Laser Type:CO2
Wavelength:10,600nm
Laser Emission Mode:Pulsed
Output Power:60 watts (maximum peak)
Laser Beam Energy:Variable from 1 – 90 mJ
Pulse Repetition Rate:Up to 16.7 kHz
Pulse Duration:20 – 3000 usec
Power Stability:± 1.5 watts (±5%)
Mode Quality:(M²) < 1.2
Beam Size:Ø 1.8 ± 0.5 mm
Beam Divergence:7.5 ± 0.5 mrad (full angle)
Polarization:> 100:1 linear (orthogonal to mounting pads)
Maximum Scan Area:10 mm diameter
Aiming Laser:5 mW, 650 nm (red) diode laser
Articulated Arm:Lightweight, aluminum fiber, 7-joint, pneumatically balanced
Treatment radius at full arm extension:85 cm (33.5″)
Horizontal rotation:360°
Lens Assemblies:150 um spot size, 120 um spot size:(optional)
Handpiece:Multi-use Aesthetic or surgical hand piece
User Interface:10.4″ high-resolution
Laser Emission Control:Footswitch
Laser Emission Indicators:Solid amber LED in Standby and Ready modes
Flashing:red LED during laser emission
Electrical Requirements:100 – 240 VAC self-sensing, 50/60 Hz, 7.1 A, single phase
Dimensions:40 cm x 44 cm x 177 cm, (15.75″ x 17.3″ x 70″)
Weight:26 kg (58 lbs)
Operating Modes
Mode:[ Energy Settings ] [ Fractional Coverage ] [ Estimated Ablation Depth ]
CO2RE Light:[18 – 74.5 mJ] [30 – 50%] [20 – 40 um]
CO2RE Mid:[45 – 257 mJ] [20 – 40%] [100 – 200 um]
CO2RE Deep:[30 – 70 mJ] [1 – 5%] [500 – 750 um]
CO2RE Fusion:[45 – 128 mJ, 30 – 70 mJ] [20 – 40%] [100 – 200 μm & 500 – 750 um]
Classic Resurfacing:[1 – 10 mJ] [Full] [100 – 200 um]
Dermal Excision:[5 – 40 mJ] [N/A] [0.2 mm x selected line 0.2 mm freehand]First fully integrated CO2 laser, worldwide.
Designed to adapt to your patients needs, with 100+ indications.What CO2RE Is For100+ indications cleared in 10 medical specialties, including dermatology, plastic surgery, and gynecology.Imagine having one system designed for numerous procedures that require excision, incision, ablation, coagulation, and resurfacing of soft tissue. Its here. With the CO2RE system, you can precisely target and efficiently treat the skin with control.Treat multiple skin layers in one pass
Perform full and fractional resurfacing
Enhance coagulation
Encourage neocollagenisIndustry-first internal scanner optimized for numerous individualized treatment applicationsKey Benefits of the CO2RE System
Give your patients positive experiences and outcomes.
CO2RE treatments are fast and require limited downtime.The system delivers proven, predictable, visible results across indications1-4, including:Enhancing skin tone and texture through skin resurfacingReducing the effects of the sun and aging on the skinSmoothing out fine lines, wrinkles, and surgical and acne scarsGain unparalleled treatment flexibility that can help your practice grow.
Designed from the inside out to be a comprehensive work station:
CO2RE Aesthetics for skin resurfacing, from superficial to deep skin treatments, including several options and combinations tailored for your patients needs.
CO2RE Surgical for a true, continuous wave with efficient skin coagulation after the surgical cut.
CO2RE® Intima for gynecology applications, enabling you to broaden your portfolio offering.CO2RE Product FeaturesLightLight Peel
20-40 µm
Level with Stratum ComeumMidEpidermal and dermal resurfacing
Coagulation
100-200 µm
Improve skin tone and texture
Complexion refresherDeepDeep fractional resurfacing
Deeper level coagulation
500-700 µm
Improve scars, fine lines and wrinklesFusion Syneron Candela CO2RE Intima LaserCombination of superficial and deep fractional resurfacing
Superficial texture variations
Fine lines and wrinklesWhat CO2RE Intima is For
The CO2RE® Intima system is uniquely engineered to transform treatment of many dermatological conditions, including gynecological needs.
The CO2RE Intimas comprehensive range of treatment options1 include:Using well-established CO2 technology, you can now perform minimally invasive, non-hormonal, energy-based treatments of the introitus, vaginal canal, and external genitalia in your office, in as little as 10 minutes for each treatment.Ablation and resurfacing of soft tissue
Scar tissue (e.g. C-section scar)
Conization of the cervix such as vulvar and vaginal intraepithelial neoplasia (VIN, VAIN)
Leukoplakia (vulvar dystrophies)
Condyloma acuminateThe systems customized handpieces are designed to treat the introitus, vaginal canal, and external genitalia.
Conveniently treat with pre-set or individualized treatment options
Accurately target and treat tissue with ergonomic, pen-like precision2
With 360o rotation capability for ease of use on tissue along the vaginal canal, and sterile for every patient, the single-use handpieces are guaranteed ready to use.Significant benefits for your practice and patients.
Efficient procedural time as little as 10 minutes for each treatment
Minimally invasive, non-hormonal, energy-based treatment
Portable system allows you to easily perform office-based procedures, and is easy to move from room to room
Simple in-office setup for gynecological applications
Single-use handpiece optimizes workflow, enhancing patient safety
Financial savings single-use handpieces reduce staff time, administrative costs, and inefficienciesDesigned with your practice in mind.
The CO2RE Intima system offers numerous user-friendly, productivity-enhancing features.Minimize physician fatigue with articulated arm and featherweight handpieces
Gynecology-specific selection of handpieces and lenses
Intuitive touch-screen interface stores and recalls user preferences
Precision internal scanner digitally synchronized with laser pulse generator
Compact, quiet, easily mobile, and portableWell-established CO2 technology treats skin or soft tissue.
CO2 technology has been used in gynecology for benign and pre-malignant vulvar and cervical dysplasia since 1973.The CO2RE system offers customizable treatment capability with handpiece and lens combinations to provide physician control. Compared to traditional surgical methods, it provides greater precision, cleaner incision, and less scarring. | LUTRONIC ECO2 – ABLATIVE CO2 FRACTIONAL LASERLaser Type:Ablative Fractional Resurfacing (AFR)
Beam Delivery Method:Articulated Arm with Scanner or Convetional Handpiece
Medium & Method of Generation:Seall Off CO2 RF Mudule Laser
Wavelength:10,600 nm
CO2 RF Module Maximum Power: Maximum 30 Watt at Continuous Wave
Fractional Scanner Handpiece:
User Mode:Static (Stamping) / Dynamic (Air Brushing)
Tip:120, 300, 1000 um Spot Sizes
Pulse Energy:2 mJ – 240 mJ
Pulse Rate:10Hz to 200 Hz
Density:25 – 400 Spots / cm2
Scan Area:Max.14 x 14 mm
Scan Shapes:Square, Rectangle, Oval, Triangle, Point Beam
Normal Handpiece:
User Mode:Char Free (Ultra Pulse) / Super Pulse / CW
Pulse Rate:Char Free (Ultra Pulse) – 1 Hz to 700 Hz; Super Pulse – 1 Hz – 550 Hz
Pulse Width:Char Free (Ultra Pulse) – 40 us to 1000 us; Super Pulse – 1 ms – 5 ms
CW:ON Time – Cont. 0.01 s – 1.0 s
CW:OFF Time – SINGLE 0.001 s – 1.0 s
Adjustable Spot Size:0.2 – 1.0 mm
User Interface:Touch Screen with Flash Technology 7 inch LCD Screen
Dimensions EXCLUDES ARM: 360 mm (W) x 450 mm (L) x 1000 mm (H)
Dimensions WITH ARM: 360 mm (W) x 450 mm (L) x 1870 mm (H)
Weight:77 lbs. (35 kg)
Cooling:Air Cooling
Transform Your Practice with the Robust eCO2
Lutronics eCO2 is the premier fractional ablative laser that delivers the full spectrum of resurfacing treatments to your busy practice. You will appreciate how easy to use and reliable the system is while your patients rave about their outcomes.Includes:
1x Fractional Scanner Handpiece
4x Brand New 120 Tips
2x Brand New 300 Tip
1x 1000 Tip
Footswitch
2 Keys
Operator Manual
1 Operator Eyewear
1 Patient EyewearMINIMAL DOWNTIME & LESS DISCOMFORT
– Skin Tightening
– Wrinkles, Rhytids & Fine Lines
– Pigmented Lesions & Lentigines
– Scars
– Textural Irregularities
– Transepidermal Drug Delivery
– Dyschromia
– Solar/Actinic Elastosis
– Syringoma
– Vaporization, Incision & Excision CapabilitiesMINIMAL DOWNTIME, IMPROVED PATIENT COMFORT, INCREASED SAFETYThe Lutronic eCo2 – Ablative Co2 Fractional Laser features the patented Controlled Chaos Technology (CCT), an algorithm to pseudo-randomly deliver each micro laser beam and by placing maximum distance between sequential beams the system eliminates cross thermal diffusion between adjacent Micro-ablative Columns (MACs).This allows the tissue to maximize heat dissipation between shots. The result is an increased safety profile with a reduction in post-operative discomfort and faster healing time leading to unparalleled fractionalCCT reduces thermal damage by maximizing distance between laser micro-beamsQUICK-CHANGE TIPS WITH AUTO-RECOGNITIONFrom ultra-deep to superficial ablation, the eCO2 has the features you need to address a broad range of clinical conditions. The ultra-fast quick change tips come in a choice of three spot sizes, 120, 300 and 500 um, allowing you on-the-fly customized treatments. The eCO2s tip auto-recognition feature automatically changes treatment settings to adjust for the change in spot size. Combined together, the advanced technology, quick-change tips and safety features ensure the ultimate control for the best outcomes.WHY eCO2
Patients are attracted to low risk, minimal downtime treatments
Controlled Chaos Technology creates pseudo-random microwound patterns to minimize heat build-up, minimize downtime, increase safety and maximize patient comfort | 2015 Lutronic LaseMD Pro Fractional Skin Wrinkles
Lutronic LaseMD Ultra Laser is an impressive upgrade to their already successful LaseMD,” shared Steven Weiner, MD, from Lutronic.“Not only is it more powerful (20 watts vs 12 watts) but it also has a significantly lower consumable cost than competitive systems. The LaseMD ULTRA offers a new larger spot size and incorporates improved ‘top hat’ beam profile. The system also offers an incredibly advanced graphical user interface.“The integration of all the new features with real-time information helps reduce treatment time and achieve satisfying patient results in fewer treatments. Since no anesthesia is required, I can treat a full face in about 6-8 minutes or treat the face, neck and chest in 20 minutes.”Lutronic LaseMD Ultra Laser is yet another example of Lutronic’s commitment to Intelligent Design for Intelligent Care, according to the company in a media release. Features include:Highest available power allows for fast treatments, customizable for multiple areas
Gentle, effective global improvement for all skin types, all year-round
Comfortable treatments with very little downtime
Minimal cost of ownership, easy to delegate and no shot limit per procedure“LaseMD ULTRA is my favorite new addition to my practice. It allows me to treat multiple areas quickly, effectively and for very low cost,” adds Joel Cohen, MD, in the release. “My patients love the comfortable treatments and impressive results with minimal downtime.”The LaseMD ULTRA a high-power platform which provides a full range of applications in all skin types, including:Age spots (lentigos),
Sunspots (solar lentigos),
Freckles (ephilides),
Actinic Keratoses, and
Treatment of other benign pigmented lesions.Fractional Skin ResurfacingWrinkles - Laxity - Scar Reduction - Pigmentation - Melasma - Anti-Aging - Actinic Keratosis Excellent, Pre-Owned Condition
Serviced and Fully TestedMfr: Lutronic
Model: LaseMD PRO
S/N: LS115D047PS
Mfr Date: 06-19-2015LaseMDAdvanced skin resurfacing laser featuring the Thulium 1927nm wavelength, which focuses on coagulation rather than ablation.Suitable for all skin types.Cosmeceutical Delivery SystemLaseMD creates micro-channels in the skin to specific depths to delivery topical serums to the correct layer of the skin and increase absorption. It also features a built in centrifuge/incubator for LaseMD serum Ampoules.Optimized Magnetic Sensor Tracking Scanner Includes: 2015 Lutronic LaseMD Pro Fractional Skin Wrinkles
- LaseMD Workstation with Scanning Handpiece
- LaseMD Rolling Cart
- 2 Handpiece Caps
- FootSwitch Pedal
- System Key
- Power CableSpecifications:
Laser Type: Thulium
Wavelength: 1927nm | Deka Synchro Replay Laser Nd-Yag Inside Moveo Innovation Moveo HR: Focus on Hair Removal
The multiple passes of Moveo HR over small defined areas cause gradual heating and destruction of unwanted hairs.
Moveo PL: Focus on Pigmented Lesions
The new MOVEO PL is indicated for skin age and sun spots progressively heating the pigmentedMoveo SR: Focus on Skin Rejuvenation
The multipass controlled action of MOVEO SR causes a progressive increase in heat at the dermal level, which stimulates a neocollagenic process.Moveo VL: Focus on Vascular Lesions
The specific action of Moveo VL acts directly and effectively on vascular redness.The versatile FT lamp can be added to the system at any time, enhancing the user’s ability to treat superficial Vascular and Pigmented Lesions.The FT pulsed light has ten different filters divided in five spectra of emission (500-520-550-600-650nm) and two spot areas. This flexibility is useful to adapt the emitted light to the patient skin type, application and treatment area.Deka Synchro Replay Laser Nd-Yag Standard Handpieces – More than 10 selectable handpieces
– Different spotsizes available (2.5 – 24 mm)– Automatic spot recognition system– Ergonomic connector for air-cooling devicesDeka Synchro Replay Laser Nd-Yag
Wavelength: 1064 nm
Pulse Energy: 120 J (max)
Pulse Lenght: 0.2 ms to 300 ms
Frequency Single Pulse: 10Hz (max)
Spot Diameter: 20mm, 15mm, 10mm, 7mm, 5mm, 2.5mm
Emission Spectrum: 500-950 nm and 650-950 nmTo Include:
1 x Foot Switch
1 x Key
1 x Module UPL Handpiece
6 x Deka Laser Handpieces
1 x ManualInside Moveo InnovationMoveo HR: Focus on Hair Removal
The multiple passes of Moveo HR over small defined areas cause gradual heating and destruction of unwanted hairs.
Moveo PL: Focus on Pigmented Lesions
The new MOVEO PL is indicated for skin age and sun spots progressively heating the pigmented lesions.Moveo SR: Focus on Skin Rejuvenation
The multipass controlled action of MOVEO SR causes a progressive increase in heat at the dermal level, which stimulates a neocollagenic process.Moveo VL: Focus on Vascular Lesions
The specific action of Moveo VL acts directly and effectively on vascular redness. | 2018 Lutronic Infini RF Microneedling Skin Tightening System Type: Bipolar RF (Radiofrequency) Frequency: 1 MHz Total RF Treatment Level: Up to Level 20 (Max. Power 50 W) Operation Mode:Microneedle Fractional RF (MFR) Treatment Duration:10 ms – 1,000 ms Tips: MFR Microneedle electrodes, 0.5 – 3.5 mm (Adjustable depth) SFR: Up to 144 pins Display: Color Touch LCD (Total Shot Count Displayed) Dual Switch: Foot & Finger Switch Weight: 28 kg Dimension: 362 mm (W) x 409 mm (L) x 1713 mm (H) Location: Lower Face Submental, Neck, Forehead, Periorbital Pass: Pass1: 2.25 – 3.5 mm, Pass2: 1.5 – 2.25 mm, Pass3: 1.0 – 1.25 mm Intensity: Low, Medium, High MANUFACTURER NOTES: Infini Radiofrequency Microneedling The LUTRONIC INFINI is the ideal solution to create targeted and robust coagulation zones in aging, sagging skin with pigmentation, wrinkles and laxity. Complete control over treatment depth and energy levels enables a multi-layered targeted approach for truly customized treatments, regardless of patients skin type or tanned skin. Now you can provide the best solution for results your patients demand year round. UNIQUE TECHNOLOGY, AMAZING RESULTS Infinis proven & impressive design delivers enhanced wrinkle reduction through 3-dimensional energy delivery to volumize tissue. RF energy delivered via insulated gold-coated microneedles creates precise and controllable fractionated coagulation zones within a specific layer of dermis. Adjustable depth control allows for customized and reproducible treatments of delicate areas. Infini effectively lowers the risk of PIH in dark skin types and can be safely used on patients with melasma and other types of pigmented lesions. Lutronics patented ComfortFlow technology maximizes comfort and patient satisfaction. INFINI is unique technology that puts you in control of your skin rejuvenation procedure. You control the treatment depth and energy levels to enable a multi-layered approach for customized treatments, regardless of skin type or tan. Now you can provide the best solution that will keep your patients returning and referring you to new patients.
IDEAL FOR:2018 Lutronic Infini RF Microneedling Skin Tightening– Acne Scars
– Skin tightening– Wrinkles and fine lines– Active inflammatory acne– Enlarged pores– Scar treatment– Stretch marks– Hyperhidrosis – Over production of sweat– Excessive sebum (face oil) production | 2018 Vivace RF Microneedling Radio Frequency Acne ScarsTHE VIVACE EXPERIENCE
The most exciting new technology for aesthetic treatments is the combination of two methods previously used individually for skin rejuvenation, Microneedling and RF Energy. FDA-cleared for your safety, the newest generation, best-in-class Vivace RF Microneedling device, is designed for an incomparable, comfortable experience. Only Vivace boasts a precision robotic motor that brings discomfort to a virtual zero compared to any other device. The results are immediate and improve over time as well, giving you the best of both worlds. Our carefully developed recovery system ensures no one knows you just had a treatment. If you are looking for optimal results, there is no comparison to The Vivace Experience.What is Vivace Fractional RF Microneedling?
The Vivace RF Laser Radio Frequency is the newest generation of microneedling with radio frequency and is effective for fine lines and wrinkles, skin tightening, acne, acne scars, and skin tone, texture and pore size, both on and off the face. It is the most revolutionary contouring and skin tightening system for face, neck, hands and body available, producing immediate, pain-free results.Safe for all skin types, Vivace can offer similar results as ablative and fractional laser procedures, but with significantly less discomfort, downtime, and risk of complications. This revolutionary new treatment also addresses the limitations of older ‘traditional’ RF treatments and heats deeper tissues to a much higher level, which leads to greater collagen production, elastin remodeling and wound contraction previously unattainable with older technology. This is why the Vivace is a game changer in skin rejuvenation and tightening. CLICK HERE to learn moreSlate combines the best device with the newest breakthroughs in numbing, treatment serums and recovery care to create an optimal experience for you that might just keep you from needing other more invasive procedures down the road. The Vivace Experience provides the most dramatic results with less pain and less downtime. The results are both immediate and improve over time with multiple treatments. With results you can see, you’ll look and feel your best at any age.Slate Medspa is the premier Fractional RF Microneedling provider in NJ. We use the most advanced technology to provide a results-oriented skin rejuvenation program. New to Slate Medspa? Call us today at 201-477-5781 to schedule a free consultation and save 20% off your first treatment.How does Vivace Fractional RF Microneedling work?
The Vivace utilizes radio frequency and microneedling to heat the targeted area underneath the epidermis. The Vivace dramatically improves the treatment outcomes compared to other radio frequency microneedling systems.By using insulated needles, Vivace bypasses the epidermis and delivers powerful RF thermal energy to create tens of thousands of fractional coagulation zones in the dermis, facilitating a natural wound healing process. This promotes production of new collagen, remodeling of elastin and wound contraction, enhancing skin laxity. Because the thermal energy is delivered beneath the top layer of skin,Benefits of VIVACE:2018 Vivace RF Microneedling Radio Frequency Acne Scars
Minimizes/Eliminates Fine Lines and Wrinkles
Minimizes/Eliminates Acne Scars & Stretch Marks
Skin Tightening & Texture – Stimulates collagen and elastin production
Treat Sun Damage/Age Spots/Hyperpigmentation
8 Reasons why Slate LOVES Vivace™ RF Microneedling
You’ll see results quickly
Vivace works faster than any other microneedling or laser option. First, the RF Energy creates micro injuries deep in the skin in the form of a matrix. Healthy cells around the newly created matrix promote rapid healing, accelerating collagen production and skin tightening. Secondly, the invisible microchannels in the skin created by the superfine gold-tipped needles remain open for four to six hours allowing maximum absorption the key nutrients and serums applied during the treatment. This would include growth factors, HAs and other cosmeceuticals delivered to the skin in a way that no other treatment can, helping to rapidly rebuild new collagen and elastin.The average patient gets optimal results in just three treatments
Most patients experience noticeably softer, smoother and radiant skin, with improvements in tone, texture and laxity after just one treatment. We can typically achieve optimal results after only three sessions!The treatment is virtually painless
The Vivace Microneedle RF was designed for an incomparable, comfortable patient experience. The unique robotic motor is so precise, it brings the discomfort level to a virtual zero as compared to any other device. The Vivace’s ultra thin needles make it virtually pain-free. A numbing cream is applied before treatment for you to stay comfortable. Our patients here at Slate Medspa consistently report a pain level of “1” on a scale of 1 to 10.There’s no downtime
Vivace’s ultra-thin needles and robotic-assisted mechanism result in an exceptionally precise, even treatment with little-to-no bleeding. In addition, built-in LED Light therapy minimizes post-treatment redness. While we ask patients to wait until the next day before applying makeup, most feel comfortable going out without any makeup.It’s safe for almost any skin type
Patients with darker skin tones can have a more challenging time finding suitable skin resurfacing treatments, as lasers and peels that remove skin layers can risk permanent pigmentation changes. Vivace has 31 Adjustable depths, providing flexibility in treating entire depth or just down deep, bypassing damage to the top layer of skin. This means we can treat a broader array of skin types and tones with absolute precision. In addition, a variable pulse duration means the length of time the needle is engaged with tissue can be precisely controlled based on your skin profile. |
Reviews
There are no reviews yet.