| Description | 2017 Lumenis M22 with ResurFX & IPL in Like-New Condition; Manufactured 10/22/2017; Based Unit Serial Number 11860, IPL Handpiece Serial Number: 4751; Nd Yag Serial Number: Perfect Cosmetic and Operating Condition, Single Owner; Handpieces Included & Total Pulse Counts: IPL Handpiece Total Pulse Count = 908; ResurFX Handpiece Pulse Count = 16 Pulses; Includes Expert Filters: 515nm, 560nm, 590nm, 615nm, 640nm, 695nm, and 755nm; Also Includes: Footswitch, Interlock, Operator Manual. | Includes:
1 Fractional Scanner Handpiece for Ablative Skin Resurfacing
1 Incisional Handpiece with up to or less than .2mm Spot Size
Handpiece Case
Distance Gauges
Footswitch
Patient Eyewear
Operator Eyewear
Operator Manual
Warning Sign | Includes:
Articulated Arm
2 Acuscan 120 Handpieces
125mm Incisional Handpiece
F-125 Attachments
Key | Laser Hair Removal
Details:- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| 2018 Lutronic Infini RF Microneedling Skin Tightening Laser with RF Microneedling Handpiece - with CONSUMABLE SUPPORT - Free Shipping - | Configuration:5 3b Line Generated Laser Diode Modules
Wavelength:635nm
Modulation:Constant Wave (CW) 1,000 Hz
Programming:5 time saving presets
Display:8″ Full color TFT Touch Screen Control Center
Power Source:100-240VAC 50-60Hz
Chassis:Power Coated metal frame for ease of cleaning
Housing:Thermoformed of Non-allergen material/plastic
Accessories:2 Keys, Laser Safety Glasses
Dimensions:49 x 32 x 57H”
Weight:266 lbs. |
| Content | 2017 Lumenis M22 IPL with ResurFX| Manufacturer Notes |
|---|
| M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal.Available Treatments with M22:– Acne Scar Treatment
– Hair Removal
– Non-Ablative Skin Resurfacing
– Photorejuvenation
– Pigmentation Treatment
– Scar Revision
– Vascular / Leg Vein Treatment
– Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge.Universal IPL
Optimal Pulse Technology (OPT)
Single handpiece with changeable filters and lightguides
For IPL skin treatments using photorejuvenationResurFX
The only True fractional non-ablative, with CoolScan scanner
No disposables
For skin resurfacingMulti-Spot Nd:YAG
The only one with Multiple Sequential Pulsing (MSP)
2 sized lightguides, changeable in seconds
For treatment of leg veins and vascular lesionsQ-Switched Nd:YAG
Homogenous beam profile for enhanced treatment safety and efficacy
For skin toning*, dark tattoos removal, and combination treatments
*Skin toning by treatment of pigmented lesions |
2017 Lumenis M22 IPL with ResurFX and Q-Switched Nd:YAG A modular multi-application system for hair removal and various skin conditions Details:M22 Serial Number: 21171 M22 Date of Manufacture: 2017-07-17 Total IPL Pulses: 19,186 Total ResurFX Pulses: 10,772 Q-Switched Nd:YAG Pulses: 385,505
Includes:IPL Handpiece Complete Standard IPL filters: 515, 560, 590, 615, 640, 695, 755nm, and Calibration Specialty IPL Filters: Acne and Vascular IPL Light Guides: (1)35 x 15 mm2; (1)15 x 8 mm2, (1) 6mm- round ResurFX Handpiece with SapphireCool Tip Q-Switched Nd:YAG Handpiece Foot Switch Power Cord 30 Days Parts and Labor Warranty
|
System specifications
Dimensions:[without ResurFX] 44 x 50.5 x 47 cm (17 x 20 x 18.5 inches)
Dimensions:[with ResurFX] 44 x 50.5 x 61.5 cm (17 X 20 X 24 inches)
Weight:[without ResurFX] 40 kg / 88 lbs
Weight:[with ResurFX] 55 kg / 121 lbs
Electrical requirements:100 240 VAC ±10%, 15A max., 50/60 Hz, single phase, dedicated line M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal. Available Treatments with M22:– Acne Scar Treatment
– Hair Removal
– Non-Ablative Skin Resurfacing
– Photorejuvenation
– Pigmentation Treatment
– Scar Revision
– Vascular / Leg Vein Treatment
– Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge. Universal IPL
Optimal Pulse Technology (OPT)
Single handpiece with changeable filters and lightguides
For IPL skin treatments using photorejuvenation ResurFX
The only True fractional non-ablative, with CoolScan scanner
No disposables
For skin resurfacing Multi-Spot Nd:YAG
The only one with Multiple Sequential Pulsing (MSP)
2 sized lightguides, changeable in seconds
For treatment of leg veins and vascular lesions | EMVERA CLARO2 CO2 LASER
Claro2 Medical Laser System
The Claro2 laser technology offers the most innovative approach to laser treatments today. It provides an acceptable and comfortable procedure under little or no anesthesia with minimum pain from evaporation of the skin layers, resulting in minimal social or work downtime. The laser delivers a series of microscopic, closely-spaced laser spots to the skin while simultaneously preserving the normal, healthy skin. The undamaged skin becomes a reservoir of tissue for fast heating and regeneration of the treated area by producing and providing new dermal collagen and eliminating epidermal pigmentation and irregularities to the skin tone. The Claro2 laser system is specially designed to improve skin texture and tone, and fight wrinkles, scars and pigmentations. Since the treatment procedures are customized to patients skin, operators are able to adjust laser settings to tailor treatments and achieve superior results.Claro2 Laser Features Provide:
Unparalleled char-free ablation, vaporization, excision, or incision of soft tissues
Reduced thermal damage to surrounding tissues
Rapid healing and minimal downtime
Stimulation of deeper collagen with high pulse energy
Large TFT LCD touch screen provides easy operation with the latest high speed microprocessor technology
Adjustable scanning patterns and sizes
Adjustable intensity of pilot beam
Adjustable pulse duration
Last treatment setting memorization
Automatic alarm system for operation and errors
No consumable costsIncludes:
1 Fractional Scanner Handpiece for Ablative Skin Resurfacing
1 Incisional Handpiece with up to or less than .2mm Spot Size
Handpiece Case
Distance Gauges
Footswitch
Patient Eyewear
Operator Eyewear
Operator Manual
Warning SignLaser Type:Sealed of Co2 Laser
Wavelength:10.6 um
Mode Structure:TEM00
Max Power:0-30W (adjustable)
Spot Size:Equal to or less than .2mm
Aiming Beam:630nm Red Laser (Adjustable Brightness)
Delivery System:Articulated Arm
Operation Modes:Continuous Wave, Single Pulse, Repetition Pulse, Super Pulse, Scanner
Pulse Width:Single Pulse (0.01-1s); Repetition Pulse (0.001-1s); Scanner (0.0001-0.01s)
Scan Size: Adjustable
Scan Pattern:Oval, Triangle, Rectangle, Line
Scan Array Density:Adjustable
Cooling System:Self-Contained, Closed Cycle
Power Supply:100-120V AC, 50/60Hz or 200-240V AC, 50/60Hz
Environment Temperature:10-40 Degrees Celsius
Relative Humidity:Below 80%
Dimensions:561mm x 500mm x 1443mm
Weight:42kgApplications Include:EMVERA CLARO2 CO2 LASERDermatology, Plastic Surgery and General Surgery procedures including but not limited to:
Laser skin resurfacing
Treatment of furrows and wrinkles
Removal of skin tags, actinic keratosis, acne scars, keloids, tattoos, telangiectasia, squamous and basel cell carcinoma, warts and uneven pigmentation
Treatment of cysts, abscesses, hemorrhoids and other soft tissue applications
Blepharoplasty
Site preparation for hair transplantsOtorhinolaryngology (ENT) procedures including but not limited to:
Treatment of leukoplakia of larynx, nasal obstruction, rhinophyma, verrucrea vulgares, choanal atresia, rhinophyma, LAUP and papillomatosis polypsGynecology:
Treatment of condyloma acuminate, cervical
intraepithelial neoplasia, leukoplakia and vulvar/
vaginal intraepithelial neoplasia, cervical dysplasia
Podiatry procedures including but not limited to:
Ablation, vaporization and excision of soft
tissue lesions such as ingrown nail, fungal nail,
porokcratoma, matrixectomy and verrucae vulgares | LUMENIS ACUPULSE 120 CO2 MACHINE
Includes:
Articulated Arm
2 Acuscan 120 Handpieces
125mm Incisional Handpiece
F-125 Attachments
KeySuperPulseTM TechnologyExceptional ablation/coagulation ratio.
Reach the desired treatment depth with a single pulse.
11 Built-in Treatment Modes.Maximum versatility with only two scanners.
Full parameter control for advanced users.
Short Pulse Duration.Enhanced patient comfort.
Lower chance of side effects.
Intuitive User Interface.Easy setup and quick treatments.
User presets for single-click treatments.11 Treatment Modes For Maximum Versatility
ACUSCAN120 FRACTIONAL SCANNERLUMENIS ACUPULSE 120 CO2 MACHINELaser Type:Co2
Wavelength:10,600 nm
AcuPulse
MultiModeTM SuperPulseTM CO2 Laser
AcuPulse is a complete ablative laser resurfacing workstation, featuring state of the art technology for all aesthetic resurfacing needs.
POWERFUL. VERSATILE. SIMPLE.Superficialfor moderate sun damage, fine lines, uneven texture, dyschromia, actinic keratosis and more.ComboDeep and Superficial combined together for sun damage, acne scars, wrinkles and more.Deepfor deeper lines and wrinkles, acne scars, uneven texture, dyschromia and more.StretchTouchfor skin furrows and textural irregularities.SURGITOUCH ADVANCED SCANNERFeatherTouchfor gental, single scan treatmentsToeTouchfor common foot ailments, such as plantar warts and ingrown toenailsSilkTouchfor more vigorous, double scan treatmentsPaintfor controlled, continous freehand placement on small areasFineTouchfor precise ablation of irregular pigmented lesions at various depths125MM INCISIONAL HANDPIECEBlephfor precise, clean incisions with minimal bleeding.Exceptional Ablation/Coagulation Ratio
When ablation depth is equal, more energy means more excess heat in the tissue. SuperPulse technology enables the deepest penetration with the lowest energy. This reduces patient discomfort, downtime and thermal damages.LUMENIS ACUPULSE 120 CO2 also enables shorter pulses, further enhancing patient safety. | 2019 Lumenis Splendor X- Laser Hair Removal
Lumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthThe Lumenis Splendor X has been introduced to be a player in the solid state Nd:YAG and Alexandrite laser hair removal market. The gold standard for hair removal has always been considered Alexandrite 755nm for light skins and Nd:YAG 1064nm for dark skins.The Lumenis Splendor X combines both in a unique way with blended emission.Instead of firing a single wavelength at a time the Splendor X allows you to fire both wavelengths simultaneous in adjustable amounts to suit the skin type and hair types. This means you are target multiple chromophores at any given time given enhanced results across the board.The Lumenis Splendor X also allows the user to choose between square and round spot sizes with large spot sizesLumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthLaser Hair Removal
Details:2019 Lumenis Splendor X- Laser Hair Removal- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| 2018 Lutronic Infini RF Microneedling Skin Tightening System Type: Bipolar RF (Radiofrequency) Frequency: 1 MHz Total RF Treatment Level: Up to Level 20 (Max. Power 50 W) Operation Mode:Microneedle Fractional RF (MFR) Treatment Duration:10 ms – 1,000 ms Tips: MFR Microneedle electrodes, 0.5 – 3.5 mm (Adjustable depth) SFR: Up to 144 pins Display: Color Touch LCD (Total Shot Count Displayed) Dual Switch: Foot & Finger Switch Weight: 28 kg Dimension: 362 mm (W) x 409 mm (L) x 1713 mm (H) Location: Lower Face Submental, Neck, Forehead, Periorbital Pass: Pass1: 2.25 – 3.5 mm, Pass2: 1.5 – 2.25 mm, Pass3: 1.0 – 1.25 mm Intensity: Low, Medium, High MANUFACTURER NOTES: Infini Radiofrequency Microneedling The LUTRONIC INFINI is the ideal solution to create targeted and robust coagulation zones in aging, sagging skin with pigmentation, wrinkles and laxity. Complete control over treatment depth and energy levels enables a multi-layered targeted approach for truly customized treatments, regardless of patients skin type or tanned skin. Now you can provide the best solution for results your patients demand year round. UNIQUE TECHNOLOGY, AMAZING RESULTS Infinis proven & impressive design delivers enhanced wrinkle reduction through 3-dimensional energy delivery to volumize tissue. RF energy delivered via insulated gold-coated microneedles creates precise and controllable fractionated coagulation zones within a specific layer of dermis. Adjustable depth control allows for customized and reproducible treatments of delicate areas. Infini effectively lowers the risk of PIH in dark skin types and can be safely used on patients with melasma and other types of pigmented lesions. Lutronics patented ComfortFlow technology maximizes comfort and patient satisfaction. INFINI is unique technology that puts you in control of your skin rejuvenation procedure. You control the treatment depth and energy levels to enable a multi-layered approach for customized treatments, regardless of skin type or tan. Now you can provide the best solution that will keep your patients returning and referring you to new patients.
IDEAL FOR:2018 Lutronic Infini RF Microneedling Skin Tightening– Acne Scars
– Skin tightening– Wrinkles and fine lines– Active inflammatory acne– Enlarged pores– Scar treatment– Stretch marks– Hyperhidrosis – Over production of sweat– Excessive sebum (face oil) production | ERCHONIA ZERONA Z5 LASER
The Erchonia Zerona Cosmetic Laser model is designed for use during non-invasive body contouring. It is a body sculpting machine designed to remove fat and contour the body without the invasive surgery that many patients prefer not to go under.Zerona is the only clinically-proven non-invasive body contouring treatment, providing 6 quick & painless treatments. These treatments specifically target stubborn fat areas and painlessly emulsify the fat under your skin using the Lymphatic system.ZERONA is the first non-invasive body slimming procedure to effectively remove excess fat!
Unlike other lipo and body slimming procedures, ZERONA allows patients to continue daily activities without interruptions from surgery, pain, wounds, bruises, or garments. The ZERONA protocol utilizes the Erchonia Laser Scanner, which is the safest and most researched low level laser in the world. ZERONA is also FDA approved for laser assisted liposuction. Find out how it worksVoluminous adipose tissue can appear when fatty material is present, and this, in turn, can bring about enlarged subcutaneous fat regions. Because subcutaneous fat is close to the skin’s surface, laser emulsification can have a dramatic effect on them. The collapse of adipose arrangements has been noted after laser therapy, reducing their volume and providing effective body slimming results. When the fat cells have reduced the body naturally excretes the fat over time giving the patient proven results after around six treatments over two weeks. This occurs during the bodys normal detoxification process.Configuration:5 3b Line Generated Laser Diode Modules
Wavelength:635nm
Modulation:Constant Wave (CW) 1,000 Hz
Programming:5 time saving presets
Display:8″ Full color TFT Touch Screen Control Center
Power Source:100-240VAC 50-60Hz
Chassis:Power Coated metal frame for ease of cleaning
Housing:Thermoformed of Non-allergen material/plastic
Accessories:2 Keys, Laser Safety Glasses
Dimensions:49 x 32 x 57H”
Weight:266 lbs.ERCHONIA ZERONA Z5Let’s take a closer lookERCHONIA ZERONA Z5 LASERFour separate histological studies were performed to assess the efficacy of laser in the emulsification (liquefaction) of fat. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were utilized to analyze adipose tissue. SEM and TEM images revealed the collapse of adipose arrangements subsequent to laser therapy. The voluminous state of an adipocyte cell is reduced due to the emulsification process. The fatty material is evacuated from the cell and moves into extracellular space. The voluminous nature of adipocytes due to the accumulation of fatty material is what gives rise to an enlarged subcutaneous fat region. ZERONA induces the formation of a transitory pore in the membrane of the fat cell. The pore enables the fatty material to seep out across the aperture and into extracellular space. The following images show the result of laser energy on a single fat cell and a group of fat cells.As you can see the ZERONA treatment liquifies the fat and the cell dumps it into the intercellular space. There are two types of fat cells – Subcutaneous and Visceral.Subcutaneous fat is located directly above the skeletal muscle and below the skin. Its superficial placement is what ensures proper depth penetration of the laser energy. Patients containing a high volume of visceral fat (fat below the skeletal muscle) are not ideal candidates for this procedure. However, they may still contain subcutaneous fat; therefore, you can treat the individual by just ensuring they adopt a healthy diet to address the visceral fat. |
Reviews
There are no reviews yet.