| Description | | This system allows not only a quantitative nutational infrasonic infiltration, but also a nutational infrasonic liposculpture.Manufactured for a safe liposculpture respecting the non-fatty tissues. | Energist NeoGen PSR offers a range of treatment options, and delivers the unparalleled results your patients expect: The unique energy delivered by NeoGen is non fractionated and not dependant on a chromophore for its uptake. This provides uniform energy absorption, ensuring consistent treatment of the skin, and at high energies supporting significant tightening. | Superior, Comfortable Laser Hair RemovalLaser Hair Removal – An In-demand Procedureexcel HR combines a high-power 755 nm Alexandrite laser and Cutera’s proven long-pulse 1064 nm Nd:YAG laser for safe, effective high-volume hair removal on all skin types. The combination of wavelengths not only allows for effective hair removal, but is also a solution for epidermal pigmented lesions, vascular lesions and Cutera’s signature laser genesis skin revitalization procedure. | Fotona XP Specto, Nd:YAG laser systemFotona’s new XP Spectro laser generator is the one of the latest models of Fotona to hit the market combining the industry recognised gold standard, long=pulse and quasi-continuous wave in a single multi-application laser generator. This combination of technology allows the client to integrate non-ablative aesthetics with surgical techniques. | The Extra – 818 is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features:
* Contemporary touch screen control
* Built-in Patch Test procedure for examining the optimal energy level
* A stunning number of 450,000 flashes in both lamps.
* The Large Handpiece has a Push Button in addition to the Foot Switch making
work easier and faster for the therapist. |
| Content | Syneron-Candela Vbeam Prima cosmetic laser
Our new VBeam Prima is particularly recommended for broken capillaries, rejuvenating skin with sun damage or photo ageing, rosacea, red scars and port wine stains.The Vbeam Prima is a highly efficient pulsed dye laser with dual wavelengths, dual cooling systems, giving a better and faster treatment experience overall. It has a number of indications for both face and body, including benign vascular and pigmented lesions, facial telangiectasia, and rosacea, and is a treatment with high patient tolerability and a low incidence of side effects.Rosacea is a common skin condition that is historically difficult to treat and can lead to redness, flushing and broken blood vessels, often in the central face. However, the VBeam Prima, with its 595 and 1064nm wavelengths, offers a complete treatment even for persistent rosacea with larger vessels affected.VBeam Prima Technology
Pulsed Dye Lasers deliver an intense but gentle burst of light into selectively targeted areas of the skin. The light is absorbed by specific blood vessels or melanin pigmented areas in the dermis. With its efficient cooling system and re-engineered hand piece, the VBeam Prima is the next generation pulse dyed laser.   Pictured above: Figures 1A, 2A & 4A – baseline before photos. Figues 1B, 2B & 4B were taken at the 2 month follow up post 4 treatments.What to expect
It is recommended to avoid sun exposure before and throughout treatment to maximize results. A sunblock of SPF 30 or higher should be worn daily during this time.At treatment time, your skin is firstly cleansed to remove any makeup, moisturising lotion and natural oils. The laser’s built-in cooling mechanisms will make the treatment more comfortable so there is no need for local anaesthetic. The epidermis of the skin is protected by the VBeam’s exclusive dynamic cooling method, DCD, which sprays a cooling mist onto the targeted area of skin before each laser pulse, maximising comfort and protecting the skin during treatment. As the laser pulses energy into the skin, you may feel a temporary warm or stinging sensation, which is very tolerable.There may be some redness or mild swelling in the treated area immediately following treatment, and this usually goes away in a few hours. Occasionally some minor bruising may occur, but this is transient and usually disappears in three to five days.Beneficial results are usually noted straight away, and often patients comment they feel a firming or tightening of the treated area. How long the results last will depend on many factors, including the condition being treated and the patient’s lifestyle. For example, if you have sunspots removed, and you continue to spend time in the sun without adequate skin protection, it is likely that the sunspots will return.Indications Syneron-Candela Vbeam Prima cosmetic laser
The VBeam Prima offers a platform capable of treating a wide range of indications, including:- acne scarring
- benign vascular lesions
- benign pigmented lesions
- benign cutaneous lesions
- inflammatory acne vulgaris
- facial telangiectasia
- deep blue veins
- venous lakes
- wrinkles
- rosacea
- photo ageing
| Euromi Eva SP7 Lipomatic Liposuction Unit{tab System composition}- 15-inch touch screen that can be angled from 0 to 45 degrees
- Excellent visibility for the surgeon during the procedure
- Control panel with touch screen allowing the infiltrated and aspirated zones to be visualized
- Control of the volume infiltrated and aspirated millimeter per millimeter in the zone selected on the touch screen
- The n.i.l technique ensures an homogeneous infiltration with a constant pressure, whatever the fat density
- Infiltration and aspiration data recording on USB flash memory
- Compatible with the lipofilling material n.l.f System 1 & 2
- In compliance with the European standards – CE marking
{tab Advantages}- Preservation of non-fatty tissues
- Very easy to change zones thanks to the mapping of the different zones on the touch screen
- Shorter post-procedure recovery
- Less traumatising (fewer hematomas and major reduction of ecchymosis and oedemas)
- Less painful for the patient
- Infrasonic frequency (25 Hz) comfortable for the patient
{tab Accessories} Euromi Eva SP7 Lipomatic Liposuction Unit- Evamatic/evamatic
- Control panel with touchscreen
- Quantitative infiltration system
- High-speed aspirator
- Complete set of cannulas
- Accessories
The Eva sp 7 allows a quantitative nutational infrasonic infiltration and also a nutational infrasonic liposculpture.Manufactured for a safe liposculpture respecting the non-fatty tissues, the system is entirely digitalizedIt complies with European standards (CE marking) and is compatible with N.L.F. System, our kit for lipofilling.This product is a medical device intended for use by qualified healthcare professionals.If you are a healthcare professional and would like more information about this product, please complete the form opposite.If you are an individual, for more information, please refer to your healthcare professional.Special features of Eva sp 7:- The screen provides excellent visibility for the surgeon during the procedure: infiltrated and aspirated areas.
- In addition, changing zones is very easy thanks to the mapping of the different zones on the touch screen. This screen allows you to control the volume infiltrated ml / ml in the zone selected on it.
- Infiltration and aspiration data can be saved on a USB drive.
| Energist NeoGen PSR LaserNeoGen PSR SystemNeoGen nitrogen plasma technology delivers controlled heating to the skin architecture stimulating a significant physiological response, without creating an open wound. Unlike ablative technologies there is no epidermal vaporisation or charring caused at time of treatment.
Unique TechnologyNeoGen converts nitrogen gas into plasma energy, the fourth state of matter. The plasma emerges from the handpiece in controlled pulses and rapid heating of tissue occurs as it gives up its unique thermal energy to tissue.
No Open WoundsThe treated photodamaged layers undergo a controlled thermal modification, while remaining intact, creating a natural dressing to provide protection and speed healing. at high energies the epidermis sheds, but only after a new, healthier skin architecture is formed beneath.
Treats the Whole Skin ArchitectureTreating the entire skin structure ensures optimal results as the entire surface is regenerated with associated neocollagenesis and neoelastogenesis. No islands of untreated skin remain. Clinical studies show significant tightening – Mean 22% improvement in upper eyelid tightening (JOCD 7, 169-179, 2008).
Eyelids and Periorbital TreatmentEnergist NeoGen PSR is the ideal option for the treatment of the upper and lower eyelids, as well as the wider periorbital region. Other technologies cannot be used in this area or deliver inconsistent results.
Long Lasting ResultsClinical studies show neocollagenesis and reduction in elastosis continuing for more than one year post treatment.The Proven Power of Plasma for Skin Regeneration Energist NeoGen PSR Laser• Unique technology – controlled pulses of nitrogen plasma energy
• Treats the whole skin architecture – no islands of untreated skin remain
• Deep Tissue Remodelling – epidermis acts as natural dressing post treatment
• Versatile – high or low energy treatment choices to fit your patients’ needs and lifestyle
• Precise – treat eyelids effectively with significant results
• Long-lasting effects – intense fibroblast activity supports continued regeneration.
• Consistent – non-fractionated and non-chromophore dependence assures uniform energy absorption
• Proven Plasma Skin Regeneration is supported by numerous IRB-controlled studies
TechnologyPlasma skin regeneration was introduced with a level of scientific and clinical testing never before seen in the industry:
• 3+ years of pre-clinical and clinical testing
• 16 separate studies
• more than 450 clinical study treatments –No scarring or Hypopigmentation noted in studies
• one year clinical histology
This level of testing is very rare in the industryEnergist NeoGen PSR uses a highly energized gaseous state known as plasma to produce a unique thermal profile to penetrate the superficial and deeper levels of the dermis to replace damaged collagen and encourage new collagen growth for new skin. Plasma is produced inside the handpiece through the combination of inert nitrogen gas and ultra-high frequency RF.The Energist NeoGen PSR is emitted in millisecond pulses; the longer the pulse, the more energy is delivered. Nitrogen molecules impact the skin’s surface and immediately transfer energy upon contact. When the nitrogen plasma impacts the skin surface, energy is immediately transferred to the tissue. Oxygen is purged from the skin surface by the plasma, preventing carbonisation. The energy delivered to tissue ranges from 1 – 4 Joules and is user-adjustable. The repetition rate of the plasma pulses can also be controlled, and ranges from 1 – 2.5 Hertz.Specifications Energist NeoGen PSR| Power: | 100 – 120 / 230 Vrms – 50/60 Hz – 650 Va | | Energy Output: | Pulsed nitrogen plasma – 1-4 Joules. | | Repetition Rate: | 1.0 – 2.5Hz | | Dimensions: | 470 x 430 x 1060mm | | Gas Requirement: | Medical Grade Nitrogen | | System Weight: | 18kg/40lb | | Trolley Weight: | 25kg/55lb (excludes gas tank) | | Ambient Environment: | 0 to 40 celsius | | Relative Humidity: | 30 to 75% | | atmospheric pressure: | 700 to 1600 hpa |
| Cutera Excel HR 1064 755 Hair Removal SystemAlexandrite
Wavelength:755 nm
Maximum Energy:53J
Pulse Duration:3 ms
Spot Size:5-18 mm
Repetition Rate:2 HzNd Yag
Wavelength:1064 nm
Maximum Energy:80J
Pulse Duration:0.1 – 300 ms
Spot Size:3-12 mm
Repetition Rate:Up to 10 Hz
Cooling:Contact Sapphire
Aiming Beam:635 nm
Dimensions:35″ H x 12″ W x 24″ D
Electricial:200-240 VAC, 50/60 Hz, 20A/30ACooling:Contact Sapphire
Aiming Beam:635 nm
Dimensions:35″ H x 12″ W x 24″ D
Electricial:200-240 VAC, 50/60 Hz, 20A/30A
Superior, Comfortable Laser Hair Removal
Laser Hair Removal An In-demand Procedure
Global hair removal procedures are growing at a rapid pace. Laser hair removal has been among the top non-surgical procedures according to the American Society of Aesthetic Plastic Surgery and procedure revenue is anticipated to go to $1.35B by 20221. The industry often refers to laser hair removal as a gateway procedure as it offers an entry point into the aesthetic market for patients and practitioners alike.excel HR combines a high-power 755 nm Alexandrite laser and Cuteras proven long-pulse 1064 nm Nd:YAG laser for safe, effective high-volume hair removal on all skin types. The combination of wavelengths not only allows for effective hair removal, but is also a solution for epidermal pigmented lesions, vascular lesions and Cuteras signature laser genesis skin revitalization procedure.excel HR Technology
Proven Wavelengths
excel HR combines the gold standard laser wavelengths for hair removal. The 755 nm Alexandrite laser is highly absorbed by melanin making it an ideal solution for finer hair on skin types I-III. Because of the high melanin absorption characteristics, it has also been proven to provide long-term results on epidermal pigmented lesions.The 1064 nm Nd:YAG is the safest wavelength for permanent hair reduction on darker skin types and tanned skin. By selecting the appropriate spot size, this laser can also be used for treating facial and leg veins and perform laser genesis procedure.truPulse Delivery with Index Matching
Unique to Cutera, the truPulse technology delivers constant, sustained energy throughout the pulse duration to ensure consistent performance and proven clinical outcomes for your patients.excel HRs index matching delivery results in more efficient coupling of laser energy to target structures. Index matching allows backscattered light to escape, further protecting the epidermis from heat build-up while maintaining treatment efficacy.Superior Contact Cooling
excel HR utilizes sapphire contact cooling to provide continuous cooling, maximizing your patients comfort and treatment safety.2 In a patient preference study that measured comfort and satisfaction for laser hair removal, 100% of the patients preferred excel HR over a comparable, competitive laser hair removal procedure.321st Century Laser Hair Removal System
Developed by the innovative leader in aesthetic laser technology, excel HR laser hair removal system provides advanced premium hair removal solutions for every skin type. Combining a new high-power 755 nm Alexandrite laser, and CUTERAs proven long-pulse 1064 nm Nd:YAG laser, coupled with the superiority of sapphire contact cooling, excel HR redefines modern laser hair removal.This makes excel HR laser system an effective, safe and comfortable option for laser hair removal for the 21st century.Applications Cutera Excel HR 1064 755 Hair Removal System
– Hair removal
– Benign pigmented lesion removal
– Veins, facial
– Veins, leg
– Laser Genesis | Fotona XP Spectro Laser GeneratorThe Fotona XP Spectro laser offers an industry leading number of treatments from its advanced platform. The Fotona XP Spectro is an ideal choice for new clinics and clinics wishing to advance to a Fotona laser system from their current equipment.Not looking for a new Laser? See our Used-Laser Sales DirectoryThe Fotona XP Spectro laser offers high quality, fast, efficient treatments in the fields of aesthetics and surgery without compromising efficacy.The Fotona XP Spectro laser system has a 35 watt Nd:YAG engine offering different pulse configurations to be able to offer a wide range of applications at no extra cost and no need for additional hand pieces of software.Non-ablative Nd:YAG lasers are a extremely popular choice of laser in an extremely lucrative marketplace. Nd:YAG is proven as a gold standard in hair removal, skin rejuvenation, vascular treatments and much more. Fotona Xp Spectro Nd:YAG laser emits laser energy at 106nm which is proven to minimize discomfort while showing exceptional efficiently and long term results Features:Fotona XP Spectro Laser Generator
* Highest Performance
* Gold standard ND:YAG lasers
* Optional QCW Nd:YG laser
* Multiple applications
* Advanced scanner for greater Precision, Speed and Efficacy
* FRAC3 modality
* User friendly
* Massive earning potential
* Ability to treat all skin types safely and effectively Key Treatments:
* Laser Hair removal
* Rosacea treatments
* Fine wines and Wrinkles
* Laser peels
* Acne treatments
* Laser assisted lipolysis
* Laser assisted Hyperhidrosis
* Onychomycosis
* Skin tightening, tonng and texturing
* Endovenous laser
* Vascular legions
* Thread veins
* FRAC3
* Pigmentation
* Verrucae Technical Data:
* Laser wavelength:1064 nm
* Max. average power:35 W
* Pulsewidth range:PULSE: 0.1 to 50 ms, QCW: 0.1 to 2 ms
* Max. frequency:PULSE: 75 Hz, QCW*: 100 Hz
* Manual spotsizes:2 to 10 mm
* Scanner spotsizes:3 mm*, 6 mm, 9 mm*
* Scanner area:42 cm²
* Beam delivery type:Optical fiber Comes with:
* 5 Years Full Parts and Labour Warranty
* 3 pairs of laser safety goggles
* Standard Nd:YAG hanpiece (R33)
* Training and ongoing support
* Competative rates for clinic consumables | Active Optical Extra 818 IPL Skin Rejuvenation & Hair RemovalHandpieces:Integrated dual handpieces
Chilled Tip:Up to 4c
Pulse Interval:0.5-2 Seconds
Output Power:11-31 joulse/cm2, upto 4,000W
Cooling System:Revolutionary dual cooling
Control:Intuitive touch screen control
Lamp’s Life Span:250,000 Flashes (Universal) 200,000 Flashes (Facial)
Treatment Area:4.5 cm2 (15*50mm) Universal, 4.5 cm2 (15*30mm) Facial
Wavelength:420-100 nm
Weight:42Kg (including Stand)
Dimensions:44cm x 45cm x 100cmExtra-818 Active Optical Extra 818 IPL Skin Rejuvenation & Hair Removal
The Extra – 818 is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features:
* Contemporary touch screen control
* Built-in Patch Test procedure for examining the optimal energy level
* A stunning number of 450,000 flashes in both lamps.
* The Large Handpiece has a Push Button in addition to the Foot Switch making
work easier and faster for the therapist.The Extra – 818, based on Active’s GEM-PL technology, sets sets a specific Pulse Pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth.
The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.The combination of tested treatment protocols with high end engineering makes the Extra – 818 the perfect device for leading clinics.Revolutionary Cooling System
The Extra – 818 has a dual cooling system, controlled and monitored in order to ensure long lifetime to the lamp and a comfortable treatment to the patient.Competitive cooling systems “freeze” the skin so that during the treatment the skin temperature will rise to a bearable level. However, this “freezing” temperature might limit the results because the follicles will not reach the coagulation temperature. To ensure optimal results Active installed a special Processor that prevents overcooling the skin and maintains a uniform low temperature of the “glass” throughout the treatment. This revolutionary system enables the Extra – 818 to provide best results with optimal patient comfort.Research Program
For clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device.
The energy levels in the self setting program can reach 31Jcm2 with high intensity of 4,000W. |
Reviews
There are no reviews yet.