| Description | 2017 Lumenis M22 with ResurFX & IPL in Like-New Condition; Manufactured 10/22/2017; Based Unit Serial Number 11860, IPL Handpiece Serial Number: 4751; Nd Yag Serial Number: Perfect Cosmetic and Operating Condition, Single Owner; Handpieces Included & Total Pulse Counts: IPL Handpiece Total Pulse Count = 908; ResurFX Handpiece Pulse Count = 16 Pulses; Includes Expert Filters: 515nm, 560nm, 590nm, 615nm, 640nm, 695nm, and 755nm; Also Includes: Footswitch, Interlock, Operator Manual. | Advanced ergonomic handpiece with multi-spot, quick-zoom cartridges, and large touch screen GUI. | 2018 Edge for Life Hydrafacial MD Elite; Excellent Cosmetic and Operating Condition, about 85 Treatments Performed, Single Owner; Reason for Selling: No Longer Providing Service; Includes: Tower, Cartridge Handpiece, (1) Perk Treatment System for Localized Treatment of the Lips or Eyes, (2) Red LED Light Handpieces, (2) Blue LED Light Wireless Handpieces, (1) Lymphatic Drainage Treatment System, (3) Packs of Probe Tips, (1) Disposable Probes/Serum for the Perk attachment, (1) Pack Lymphatic Replacement Tubing, (1) Pack Clear Blue Cleaning Caps, (1) Pack Cleaning Brushes, Operator Manual. | Alma Inc announces the North American release of Opus, a new modern aesthetic platform featuring the company’s proprietary high-frequency unipolar radio-frequency technology, Opus Plasma.Reportedly the first-of-its-kind fractional plasma technology, Opus Plasma is engineered to address global or localized textural and skin quality concerns often corrected with conventional fractional resurfacing lasers in the past. | FOTONA Lightwalker ATS Dual Wavelength Dental Laser Laser – YAG | 2017 Lumenis Lightsheer Desire with 3 Handpieces – HS, XC and ET – Includes 805 and 1060 nm wavelengths – Like-New Condition; Serial Number: 3796, Date of Manufacture 2/15/2017, Excellent Cosmetic and Operating Condition – Like New with low pulses! RECENTLY INSPECTED April 2021, Included Handpieces & Pulse Counts: HS 22×35 mm Spot Size Diode Handpiece = 132 Pulses; XC 12×12 mm Spot Size Diode Handpiece = 3,362 Pulses; ET 9×9 mm Spot Size 1060 Handpiece = 6,590 Pulses; Also Includes: Operator Manual, 2 Pair Operator Eyewear, 1 Pair Patient Eye Shields, (1) Key, and 120 Day Warranty |
| Content | 2017 Lumenis M22 IPL with ResurFX| Manufacturer Notes |
|---|
| M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal.Available Treatments with M22:– Acne Scar Treatment
– Hair Removal
– Non-Ablative Skin Resurfacing
– Photorejuvenation
– Pigmentation Treatment
– Scar Revision
– Vascular / Leg Vein Treatment
– Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge.Universal IPL
Optimal Pulse Technology (OPT)
Single handpiece with changeable filters and lightguides
For IPL skin treatments using photorejuvenationResurFX
The only True fractional non-ablative, with CoolScan scanner
No disposables
For skin resurfacingMulti-Spot Nd:YAG
The only one with Multiple Sequential Pulsing (MSP)
2 sized lightguides, changeable in seconds
For treatment of leg veins and vascular lesionsQ-Switched Nd:YAG
Homogenous beam profile for enhanced treatment safety and efficacy
For skin toning*, dark tattoos removal, and combination treatments
*Skin toning by treatment of pigmented lesions |
2017 Lumenis M22 IPL with ResurFX and Q-Switched Nd:YAG A modular multi-application system for hair removal and various skin conditions Details:M22 Serial Number: 21171 M22 Date of Manufacture: 2017-07-17 Total IPL Pulses: 19,186 Total ResurFX Pulses: 10,772 Q-Switched Nd:YAG Pulses: 385,505
Includes:IPL Handpiece Complete Standard IPL filters: 515, 560, 590, 615, 640, 695, 755nm, and Calibration Specialty IPL Filters: Acne and Vascular IPL Light Guides: (1)35 x 15 mm2; (1)15 x 8 mm2, (1) 6mm- round ResurFX Handpiece with SapphireCool Tip Q-Switched Nd:YAG Handpiece Foot Switch Power Cord 30 Days Parts and Labor Warranty
|
System specifications
Dimensions:[without ResurFX] 44 x 50.5 x 47 cm (17 x 20 x 18.5 inches)
Dimensions:[with ResurFX] 44 x 50.5 x 61.5 cm (17 X 20 X 24 inches)
Weight:[without ResurFX] 40 kg / 88 lbs
Weight:[with ResurFX] 55 kg / 121 lbs
Electrical requirements:100 240 VAC ±10%, 15A max., 50/60 Hz, single phase, dedicated line M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal. Available Treatments with M22:– Acne Scar Treatment
– Hair Removal
– Non-Ablative Skin Resurfacing
– Photorejuvenation
– Pigmentation Treatment
– Scar Revision
– Vascular / Leg Vein Treatment
– Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge. Universal IPL
Optimal Pulse Technology (OPT)
Single handpiece with changeable filters and lightguides
For IPL skin treatments using photorejuvenation ResurFX
The only True fractional non-ablative, with CoolScan scanner
No disposables
For skin resurfacing Multi-Spot Nd:YAG
The only one with Multiple Sequential Pulsing (MSP)
2 sized lightguides, changeable in seconds
For treatment of leg veins and vascular lesions | Lutronic Clarity II
Lutronic’s Clarity II is a high-powered, dual-wavelength platform that effectively delivers a wider range of parameters to help safely and efficiently treat the broadest indications with ease. The innovative design includes: a single fiber for all spot sizes(2-25mm), intuitive interface, and no need for calibration after any parameter change. Clarity II can save time and help facilitate faster, more effective treatments.
Higher power 755/1064nm platform for effective treatments up to 45%* faster.
Brilliantly removes hair, pigment, and vascular lesions in all skin types.
IntelliTrak technology and Temperature Sensing enable increased provider confidence and treatment efficacy.Clarity II
Key Feature
1. Powerful and faster
Provide up to 25mm spot size at a useable >2 Hz
High power performance
Up to 45% faster
2. Intelligent and convenientIntelliTraking system to prevent skip area and consistent treatment
Real time skin temperature monitoring system
3. Designed for versatilityIntelligent memory function to keep track of past treatment history in detail
Zoom cartridge system for treatment areaLutronic Clarity IIHow It Works
The CLARITY II Laser System contains two separate laser resonators, Alexandrite and an Nd:YAG, which generate pulse laser energy at the nominal wavelength of 755nm and 1064nm respectively. The output of each laser generator and the 515nm aiming beam are optically combined on the laser rail so that their beam paths are identical as they exit the laser system. This allows the use of a single delivery system for either the 755nm or 1064nm wavelength.Clarity II
with IntelliTrak technologyHigher-powered 755/1064nm platform laser
Up to 2X faster Laser Hair Removal Txs*
Exclusive shorter pulsewidths available including 1ms setting
for finer facial hairs
Breakthrough intelligent capabilities
IntelliTrak technology for faster more consistent Tx coverage
Temperature Sensing for real-time skin temp feedback
during Tx
Auto-calibration in seconds saves time and
improves productivity
Advanced, easy-to-use platform
Single fiber for all 2-24mm spot cartridges
Numerous skin rejuvenation capabilities including vascular,
pigment, and toning Txs
*At settings of: 755nm, 5ms, 12J/cm2: Clarity II at 22mm, 3Hz, IntelliTrak at 18% overlap vs.
older system at 18mm, 2Hz, and est. ~18% manual overlap. Geometric treatment coverage speed is
11.4cm/second with Clarity II vs. 5.1cm/second with older system. | 2018 Edge for Life Hydrafacial MD EliteHydrafacial:HydroPeel tip resurfaces skin while simultaneously introducing topically applied serums For melasma, brown spots, wrinkles & fine lines, oily & acne- prone skin. Skin-specific serums for deep cleansing, exfoliating, extracting, hydrating, antioxidant treatment and more
Diamond Abrasion:Dry diamond crystal- free abrasion can be combined with wet HydraFacial treatment for deeper abrasion. Various crystal-free tips ranging from fine to extra coarse
LED Light Therapy:Red and infrared light, Blue light
Massage Therapy:Facial lymphatic drainage and Cellulite massage HydraFacial Elite is a non-invasive, multi-step treatment that combines the benefits of next-level hydradermabrasion, a chemical peel and painless extractions with a special delivery of antioxidants, hyaluronic acid and peptides. It delivers real results in less than 30 minutes without any downtime or irritation.The Elite uses Intuitive ISP technology that can be adapted to include new treatments and products as new trends emerge. The built-in skin imaging camera gives clients proof the treatments are working, and the photo comparison feature tracks clients progress visit after visit. Cordless LEDs are always ready for use when charged in their designated USB ports. The Elite also includes a pre-treatment video that educates clients on their treatments to make them feel more comfortable and better understand expectations.*Does the manufacturer EDGE SYSTEMS charge the new owner a ONE TIME equipment RECERTIFICATION FEE for SERVICE? Yes
Recertification Fee: $7,500
Consumables Required: Serums & Tips
Can Consumables be purchased through an outside source? Yes, a third party vendor is available who sells compatible tips and solutions at 60% off Edge Systems prices. Third party ordering: Ageless Serums, 6140 Highway 6, Ste 226, Missouri City, Texas 77459The HydraFacial ELITE equipment is an innovation in the medical-esthetic field, being the only hydradermabrasion equipment that combines cleaning, exfoliation, extraction and hydration procedures. Delicate and gentle with the skin, this noninvasive treatment was created to replace the traditional treatments in cosmetic salons by offering you a new experience in terms of facial cleaning. HydraFacial addresses all skin types: it maintains the health of normal skin, soothes and treats skin with acne issues, andrejuvenates mature skin and reduces fine wrinkles. Special applicators are used during the procedure, dedicated for each particular phase and unique for every patient, so that the latter have the security of a safe treatment carried out in conditions of maximum hygiene. TREATMENT STAGES 2018 Edge for Life Hydrafacial MD EliteStep 1. Cleaning and exfoliation: dead cells and impurities are removed from the skin surface Step 2. Peeling: the special acids clean the pores without irritating or damaging the tegument Step 3. Extraction: the special applicator reacts with the vortex technology and makes extractions on the pores, removing all skin impurities Step 4. Hydration: a mix of hydrating substances is inserted into the skin to nourish and protect the skin Step 5.Protection: use HydraFacial Daily Essentials products to enjoy longer-lasting results and protect your skin | Alma Opus Plasma Laser RF FractionalAlma Opus Plasma Laser RF Fractional Skin Resurfacing is the first-of-its-kind fractional plasma technology. It represents a new chapter for energy-based devices, addressing global or localized textural and skin quality concerns often corrected with conventional fractional resurfacing lasers in the past.Operating at a high frequency of over 40MHz, the metal pins on the Opus Plasma tips are super-charged with high-voltage. When in close proximity of the skin, the charged pins react to atmospheric pressure in the air, creating plasma that in turn, creates the microthermal zones of fractional injuries.Treatment delivers radio frequency energy at multiple levels to customize a treatment for your specific skincare concerns, using a range of settings to safely and effectively resurface the skin
Able to treat face, neck, decollete, hands, stomachs, etc.INDICATED USES
Fine Lines and wrinkles
Skin laxity
Uneven tone
Unwanted pigmentation
Stretch marks
Acne scarsWHAT IS OPUS PLASMA/HOW DOES IT WORKOpus Plasma represents a new chapter for energy-based devices, addressing global or localized textural and skin quality concerns often corrected with conventional fractional resurfacing lasers in the pastOperating at a high frequency of over 40MHz, the metal pins on the Opus Plasma tips are super-charged with high-voltage
When in close proximity of the skin, the charged pins react to atmospheric pressure in the air, creating plasma that in turn, creates the microthermal zones of fractional injuries
Our Opus treatment delivers radio frequency energy at multiple levels to customize a treatment for your specific skincare concerns, using a range of settings to safely and effectively resurface the skin
Able to treat face, neck, decollete, hands, stomachs, etc.DOES IT HURT/WHAT IS THE DOWNTIMEWe will apply a numbing cream before the treatment to make you as comfortable as possible, but you may still feel mild heat and pressure during the treatment
We also offer and highly recommend a prescription numbing cream
After a consultation, our Nurse will write you a prescription that we call in to Wellspring. This numbing cream is around $40 and allows us to turn up the machine resulting in a much better treatment
Most people tolerate the treatment well
You may experience some redness, but you can go back to your usual routine immediately after the treatment
You will appear to have a sunburn look
Your specialists will talk to you about aftercare at your consultation | FOTONA Lightwalker ATS Dual Wavelength Dental LaserFOTONA Lightwalker is the most advanced and highest performance LightWalker model. It comes equipped with high-performance Er:YAG and Nd:YAG lasers, a state-of-the-art OPTOflex articulated arm, an unrivaled 20W of power and Fotona patented QSP pulse technology for ultimate performance and treatment precision.LightWalker is the first dental laser system that works with a digitally controlled dental handpiece. Fotona’s revolutionary X-Runner technology, with ultrahigh-precision HDS (High Density Scanning) mode, increases the precision of dental laser treatments by helping to swiftly and accurately guide the laser beam across the treatment area according to perfectly shaped, predefined patterns.
LightWalker lasers are designed for ultimate versatility, with one of the most comprehensive lists of clinical applications available on any dental laser. With both tipped and tipless handpieces, your clinical options are endless. LightWalker offers the highest standard of dental treatment, and at the same time simplicity of use in:
Conservative Dentistry
Endodontics
Periodontics
Soft-tissue Surgery
Implantology
Aesthetic Treatments
Photobiomodulation.
Fast efficient cutting with unmatched patient comfort
With the advent of QSP technology and higher output power (several kW), the LightWalker ATS has established a new standard for ablation/cutting speed. This new accelerated cutting speed provides today’s dentists with the speed and precision they demand, while simultaneously increasing patient comfort.
Precise tissue surgery with simultaneous disinfection
The homogeneous absorption of the Nd:YAG laserin soft tissue results in controlled tissue vaporization with simultaneous coagulation for superior healing and disinfection.
Easy-to-use touch screen
LightWalker has an easy-to–use color touch- screen with an adjustable tilt and 80 customizable presettings that cover more than 40 different applications.
Easy access spray/heated water reservoir
The integrated spray water container means that you don’t have to rely on any water mains outlet, making your laser system exceptionally mobile and hasslefree. The container is handily located at the back of the system for easy refilling access. Additionally, the water is heated to body temperature, avoiding cold sensitivity reactions during procedures.
Patented weightless OPTOflex® arm
LightWalker’s unique and patented OPTOflex® Er:YAG articulated arm is designed to transmit a high-power laser beam to the handpiece, while maintaining the quality of the laser beam to ensure precision and repeatability even at the highest settings.
The OPTOflex arm is perfectly balanced during use, making handpieces completely weightless in your hand. OPTOflex allows a full range of motion and maximum degree of control as it makes maneuvering the handpiece much smoother, which improves treatment precision and ease.
Wireless footswitch
LightWalker also has an optional wireless footswitch that avoids unnecessary tangling of electric cables on your practice floor. Multifunctional Medical Laser Fotona LightWalker AT Hard and Soft-Tissue Dental Laser Dual-Wavelength Laser System : 15W 1064nm Nd:YAG + 20W 2940nm Er:YAG Package Includes: - Fotona LightWalker Laser Unit
- Wireless Footswitch
- R21-C2 Fiber Optic Nd:YAG Handpiece
- R21-C3 Fiber Optic Nd:YAG Handpiece
- H02 Tipless Er:YAG Handpiece
- H14 Tipped Er:YAG Handpiece with 4 Tips For Perio, Endo, Hard/Soft Tissue
- PS04 Pixel Structure Er:YAG Handpiece
- Accessories
- 3 Sets of Laser Safety Goggles
- Operators Manual
- 1 Year Warranty
| Lumenis Lightsheer Desire (Include Handpiece)
comes fully loaded with 3 handpieces – ET (9X9), XC (12X12) & HS (22X35)the LightSheer DESIRE uses an 805nm diode wavelength. This wavelength is the industry’s Gold-Standard and has been clinically proven to safely and effectively treat all skin types Available Treatments: - Hair removal, permanent hair reduction, and the treatment for Pseudofolliculitis Barbae(PFB).
- Treatment of vascular lesions, including angiomas, hemangiomas, telangiectasia, leg veins and other benign vascular lesions.
- Treatment of benign pigmented lesions.
Unique features: - The “Gold standard” 805nm diode laser.
- 3 handpieces with various spot sizes.
- 2 advanced technologies.
The ET has a Sapphire ChillTip spot size of 9x9mm designed to treat small areas that require maximum precision and high fluence.The XC has a Sapphire ChillTip spot size of 12x12mm, providing optimal solution for large and small areas requiring higher fluence levels.The HS has a HIT 22x35mm spot size enabling use of low-fluence and a unique mechanism of pain reduction, providing safe, fast and comfortable treatment. | Product Specifications |
|---|
| ET | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 9 mm X 9 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 Pulse | | Fluence | 10-100 J/cm2 | | Pulse Width | 5-400 ms | | Peak Power | 1600 W | | Comfort Management | Chilltip contact cooling (5O C) | | Preset Parameters | Yse |
| XC | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 12 mm X 12 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 Pulse | | Fluence | 10-40 J/cm2 | | Pulse Width | 5-400 ms | | Peak Power | 2400 W | | Comfort Management | Chilltip contact cooling (5O C) | | Preset Parameters | Yse |
| HS | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 22 mm X 35 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 – 3 pulses | | Fluence | 4.5-12 J/cm2 | | Pulse Width | 30-400 ms | | Peak Power | 2300 W | | Comfort Management | Vacuum assisted (up to18inHg) | | Preset Parameters | Yse |