| Description | An easy-to-use diode laser with high efficacy and safety that delivers a positive ROI for growing aesthetics practices. Venus Epileve is fast, comfortable, and ensures coverage that is safe for all skin types, including tanned skin. | Includes 4 Handpieces:Erbium Yag 2940nm Handpiece for Laser Skin Resurfacing,Q-Switched Nd Yag 1064nm & 532nm Handpeice for Tattoo Removal,Diode 810nm Handpiece for Hair Removal,and IPL Handpiece for Skin Rejuvenation with 4 Filters: 650 nm of Hair Removal, 540 nm Filter for Skin Rejuvenation, 510 nm Filter for Vascular & Pigmented Lesions, and 450 nm Filter for Acne;Includes: 1 Full Day of Training, & 1 Year Manufacturer Warranty;Includes the following:1064 Nd Yag Tip, 532 KTP Tip, Tattoo Laser Goggles,2940 Erbium Yag Tip, Erbium Yag Goggles,4 IPL Filters including 650, 540, 510, and 450, IPL Goggles, | The Proven Power of Plasma for Skin Regeneration• Unique technology – controlled pulses of nitrogen plasma energy
• Treats the whole skin architecture – no islands of untreated skin remain
• Deep Tissue Remodelling – epidermis acts as natural dressing post treatment
• Versatile – high or low energy treatment choices to fit your patients’ needs and lifestyle
• Precise – treat eyelids effectively with significant results
• Long-lasting effects – intense fibroblast activity supports continued regeneration.
• Consistent – non-fractionated and non-chromophore dependence assures uniform energy absorption
• Proven Plasma Skin Regeneration is supported by numerous IRB-controlled studies
Technology | New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort. | The Dual Wavelength Solution that Delivers Suitable Parameters with an Incredible Fast Treatment SpeedLutronic CLARITY is a dual wavelength platform combining long pulsed 755 nm Alexandrite and 1064 nm Nd:YAG. CLARITY’s advanced features enable treatment versatility and greater speed. | Energist NeoGen PSR offers a range of treatment options, and delivers the unparalleled results your patients expect: The unique energy delivered by NeoGen is non fractionated and not dependant on a chromophore for its uptake. This provides uniform energy absorption, ensuring consistent treatment of the skin, and at high energies supporting significant tightening. |
| Content | Venus Epileve Laser Hair Removal Machine
More patients than ever are seeking comfortable, effective hair removal treatments. In fact, hair removal was one of the top five in-demand, minimally invasive cosmetic procedures in 2019. More than 1,055,000 people received hair removal treatment, and its popularity is likely to grow in the coming years1.Being able to respond to this demand is essential in order to stand out in a crowded industry. Fortunately, Venus Epileve is designed with operator ease and patient safety in mind at a cost that makes it an excellent choice for both new and growing practices.TECHNOLOGY Venus Epileve Laser Hair Removal MachineVenus Epileve is the cost-effective and easy-to-use tabletop diode laser device that will generate a positive ROI to aesthetic practices offering hair removal. Its unique technological features make it one of the easiest to use laser hair removal devices in the industry. Treatments are very comfortable, fast, and highly efficacious for all skin types.
HIGH EASE OF USE FOR THE OPERATOR- Work with a footswitch or an ergonomic applicator (designed for left- and right-hand use), whichever suits you best
- Pre-set parameters and an auditory guidance system, that standardizes the delivery of treatment by signaling you when to move, makes the results more predictable and consistent
- Venus Epileve™ is a tabletop device, this makes it easier to move it around on a standard trolley for increased mobility and efficiency
FAST AND VERSATILE TREATMENTS- Two modes of operation: PULSE and SLIDE mode
- PULSE delivers higher energy at a lower repetition rate, which leads to fewer treatment sessions
- SLIDE mode delivers a high repetition rate of short pulses, ensuring full treatment coverage with virtually no patient discomfort. The auditory guidance system included with this mode of treatment helps technicians deliver consistent and efficacious outcomes
REVOLUTIONARY COMFORT- Real-time cooling system monitors the applicator temperature frequently
- Maintains effectiveness, yet is virtually painless throughout the session, which boosts client compliance without impacting efficacy
- No downtime for cooling translates to higher productivity for your clinic
INTEGRATED IOT TECHNOLOGY- Internet of Things (IoT) is the latest technology to enhance business operations in many different industries
- Venus Epileve™ boasts unique IoT capability, helping to optimize everything from treatment protocols to results
- Usage data provided by IoT integration helps in device maintenance and ensuring treatment efficiency
| Sparkling Ellman Medley Multi-Platform Device 4 HPs Application: Laser skin resurfacing, skin ablation and coagulation, wrinkle and scar reduction Energy: Up to 1000 mJ Max Power: 2.4 W Pulse Width: 300 us Wavelength: 2940 nm Beam Divergence: Collimated Spot Size: 1.5 to 6 mm (with zoom lens) NOHD: >180 m Repetition Rate: up to 8 pulses per second Controls: Touch screen LCD, Footswitch Cooling: Self-Contained Closed Loop Q-Switched Nd Yag Handpiece Application: Nd Yag handpiece has two wavelengths of 1064 nm and 532 nm which are used for the treatment of vascular lesions including facial veins, telangiectasias, angiomas, hemangiomas, and pigmented lesions Energy: Up to 1000 mJ Maximum Fluence: 12 J/cm2 Wavelength: 1064 nm and 532 nm Spot Size: 1.5 to 4 mm (with zoom lens) Pulse Width: 10 to 15 ns Repetition Rate: 1 to 6 Hz NOHD: >1000 m Aiming Beam: Diode (635 nm, 10 mW Max.) Beam Delivery: Direct Controls: Touch screen LCD, Footswitch Cooling: Self-Contained Closed Loop 810 nm Diode Laser Handpiece Application: Laser Hair Removal Wavelength: 810 nm Spot Size: 10 x 14 mm Repetition Rate: 1-10 Hz Fluence: 1 to 100 J/cm2 NOHD: >30.1 m Pulse Width:Auto, 30 ms, 100 ms, 200 ms, 400 ms Accuracy: +- 10% Cooling Temperature: 0 to 5 C IPL Handpiece
Indicated Uses for 4 Filters:650 nm (HR) for Hair Removal540 nm (SR) Filter for Skin Rejuvenation510 nm (VR) Filter for Vascular & Pigmented Lesions, Melanin, Seborrheic Keratosis, & Photo Damaged Skin Lesions450 nm (AR) Filter for Acne & Atrophic Acne ScarsMaximum Fluence: 35 J/cm2 Wavelength: 450 to 1200 nm Spot Size: 35 x 15 mm Repetition Rate: 1 Pulse every 3 seconds Cooling: Self-Contained Closed Loop Indicated Uses:Sparkling Ellman Medley Multi-Platform Device 4 HPs - Tattoo Removal
- Pigmented Lesions on Skin Types -IV
- Active Acne
- Uneven Pigmentation
- Vascular Lesions
- Hair Removal
- Superficial Skin Resurfacing
- Fine Lines and Wrinkles
- Micro-Laser Peels
- Sun Damaged Skin
Ellman Medley Sparkling Multi-Platform Device 4 Handpieces SpecificationsErbium Yag Handpiece
Application:Laser skin resurfacing, skin ablation and coagulation, wrinkle and scar reduction
Energy:Up to 1000 mJ
Max Power:2.4 W
Pulse Width:300 us
Wavelength:2940 nm
Beam Divergence:Collimated
Spot Size:1.5 to 6 mm (with zoom lens)
NOHD:>180 m
Repetition Rate:up to 8 pulses per second
Controls:Touch screen LCD, Footswitch
Cooling:Self-Contained Closed Loop |
NeoGen PSR SystemNeoGen nitrogen plasma technology delivers controlled heating to the skin architecture stimulating a significant physiological response, without creating an open wound. Unlike ablative technologies there is no epidermal vaporisation or charring caused at time of treatment.
Unique TechnologyNeoGen converts nitrogen gas into plasma energy, the fourth state of matter. The plasma emerges from the handpiece in controlled pulses and rapid heating of tissue occurs as it gives up its unique thermal energy to tissue.
No Open WoundsThe treated photodamaged layers undergo a controlled thermal modification, while remaining intact, creating a natural dressing to provide protection and speed healing. at high energies the epidermis sheds, but only after a new, healthier skin architecture is formed beneath.
Treats the Whole Skin ArchitectureTreating the entire skin structure ensures optimal results as the entire surface is regenerated with associated neocollagenesis and neoelastogenesis. No islands of untreated skin remain. Clinical studies show significant tightening – Mean 22% improvement in upper eyelid tightening (JOCD 7, 169-179, 2008).
Eyelids and Periorbital TreatmentEnergist NeoGen PSR is the ideal option for the treatment of the upper and lower eyelids, as well as the wider periorbital region. Other technologies cannot be used in this area or deliver inconsistent results.
Long Lasting ResultsClinical studies show neocollagenesis and reduction in elastosis continuing for more than one year post treatment.The Proven Power of Plasma for Skin Regeneration• Unique technology – controlled pulses of nitrogen plasma energy
• Treats the whole skin architecture – no islands of untreated skin remain
• Deep Tissue Remodelling – epidermis acts as natural dressing post treatment
• Versatile – high or low energy treatment choices to fit your patients’ needs and lifestyle
• Precise – treat eyelids effectively with significant results
• Long-lasting effects – intense fibroblast activity supports continued regeneration.
• Consistent – non-fractionated and non-chromophore dependence assures uniform energy absorption
• Proven Plasma Skin Regeneration is supported by numerous IRB-controlled studies
TechnologyPlasma skin regeneration was introduced with a level of scientific and clinical testing never before seen in the industry:
• 3+ years of pre-clinical and clinical testing
• 16 separate studies
• more than 450 clinical study treatments –No scarring or Hypopigmentation noted in studies
• one year clinical histology
This level of testing is very rare in the industryEnergist NeoGen PSR uses a highly energized gaseous state known as plasma to produce a unique thermal profile to penetrate the superficial and deeper levels of the dermis to replace damaged collagen and encourage new collagen growth for new skin. Plasma is produced inside the handpiece through the combination of inert nitrogen gas and ultra-high frequency RF.The Energist NeoGen PSR is emitted in millisecond pulses; the longer the pulse, the more energy is delivered. Nitrogen molecules impact the skin’s surface and immediately transfer energy upon contact. When the nitrogen plasma impacts the skin surface, energy is immediately transferred to the tissue. Oxygen is purged from the skin surface by the plasma, preventing carbonisation. The energy delivered to tissue ranges from 1 – 4 Joules and is user-adjustable. The repetition rate of the plasma pulses can also be controlled, and ranges from 1 – 2.5 Hertz.Specifications PSR 2018 Energist NeoGen PSR| Power: | 100 – 120 / 230 Vrms – 50/60 Hz – 650 Va | | Energy Output: | Pulsed nitrogen plasma – 1-4 Joules. | | Repetition Rate: | 1.0 – 2.5Hz | | Dimensions: | 470 x 430 x 1060mm | | Gas Requirement: | Medical Grade Nitrogen | | System Weight: | 18kg/40lb | | Trolley Weight: | 25kg/55lb (excludes gas tank) | | Ambient Environment: | 0 to 40 celsius | | Relative Humidity: | 30 to 75% | | atmospheric pressure: | 700 to 1600 hpa |
| Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
The Laser uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IOptima-518-Classic Active Optical Systems Optima 518 IPL LaserThe Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. | Lutronic Clarity Long Pulsed Alexandrite & Nd:YAG LaserRESULTS YOU CAN SEEThe ability to choose from 755 nm or 1064 nm wavelength provides your clinic a highly versatile system. The CLARITY uses proven technology with advanced features to provide visible results in a single treatment.ALEX Toning
InnerLift Technique
Genesis Technique
Dual Fractional Technique
COCO TechniqueSale – Lutronic Clarity Long Pulsed Alexandrite & Nd:YAG Laser MULTIPLE TREATMENT OPTIONSAPPLICATIONS Lutronic Clarity Long Pulsed Alexandrite & Nd:YAG LaserHair removal
Skin tightening & firming
Skin rejuvenation
Large pores
Blackheads
Pigmented lesions
Epidermal pigments
Vascular lesions
Facial telangiectasia
Flushing
Rosacea
Leg veins
Warts
Onychomycosis
And more…Lutronic Clarity Long Pulsed Alexandrite & Nd:YAG Laser with Dual Fractional Feature
The Dual Wavelength Solution that Delivers Suitable Parameters with an Incredible Fast Treatment SpeedLutronic CLARITY is a dual wavelength platform combining long pulsed 755 nm Alexandrite and 1064 nm Nd:YAG. CLARITY’s advanced features enable treatment versatility and greater speed.
SPEEDSale – Lutronic Clarity Long Pulsed Alexandrite & Nd:YAG LaserA high repetition rate and large treatment spot empower CLARITY users to permanently reduce unwanted hair with unprecedented speed, allowing clinics to perform more treatments and maximise their return on investment.
EFFICACYCLARITY’s highly efficacious treatment options are rooted in the delivery of high peak power laser energy, in short pulse widths. The Flat Top beam profile provides consistent treatment for more predictable outcomes.
VERSATILITYCLARITY’s dual wavelengths permits the treatment of all skin types and its advanced features provide multi-treatment opportunities enabling clinics to treat a larger range of applications; physicians may permanently reduce unwanted hair, improve the appearance of pigmented and vascular lesions, and rejuvenate the skin with multiple treatment options.“The worldwide 1st dual fractional feature by one handpiece supports a more reliable and gentle procedure.”
CONVENIENCESingle fiber delivery with 9 spot size choices ranging up to 20 mm with both wavelengths for ease of use, increased treatment speeds and reduced costs across multiple applications
Choice of epidermal protection and comfort with built-in Intelligent Cooling Device™(ICD) or air coolingHYBRID COOLINGHybrid Cooling (Optional), available on ICD model, provides optional dual cooling for added patient comfort. | Energist NeoGen PSR LaserNeoGen PSR SystemNeoGen nitrogen plasma technology delivers controlled heating to the skin architecture stimulating a significant physiological response, without creating an open wound. Unlike ablative technologies there is no epidermal vaporisation or charring caused at time of treatment.
Unique TechnologyNeoGen converts nitrogen gas into plasma energy, the fourth state of matter. The plasma emerges from the handpiece in controlled pulses and rapid heating of tissue occurs as it gives up its unique thermal energy to tissue.
No Open WoundsThe treated photodamaged layers undergo a controlled thermal modification, while remaining intact, creating a natural dressing to provide protection and speed healing. at high energies the epidermis sheds, but only after a new, healthier skin architecture is formed beneath.
Treats the Whole Skin ArchitectureTreating the entire skin structure ensures optimal results as the entire surface is regenerated with associated neocollagenesis and neoelastogenesis. No islands of untreated skin remain. Clinical studies show significant tightening – Mean 22% improvement in upper eyelid tightening (JOCD 7, 169-179, 2008).
Eyelids and Periorbital TreatmentEnergist NeoGen PSR is the ideal option for the treatment of the upper and lower eyelids, as well as the wider periorbital region. Other technologies cannot be used in this area or deliver inconsistent results.
Long Lasting ResultsClinical studies show neocollagenesis and reduction in elastosis continuing for more than one year post treatment.The Proven Power of Plasma for Skin Regeneration Energist NeoGen PSR Laser• Unique technology – controlled pulses of nitrogen plasma energy
• Treats the whole skin architecture – no islands of untreated skin remain
• Deep Tissue Remodelling – epidermis acts as natural dressing post treatment
• Versatile – high or low energy treatment choices to fit your patients’ needs and lifestyle
• Precise – treat eyelids effectively with significant results
• Long-lasting effects – intense fibroblast activity supports continued regeneration.
• Consistent – non-fractionated and non-chromophore dependence assures uniform energy absorption
• Proven Plasma Skin Regeneration is supported by numerous IRB-controlled studies
TechnologyPlasma skin regeneration was introduced with a level of scientific and clinical testing never before seen in the industry:
• 3+ years of pre-clinical and clinical testing
• 16 separate studies
• more than 450 clinical study treatments –No scarring or Hypopigmentation noted in studies
• one year clinical histology
This level of testing is very rare in the industryEnergist NeoGen PSR uses a highly energized gaseous state known as plasma to produce a unique thermal profile to penetrate the superficial and deeper levels of the dermis to replace damaged collagen and encourage new collagen growth for new skin. Plasma is produced inside the handpiece through the combination of inert nitrogen gas and ultra-high frequency RF.The Energist NeoGen PSR is emitted in millisecond pulses; the longer the pulse, the more energy is delivered. Nitrogen molecules impact the skin’s surface and immediately transfer energy upon contact. When the nitrogen plasma impacts the skin surface, energy is immediately transferred to the tissue. Oxygen is purged from the skin surface by the plasma, preventing carbonisation. The energy delivered to tissue ranges from 1 – 4 Joules and is user-adjustable. The repetition rate of the plasma pulses can also be controlled, and ranges from 1 – 2.5 Hertz.Specifications Energist NeoGen PSR| Power: | 100 – 120 / 230 Vrms – 50/60 Hz – 650 Va | | Energy Output: | Pulsed nitrogen plasma – 1-4 Joules. | | Repetition Rate: | 1.0 – 2.5Hz | | Dimensions: | 470 x 430 x 1060mm | | Gas Requirement: | Medical Grade Nitrogen | | System Weight: | 18kg/40lb | | Trolley Weight: | 25kg/55lb (excludes gas tank) | | Ambient Environment: | 0 to 40 celsius | | Relative Humidity: | 30 to 75% | | atmospheric pressure: | 700 to 1600 hpa |
|
Reviews
There are no reviews yet.