Dioptric Measurement Range – Accurate Iris and Pupil Measurement – Ergonomic Joystick – Motorized Chin Rest – High-Speed Printer with Auto Paper Cut – 2-Year WarrantyIncludes:Ezer ERK-9000 Ezer Autorefractor Keratometer– Power Supply Cable – Model Eye ( S-5.0D or 5.12D or 5.25D, VD=12mm, R–7.95 ) – 2 rolls Printing Paper( Thermal Paper, Size : 57 X 50 mm ) – Dust cover ( Vinyl Cover: Use for long-term storage to prevent dust pollution ) – Operation ManualThe ERK-9000 combines all of the necessary visual pre-testing functions in one smartly designed instrument. Operators can perform refractometry and keratometry alone or simultaneously. The ERK-9000 is also quick. In fact, not even the unwanted effects of patient accommodation will stand in your way thanks to the unit’s valuable built-in auto-fogging mechanism.Auto-Shoot Programming Users can program the ERK-9000 to shoot at their preferred mode. One click on the joystick button can take a single measurement, three continuous measurements or five continuous measurements.Simple and Convenient User Environment The ERK-9000 features a user-friendly dashboard view. Sharp images with easy-to-understand icons make this 7.0-inch color TFT color touch screen LCD interface enjoyable to work with. IOLMode Patients presenting with cataract or IOL won’t present a challenge with the ERK-7800. In fact, now you can gather a wealth of information about natural lens opacity as well as take measurements on patients who have intraocular lens implants.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: Righton Retinomax 5 Auto Refractor For Sale $4,850.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Shopping cart close