| Content | Zimmer zwave pro laser system body contouring
The high energy radial shockwaves scientifically proved to have a large impact on collagen structure and the skin connective tissue, improving blood circulation.
It stimulates collagen formation, while the skin becomes more elastic and its firmness is visible after only a few treatments.
Thanks to the ZWave radial shockwave unit, it is also possible to significantly improve skin firmness, skin elasticity and collagen regeneration. Fat reduction, for example, after CryolipolysisTM or injection lipolysis is also enhanced by using the ZWave.ZWave & ZLipo – the perfect combination
Skin tightening and body contouring are becoming increasingly important in the modern practice. After several treatments for fat reduction, such as e.g. CryolipolysisTM, liposuction, or injection lipolysis, a more extensive application for skin tightening is urgently recommended and expected by the patient. Various studies and user observations have proven its effectiveness.Skin tightening and body contouring
ZWave is used as a “stand-alone” application or in combination with other, mostly fat reduction methods. In the case of the “stand-alone” application, the focus is generally on improving the skin structure and connective tissue. Typical application areas are, e.g. cellulite, connective tissue weakness (upper arm, underbelly, etc.) and stretch marks (striae).Zimmer ZWave Pro Laser System Body ContouringTechnology:Electro-magnetically generated Radial Pulse Technology, 1-22 Hz, 60-185mJ
Programs:3 recommended application presets
Controller:12 color touch screen for all software operations. Full range control for energy and frequency.
Foot switch:control for hand piece.
Memory and Update:SD card for custom programs by user/error log/firmware updates
Voltage:110 volts, 60 Hz
Dimensions & Weight:L 20.5 / W 21 / H 54.5 Weight: 70 lbs.
Z Wave Pro Catch the Z Wave
The Zimmer ZWave Pro Body Contouring transmits powerful sound waves into the tissue. The energy then spreads out radially to enhance the treatment effect.
The body responds to the Z Wave Pro sound waves with increased metabolic activity in the form of lymphatic drainage and increased blood circulation.
The end result is an improvement in the appearance of cellulite and other body contouring procedures.
Z Wave & Cryolipolysis Enhanced Results
Thanks to Z Wave, it is possible to significantly enhance body contouring results with CryolipolysisTM and RF treatments.
Various studies have shown its effectiveness with body contouring treatments.Application Range
Cellulite Treatment and Enhanced Body Shaping
Z Wave is used as a stand-alone application or in combination with body contouring treatments. As a stand-alone application, the focus is on improving the appearance of cellulite.Patient-friendly Application
Zimmer ZWave Pro Body Contouring Radial Pulse Technology has the following advantages:gentle, painless and quick treatments
no disposables
no down time
non-invasive treatment
visible results
versatile
easy to operate
superior alternative to hand massage post body sculpting
consistently reproducible resultsHand Piece Characteristics
efficient energy transfer from hand piece to deep tissue structures up to 35 mm
treatment is comfortable for both patient and technician
hand piece is controlled via foot switch
each Z Wave Pro comes with 2 hand pieces and is ready for use any time
each hand piece is warranted for 2,000,000 pulses. The two hand pieces should yield approximately 1,600 application zones
enhanced patient comfort due to longer rise time (pulse width) without the need for unpleasant high peak energy | 2017 Lumenis M22 IPL with ResurFX| Manufacturer Notes |
|---|
| M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal.Available Treatments with M22:– Acne Scar Treatment
– Hair Removal
– Non-Ablative Skin Resurfacing
– Photorejuvenation
– Pigmentation Treatment
– Scar Revision
– Vascular / Leg Vein Treatment
– Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge.Universal IPL
Optimal Pulse Technology (OPT)
Single handpiece with changeable filters and lightguides
For IPL skin treatments using photorejuvenationResurFX
The only True fractional non-ablative, with CoolScan scanner
No disposables
For skin resurfacingMulti-Spot Nd:YAG
The only one with Multiple Sequential Pulsing (MSP)
2 sized lightguides, changeable in seconds
For treatment of leg veins and vascular lesionsQ-Switched Nd:YAG
Homogenous beam profile for enhanced treatment safety and efficacy
For skin toning*, dark tattoos removal, and combination treatments
*Skin toning by treatment of pigmented lesions |
2017 Lumenis M22 IPL with ResurFX and Q-Switched Nd:YAG A modular multi-application system for hair removal and various skin conditions Details:M22 Serial Number: 21171 M22 Date of Manufacture: 2017-07-17 Total IPL Pulses: 19,186 Total ResurFX Pulses: 10,772 Q-Switched Nd:YAG Pulses: 385,505
Includes:IPL Handpiece Complete Standard IPL filters: 515, 560, 590, 615, 640, 695, 755nm, and Calibration Specialty IPL Filters: Acne and Vascular IPL Light Guides: (1)35 x 15 mm2; (1)15 x 8 mm2, (1) 6mm- round ResurFX Handpiece with SapphireCool Tip Q-Switched Nd:YAG Handpiece Foot Switch Power Cord 30 Days Parts and Labor Warranty
|
System specifications
Dimensions:[without ResurFX] 44 x 50.5 x 47 cm (17 x 20 x 18.5 inches)
Dimensions:[with ResurFX] 44 x 50.5 x 61.5 cm (17 X 20 X 24 inches)
Weight:[without ResurFX] 40 kg / 88 lbs
Weight:[with ResurFX] 55 kg / 121 lbs
Electrical requirements:100 240 VAC ±10%, 15A max., 50/60 Hz, single phase, dedicated line M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal. Available Treatments with M22:– Acne Scar Treatment
– Hair Removal
– Non-Ablative Skin Resurfacing
– Photorejuvenation
– Pigmentation Treatment
– Scar Revision
– Vascular / Leg Vein Treatment
– Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge. Universal IPL
Optimal Pulse Technology (OPT)
Single handpiece with changeable filters and lightguides
For IPL skin treatments using photorejuvenation ResurFX
The only True fractional non-ablative, with CoolScan scanner
No disposables
For skin resurfacing Multi-Spot Nd:YAG
The only one with Multiple Sequential Pulsing (MSP)
2 sized lightguides, changeable in seconds
For treatment of leg veins and vascular lesions | ACTIVE OPTICAL EXTRA 818 IPL HAIR REMOVAL MACHINEIncludes:
Footswitch
Operators Manual
AntiFreeze Coolant
Patient & Operator EyewearHandpieces:Hair Removal Handpiece and Facial Handpiece
Chilled Tip:Up to 4c
Pulse Interval:0.5~2 Seconds
Output Power:11-31 joule/cm2, upto 4,000W
Cooling System:Revolutionary dual cooling
Control:Intuitive touch screen control
Lamp’s Life Span:250,000 Flashes (Universal), 200,000 Flashes (Facial)
Treatment Area:7.5 cm2 (15*50mm) Universal, 4.5 cm2 (15*30mm) Facial
Wavelength:420-1100 nm
Weight:42Kg (including Stand, if device is not a table top)
Dimensions:44cm x 45cm x 100cm
Extra-818
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Vascular (Facial) TreatmentThe combination of tested treatment protocols with high end engineering makes the Extra – 818 the perfect device for leading clinics.Revolutionary Cooling System
The Extra – 818 has a dual cooling system, controlled and monitored in order to ensure long lifetime to the lamp and a comfortable treatment to the patient.Competitive cooling systems “freeze” the skin so that during the treatment the skin temperature will rise to a bearable level. However, this “freezing” temperature might limit the results because the follicles will not reach the coagulation temperature. To ensure optimal results Active installed a special Processor that prevents overcooling the skin and maintains a uniform low temperature of the “glass” throughout the treatment. This revolutionary system enables the Extra – 818 to provide best results with optimal patient comfort.Research Program ACTIVE OPTICAL EXTRA 818 IPL HAIR REMOVAL MACHINE
For clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device.
The energy levels in the self setting program can reach 31Jcm2 with high intensity of 4,000W.The Active Optical Extra 818 IPL Hair Removal and Skin Rejuvenation is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features:
* Contemporary touch screen control
* Built-in Patch Test procedure for examining the optimal energy level
* A stunning number of 450,000 flashes in both lamps.The Extra – 818, based on Active’s GEM-PL technology, sets sets a specific Pulse Pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth.
The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings. | ERCHONIA ZERONA Z5 LASER
The Erchonia Zerona Cosmetic Laser model is designed for use during non-invasive body contouring. It is a body sculpting machine designed to remove fat and contour the body without the invasive surgery that many patients prefer not to go under.Zerona is the only clinically-proven non-invasive body contouring treatment, providing 6 quick & painless treatments. These treatments specifically target stubborn fat areas and painlessly emulsify the fat under your skin using the Lymphatic system.ZERONA is the first non-invasive body slimming procedure to effectively remove excess fat!
Unlike other lipo and body slimming procedures, ZERONA allows patients to continue daily activities without interruptions from surgery, pain, wounds, bruises, or garments. The ZERONA protocol utilizes the Erchonia Laser Scanner, which is the safest and most researched low level laser in the world. ZERONA is also FDA approved for laser assisted liposuction. Find out how it worksVoluminous adipose tissue can appear when fatty material is present, and this, in turn, can bring about enlarged subcutaneous fat regions. Because subcutaneous fat is close to the skin’s surface, laser emulsification can have a dramatic effect on them. The collapse of adipose arrangements has been noted after laser therapy, reducing their volume and providing effective body slimming results. When the fat cells have reduced the body naturally excretes the fat over time giving the patient proven results after around six treatments over two weeks. This occurs during the bodys normal detoxification process.Configuration:5 3b Line Generated Laser Diode Modules
Wavelength:635nm
Modulation:Constant Wave (CW) 1,000 Hz
Programming:5 time saving presets
Display:8″ Full color TFT Touch Screen Control Center
Power Source:100-240VAC 50-60Hz
Chassis:Power Coated metal frame for ease of cleaning
Housing:Thermoformed of Non-allergen material/plastic
Accessories:2 Keys, Laser Safety Glasses
Dimensions:49 x 32 x 57H”
Weight:266 lbs.ERCHONIA ZERONA Z5Let’s take a closer lookERCHONIA ZERONA Z5 LASERFour separate histological studies were performed to assess the efficacy of laser in the emulsification (liquefaction) of fat. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were utilized to analyze adipose tissue. SEM and TEM images revealed the collapse of adipose arrangements subsequent to laser therapy. The voluminous state of an adipocyte cell is reduced due to the emulsification process. The fatty material is evacuated from the cell and moves into extracellular space. The voluminous nature of adipocytes due to the accumulation of fatty material is what gives rise to an enlarged subcutaneous fat region. ZERONA induces the formation of a transitory pore in the membrane of the fat cell. The pore enables the fatty material to seep out across the aperture and into extracellular space. The following images show the result of laser energy on a single fat cell and a group of fat cells.As you can see the ZERONA treatment liquifies the fat and the cell dumps it into the intercellular space. There are two types of fat cells – Subcutaneous and Visceral.Subcutaneous fat is located directly above the skeletal muscle and below the skin. Its superficial placement is what ensures proper depth penetration of the laser energy. Patients containing a high volume of visceral fat (fat below the skeletal muscle) are not ideal candidates for this procedure. However, they may still contain subcutaneous fat; therefore, you can treat the individual by just ensuring they adopt a healthy diet to address the visceral fat. | EMVERA CLARO2 CO2 LASER
Claro2 Medical Laser System
The Claro2 laser technology offers the most innovative approach to laser treatments today. It provides an acceptable and comfortable procedure under little or no anesthesia with minimum pain from evaporation of the skin layers, resulting in minimal social or work downtime. The laser delivers a series of microscopic, closely-spaced laser spots to the skin while simultaneously preserving the normal, healthy skin. The undamaged skin becomes a reservoir of tissue for fast heating and regeneration of the treated area by producing and providing new dermal collagen and eliminating epidermal pigmentation and irregularities to the skin tone. The Claro2 laser system is specially designed to improve skin texture and tone, and fight wrinkles, scars and pigmentations. Since the treatment procedures are customized to patients skin, operators are able to adjust laser settings to tailor treatments and achieve superior results.Claro2 Laser Features Provide:
Unparalleled char-free ablation, vaporization, excision, or incision of soft tissues
Reduced thermal damage to surrounding tissues
Rapid healing and minimal downtime
Stimulation of deeper collagen with high pulse energy
Large TFT LCD touch screen provides easy operation with the latest high speed microprocessor technology
Adjustable scanning patterns and sizes
Adjustable intensity of pilot beam
Adjustable pulse duration
Last treatment setting memorization
Automatic alarm system for operation and errors
No consumable costsIncludes:
1 Fractional Scanner Handpiece for Ablative Skin Resurfacing
1 Incisional Handpiece with up to or less than .2mm Spot Size
Handpiece Case
Distance Gauges
Footswitch
Patient Eyewear
Operator Eyewear
Operator Manual
Warning SignLaser Type:Sealed of Co2 Laser
Wavelength:10.6 um
Mode Structure:TEM00
Max Power:0-30W (adjustable)
Spot Size:Equal to or less than .2mm
Aiming Beam:630nm Red Laser (Adjustable Brightness)
Delivery System:Articulated Arm
Operation Modes:Continuous Wave, Single Pulse, Repetition Pulse, Super Pulse, Scanner
Pulse Width:Single Pulse (0.01-1s); Repetition Pulse (0.001-1s); Scanner (0.0001-0.01s)
Scan Size: Adjustable
Scan Pattern:Oval, Triangle, Rectangle, Line
Scan Array Density:Adjustable
Cooling System:Self-Contained, Closed Cycle
Power Supply:100-120V AC, 50/60Hz or 200-240V AC, 50/60Hz
Environment Temperature:10-40 Degrees Celsius
Relative Humidity:Below 80%
Dimensions:561mm x 500mm x 1443mm
Weight:42kgApplications Include:EMVERA CLARO2 CO2 LASERDermatology, Plastic Surgery and General Surgery procedures including but not limited to:
Laser skin resurfacing
Treatment of furrows and wrinkles
Removal of skin tags, actinic keratosis, acne scars, keloids, tattoos, telangiectasia, squamous and basel cell carcinoma, warts and uneven pigmentation
Treatment of cysts, abscesses, hemorrhoids and other soft tissue applications
Blepharoplasty
Site preparation for hair transplantsOtorhinolaryngology (ENT) procedures including but not limited to:
Treatment of leukoplakia of larynx, nasal obstruction, rhinophyma, verrucrea vulgares, choanal atresia, rhinophyma, LAUP and papillomatosis polypsGynecology:
Treatment of condyloma acuminate, cervical
intraepithelial neoplasia, leukoplakia and vulvar/
vaginal intraepithelial neoplasia, cervical dysplasia
Podiatry procedures including but not limited to:
Ablation, vaporization and excision of soft
tissue lesions such as ingrown nail, fungal nail,
porokcratoma, matrixectomy and verrucae vulgares | LUMENIS ACUPULSE 120 CO2 MACHINE
Includes:
Articulated Arm
2 Acuscan 120 Handpieces
125mm Incisional Handpiece
F-125 Attachments
KeySuperPulseTM TechnologyExceptional ablation/coagulation ratio.
Reach the desired treatment depth with a single pulse.
11 Built-in Treatment Modes.Maximum versatility with only two scanners.
Full parameter control for advanced users.
Short Pulse Duration.Enhanced patient comfort.
Lower chance of side effects.
Intuitive User Interface.Easy setup and quick treatments.
User presets for single-click treatments.11 Treatment Modes For Maximum Versatility
ACUSCAN120 FRACTIONAL SCANNERLUMENIS ACUPULSE 120 CO2 MACHINELaser Type:Co2
Wavelength:10,600 nm
AcuPulse
MultiModeTM SuperPulseTM CO2 Laser
AcuPulse is a complete ablative laser resurfacing workstation, featuring state of the art technology for all aesthetic resurfacing needs.
POWERFUL. VERSATILE. SIMPLE.Superficialfor moderate sun damage, fine lines, uneven texture, dyschromia, actinic keratosis and more.ComboDeep and Superficial combined together for sun damage, acne scars, wrinkles and more.Deepfor deeper lines and wrinkles, acne scars, uneven texture, dyschromia and more.StretchTouchfor skin furrows and textural irregularities.SURGITOUCH ADVANCED SCANNERFeatherTouchfor gental, single scan treatmentsToeTouchfor common foot ailments, such as plantar warts and ingrown toenailsSilkTouchfor more vigorous, double scan treatmentsPaintfor controlled, continous freehand placement on small areasFineTouchfor precise ablation of irregular pigmented lesions at various depths125MM INCISIONAL HANDPIECEBlephfor precise, clean incisions with minimal bleeding.Exceptional Ablation/Coagulation Ratio
When ablation depth is equal, more energy means more excess heat in the tissue. SuperPulse technology enables the deepest penetration with the lowest energy. This reduces patient discomfort, downtime and thermal damages.LUMENIS ACUPULSE 120 CO2 also enables shorter pulses, further enhancing patient safety. |
Reviews
There are no reviews yet.