PERKASA MEDICAL

Free shipping worldwide. Orders over $200
Availability: In Stock

Righton Retinomax 5 Auto Refractor For Sale

$4,850.00

RIGHTON RETINOMAX-5 AUTO REFRACTOMETER / KERATOMETER

 

 

Automatic Axis

Compensation and extended measurement range
Not only does the device let examiner know the cylinder axis angle, but it can
also be automatically adjusted if it is not level.

Other people want this. 15 people have this in their carts right now.

Description

Righton Retinomax 5 Auto Refractor

The Retinomax Series, the world’s leading handheld autorefractor and autorefractor/keratometer, delivers wide measurement range on par with table type refr, now boasts greater mobility, stability and accuracy. The Retinomax series is widely used as a global standard device for pediatric, screening, medical care in remote areas, disaster area and wide range of ophthalmic scene.

FEATURES

  • View Finder – With view finder observation, no limit of operator age. Diopter adjustable range is +/-8D the same as Retinomax3. View finder arm angle is changeable of 0-135 degrees, making measurement easy regardless of patient’s position or posture. Adjustable diopter +/- 8D.
  • Wider Eye Piece – Eye piece relief is 48mm from 32.2mm so that enable to look inside image while even looking at outside. No need to stick eye to the eyepiece all the time.
  • Improved battery life – At 180 minutes, the battery capacity is now twice that of conventional models
  • Automatic Axis Compensation and Extended Measurement Range – Not only does the device let examiner know the cylinder axis angle, but it can also be automatically adjusted if it is not level
  • New Child Mode – While the measurement is being taken, a melody plays continually to keep children’s attention. A constantly changing color display, both on the outside and inside target the device, also keeps children involved during the process.
  • Light weight and easy-to-hold grip

View Finder Righton Retinomax 5 Auto Refractor

With view finder observation, no limit of operator age. Diopter adjustable rangeis +/-8D the same as Retinomax3. View finder arm angle is changeable of 0-135degrees, making measurement easy regardless of patient’s position or posture.Adjustable diopter +/- 8D.

Improved battery life

At 180 minutes, the battery capacity is now twice that of conventional models

Wider Eye Piece

Eye piece relief is 48mm from 32.2mm so that enable to
look inside image while even looking at outside. No need
to stick eye to the eyepiece all the time.

Focus Assist

Lets you know the exact focusing point with
the following color-coding system.

New Child Mode

While the measurement is being taken, a
melody plays continually to keep children’s
attention. A constantly changing color
display, both on the outside and inside of
the device, also keeps children involved
during the process.

Automatic Axis

Compensation and extended measurement range
Not only does the device let examiner know the cylinder axis angle, but it can
also be automatically adjusted if it is not level.

 

Reviews

There are no reviews yet.

Be the first to review “Righton Retinomax 5 Auto Refractor For Sale”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsRighton Retinomax 5 Auto Refractor For Sale removeHuvitz HRK-8000A Auto Refractor Keratometer For Sale removeZeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD removeEssilor Mr Blue 2.0 Lens Edgers and Tracer For Sale removeActive Optical Extra 818 IPL Skin Rejuvenation & Hair Removal removeRodenstock Alino Multifunction Refractometer remove
NameRighton Retinomax 5 Auto Refractor For Sale removeHuvitz HRK-8000A Auto Refractor Keratometer For Sale removeZeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD removeEssilor Mr Blue 2.0 Lens Edgers and Tracer For Sale removeActive Optical Extra 818 IPL Skin Rejuvenation & Hair Removal removeRodenstock Alino Multifunction Refractometer remove
Image
SKU
Rating
Price $4,850.00 $3,500.00 $4,500.00 $3,600.00 $6,800.00 $5,620.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description

RIGHTON RETINOMAX-5 AUTO REFRACTOMETER / KERATOMETER

  Automatic AxisCompensation and extended measurement range Not only does the device let examiner know the cylinder axis angle, but it can also be automatically adjusted if it is not level.
The image can then be displayed on a monitor, helping you to educate your patients The HRK can provide peripheral keratometry measurement data which is very useful when fitting contact lenses. The eye can be displayed in full colour mode on a tilting touch screen which enables you to see the patient’s contact lens fitting status, previously only possible using a slit lamp. As the HRK has the world’s first contact lens fitting function in an auto keratometer, you can now see the flourescein liquid with blue illumination along with automatic calculation and recommendation for contact lens fitting.The Cirrus HD-OCT is a non-contact, high resolution tomographic and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures, including cornea, retina, retinal nerve fiber layer, ganglion cell plus inner plexiform layer, macula, and optic nerve head. The Cirrus normative databases are quantitative tools for the comparison of retinal nerve fiber layer thickness, macular thickness, ganglion cell plus inner plexiform layer thickness, and optic nerve head measurements to a database of normal subjects. The Cirrus HD-OCT is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration, and glaucoma.Mr Blue 2.0 is on the cutting edge of innovation – serving as a genuine ECP partner since its launch. Now featuring a whole range of new functions and even greater flexibility, Mr Blue is the perfect solution for demanding workshop.The Extra – 818 is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features: * Contemporary touch screen control * Built-in Patch Test procedure for examining the optimal energy level * A stunning number of 450,000 flashes in both lamps. * The Large Handpiece has a Push Button in addition to the Foot Switch making work easier and faster for the therapist.

Experience 6 analyses in 1 device: refraction, keratometry, topography, tonometry, pachymetry and dry eye analysis.

Content

Righton Retinomax 5 Auto Refractor

The Retinomax Series, the world’s leading handheld autorefractor and autorefractor/keratometer, delivers wide measurement range on par with table type refr, now boasts greater mobility, stability and accuracy. The Retinomax series is widely used as a global standard device for pediatric, screening, medical care in remote areas, disaster area and wide range of ophthalmic scene.FEATURES
  • View Finder – With view finder observation, no limit of operator age. Diopter adjustable range is +/-8D the same as Retinomax3. View finder arm angle is changeable of 0-135 degrees, making measurement easy regardless of patient’s position or posture. Adjustable diopter +/- 8D.
  • Wider Eye Piece – Eye piece relief is 48mm from 32.2mm so that enable to look inside image while even looking at outside. No need to stick eye to the eyepiece all the time.
  • Improved battery life – At 180 minutes, the battery capacity is now twice that of conventional models
  • Automatic Axis Compensation and Extended Measurement Range – Not only does the device let examiner know the cylinder axis angle, but it can also be automatically adjusted if it is not level
  • New Child Mode – While the measurement is being taken, a melody plays continually to keep children’s attention. A constantly changing color display, both on the outside and inside target the device, also keeps children involved during the process.
  • Light weight and easy-to-hold grip
View Finder Righton Retinomax 5 Auto RefractorWith view finder observation, no limit of operator age. Diopter adjustable rangeis +/-8D the same as Retinomax3. View finder arm angle is changeable of 0-135degrees, making measurement easy regardless of patient’s position or posture.Adjustable diopter +/- 8D.Improved battery lifeAt 180 minutes, the battery capacity is now twice that of conventional modelsWider Eye PieceEye piece relief is 48mm from 32.2mm so that enable to look inside image while even looking at outside. No need to stick eye to the eyepiece all the time.Focus AssistLets you know the exact focusing point with the following color-coding system.New Child ModeWhile the measurement is being taken, a melody plays continually to keep children’s attention. A constantly changing color display, both on the outside and inside of the device, also keeps children involved during the process.Automatic AxisCompensation and extended measurement range Not only does the device let examiner know the cylinder axis angle, but it can also be automatically adjusted if it is not level. 
Huvitz HRK-8000A Auto Refractor KeratometerHuvitz Auto Ref – Keratometer HRK-8000A
  • Touch and tilting 7″ LCD Screen that allows for free and smooth tilting for viewing at any angle.
  • Optimized Optical System
  • Micro Lens Array
  • Aberration Measurement which also can be displayed in a graphical Zernike Refraction Map
  • PSF & Image Simulation
  • Colour View Mode
  • Peripheral Keratometry Measurement
  • Ultra High Precision KER Data
  • Contact Lens Fitting Assistance Guide
  • Contact Lens Prescription Guide
  • Auto Tracking
  • Animated Guide
  • Faster Measurement Speed
  • Quiet and speedy auto cutting printer
  • More data on aberration measurement
With its extreme precision and accuracy, the HRK8000A uses the most advanced wavefront technology to measure the light reflected from the retina and helps you to diagnose any refractive error. With a micro lens array developed by Huvitz, the HRK creates a number of focal points, the pattern of which can give a valuable insight into the patients ocular system. The HRK not only displays the conventional data such as spherical, cylinder and axis, the high order aberration data is displayed in a graphical Zernike refractive map, giving you a deeper understanding of your patient’s eyes.Optimized Optical System Huvitz HRK-8000A Auto Refractor Keratometer A wavefront is a physical representation of the optical quality of a light beam. Using various methods, aberrometers map how light rays travel through the eye. The HR-8000A is engineered according to the Hartmann-Shack wavefront measurement technique, which is widely preferred for its speed and repeatability.Touch & Tilting Color Display Screen  A bright, high contrast 7″ VGA color TFT LCD screen provides high resolution video images. A smooth, free tilting function also offers you a comfortable and clear view at any angle.The image can then be displayed on a monitor, helping you to educate your patients The HRK can provide peripheral keratometry measurement data which is very useful when fitting contact lenses. The eye can be displayed in full colour mode on a tilting touch screen which enables you to see the patient’s contact lens fitting status, previously only possible using a slit lamp. As the HRK has the world’s first contact lens fitting function in an auto keratometer, you can now see the flourescein liquid with blue illumination along with automatic calculation and recommendation for contact lens fitting.

Zeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD

Accessories
  •     The ZEISS Certified Factory Direct Cirrus 4000 HD-OCT also includes the full Accessory Kit
  •     External Fixation Light
  •     Test Eye
  •     Mini Keyboard
  •     Optical Mouse
  •     Dust Cover
  •     Metric 5A/250v Fuse
  •     14 Ft. CAT 5e Network Cable
  •     USB Cable
  •     IEC 320 to NEMA 12 inch Power Cable
  •     IEC 320 39in. Power Cable
  •     Install Disc including Roxio Basic
  •     Symbol Sheet
  •     OCT Primer Guide
  •     Quick Start Guide
HD-OCT Imaging
  • Methodology: Spectral Domain OCT
  • Optical Source: superluminescent diode (SLD), 840 nm
  • Optical Power: < 725 μW at the cornea
  • Scan Speed: 27,000 A-scans per second
  • A-Scan depth: 2.0 mm (in tissue), 1024 points
  • Axial resolution: 5 μm (in tissue)
  • Transverse resolution: 15 μm (in tissue)
Fundus Imaging
  • Methodology: Line scanning ophthalmoscope
  • Live Fundus Image: During alignment and during OCT scan
  • Optical Source: Superluminescent diode (SLD), 750 nm
  • Optical Power: < 1.5 mW at the cornea
  • Field of View: 36 degrees W x 30 degrees H
  • Frame rate: >20 Hz
  • Transverse resolution: 25 μm (in tissue)
Iris Imaging
  • Methodology: CCD Camera
  • Resolution: 1280 x 1024
  • Live iris image: During alignment
Electrical, Physical and Environmental
  • Weight: 38kg (83 lbs)
  • Dimensions: 65L x 44W x 53H (cm)
  • Fixation: Internal, external
  • Internal fixation focus adjustment: -20D to +20D (diopters)
  • Input devices: Keyboard, mouse
  • Electrical rating (115V) Single Phase, 100/120V~ systems:50-60Hz, 5A
  • Fuse rating (115V) T 5A 250V
  • Electrical rating (230V) Single Phase, 220/240V~ systems:50-60 Hz, 2.5A
  • Fuse rating (230V) Fuse rating: T 5A 250V
  • Convenience Receptacle output ratings 115V~, 0.5 A Max, 50-60 Hz
  • Temperature (transport and storage) -40º to +70º C
  • Relative humidity (transport and storage) 10% to 100%, including condensation
  • Atmospheric pressure (transport and storage): 500 hPa to 1060 hPa
  • Temperature (operation) +10º to +35º C
  • Relative humidity (operation) 30% to 75%, excluding condensation
  • Atmospheric Pressure (operation) 700 hPa to 1060 hPa
Computer Zeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD
  • • High performance multi-core processor
  • • Internal storage: > 80,000 scans
  • • CD-RW, DVD-ROM drive
  • • Integrated 15″ color flat panel display.
The Cirrus HD-OCT is a non-contact, high resolution tomographic and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures, including cornea, retina, retinal nerve fiber layer, ganglion cell plus inner plexiform layer, macula, and optic nerve head. The Cirrus normative databases are quantitative tools for the comparison of retinal nerve fiber layer thickness, macular thickness, ganglion cell plus inner plexiform layer thickness, and optic nerve head measurements to a database of normal subjects. The Cirrus HD-OCT is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration, and glaucoma.
Essilor Mr Blue 2.0 Lens Edgers and TracerComplete Control of Lens Mounting
  • Optimal monitoring of all trajectories, irrespective of finishing materials or shapes
  • Absolute axis control thanks to hybrid edging technology: grinding + milling
  • Ideally suited for quality finishing even on highest base curves
  • Fast and accurate drilling with data acquired in a single operation
  • Automatic centering and blocking for simple operation
Unrivalled Ergonomics
  • Completely integrated functions without external peripheral devices
  • Vertical architecture with <Heads-up displays> for optimum comfort
  • Storage features ensure all accessories are within reach.
  • Intelligent interface adapts to the way you work.
Highest Quality Guaranteed Essilor Mr Blue 2.0 Lens Edgers and TracerPerfect Centering
  • Binocular 3-D tracing of full-rim frames up to base 9*
  • Automatic adjustment of centering data based on the frames’ 30D parameters*
Aesthetic and Robust Mountings
  • FIT-4-Frame technology with dedicated small wheel*
  • Drilling and grooving tools can be tilted up to 30o, making it safe to mount lenses of up to base 10. *Essilor patents and exclusives
Safe Process
  • Roughing cycle automatically adapts to the curves of lenses up to base 10, avoiding all risk of breakage
  • Bevel placement and shelf depth optimized for safe mounting without undue stress of lens
Aesthetically Pleasing and Easy-to-Mount Bevels
  • The bevel heights are adjustable to perfectly adjust to the thinnest grooves
  • The shelf bevel heights are optimized to follow the frame’s shape perfectly
  • The step bevel is particularly suited for sport eyeglasses with deep, rectangular or uneven groove profile
Mr Blue 2.0 is on the cutting edge of innovation – serving as a genuine ECP partner since its launch. Now featuring a whole range of new functions and even greater flexibility, Mr Blue is the perfect solution for demanding workshop.
Active Optical Extra 818 IPL Skin Rejuvenation & Hair RemovalHandpieces:Integrated dual handpieces Chilled Tip:Up to 4c Pulse Interval:0.5-2 Seconds Output Power:11-31 joulse/cm2, upto 4,000W Cooling System:Revolutionary dual cooling Control:Intuitive touch screen control Lamp’s Life Span:250,000 Flashes (Universal) 200,000 Flashes (Facial) Treatment Area:4.5 cm2 (15*50mm) Universal, 4.5 cm2 (15*30mm) Facial Wavelength:420-100 nm Weight:42Kg (including Stand) Dimensions:44cm x 45cm x 100cmExtra-818 Active Optical Extra 818 IPL Skin Rejuvenation & Hair Removal The Extra – 818 is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features: * Contemporary touch screen control * Built-in Patch Test procedure for examining the optimal energy level * A stunning number of 450,000 flashes in both lamps. * The Large Handpiece has a Push Button in addition to the Foot Switch making work easier and faster for the therapist.The Extra – 818, based on Active’s GEM-PL technology, sets sets a specific Pulse Pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.The combination of tested treatment protocols with high end engineering makes the Extra – 818 the perfect device for leading clinics.Revolutionary Cooling System The Extra – 818 has a dual cooling system, controlled and monitored in order to ensure long lifetime to the lamp and a comfortable treatment to the patient.Competitive cooling systems “freeze” the skin so that during the treatment the skin temperature will rise to a bearable level. However, this “freezing” temperature might limit the results because the follicles will not reach the coagulation temperature. To ensure optimal results Active installed a special Processor that prevents overcooling the skin and maintains a uniform low temperature of the “glass” throughout the treatment. This revolutionary system enables the Extra – 818 to provide best results with optimal patient comfort.Research Program For clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31Jcm2 with high intensity of 4,000W.

Rodenstock Alino Multifunction Refractometer

Tune-up your businessExperience 6 analyses in 1 device: Rodenstock Alino Multifunction Refractometer Are you ready for something that is all-in-one, timesaving, space-saving and suits your business perfectly?Have a look at how powerful ALINO can be.6 in 1 solution01 RefractionHaving a good starting value for subjective refraction is essential. The QUICK REF MODE supports this even for uncooperative patients.02 KeratometryKAI (Kerato-asymmetry index) & KRI (Kerato-regularity index) give the first hint of possible irregularities on the cornea. This supports evaluation of the best vision correction or best-fitting contact lens.03 TonometryThe very gentle air puff created by a new generation of air-flow technology means that patients more readily accept the need for regular check-ups of the IOP measurement.04 PachymetryCorrecting the IOP by measuring the central corneal thickness is essential in interpreting the intraocular pressure.05 TopographyVarious topographic maps support you in carrying out vision screenings, contact lens fittings and in patient education.06 Dry EyeObserve the customers’ eye health and evaluate the long-term tolerability of contact lenses.Take advantage of the combination of tests:Additional servicesTonometry + PachymetryContact lens fitting andtolerance controlKeratometry + Topography + Dry EyeEye healthcareTopography + Tonometry + Pachymetry + Dry EyeSpecifications Rodenstock Alino Multifunction Refractometer REFRACTIVE POWER MEASUREMENTSpherical refractive power (S)            -30.00 D to + 25.00 D (at VD = 12.0 mm)Cylindrical power (C)                          0.00 D to ± 12.50 D (at VD = 12.0 mm)Astigmatic axis (A)                              0° to 180°KERATOMETRY MEASUREMENTCorneal curvature radius                    5.00 mm to 13.00 mmCorneal astigmatic axis                      0° to 180°INTRAOCULAR PRESSURE MEASUREMENTMeasurement range                           1 mmHg to 60 mmHG (1 hPa to 80 hPa)PACHYMETRY MEASUREMENTMeasurement range                           300 μm to 800 μmTOPOGRAPHY MEASUREMENTCorneal curvature radius                    5.50 mm to 10.00 mmCorneal astigmatic axis                      0° to 180°AUXILIARY FUNCTIONInterpupillary distance                         Measurement range: 20 mm to 85 mmCorneal diameter and pupil diameter Measurement range: 1.00 mm to 14.00 mmDry eye observation                            Blinking Analysis, Tear Meniscus height, Hyperemia, Meibomian glandsDATA MANAGEMENTInternal Database                               Integrated SD CardPrinter                                                 Integrated thermal printerData Output Type                               3x USB 2.0, 1x LAN, 1x SD Card-slot, 1x WLANExport Format                                     CSV, XML, JPG, PDFDIMENSIONS & ELECTRIC REQUIREMENTSDimensions WDH                               312 × 491 × 450 mmWeight                                                 Approx. 23 kgVoltage                                                100 VAC to 240 VACFrequency                                           50/60 HzPower consumption                            110 VA
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: Righton Retinomax 5 Auto Refractor For Sale $4,850.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Shopping cart close