PERKASA MEDICAL

Free shipping worldwide. Orders over $200
Availability: In Stock

PALOMAR ACLEARATHERAVANT THERACLEAR MACHINE

$5,500.00

Includes:
1 Handpiece
12 Disposable Insert Tips
1 Operator Eyewear
1 Patient Eyewear
1 Operators Manual.

Other people want this. 15 people have this in their carts right now.

Description

PALOMAR ACLEARATHERAVANT THERACLEAR MACHINE

Palomar AclearaTheravant TheraClear Acne Clearing Laser, Includes:
1 Handpiece
12 Disposable Insert Tips
1 Operator Eyewear
1 Patient Eyewear
1 Operators Manual.

Palomar AclearaTheravant TheraClear Acne Clearing Laser

The Acleara system is powered by advanced vacuum and filtered broadband light technology to treat mild to moderate acne (acne vulgaris), comedonal acne and pustular acne.
Visible Improvement:
• Reduction in peri-lesional erythema and a visible calming of lesion

FDA-Cleared for Most Types of Mild to Moderate Acne:
• Mild to moderate inflammatory acne (acne vulgaris)
• Comedonal acne
• Pustular acne
• Cleared for use on all skin types

Hygenic and Comfortable Treatments:
• Reduced risk of cross contamination
• No anesthetics, numbing or cooling gels required

Fast Treatments:PALOMAR ACLEARATHERAVANT THERACLEAR MACHINE
• Full face treatment in under 15 minutes

Palomar Acleara/Theravant TheraClear Acne Clearing Laser; Excellent Cosmetic and Operating Condition

Wavelength:500 nm – 1200 nm
Spot Size:12.7 mm x 25.4 mm and 10.2 mm x 12.5 mm
Pulse Width:Up to 25 ms; Short Pulse – 3 ms, Long Pulse – 25 ms
Fluence/Energy:Up to 25 J/cm²; Single Pulse – up to 8 J/cm², Double Pulse – up to 16 J/cm², Triple Pulse – up to 24 J/cm²
Light Delivery:Three (3) Xenon flash lamps withing handpiece. Limited to approximately 100,000 pulses.
Repetion Rate: up to 0.5 hz; Single Pulse – One pulse every 2 seconds, Double Pulse – One pulse every 2.5 seconds, Triple Pulse – One pulse every 3 seconds
Actuator:Tripper (hand switch) on handpiece
Voltage, Frequency and Current:100-240VAC, 50/60Hzz, 10A
Max Power Input:Up to 45 kW
Dimensions:13″ x 16.5″ x 15″ (330 x 420 x 380 mm)
Operating Radius of Umbilical:70″ (1.8 M)
Weight:37 lbs (17 kG)

Reviews

There are no reviews yet.

Be the first to review “PALOMAR ACLEARATHERAVANT THERACLEAR MACHINE”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsPALOMAR ACLEARATHERAVANT THERACLEAR MACHINE removeDuetto Laser Quanta System For Sale remove2020 CRYOMED CLATUU ALPHA FOR SALE removeActive Optical Extra 818 IPL Hair Removal 2015 For Sale removeACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER FOR SALE removeCUTERA SECRET RF 2.0 FOR SALE remove
NamePALOMAR ACLEARATHERAVANT THERACLEAR MACHINE removeDuetto Laser Quanta System For Sale remove2020 CRYOMED CLATUU ALPHA FOR SALE removeActive Optical Extra 818 IPL Hair Removal 2015 For Sale removeACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER FOR SALE removeCUTERA SECRET RF 2.0 FOR SALE remove
Image
SKU
Rating
Price $5,500.00 $5,300.00 $14,550.00 $7,200.00 $6,500.00 $12,900.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

DescriptionIncludes: 1 Handpiece 12 Disposable Insert Tips 1 Operator Eyewear 1 Patient Eyewear 1 Operators Manual.

hair removal laser / skin rejuvenation / vascular lesion treatment / onychomycosis treatment

Fast and Easy Applicator Exchange With a simple press-and-release mechanism, the Clatuu Alpha allows maximum convenience and makes switching cooling cups as simple as possible. Detaching cables or turning the system off is not required even during treatments.2015 Active Optical Extra 818 IPL Hair Removal and Skin Rejuvenation; Excellent Cosmetic and Operating Condition, Very Lightly Used for Demonstrations Only, Single Owner; Included Handpieces and Pulse Counts: Hair Removal Handpiece = 6,617 Pulses, Facial Handpiece = 2,190, Life for Each Handpieces is 250,000 Pulses.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER includes: Handpiece, Footswitch, Operator Eyewear, Patient Eyewear, Cart, Key, Operator Manual, ultrasound gel, replacement fuses, replacement filtersThe ability to work specifically in the deep dermis, without damaging the epidermis, is regulated in the RF Secret by the delay time of fractional radiofrequency. The needles are inserted at a rate of milliseconds equal to a stamping process in the skin and also withdrawn immediately. Only after the needles are penetrated into the desired skin layer, is carried out for a few milliseconds, a radio frequency pulse to set heat damage. While the penetration into the skin, the needles remain always cold. In order to achieve a deep and superficial effect, the needle depths can be varied individually in the respective treatment passes.
ContentPALOMAR ACLEARATHERAVANT THERACLEAR MACHINEPalomar AclearaTheravant TheraClear Acne Clearing Laser, Includes: 1 Handpiece 12 Disposable Insert Tips 1 Operator Eyewear 1 Patient Eyewear 1 Operators Manual.Palomar AclearaTheravant TheraClear Acne Clearing LaserThe Acleara system is powered by advanced vacuum and filtered broadband light technology to treat mild to moderate acne (acne vulgaris), comedonal acne and pustular acne. Visible Improvement: • Reduction in peri-lesional erythema and a visible calming of lesionFDA-Cleared for Most Types of Mild to Moderate Acne: • Mild to moderate inflammatory acne (acne vulgaris) • Comedonal acne • Pustular acne • Cleared for use on all skin typesHygenic and Comfortable Treatments: • Reduced risk of cross contamination • No anesthetics, numbing or cooling gels requiredFast Treatments:PALOMAR ACLEARATHERAVANT THERACLEAR MACHINE • Full face treatment in under 15 minutesPalomar Acleara/Theravant TheraClear Acne Clearing Laser; Excellent Cosmetic and Operating ConditionWavelength:500 nm – 1200 nm Spot Size:12.7 mm x 25.4 mm and 10.2 mm x 12.5 mm Pulse Width:Up to 25 ms; Short Pulse – 3 ms, Long Pulse – 25 ms Fluence/Energy:Up to 25 J/cm²; Single Pulse – up to 8 J/cm², Double Pulse – up to 16 J/cm², Triple Pulse – up to 24 J/cm² Light Delivery:Three (3) Xenon flash lamps withing handpiece. Limited to approximately 100,000 pulses. Repetion Rate: up to 0.5 hz; Single Pulse – One pulse every 2 seconds, Double Pulse – One pulse every 2.5 seconds, Triple Pulse – One pulse every 3 seconds Actuator:Tripper (hand switch) on handpiece Voltage, Frequency and Current:100-240VAC, 50/60Hzz, 10A Max Power Input:Up to 45 kW Dimensions:13″ x 16.5″ x 15″ (330 x 420 x 380 mm) Operating Radius of Umbilical:70″ (1.8 M) Weight:37 lbs (17 kG)

Duetto Laser Quanta System

The device at a glance The Duetto MT – EVO Family system is based on Alexandrite and Nd:YAG lasers, 755 nm and 1064 nm, in single or combined emissions. Duetto MT can meet the necessities of every patient by tailoring the treatments in every detail. Big spot sizes, wide range of pulse widths and fast repetition rate together with the exclusive possibility to set the proportion between Alexandrite and Nd:YAG lasers through the Mixed Technology, make this device one of the most advanced and flexible laser in Aesthetics and Dermatology field especially for the Hair Removal, Vascular and Skin Rejuvenation treatments. The TWAIN optional handpieces can be installed at any time on the field and can expand the range of applications even more.Mixed Technology Duetto MT equipped with the second generation of consolidated proprietary Mixed Technology which is able to perform the largest range of hair removal applications, as well as vascular and rejuvenation treatments. Duetto MT allows the operators to easily select single or double wavelength emissions adapting the treatment to all skin types more precisely.Contact Skin Cooler or Air Skin Cryo Effective skin cooling is essential forost lasers. The integrated contact skin cooler of Duetto MT can be used with or without a sapphire window at three different target temperature. The Skin Cryo handpiece adapter, instead, is intended to work in combination with an external compatible air cooling unit to provide a cold air flow designed for the reduction of pain and thermal injury on wide areas.Duetto Laser Quanta SystemThe TWAIN options are based on IPL or laser handpieces that can also be installed at the clinic’s site any time. Twain IPL option is based on Intense Pulsed Light technology, it has different optical filters or different handpieces that can have integrated skin cooling (depending on the model and wavelength). It is indicated for: Hair Removal | Dermatological vascular treatments | Benign pigmented lesions | Skin rejuvenation | Active acne Twain 2940 is an Er:YAG laser handpiece ideal for skin ablations with confined thermal diffusion for excellent safety scores. It is indicated for: Normal spots: Skin ablation | Full skin resurfacing Fractional: Skin resurfacing | Traumatic and acne scars | Epidermal dyschromia | Sun and age spots

2020 CRYOMED CLATUU ALPHA

Clatuu Alpha is a leading dual-sculpting system with precise 360° surround cooling that achieves maximum coverage of the treatment area and provides fast and effective dual handpiece fat-freezing treatments. The Clatuu system maintains a constant target temperature that prevents unwanted side effects with a proven track record of dependability and clinical efficacy.Fast and Easy Applicator Exchange With a simple press-and-release mechanism, the Clatuu Alpha allows maximum convenience and makes switching cooling cups as simple as possible. Detaching cables or turning the system off is not required even during treatments.Various Applicators for any Spot 2020 CRYOMED CLATUU ALPHA The CLATUU Alpha’s wide range of cooling cups are designed to perfection within our R&D labs and are suitable to conform to a large variety of body shapes and patients. Each individual cup helps to achieve a variety of customized treatment plans to effectively reduce fat cells for the ultimate dual sculpting body contouring experience.Applicators Optimized for Any Treatment After laborious testing and research, each individual cooling cup has been ergonomically designed to adhere to each curve of the body. The Clatuu Alpha has been optimized to achieve desired outcomes from head to toe.Advanced Technology for Maximum Results Having accumulated countless hours in research and development, the Clatuu Alpha features a revolutionary approach to absolute, non-invasive body contouring through a more powerful cooling technology. Upgraded 360° Surround Cooling 360° Surround Cooling Technology unlike the conventional two-sided cooling methods, increases efficiency by up to 18.1%. Allowing delivery of cooling to the entire cup and in result removes fat cells more effectively.Sculpt with two applicators in one device The Clatuu Alpha has the ability to have two high-speed handpiece applicators treating at the same time allowing duo sculpting to take place. Faster to Target Point The cooling system of the Clatuu Alpha is engineered to reach its target temperature faster than previous models, reducing the inconveniences of waiting and maximizing time efficiency for both patients and physiciansAdjustable Levels Not only is the Clatuu Alpha capable of 20% stronger suction, it also provides medical practitioners with the ability to adjust both cooling and suction levels to confidently provide customized treatments for patients.Science Behind ALPHA Each cooling applicator is engineered to target the patient’s subcutaneous fat layer without damaging surrounding tissues or nerve regions, It is through this advanced cooling technology that we are able to welcome you to the Innovative Age of ALPHA.

Active Optical Extra 818 IPL Hair Removal 2015

Handpieces:Hair Removal Handpiece and Facial Handpiece Chilled Tip:Up to 4c Pulse Interval:0.5~2 Seconds Output Power:11-31 joule/cm2, upto 4,000W Cooling System:Revolutionary dual cooling Control:Intuitive touch screen control Lamp’s Life Span:250,000 Flashes (Universal), 200,000 Flashes (Facial) Treatment Area:7.5 cm2 (15*50mm) Universal, 4.5 cm2 (15*30mm) Facial Wavelength:420-1100 nm Weight:42Kg (including Stand, if device is not a table top) Dimensions:44cm x 45cm x 100cm
Extra-818Skin Rejuvenation Pigmentation Treatment Acne Treatment Hair Removal Vascular (Facial) TreatmentThe Extra – 818 is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features: * Contemporary touch screen control * Built-in Patch Test procedure for examining the optimal energy level * A stunning number of 450,000 flashes in both lamps.The Extra – 818, based on Active’s GEM-PL technology, sets sets a specific Pulse Pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.The combination of tested treatment protocols with high end engineering makes the Extra – 818 the perfect device for leading clinics.Revolutionary Cooling System The Extra – 818 has a dual cooling system, controlled and monitored in order to ensure long lifetime to the lamp and a comfortable treatment to the patient.Competitive cooling systems “freeze” the skin so that during the treatment the skin temperature will rise to a bearable level. However, this “freezing” temperature might limit the results because the follicles will not reach the coagulation temperature. To ensure optimal results Active installed a special Processor that prevents overcooling the skin and maintains a uniform low temperature of the “glass” throughout the treatment. This revolutionary system enables the Extra – 818 to provide best results with optimal patient comfort.Research Program Active Optical Extra 818 IPL Hair Removal 2015  For clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31Jcm2 with high intensity of 4,000W.
Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II Handpiece (Optional):Facial Treatments Pulse Interval/Repetition Rate:0.5 – 2 Seconds Maximum Output Treatment Pattern:22 Joule /cm 2 Output Power:11-31 Joule / cm 2 , up to 4000 W Cooling System:Improved Air Cooling Control:Advanced Software Interface Lamp’s Life Span:200,000 Flashes (minimum) Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2) Wavelength:420 – 1,100 nm Weight:88.18 lbs (40Kg) (including stand) Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm) Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz Max Mains Power:600 VA Treatments Variety: Skin Rejuvenation Pigmentation Treatment Acne Treatment Hair Removal Hair Removal – Deep Follicles Hair Removal – Sensitive Skin Vascular (Facial) Treatment Tattoo Removal ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERr uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated. 12 Programs 1 – Very Dark Skin, Fitzpatrick Skin Type IV 2 – Dark Skin, Fitzpatrick Skin Type IV 3 – Dark Skin, Fitzpatrick Skin Type III 4 – Dark Skin, Fitzpatrick Skin Type III 5 – Medium Skin, Fitzpatrick Skin Type II 6 – Medium Skin, Fitzpatrick Skin Type II 7 – Light Skin, Fitzpatrick Skin Type II 8 – Light Skin, Fitzpatrick Skin Type I 9 – Very Light Skin, Fitzpatrick Skin Type I 10 – Very Light Skin, Fitzpatrick Skin Type I 11 – Very Light Skin, Fitzpatrick Skin Type I 12 – High Power, Fitzpatrick Skin Type IActive Optical Systems Optima 518 IPL LaserOptima-518-Classic The Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERNew Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece: * Faster treatments – up to 0.5 Seconds Between pulses. * Real-time handpiece temperature control. * Contemporary and stylish design. * Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER Approvals * CE MDD Intl. Medical Standard * FDA U.S. Safety Standard * ISO-13485 Med. Production STD * IEC 60-601-1 Medical Safety STD * CFS Gov. Health Approval * CSA Can. & U.S. Safety App * TGA Australian health STD.CUTERA SECRET RF 2.0CUTERA SECRET RF 2.0 MICRONEEDLING RADIO is a fractional micro-needling system (fractional radiofrequency) that exceeds the capabilities and limitations of fractional laser significantly. It is a system for extensive skin structure improvement and treatment of hyperhidrosis (radio frequency thermotherapy RFTT), based on both monopolar and fractionated on, bipolar radio frequency. An exact adjustment of the depth of the microneedles and the “cold” passing the epidermis allow the energy output directly into the target layer. The needle depth is 0.5 mm to 3.5 mm can be varied, thereby opening up a wide range of treatments. The adjustable intensity of the RF energy allows for the treatment of various areas of the body with different energy performance.The ability to work specifically in the deep dermis, without damaging the epidermis, is regulated in the RF Secret by the delay time of fractional radiofrequency. The needles are inserted at a rate of milliseconds equal to a stamping process in the skin and also withdrawn immediately. Only after the needles are penetrated into the desired skin layer, is carried out for a few milliseconds, a radio frequency pulse to set heat damage. While the penetration into the skin, the needles remain always cold. In order to achieve a deep and superficial effect, the needle depths can be varied individually in the respective treatment passes.Dermal Remodeling from the Inside Out Demand for non-surgical aesthetic procedures with little to no downtime is on the rise. More than 70% of patients are bothered by signs of aging such as fine lines and wrinkles as well as skin texture and discoloration.1Secret RF is a novel fractional radio frequency (RF) micro-needling system for tissue coagulation and hemostasis designed to stimulate and remodel collagen and address the common signs of aging. It is ideally suited for use on patients who wish to revitalize and refresh the appearance of their skin on all skin types. By adjusting the micro-needles, Secret RF can deliver energy at various depths, so that treatments can be tailored to address each patients individual concerns such as fine lines, wrinkles, acne scars, photoaging and striae at the depth required.Secret RF System Secret RFs unique technology and customized delivery of energy enables providers to tailor treatments for a variety of skin concerns on all skin types.Customized Dermal Remodeling Secret RF induces dermal remodeling by applying precisely controlled RF energy directly into various depths of skin  from 0.5-3.5 mm – with minimally invasive micro-needles to spare the epidermis and reduce patient downtime.

Skin Revitalization and Resurfacing

Secret RF is a radio frequency (RF) fractional microneedling system that helps you deliver tailored energy to improve fine lines, wrinkles, and scars from the inside out.

Secret RF in action

Applications include fine lines and wrinkles, photoaging, scarring, acne scars, striaeSecret RF technology

Handpieces

Two sizes of treatment tips – 25 and 64 pin – give you customizable options for treating the face and body with precision and efficiency.
Power:20 W ± 20% RF frequency:2 Mh ± 20% Intensity:0 ~ 100 Level (10 levels) Repeat:0.2 / 0.5 / 1/2 sec / individually. Needle Size:0.3 mm Info about needles:25 electric needles (5 x 5, 7.8 mm x 7.8 mm / height: 1.95 mm (standard) and 16 electric needles (4 x 4, 7.8 mm x 7.8 mm / height 2.6 mm (optional) Treatment range:1 x 1cm Adjustable Depth:0.5 ~5 mm (0.1 steps) Treatment duration:50 ms ~ 950 ms Electrical power:100 ~ 240 VAC, 50/60 Hz, 220 VAMonopolar RF Power:520 W ± 20% RF frequency:2 Mh ± 20% RF electrode:monopolar Repeat:CW RF electrode size:15APPLICATIONSFacialsNon-surgical facelift Skin tightening Pore reduction Wrinkle reduction Skin Rejuvenation (illumination) Acne scars Body treatmentsScar Keratosis pilaris (Keratosis pilaris) Stretch marks
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: PALOMAR ACLEARATHERAVANT THERACLEAR MACHINE $5,500.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Shopping cart close