| Description | An easy-to-use diode laser with high efficacy and safety that delivers a positive ROI for growing aesthetics practices. Venus Epileve is fast, comfortable, and ensures coverage that is safe for all skin types, including tanned skin. | Laser Hair Removal
Details:- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| LOGIQ e Needle Recognition Software Option which helps provide precise and accurate display of the needle, anatomy and motion even in Color and Power Doppler. This feature harnesses pattern recognition technology that recognizes and accurately reveals the structure of a needle within the anatomy, without distortion of the needle and compromising the target. | New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort. | Includes 4 Handpieces:Erbium Yag 2940nm Handpiece for Laser Skin Resurfacing,Q-Switched Nd Yag 1064nm & 532nm Handpeice for Tattoo Removal,Diode 810nm Handpiece for Hair Removal,and IPL Handpiece for Skin Rejuvenation with 4 Filters: 650 nm of Hair Removal, 540 nm Filter for Skin Rejuvenation, 510 nm Filter for Vascular & Pigmented Lesions, and 450 nm Filter for Acne;Includes: 1 Full Day of Training, & 1 Year Manufacturer Warranty;Includes the following:1064 Nd Yag Tip, 532 KTP Tip, Tattoo Laser Goggles,2940 Erbium Yag Tip, Erbium Yag Goggles,4 IPL Filters including 650, 540, 510, and 450, IPL Goggles, | This technology sends a focused stream of cool air to the treatment area for added patient conformation during treatment,. Used In conjunction with Frax 1550 and Nd:YAg treatments.The Nordlys laser is equivalent to 6 stand alone devices in one. It allows you to grow with your business by adding applications as you go. With the Nordlys laser you have a great potential for return on investment with low running costs and fast treatment times. |
| Content | Venus Epileve Laser Hair Removal Machine
More patients than ever are seeking comfortable, effective hair removal treatments. In fact, hair removal was one of the top five in-demand, minimally invasive cosmetic procedures in 2019. More than 1,055,000 people received hair removal treatment, and its popularity is likely to grow in the coming years1.Being able to respond to this demand is essential in order to stand out in a crowded industry. Fortunately, Venus Epileve is designed with operator ease and patient safety in mind at a cost that makes it an excellent choice for both new and growing practices.TECHNOLOGY Venus Epileve Laser Hair Removal MachineVenus Epileve is the cost-effective and easy-to-use tabletop diode laser device that will generate a positive ROI to aesthetic practices offering hair removal. Its unique technological features make it one of the easiest to use laser hair removal devices in the industry. Treatments are very comfortable, fast, and highly efficacious for all skin types.
HIGH EASE OF USE FOR THE OPERATOR- Work with a footswitch or an ergonomic applicator (designed for left- and right-hand use), whichever suits you best
- Pre-set parameters and an auditory guidance system, that standardizes the delivery of treatment by signaling you when to move, makes the results more predictable and consistent
- Venus Epileve™ is a tabletop device, this makes it easier to move it around on a standard trolley for increased mobility and efficiency
FAST AND VERSATILE TREATMENTS- Two modes of operation: PULSE and SLIDE mode
- PULSE delivers higher energy at a lower repetition rate, which leads to fewer treatment sessions
- SLIDE mode delivers a high repetition rate of short pulses, ensuring full treatment coverage with virtually no patient discomfort. The auditory guidance system included with this mode of treatment helps technicians deliver consistent and efficacious outcomes
REVOLUTIONARY COMFORT- Real-time cooling system monitors the applicator temperature frequently
- Maintains effectiveness, yet is virtually painless throughout the session, which boosts client compliance without impacting efficacy
- No downtime for cooling translates to higher productivity for your clinic
INTEGRATED IOT TECHNOLOGY- Internet of Things (IoT) is the latest technology to enhance business operations in many different industries
- Venus Epileve™ boasts unique IoT capability, helping to optimize everything from treatment protocols to results
- Usage data provided by IoT integration helps in device maintenance and ensuring treatment efficiency
| 2019 Lumenis Splendor X- Laser Hair Removal
Lumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthThe Lumenis Splendor X has been introduced to be a player in the solid state Nd:YAG and Alexandrite laser hair removal market. The gold standard for hair removal has always been considered Alexandrite 755nm for light skins and Nd:YAG 1064nm for dark skins.The Lumenis Splendor X combines both in a unique way with blended emission.Instead of firing a single wavelength at a time the Splendor X allows you to fire both wavelengths simultaneous in adjustable amounts to suit the skin type and hair types. This means you are target multiple chromophores at any given time given enhanced results across the board.The Lumenis Splendor X also allows the user to choose between square and round spot sizes with large spot sizesLumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthLaser Hair Removal
Details:2019 Lumenis Splendor X- Laser Hair Removal- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| GE Logiq E R7 Portable Ultrasound Machine
The NextGen LOGIQ combines the high performance of a console system with the portability of a laptop. GE Healthcare’s compact system is designed for general imaging, musculoskeletal, anesthesiology, interventional, emergency, and critical care applications.It provides ultrasound imaging with precise anatomical detail at a variety of depths. The system includes innovative features that help simplify interventional procedures.LOGIQ e Needle Recognition Software Option which helps provide precise and accurate display of the needle, anatomy and motion even in Color and Power Doppler. This feature harnesses pattern recognition technology that recognizes and accurately reveals the structure of a needle within the anatomy, without distortion of the needle and compromising the target.Also includes the ability to adjust needle gain and angle.- Standard package includes AC power cord (USA)
- internet cord 3 meter in length CAT-5 type
- PC to HUB structure
- system software on USB
- Optional Function Key Label
- Ultrasound Transmission Gel .25L
- English Basic Service Manual CD and English User Guide and AIUM booklet.
The following scanning modes are included:- B-mode
- M-mode
- Anatomical M-mode
- Color flow mode
- Power Doppler imaging
- Pulsed wave Doppler and Ophthalmic
Features:The NextGen LOGIQ ecombines the high performance of a console system with the portability of a laptop. GE Healthcare’s compact system is designed for general imaging, musculoskeletal, anesthesiology, interventional, emergency, and critical care applications.Display Screen:- 15 in High-Resolution Color LCD
- Resolution: 1024 x 768
- Horizontal/Vertical viewing angle: +/-80 degree
- Brightness AdjustmentIntegrated Speakers
- Audio Volume Adjustment
- Interactive Dynamic Software Menu
Console Design:- Laptop Style
- Lithium Ion Battery
- Integrated Solid State Drive
- CPU – Intel Duo Core
- Operating System – Microsoft® Windows® 7
Console Interfaces:- DC Power Input
- USB 2.0 (3)
- LAN 10/100/1000 BaseT
- Docking Cart Connector
- HDMI
Standard Features:- Integrated Solid State Drive
- Automatic Optimization
- CrossXBeamTM
- Speckle Reduction Imaging (SRI-HD)
- Virtual Convex/Virtual Apex
- Fine Angle Steer
- HD Zoom (Write Zoom)
- Coded Harmonic Imaging (CHI)
- Raw Data Processing
- Quicksave
- On-board User Manual (Help)
- InSiteTM ExC capability
- Loop storage—from live scanning and from memory
- Patient Information Database
- Customizable User Interface
- Full M&A Calculation Package with Real Time Auto Doppler Calculations
- Vascular Calcs
- Cardiac Calcs
- OB Calcs and Tables
- Fetal Trending
- Multi Gestational Calcs
- Musculoskeletal and Hip Dysplasia Calcs
- Gynecological Calcs
- Urological Calcs
- Renal Calcs
- Small Parts Calcs
- Rheumatology Calcs
- Pediatric Calcs
- Report Writer Package
Software Options:- easy3D
- LOGIQ View
- Needle Recognition
- Stress Echo
- eSmart Trainer
- Auto IMT
- DICOM® 3.0 Connectivity/Encrypted DICOM
Specifications: Console Dimensions Height- 70 mm (2.75 in) console only
- 100 mm (3.94 in) with handle
Width- 295 mm (11.61 in) console only
- 343 mm (13.50 in) with handle
Length- 346 mm (13.62 in) console only
- 375mm (14.76 in) with handle
Weight with Battery: Approximately 5.2 Kg (11.5 lbs)Operator Keyboard- Alphanumeric Keyboard
- Ergonomic Hard Keys
- Backlight Keys
Display Screen- 15 in High-Resolution Color LCD
- Resolution: 1024 x 768
- Horizontal/Vertical viewing angle: +/-80 degree
- Brightness Adjustment
- Integrated Speakers
- Audio Volume Adjustment
- Interactive Dynamic Software Menu
Console Electrical Power- Voltage: 100-240 V AC
- Frequency: 50/60 Hz
- Power: Max. 130 VA
Applications:GE Logiq E R7 Portable Ultrasound Machine- Abdomen
- Cardiac
- Gynecology
- Musculoskeletal
- Obstetrical
- Nerve Block
- Pediatric
- Small Parts
- Urological
- Vascular
- Rheumatology
- Emergency Medicine
- Cardiac intra-operative
| Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
The Laser uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IOptima-518-Classic Active Optical Systems Optima 518 IPL LaserThe Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. | Sparkling Ellman Medley Multi-Platform Device 4 HPs Application: Laser skin resurfacing, skin ablation and coagulation, wrinkle and scar reduction Energy: Up to 1000 mJ Max Power: 2.4 W Pulse Width: 300 us Wavelength: 2940 nm Beam Divergence: Collimated Spot Size: 1.5 to 6 mm (with zoom lens) NOHD: >180 m Repetition Rate: up to 8 pulses per second Controls: Touch screen LCD, Footswitch Cooling: Self-Contained Closed Loop Q-Switched Nd Yag Handpiece Application: Nd Yag handpiece has two wavelengths of 1064 nm and 532 nm which are used for the treatment of vascular lesions including facial veins, telangiectasias, angiomas, hemangiomas, and pigmented lesions Energy: Up to 1000 mJ Maximum Fluence: 12 J/cm2 Wavelength: 1064 nm and 532 nm Spot Size: 1.5 to 4 mm (with zoom lens) Pulse Width: 10 to 15 ns Repetition Rate: 1 to 6 Hz NOHD: >1000 m Aiming Beam: Diode (635 nm, 10 mW Max.) Beam Delivery: Direct Controls: Touch screen LCD, Footswitch Cooling: Self-Contained Closed Loop 810 nm Diode Laser Handpiece Application: Laser Hair Removal Wavelength: 810 nm Spot Size: 10 x 14 mm Repetition Rate: 1-10 Hz Fluence: 1 to 100 J/cm2 NOHD: >30.1 m Pulse Width:Auto, 30 ms, 100 ms, 200 ms, 400 ms Accuracy: +- 10% Cooling Temperature: 0 to 5 C IPL Handpiece
Indicated Uses for 4 Filters:650 nm (HR) for Hair Removal540 nm (SR) Filter for Skin Rejuvenation510 nm (VR) Filter for Vascular & Pigmented Lesions, Melanin, Seborrheic Keratosis, & Photo Damaged Skin Lesions450 nm (AR) Filter for Acne & Atrophic Acne ScarsMaximum Fluence: 35 J/cm2 Wavelength: 450 to 1200 nm Spot Size: 35 x 15 mm Repetition Rate: 1 Pulse every 3 seconds Cooling: Self-Contained Closed Loop Indicated Uses:Sparkling Ellman Medley Multi-Platform Device 4 HPs - Tattoo Removal
- Pigmented Lesions on Skin Types -IV
- Active Acne
- Uneven Pigmentation
- Vascular Lesions
- Hair Removal
- Superficial Skin Resurfacing
- Fine Lines and Wrinkles
- Micro-Laser Peels
- Sun Damaged Skin
Ellman Medley Sparkling Multi-Platform Device 4 Handpieces SpecificationsErbium Yag Handpiece
Application:Laser skin resurfacing, skin ablation and coagulation, wrinkle and scar reduction
Energy:Up to 1000 mJ
Max Power:2.4 W
Pulse Width:300 us
Wavelength:2940 nm
Beam Divergence:Collimated
Spot Size:1.5 to 6 mm (with zoom lens)
NOHD:>180 m
Repetition Rate:up to 8 pulses per second
Controls:Touch screen LCD, Footswitch
Cooling:Self-Contained Closed Loop | Candela Ellipse Nordlys Laser Hair Removal
Ellipse IPLA fantastic IPL technology defined by patented dual filters as well as sub-millisecond pulses. All this adds up to exceptional photorejuvenation and vascular treatments as well as great results for hair removalFrax 1550This is no ablative fractional technology for the treatment of all types of scarring including acne and surgical. It is used for skin resurfacing treatments such as stretch marksNd:YAg 1064nmThe optimal laser wavelengths for the treatment of vascular lesions and dark skin hair removal.SoftCoolThis technology sends a focused stream of cool air to the treatment area for added patient conformation during treatment,. Used In conjunction with Frax 1550 and Nd:YAg treatments. Candela Nordlys LaserLightweight, easy to manoeuvre, arm
flexible cables to aid movement and ergonomics
Tray for keeping all accessories close to hand
Quiet operation mode
Remote service assistance
In-built patient database Candela Ellipse Nordlys Laser Hair RemovalCandela Nordlys LaserThe Nordlys laser was known originally as the ellipse Nordlys but now is been sold via Candela. It utilises 3 different foundations to be able to offer a wide range of treatment applications.The technologies found in the Candela/Ellipse Nordlys areEllipse IPL
Frax 1550 find our more about Frax
Nd:YAg 1054nmThe Nordlys laser is equivalent to 6 stand alone devices in one. It allows you to grow with your business by adding applications as you go. With the Nordlys laser you have a great potential for return on investment with low running costs and fast treatment times. This technology sends a focused stream of cool air to the treatment area for added patient conformation during treatment,. Used In conjunction with Frax 1550 and Nd:YAg treatments.The Nordlys laser is equivalent to 6 stand alone devices in one. It allows you to grow with your business by adding applications as you go. With the Nordlys laser you have a great potential for return on investment with low running costs and fast treatment times. |
Reviews