| Description | 2017 Lumenis M22 with ResurFX & IPL in Like-New Condition; Manufactured 10/22/2017; Based Unit Serial Number 11860, IPL Handpiece Serial Number: 4751; Nd Yag Serial Number: Perfect Cosmetic and Operating Condition, Single Owner; Handpieces Included & Total Pulse Counts: IPL Handpiece Total Pulse Count = 908; ResurFX Handpiece Pulse Count = 16 Pulses; Includes Expert Filters: 515nm, 560nm, 590nm, 615nm, 640nm, 695nm, and 755nm; Also Includes: Footswitch, Interlock, Operator Manual. | Includes:
iFine Handpiece
Small-Medium Handpiece
Two Exchangable Connectors on each side suitable for all handpieces
2 Keys
Infared Handheld Sensor
Operators Manual | 2017 Lumenis Lightsheer Desire with 3 Handpieces – HS, XC and ET – Includes 805 and 1060 nm wavelengths – Like-New Condition; Serial Number: 3796, Date of Manufacture 2/15/2017, Excellent Cosmetic and Operating Condition – Like New with low pulses! RECENTLY INSPECTED April 2021, Included Handpieces & Pulse Counts: HS 22×35 mm Spot Size Diode Handpiece = 132 Pulses; XC 12×12 mm Spot Size Diode Handpiece = 3,362 Pulses; ET 9×9 mm Spot Size 1060 Handpiece = 6,590 Pulses; Also Includes: Operator Manual, 2 Pair Operator Eyewear, 1 Pair Patient Eye Shields, (1) Key, and 120 Day Warranty | Included Handpieces:
HS 22×35 mm Spot Size Diode Handpiece
XC 12×12 mm Spot Size Diode HandpieceAlso Includes:
Operator Manual
2 Pair Operator Eyewear
1 Pair Patient Eye Shields
2 Keys | Includes:
1 Fractional Scanner Handpiece for Ablative Skin Resurfacing
1 Incisional Handpiece with up to or less than .2mm Spot Size
Handpiece Case
Distance Gauges
Footswitch
Patient Eyewear
Operator Eyewear
Operator Manual
Warning Sign | - Muscoskeletal Disorders
- Degenerative arthritis
- Rheumatoid arthritis
- Cervical pain
- Sport injuries
- Frozen shoulder
- Muscle relaxation
- Pain management
|
| Content | 2017 Lumenis M22 IPL with ResurFX| Manufacturer Notes |
|---|
| M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal.Available Treatments with M22:– Acne Scar Treatment
– Hair Removal
– Non-Ablative Skin Resurfacing
– Photorejuvenation
– Pigmentation Treatment
– Scar Revision
– Vascular / Leg Vein Treatment
– Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge.Universal IPL
Optimal Pulse Technology (OPT)
Single handpiece with changeable filters and lightguides
For IPL skin treatments using photorejuvenationResurFX
The only True fractional non-ablative, with CoolScan scanner
No disposables
For skin resurfacingMulti-Spot Nd:YAG
The only one with Multiple Sequential Pulsing (MSP)
2 sized lightguides, changeable in seconds
For treatment of leg veins and vascular lesionsQ-Switched Nd:YAG
Homogenous beam profile for enhanced treatment safety and efficacy
For skin toning*, dark tattoos removal, and combination treatments
*Skin toning by treatment of pigmented lesions |
2017 Lumenis M22 IPL with ResurFX and Q-Switched Nd:YAG A modular multi-application system for hair removal and various skin conditions Details:M22 Serial Number: 21171 M22 Date of Manufacture: 2017-07-17 Total IPL Pulses: 19,186 Total ResurFX Pulses: 10,772 Q-Switched Nd:YAG Pulses: 385,505
Includes:IPL Handpiece Complete Standard IPL filters: 515, 560, 590, 615, 640, 695, 755nm, and Calibration Specialty IPL Filters: Acne and Vascular IPL Light Guides: (1)35 x 15 mm2; (1)15 x 8 mm2, (1) 6mm- round ResurFX Handpiece with SapphireCool Tip Q-Switched Nd:YAG Handpiece Foot Switch Power Cord 30 Days Parts and Labor Warranty
|
System specifications
Dimensions:[without ResurFX] 44 x 50.5 x 47 cm (17 x 20 x 18.5 inches)
Dimensions:[with ResurFX] 44 x 50.5 x 61.5 cm (17 X 20 X 24 inches)
Weight:[without ResurFX] 40 kg / 88 lbs
Weight:[with ResurFX] 55 kg / 121 lbs
Electrical requirements:100 240 VAC ±10%, 15A max., 50/60 Hz, single phase, dedicated line M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal. Available Treatments with M22:– Acne Scar Treatment
– Hair Removal
– Non-Ablative Skin Resurfacing
– Photorejuvenation
– Pigmentation Treatment
– Scar Revision
– Vascular / Leg Vein Treatment
– Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge. Universal IPL
Optimal Pulse Technology (OPT)
Single handpiece with changeable filters and lightguides
For IPL skin treatments using photorejuvenation ResurFX
The only True fractional non-ablative, with CoolScan scanner
No disposables
For skin resurfacing Multi-Spot Nd:YAG
The only one with Multiple Sequential Pulsing (MSP)
2 sized lightguides, changeable in seconds
For treatment of leg veins and vascular lesions | ENDYMED PURE PLUS LASER
GOOD THINGS COMES IN SMALL PACKAGES THE PURE+
The Pure+ by Endymed Pure Plus, powered by our FDA cleared, patented 3DEEPRF technology. The PURE+ offers professional grade Fractional Skin Resurfacing and superior body, facial and neck tightening and contouring treatments, all on one easy to use, compact platform.The PURE+ offers complete flexibility with exchangeable treatment handpieces one PURE+ console can be configured any way you like to provide you and your clients with the most effective and popular treatments available today.The PURE+ is offered in two configurations:FSR + TC: Fixed FSR handpiece + one exchangeable connector suitable for all TC handpieces: iFine, Small and Large
TC Complete: Two exchangeable connectors on each side, suitable for all TC handpieces: iFine, Shaper, Small and LargeEndymed Pure Plus LaserIncludes:
iFine Handpiece
Small-Medium Handpiece
Two Exchangable Connectors on each side suitable for all handpieces
2 Keys
Infared Handheld Sensor
Operators ManualInput Power:100-120V, 50-60Hz, 2A or 220-240V, 50-60Hz, 1A
Power Consumption:220 W
Fuses:2 x 1.6A for 220V; 2 x 3.15A for 110V
Output Power:Up to 50 Watts
Output Frequency:1MHz
Working Temperature:+10°C – +25°C
Dimensions:(H x W x D) 600 x 305 x 365 mm
Weight:10 kgThe iFine treatment Handpiece –
specially engineered to target fine lines and wrinkles found in the delicate thin skin areas around the eyes, providing:
Smoother, tighter skin around the eyes.
Reduced under eye sagging and improved eye contour.
Reduced hooding to reveal more of the eyelid.
More youthful, less tired looking eyes.
Softening of fine line enabling easier application of make-up.3Deep Small-Medium Handpiece
Designed to treat wrinkles and lax skin on the face, neck and upper body.3Deep Fractional Skin Resurfacing Handpiece
Specially designed for fractional skin resurfacing and treatment of skin roughness, hyperpigmentation, and wrinkles and scars on both facial and body. The FSR handpiece contains a matrix of 112 tiny electrodes, allowing for the first time simultaneous fractional micro-ablation of the epidermis, together with volumetric heating of 100% of the dermis. This technology provides the capability to differentiate between micro-ablation and dermal heating which appears to be the optimal multi-layer treatment to affect aging skin and atrophic acne scars.3Deep Shaper Handpiece
Major innovation in RF skin tightening, body shaping and contouring, and cellulite treatment for large body areas. The handpieces unique engineered electrode surface is 40.7 cm2 allowing for shorter treatment times (20 minute abdomen treatment, 30 minute cellulite treatments for the thighs and buttocks). Deeper, controlled energy penetration tightens and firms the skin by stimulating the bodys natural collagen renewal process, providing better and more effective results. | Lumenis Lightsheer Desire (Include Handpiece)
comes fully loaded with 3 handpieces – ET (9X9), XC (12X12) & HS (22X35)the LightSheer DESIRE uses an 805nm diode wavelength. This wavelength is the industry’s Gold-Standard and has been clinically proven to safely and effectively treat all skin types Available Treatments: - Hair removal, permanent hair reduction, and the treatment for Pseudofolliculitis Barbae(PFB).
- Treatment of vascular lesions, including angiomas, hemangiomas, telangiectasia, leg veins and other benign vascular lesions.
- Treatment of benign pigmented lesions.
Unique features: - The “Gold standard” 805nm diode laser.
- 3 handpieces with various spot sizes.
- 2 advanced technologies.
The ET has a Sapphire ChillTip spot size of 9x9mm designed to treat small areas that require maximum precision and high fluence.The XC has a Sapphire ChillTip spot size of 12x12mm, providing optimal solution for large and small areas requiring higher fluence levels.The HS has a HIT 22x35mm spot size enabling use of low-fluence and a unique mechanism of pain reduction, providing safe, fast and comfortable treatment. | Product Specifications |
|---|
| ET | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 9 mm X 9 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 Pulse | | Fluence | 10-100 J/cm2 | | Pulse Width | 5-400 ms | | Peak Power | 1600 W | | Comfort Management | Chilltip contact cooling (5O C) | | Preset Parameters | Yse |
| XC | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 12 mm X 12 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 Pulse | | Fluence | 10-40 J/cm2 | | Pulse Width | 5-400 ms | | Peak Power | 2400 W | | Comfort Management | Chilltip contact cooling (5O C) | | Preset Parameters | Yse |
| HS | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 22 mm X 35 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 – 3 pulses | | Fluence | 4.5-12 J/cm2 | | Pulse Width | 30-400 ms | | Peak Power | 2300 W | | Comfort Management | Vacuum assisted (up to18inHg) | | Preset Parameters | Yse |
Lumenis Lightsheer Desire (Include Handpiece) – Like New | 2016 LUMENIS LIGHTSHEER DESIRE PERMANENT LASER HAIR REDUCTION2016 Lumenis Lightsheer Desire Permanent Laser Hair Reduction
Great clinical results begin with the LightSheer 805 nm diode laser empowered by two advanced technologies.The Gold Standard in Permanent Laser Hair Reduction
More and more people desire to have permanent hair reduction. They want a treatment that is effective, fast and comfortable. To meet these needs, Lumenis, a leader in laser and energy based technologies, developed the LightSheer DESIRE, the new generation of Laser Hair Reduction systems, so you can grow your business by offering your patients what they DESIRE. The Gold Standard in Permanent Laser Hair Reduction.Included Handpieces:
HS 22×35 mm Spot Size Diode Handpiece
XC 12×12 mm Spot Size Diode HandpieceAlso Includes:
Operator Manual
2 Pair Operator Eyewear
1 Pair Patient Eye Shields
2 KeysSuperior Performance
– Versatile 805nm diode laser
– 2 different Models to select from
– Multiple handpieces with various spot sizes
– 2 advanced technologies
– Upgradable features: add capabilities as your practice grows.Advanced Laser Hair Removal TechnologyGreat clinical results begin with the LightSheer 805 nm diode laser empowered by two advanced technologies:
1. Vacuum Assisted High-Speed Integrated Technology – A large 22×35 mm spot size enables the use of low-fluence and a unique mechanism for pain reduction which provides effective, fast and comfortable treatments for your clients.
2. ChillTip™ Technology – Integrated contact cooling provides epidermal protection for treatment areas requiring precision and higher fluence.Lightsheer Desire Specifications
High Speed (HS) Handpiece
Laser Type:Diode
Wavelength:805 nm
Spot Size:22 x 23 mm
Repetition Rate:Up to 3 Hz
Pulse Repetition:1-3 Pulses
Fluence:4.5-12 J/cm2
Pulse Width:30-400 ms
Peak Power:2310 WXC Handpiece
Laser Type:Diode
Wavelength:805 nm
Spot Size:12 x 12 mm
Repetition Rate:Up to 3 Hz
Pulse Repetition:1 Pulse
Fluence:10-40 J/cm2
Pulse Width:5-400 ms
Peak Power:1920 WLightSheer® DESIREThe starting point to your successMore and more people desire to have permanent hair reduction. They want a treatment that is effective, fast and comfortable.To meet these needs, Lumenis, a leader in laser and energy based technologies, developed the LightSheer DESIRE, the new generation of Laser Hair Reduction system from the LightSheer Family of products, so you can grow your business by offering your patients what they DESIRE. | EMVERA CLARO2 CO2 LASER
Claro2 Medical Laser System
The Claro2 laser technology offers the most innovative approach to laser treatments today. It provides an acceptable and comfortable procedure under little or no anesthesia with minimum pain from evaporation of the skin layers, resulting in minimal social or work downtime. The laser delivers a series of microscopic, closely-spaced laser spots to the skin while simultaneously preserving the normal, healthy skin. The undamaged skin becomes a reservoir of tissue for fast heating and regeneration of the treated area by producing and providing new dermal collagen and eliminating epidermal pigmentation and irregularities to the skin tone. The Claro2 laser system is specially designed to improve skin texture and tone, and fight wrinkles, scars and pigmentations. Since the treatment procedures are customized to patients skin, operators are able to adjust laser settings to tailor treatments and achieve superior results.Claro2 Laser Features Provide:
Unparalleled char-free ablation, vaporization, excision, or incision of soft tissues
Reduced thermal damage to surrounding tissues
Rapid healing and minimal downtime
Stimulation of deeper collagen with high pulse energy
Large TFT LCD touch screen provides easy operation with the latest high speed microprocessor technology
Adjustable scanning patterns and sizes
Adjustable intensity of pilot beam
Adjustable pulse duration
Last treatment setting memorization
Automatic alarm system for operation and errors
No consumable costsIncludes:
1 Fractional Scanner Handpiece for Ablative Skin Resurfacing
1 Incisional Handpiece with up to or less than .2mm Spot Size
Handpiece Case
Distance Gauges
Footswitch
Patient Eyewear
Operator Eyewear
Operator Manual
Warning SignLaser Type:Sealed of Co2 Laser
Wavelength:10.6 um
Mode Structure:TEM00
Max Power:0-30W (adjustable)
Spot Size:Equal to or less than .2mm
Aiming Beam:630nm Red Laser (Adjustable Brightness)
Delivery System:Articulated Arm
Operation Modes:Continuous Wave, Single Pulse, Repetition Pulse, Super Pulse, Scanner
Pulse Width:Single Pulse (0.01-1s); Repetition Pulse (0.001-1s); Scanner (0.0001-0.01s)
Scan Size: Adjustable
Scan Pattern:Oval, Triangle, Rectangle, Line
Scan Array Density:Adjustable
Cooling System:Self-Contained, Closed Cycle
Power Supply:100-120V AC, 50/60Hz or 200-240V AC, 50/60Hz
Environment Temperature:10-40 Degrees Celsius
Relative Humidity:Below 80%
Dimensions:561mm x 500mm x 1443mm
Weight:42kgApplications Include:EMVERA CLARO2 CO2 LASERDermatology, Plastic Surgery and General Surgery procedures including but not limited to:
Laser skin resurfacing
Treatment of furrows and wrinkles
Removal of skin tags, actinic keratosis, acne scars, keloids, tattoos, telangiectasia, squamous and basel cell carcinoma, warts and uneven pigmentation
Treatment of cysts, abscesses, hemorrhoids and other soft tissue applications
Blepharoplasty
Site preparation for hair transplantsOtorhinolaryngology (ENT) procedures including but not limited to:
Treatment of leukoplakia of larynx, nasal obstruction, rhinophyma, verrucrea vulgares, choanal atresia, rhinophyma, LAUP and papillomatosis polypsGynecology:
Treatment of condyloma acuminate, cervical
intraepithelial neoplasia, leukoplakia and vulvar/
vaginal intraepithelial neoplasia, cervical dysplasia
Podiatry procedures including but not limited to:
Ablation, vaporization and excision of soft
tissue lesions such as ingrown nail, fungal nail,
porokcratoma, matrixectomy and verrucae vulgares | 2020 CRYOMED HYPERMAX TALENTPRO
Electro-Magnetic Stimulation Technology
hyperMAX utilises Electro-Magnetic Stimulation technology to induce supramaximal contractions for
the growth and development of muscles. The magnetic field changes quickly inducing electrical currents in the tissue where neuronal membranes are depolarised and motor units in the target muscles are controlled to cause concentric contractions.How does it work?
Electro-Magnetic Stimulation helps to rebuild and repair muscle tissue, resulting in stronger and firmer muscles.
The strong Electro-Magnetic stimulation, of up to 3 Tesla, works deep to the hypodermis, influencing
muscle fibres and cell membranes to optimise cellular metabolism, supplying more oxygen for better blood circulation.Dualsculpt with Applicators
hyperMAX utilises Electro-Magnetic Stimulation technology to induce supramaximal contractions for the growth and development of muscles. The magnetic field changes quickly inducing electrical currents in the tissue where neuronal membranes are depolarised
and motor units in the target muscles are controlled to cause concentric contractions.2020 Cryomed HyperMAX TalentproIndications:- Muscoskeletal Disorders
- Degenerative arthritis
- Rheumatoid arthritis
- Cervical pain
- Sport injuries
- Frozen shoulder
- Muscle relaxation
- Pain management
Spinal Disorders- Acute/chronic lumbago
- Sciatica
- Spinal bifida
- Spondylitis chronic back pain
- Spinal disc disease
- Intramuscular stimulation
- Trigger Point Injection
Electro-Magnetic Stimulation TechnologyhyperMAX utilises Electro-Magnetic Stimulation technology to induce supramaximal contractions for
the growth and development of muscles. The magnetic field changes quickly inducing electrical currents in the tissue where neuronal membranes are depolarised and motor units in the target muscles are controlled to cause concentric contractions.How does it work?Electro-Magnetic Stimulation helps to rebuild and repair muscle tissue, resulting in stronger and firmer muscles.
The strong Electro-Magnetic stimulation, of up to 3 Tesla, works deep to the hypodermis, influencing
muscle fibres and cell membranes to optimise cellular metabolism, supplying more oxygen for better blood circulation. |
Reviews
There are no reviews yet.