| Description | An easy-to-use diode laser with high efficacy and safety that delivers a positive ROI for growing aesthetics practices. Venus Epileve is fast, comfortable, and ensures coverage that is safe for all skin types, including tanned skin. | Alma Soprano Titanium Laser Hair Removal Large 4cm2 spot size for quick treatment ICE PLUSTM continuous cooling system Two connectors Clinically proven 3D technology Intuitive, user friendly large screen (15′ android) with pre-set parameters. I-VI skin tones and tanned skin No consumables Treatments Soprano Titanium | Seperator Featuring its exclusive 3D technology, Soprano Titanium combines | The Extra – 818 is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features:
* Contemporary touch screen control
* Built-in Patch Test procedure for examining the optimal energy level
* A stunning number of 450,000 flashes in both lamps.
* The Large Handpiece has a Push Button in addition to the Foot Switch making
work easier and faster for the therapist. | Includes 4 Handpieces:Erbium Yag 2940nm Handpiece for Laser Skin Resurfacing,Q-Switched Nd Yag 1064nm & 532nm Handpeice for Tattoo Removal,Diode 810nm Handpiece for Hair Removal,and IPL Handpiece for Skin Rejuvenation with 4 Filters: 650 nm of Hair Removal, 540 nm Filter for Skin Rejuvenation, 510 nm Filter for Vascular & Pigmented Lesions, and 450 nm Filter for Acne;Includes: 1 Full Day of Training, & 1 Year Manufacturer Warranty;Includes the following:1064 Nd Yag Tip, 532 KTP Tip, Tattoo Laser Goggles,2940 Erbium Yag Tip, Erbium Yag Goggles,4 IPL Filters including 650, 540, 510, and 450, IPL Goggles, | Energist NeoGen PSR offers a range of treatment options, and delivers the unparalleled results your patients expect: The unique energy delivered by NeoGen is non fractionated and not dependant on a chromophore for its uptake. This provides uniform energy absorption, ensuring consistent treatment of the skin, and at high energies supporting significant tightening. | Laser Hair Removal
Details:- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
|
| Content | Venus Epileve Laser Hair Removal Machine
More patients than ever are seeking comfortable, effective hair removal treatments. In fact, hair removal was one of the top five in-demand, minimally invasive cosmetic procedures in 2019. More than 1,055,000 people received hair removal treatment, and its popularity is likely to grow in the coming years1.Being able to respond to this demand is essential in order to stand out in a crowded industry. Fortunately, Venus Epileve is designed with operator ease and patient safety in mind at a cost that makes it an excellent choice for both new and growing practices.TECHNOLOGY Venus Epileve Laser Hair Removal MachineVenus Epileve is the cost-effective and easy-to-use tabletop diode laser device that will generate a positive ROI to aesthetic practices offering hair removal. Its unique technological features make it one of the easiest to use laser hair removal devices in the industry. Treatments are very comfortable, fast, and highly efficacious for all skin types.
HIGH EASE OF USE FOR THE OPERATOR- Work with a footswitch or an ergonomic applicator (designed for left- and right-hand use), whichever suits you best
- Pre-set parameters and an auditory guidance system, that standardizes the delivery of treatment by signaling you when to move, makes the results more predictable and consistent
- Venus Epileve™ is a tabletop device, this makes it easier to move it around on a standard trolley for increased mobility and efficiency
FAST AND VERSATILE TREATMENTS- Two modes of operation: PULSE and SLIDE mode
- PULSE delivers higher energy at a lower repetition rate, which leads to fewer treatment sessions
- SLIDE mode delivers a high repetition rate of short pulses, ensuring full treatment coverage with virtually no patient discomfort. The auditory guidance system included with this mode of treatment helps technicians deliver consistent and efficacious outcomes
REVOLUTIONARY COMFORT- Real-time cooling system monitors the applicator temperature frequently
- Maintains effectiveness, yet is virtually painless throughout the session, which boosts client compliance without impacting efficacy
- No downtime for cooling translates to higher productivity for your clinic
INTEGRATED IOT TECHNOLOGY- Internet of Things (IoT) is the latest technology to enhance business operations in many different industries
- Venus Epileve™ boasts unique IoT capability, helping to optimize everything from treatment protocols to results
- Usage data provided by IoT integration helps in device maintenance and ensuring treatment efficiency
| Alma Soprano Titanium Laser Hair RemovalDIODE LASER ALEX 755NM
The Power of Diversity
Powerful absorption, combined with continuous cooling, treatment coverage, comfort and low maintenance, enables
the treatment of a wide range of hairtypes and colors, especially light colored and thin hair.SPEED 810
Up To Speed
Complete more treatment sessions in less time with this large spot size applicator.
Treat larger areas faster, while offering patients a safe and highly effective hair removal procedure.DIODE LASER YAG 1064
Dedicated to Darker Skin
The YAG 1064 uses a diode laser based on an ND: YAG wavelength, allowing for moderate energy absorption by the melanin chromophore, and is optimally suited for patients with darker skin tones.Large 4cm2 spot size for quick treatment
ICE PLUSTM continuous cooling system
Two connectors
Clinically proven 3D technology
Intuitive, user friendly large screen
(15′ android) with pre-set parameters.
I-VI skin tones and tanned skin
No consumables
TreatmentsAlma Soprano Titanium Laser Hair Removal | Seperator
Featuring its exclusive 3D technology, Soprano Titanium combines the three most effective laser wavelengths into a single applicator, simultaneously targeting different tissue depths and anatomical structures within the hair follicle. By combining the absorption and penetration levels of different wavelengths, along with extended treatment coverage, increased comfort and low maintenance requirements, Soprano Titanium is the safest and most efficient hair removal treatment available today.3D and 40% fasterThis exclusive applicator is a valuable asset for any clinic. With its large 4 cm2 spot size, and integration of three wavelengths, it facilitates increased treatment coverage to significantly reduce treatment time and make the process easier and more safe for patients. With TRIO4CM2, hair removal is quick, efficient and convenient.Trio
Three in OneThis applicator enables the delivery of three highly effective wavelengths in one.
Covering a spot size of 2cm2, it simultaneously targets different tissue depths and anatomical structures within the hair follicle, increasing treatment efficiency. | Active Optical Extra 818 IPL Skin Rejuvenation & Hair RemovalHandpieces:Integrated dual handpieces
Chilled Tip:Up to 4c
Pulse Interval:0.5-2 Seconds
Output Power:11-31 joulse/cm2, upto 4,000W
Cooling System:Revolutionary dual cooling
Control:Intuitive touch screen control
Lamp’s Life Span:250,000 Flashes (Universal) 200,000 Flashes (Facial)
Treatment Area:4.5 cm2 (15*50mm) Universal, 4.5 cm2 (15*30mm) Facial
Wavelength:420-100 nm
Weight:42Kg (including Stand)
Dimensions:44cm x 45cm x 100cmExtra-818 Active Optical Extra 818 IPL Skin Rejuvenation & Hair Removal
The Extra – 818 is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features:
* Contemporary touch screen control
* Built-in Patch Test procedure for examining the optimal energy level
* A stunning number of 450,000 flashes in both lamps.
* The Large Handpiece has a Push Button in addition to the Foot Switch making
work easier and faster for the therapist.The Extra – 818, based on Active’s GEM-PL technology, sets sets a specific Pulse Pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth.
The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.The combination of tested treatment protocols with high end engineering makes the Extra – 818 the perfect device for leading clinics.Revolutionary Cooling System
The Extra – 818 has a dual cooling system, controlled and monitored in order to ensure long lifetime to the lamp and a comfortable treatment to the patient.Competitive cooling systems “freeze” the skin so that during the treatment the skin temperature will rise to a bearable level. However, this “freezing” temperature might limit the results because the follicles will not reach the coagulation temperature. To ensure optimal results Active installed a special Processor that prevents overcooling the skin and maintains a uniform low temperature of the “glass” throughout the treatment. This revolutionary system enables the Extra – 818 to provide best results with optimal patient comfort.Research Program
For clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device.
The energy levels in the self setting program can reach 31Jcm2 with high intensity of 4,000W. | Sparkling Ellman Medley Multi-Platform Device 4 HPs Application: Laser skin resurfacing, skin ablation and coagulation, wrinkle and scar reduction Energy: Up to 1000 mJ Max Power: 2.4 W Pulse Width: 300 us Wavelength: 2940 nm Beam Divergence: Collimated Spot Size: 1.5 to 6 mm (with zoom lens) NOHD: >180 m Repetition Rate: up to 8 pulses per second Controls: Touch screen LCD, Footswitch Cooling: Self-Contained Closed Loop Q-Switched Nd Yag Handpiece Application: Nd Yag handpiece has two wavelengths of 1064 nm and 532 nm which are used for the treatment of vascular lesions including facial veins, telangiectasias, angiomas, hemangiomas, and pigmented lesions Energy: Up to 1000 mJ Maximum Fluence: 12 J/cm2 Wavelength: 1064 nm and 532 nm Spot Size: 1.5 to 4 mm (with zoom lens) Pulse Width: 10 to 15 ns Repetition Rate: 1 to 6 Hz NOHD: >1000 m Aiming Beam: Diode (635 nm, 10 mW Max.) Beam Delivery: Direct Controls: Touch screen LCD, Footswitch Cooling: Self-Contained Closed Loop 810 nm Diode Laser Handpiece Application: Laser Hair Removal Wavelength: 810 nm Spot Size: 10 x 14 mm Repetition Rate: 1-10 Hz Fluence: 1 to 100 J/cm2 NOHD: >30.1 m Pulse Width:Auto, 30 ms, 100 ms, 200 ms, 400 ms Accuracy: +- 10% Cooling Temperature: 0 to 5 C IPL Handpiece
Indicated Uses for 4 Filters:650 nm (HR) for Hair Removal540 nm (SR) Filter for Skin Rejuvenation510 nm (VR) Filter for Vascular & Pigmented Lesions, Melanin, Seborrheic Keratosis, & Photo Damaged Skin Lesions450 nm (AR) Filter for Acne & Atrophic Acne ScarsMaximum Fluence: 35 J/cm2 Wavelength: 450 to 1200 nm Spot Size: 35 x 15 mm Repetition Rate: 1 Pulse every 3 seconds Cooling: Self-Contained Closed Loop Indicated Uses:Sparkling Ellman Medley Multi-Platform Device 4 HPs - Tattoo Removal
- Pigmented Lesions on Skin Types -IV
- Active Acne
- Uneven Pigmentation
- Vascular Lesions
- Hair Removal
- Superficial Skin Resurfacing
- Fine Lines and Wrinkles
- Micro-Laser Peels
- Sun Damaged Skin
Ellman Medley Sparkling Multi-Platform Device 4 Handpieces SpecificationsErbium Yag Handpiece
Application:Laser skin resurfacing, skin ablation and coagulation, wrinkle and scar reduction
Energy:Up to 1000 mJ
Max Power:2.4 W
Pulse Width:300 us
Wavelength:2940 nm
Beam Divergence:Collimated
Spot Size:1.5 to 6 mm (with zoom lens)
NOHD:>180 m
Repetition Rate:up to 8 pulses per second
Controls:Touch screen LCD, Footswitch
Cooling:Self-Contained Closed Loop | Energist NeoGen PSR LaserNeoGen PSR SystemNeoGen nitrogen plasma technology delivers controlled heating to the skin architecture stimulating a significant physiological response, without creating an open wound. Unlike ablative technologies there is no epidermal vaporisation or charring caused at time of treatment.
Unique TechnologyNeoGen converts nitrogen gas into plasma energy, the fourth state of matter. The plasma emerges from the handpiece in controlled pulses and rapid heating of tissue occurs as it gives up its unique thermal energy to tissue.
No Open WoundsThe treated photodamaged layers undergo a controlled thermal modification, while remaining intact, creating a natural dressing to provide protection and speed healing. at high energies the epidermis sheds, but only after a new, healthier skin architecture is formed beneath.
Treats the Whole Skin ArchitectureTreating the entire skin structure ensures optimal results as the entire surface is regenerated with associated neocollagenesis and neoelastogenesis. No islands of untreated skin remain. Clinical studies show significant tightening – Mean 22% improvement in upper eyelid tightening (JOCD 7, 169-179, 2008).
Eyelids and Periorbital TreatmentEnergist NeoGen PSR is the ideal option for the treatment of the upper and lower eyelids, as well as the wider periorbital region. Other technologies cannot be used in this area or deliver inconsistent results.
Long Lasting ResultsClinical studies show neocollagenesis and reduction in elastosis continuing for more than one year post treatment.The Proven Power of Plasma for Skin Regeneration Energist NeoGen PSR Laser• Unique technology – controlled pulses of nitrogen plasma energy
• Treats the whole skin architecture – no islands of untreated skin remain
• Deep Tissue Remodelling – epidermis acts as natural dressing post treatment
• Versatile – high or low energy treatment choices to fit your patients’ needs and lifestyle
• Precise – treat eyelids effectively with significant results
• Long-lasting effects – intense fibroblast activity supports continued regeneration.
• Consistent – non-fractionated and non-chromophore dependence assures uniform energy absorption
• Proven Plasma Skin Regeneration is supported by numerous IRB-controlled studies
TechnologyPlasma skin regeneration was introduced with a level of scientific and clinical testing never before seen in the industry:
• 3+ years of pre-clinical and clinical testing
• 16 separate studies
• more than 450 clinical study treatments –No scarring or Hypopigmentation noted in studies
• one year clinical histology
This level of testing is very rare in the industryEnergist NeoGen PSR uses a highly energized gaseous state known as plasma to produce a unique thermal profile to penetrate the superficial and deeper levels of the dermis to replace damaged collagen and encourage new collagen growth for new skin. Plasma is produced inside the handpiece through the combination of inert nitrogen gas and ultra-high frequency RF.The Energist NeoGen PSR is emitted in millisecond pulses; the longer the pulse, the more energy is delivered. Nitrogen molecules impact the skin’s surface and immediately transfer energy upon contact. When the nitrogen plasma impacts the skin surface, energy is immediately transferred to the tissue. Oxygen is purged from the skin surface by the plasma, preventing carbonisation. The energy delivered to tissue ranges from 1 – 4 Joules and is user-adjustable. The repetition rate of the plasma pulses can also be controlled, and ranges from 1 – 2.5 Hertz.Specifications Energist NeoGen PSR| Power: | 100 – 120 / 230 Vrms – 50/60 Hz – 650 Va | | Energy Output: | Pulsed nitrogen plasma – 1-4 Joules. | | Repetition Rate: | 1.0 – 2.5Hz | | Dimensions: | 470 x 430 x 1060mm | | Gas Requirement: | Medical Grade Nitrogen | | System Weight: | 18kg/40lb | | Trolley Weight: | 25kg/55lb (excludes gas tank) | | Ambient Environment: | 0 to 40 celsius | | Relative Humidity: | 30 to 75% | | atmospheric pressure: | 700 to 1600 hpa |
| 2019 Lumenis Splendor X- Laser Hair Removal
Lumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthThe Lumenis Splendor X has been introduced to be a player in the solid state Nd:YAG and Alexandrite laser hair removal market. The gold standard for hair removal has always been considered Alexandrite 755nm for light skins and Nd:YAG 1064nm for dark skins.The Lumenis Splendor X combines both in a unique way with blended emission.Instead of firing a single wavelength at a time the Splendor X allows you to fire both wavelengths simultaneous in adjustable amounts to suit the skin type and hair types. This means you are target multiple chromophores at any given time given enhanced results across the board.The Lumenis Splendor X also allows the user to choose between square and round spot sizes with large spot sizesLumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthLaser Hair Removal
Details:2019 Lumenis Splendor X- Laser Hair Removal- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
|
Reviews