| Description | Includes:
1 Handpiece
12 Disposable Insert Tips
1 Operator Eyewear
1 Patient Eyewear
1 Operators Manual. | The M6 therapy laser is a robotized multi-target device designed to treat patients suffering pathologies affecting a wide area, and to perform automatic applications. The distinctive feature of the M6 is the innovative multi-target functioning. Thanks to the features of the exclusive MLS multi-diodic optical group, a wide area is treated instantaneously helping to produce an immediate response of the treated tissues. The results are better and faster than with the scanning modality of traditional laser therapy products. | ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER includes: Handpiece, Footswitch, Operator Eyewear, Patient Eyewear, Cart, Key, Operator Manual, ultrasound gel, replacement fuses, replacement filters | LOGIQ e Needle Recognition Software Option which helps provide precise and accurate display of the needle, anatomy and motion even in Color and Power Doppler. This feature harnesses pattern recognition technology that recognizes and accurately reveals the structure of a needle within the anatomy, without distortion of the needle and compromising the target. | The ability to work specifically in the deep dermis, without damaging the epidermis, is regulated in the RF Secret by the delay time of fractional radiofrequency. The needles are inserted at a rate of milliseconds equal to a stamping process in the skin and also withdrawn immediately. Only after the needles are penetrated into the desired skin layer, is carried out for a few milliseconds, a radio frequency pulse to set heat damage. While the penetration into the skin, the needles remain always cold. In order to achieve a deep and superficial effect, the needle depths can be varied individually in the respective treatment passes. | Highest available power allows for fast treatments, customizable for multiple areas
Gentle, effective global improvement for all skin types, all year-round
Comfortable treatments with very little downtime
Minimal cost of ownership, easy to delegate and no shot limit per procedure |
| Content | PALOMAR ACLEARATHERAVANT THERACLEAR MACHINEPalomar AclearaTheravant TheraClear Acne Clearing Laser, Includes:
1 Handpiece
12 Disposable Insert Tips
1 Operator Eyewear
1 Patient Eyewear
1 Operators Manual.Palomar AclearaTheravant TheraClear Acne Clearing LaserThe Acleara system is powered by advanced vacuum and filtered broadband light technology to treat mild to moderate acne (acne vulgaris), comedonal acne and pustular acne.
Visible Improvement:
Reduction in peri-lesional erythema and a visible calming of lesionFDA-Cleared for Most Types of Mild to Moderate Acne:
Mild to moderate inflammatory acne (acne vulgaris)
Comedonal acne
Pustular acne
Cleared for use on all skin typesHygenic and Comfortable Treatments:
Reduced risk of cross contamination
No anesthetics, numbing or cooling gels requiredFast Treatments:PALOMAR ACLEARATHERAVANT THERACLEAR MACHINE
Full face treatment in under 15 minutesPalomar Acleara/Theravant TheraClear Acne Clearing Laser; Excellent Cosmetic and Operating ConditionWavelength:500 nm – 1200 nm
Spot Size:12.7 mm x 25.4 mm and 10.2 mm x 12.5 mm
Pulse Width:Up to 25 ms; Short Pulse – 3 ms, Long Pulse – 25 ms
Fluence/Energy:Up to 25 J/cm²; Single Pulse – up to 8 J/cm², Double Pulse – up to 16 J/cm², Triple Pulse – up to 24 J/cm²
Light Delivery:Three (3) Xenon flash lamps withing handpiece. Limited to approximately 100,000 pulses.
Repetion Rate: up to 0.5 hz; Single Pulse – One pulse every 2 seconds, Double Pulse – One pulse every 2.5 seconds, Triple Pulse – One pulse every 3 seconds
Actuator:Tripper (hand switch) on handpiece
Voltage, Frequency and Current:100-240VAC, 50/60Hzz, 10A
Max Power Input:Up to 45 kW
Dimensions:13″ x 16.5″ x 15″ (330 x 420 x 380 mm)
Operating Radius of Umbilical:70″ (1.8 M)
Weight:37 lbs (17 kG) | Cutting Edge MLS M6 Laser Therapy Unit
The M6 therapy laser is a robotized multi-target device designed to treat patients suffering pathologies affecting a wide area, and to perform automatic applications. The distinctive feature of the M6 is the innovative multi-target functioning. Thanks to the features of the exclusive MLS multi-diodic optical group, a wide area is treated instantaneously helping to produce an immediate response of the treated tissues. The results are better and faster than with the scanning modality of traditional laser therapy products.Technical Features
Robotized optical group with 3 MLS sources – power up to 3.3 W
5 cm diameter target area highlighted by high-efficiency red light LEDs
Back-lit graphic touch-screen display
Simultaneous management of two independent channels
MLS pulse modulation frequency from 1 to 2000 Hz with 1 Hz steps
Power level 50% and 100%
Variable or fixed duty cycle
Treatment duration from 1″ to 99’59” with 1″ steps
Automatic calculation of the emitted energy according to the set parameters
Alarms and Safety Features
Laser emission warning light
Interlock (can be temporarily disabled)
Acoustic signal for the beginning and the end of the therapy, and for each treatment second (can be disabled)
Password to operate the device
Language option (Italian, English, German, Spanish)
Dimensions and Weight
27 x 17 x 62 inches; 95 lbsPower Supply
115/230V~ 50/60Hz 150VACUTTING EDGE MLS M6 Laser Therapy UnitTalk to your specialist.
Since 1983 we have been working to be the reference point in Laser Therapy and Magnetotherapy in many areas: from physiotherapy to rehabilitation, from the management of muscle and joint pain to sports medicine. The result of our work allows us today to be recognized as an international leader in the knowledge and development of advanced technologies in the field of “pain management”: a recognition confirmed in 2003 with the entry of the El.En Group. (Star segment of the Italian Stock Exchange – ELN.MI), one of the most important realities in the laser world, both for industrial and medical applications.We have always thought that research is not only confirmation, but also the necessary premise for our work. Born from the synergy between ASAlaser and the Department of Experimental and Clinical Biomedical Sciences of the University of Florence , the ASAcampus laboratory allows us to test the validity of our work and improve results over time. The result of the research is disseminated through conferences, supported thanks to important partnerships and disseminated through numerous scientific publications.Our medical devices for MLS ® Laser Therapy , Hilterapia ® and Magnetotherapy are built according to contents that we consider indispensable: advanced technologies and software, efficacy and safety, ergonomics and design. They allow for ever more targeted and personalized treatment methods. The effectiveness of our therapies is continuously tested thanks to the research carried out in ASAcampus whose results are constantly transferred to clinical applications. | Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERr uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IActive Optical Systems Optima 518 IPL LaserOptima-518-Classic
The Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERNew Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. | GE Logiq E R7 Portable Ultrasound Machine
The NextGen LOGIQ combines the high performance of a console system with the portability of a laptop. GE Healthcare’s compact system is designed for general imaging, musculoskeletal, anesthesiology, interventional, emergency, and critical care applications.It provides ultrasound imaging with precise anatomical detail at a variety of depths. The system includes innovative features that help simplify interventional procedures.LOGIQ e Needle Recognition Software Option which helps provide precise and accurate display of the needle, anatomy and motion even in Color and Power Doppler. This feature harnesses pattern recognition technology that recognizes and accurately reveals the structure of a needle within the anatomy, without distortion of the needle and compromising the target.Also includes the ability to adjust needle gain and angle.- Standard package includes AC power cord (USA)
- internet cord 3 meter in length CAT-5 type
- PC to HUB structure
- system software on USB
- Optional Function Key Label
- Ultrasound Transmission Gel .25L
- English Basic Service Manual CD and English User Guide and AIUM booklet.
The following scanning modes are included:- B-mode
- M-mode
- Anatomical M-mode
- Color flow mode
- Power Doppler imaging
- Pulsed wave Doppler and Ophthalmic
Features:The NextGen LOGIQ ecombines the high performance of a console system with the portability of a laptop. GE Healthcare’s compact system is designed for general imaging, musculoskeletal, anesthesiology, interventional, emergency, and critical care applications.Display Screen:- 15 in High-Resolution Color LCD
- Resolution: 1024 x 768
- Horizontal/Vertical viewing angle: +/-80 degree
- Brightness AdjustmentIntegrated Speakers
- Audio Volume Adjustment
- Interactive Dynamic Software Menu
Console Design:- Laptop Style
- Lithium Ion Battery
- Integrated Solid State Drive
- CPU – Intel Duo Core
- Operating System – Microsoft® Windows® 7
Console Interfaces:- DC Power Input
- USB 2.0 (3)
- LAN 10/100/1000 BaseT
- Docking Cart Connector
- HDMI
Standard Features:- Integrated Solid State Drive
- Automatic Optimization
- CrossXBeamTM
- Speckle Reduction Imaging (SRI-HD)
- Virtual Convex/Virtual Apex
- Fine Angle Steer
- HD Zoom (Write Zoom)
- Coded Harmonic Imaging (CHI)
- Raw Data Processing
- Quicksave
- On-board User Manual (Help)
- InSiteTM ExC capability
- Loop storage—from live scanning and from memory
- Patient Information Database
- Customizable User Interface
- Full M&A Calculation Package with Real Time Auto Doppler Calculations
- Vascular Calcs
- Cardiac Calcs
- OB Calcs and Tables
- Fetal Trending
- Multi Gestational Calcs
- Musculoskeletal and Hip Dysplasia Calcs
- Gynecological Calcs
- Urological Calcs
- Renal Calcs
- Small Parts Calcs
- Rheumatology Calcs
- Pediatric Calcs
- Report Writer Package
Software Options:- easy3D
- LOGIQ View
- Needle Recognition
- Stress Echo
- eSmart Trainer
- Auto IMT
- DICOM® 3.0 Connectivity/Encrypted DICOM
Specifications: Console Dimensions Height- 70 mm (2.75 in) console only
- 100 mm (3.94 in) with handle
Width- 295 mm (11.61 in) console only
- 343 mm (13.50 in) with handle
Length- 346 mm (13.62 in) console only
- 375mm (14.76 in) with handle
Weight with Battery: Approximately 5.2 Kg (11.5 lbs)Operator Keyboard- Alphanumeric Keyboard
- Ergonomic Hard Keys
- Backlight Keys
Display Screen- 15 in High-Resolution Color LCD
- Resolution: 1024 x 768
- Horizontal/Vertical viewing angle: +/-80 degree
- Brightness Adjustment
- Integrated Speakers
- Audio Volume Adjustment
- Interactive Dynamic Software Menu
Console Electrical Power- Voltage: 100-240 V AC
- Frequency: 50/60 Hz
- Power: Max. 130 VA
Applications:GE Logiq E R7 Portable Ultrasound Machine- Abdomen
- Cardiac
- Gynecology
- Musculoskeletal
- Obstetrical
- Nerve Block
- Pediatric
- Small Parts
- Urological
- Vascular
- Rheumatology
- Emergency Medicine
- Cardiac intra-operative
| CUTERA SECRET RF 2.0CUTERA SECRET RF 2.0 MICRONEEDLING RADIO is a fractional micro-needling system (fractional radiofrequency) that exceeds the capabilities and limitations of fractional laser significantly. It is a system for extensive skin structure improvement and treatment of hyperhidrosis (radio frequency thermotherapy RFTT), based on both monopolar and fractionated on, bipolar radio frequency. An exact adjustment of the depth of the microneedles and the cold passing the epidermis allow the energy output directly into the target layer.
The needle depth is 0.5 mm to 3.5 mm can be varied, thereby opening up a wide range of treatments. The adjustable intensity of the RF energy allows for the treatment of various areas of the body with different energy performance.The ability to work specifically in the deep dermis, without damaging the epidermis, is regulated in the RF Secret by the delay time of fractional radiofrequency. The needles are inserted at a rate of milliseconds equal to a stamping process in the skin and also withdrawn immediately. Only after the needles are penetrated into the desired skin layer, is carried out for a few milliseconds, a radio frequency pulse to set heat damage. While the penetration into the skin, the needles remain always cold. In order to achieve a deep and superficial effect, the needle depths can be varied individually in the respective treatment passes.Dermal Remodeling from the Inside Out
Demand for non-surgical aesthetic procedures with little to no downtime is on the rise. More than 70% of patients are bothered by signs of aging such as fine lines and wrinkles as well as skin texture and discoloration.1Secret RF is a novel fractional radio frequency (RF) micro-needling system for tissue coagulation and hemostasis designed to stimulate and remodel collagen and address the common signs of aging. It is ideally suited for use on patients who wish to revitalize and refresh the appearance of their skin on all skin types. By adjusting the micro-needles, Secret RF can deliver energy at various depths, so that treatments can be tailored to address each patients individual concerns such as fine lines, wrinkles, acne scars, photoaging and striae at the depth required.Secret RF System
Secret RFs unique technology and customized delivery of energy enables providers to tailor treatments for a variety of skin concerns on all skin types.Customized Dermal Remodeling
Secret RF induces dermal remodeling by applying precisely controlled RF energy directly into various depths of skin from 0.5-3.5 mm – with minimally invasive micro-needles to spare the epidermis and reduce patient downtime.Skin Revitalization and Resurfacing Secret RF is a radio frequency (RF) fractional microneedling system that helps you deliver tailored energy to improve fine lines, wrinkles, and scars from the inside out. Secret RF in action
Applications include fine lines and wrinkles, photoaging, scarring, acne scars, striaeSecret RF technology Handpieces
Two sizes of treatment tips – 25 and 64 pin – give you customizable options for treating the face and body with precision and efficiency.
Power:20 W ± 20%
RF frequency:2 Mh ± 20%
Intensity:0 ~ 100 Level (10 levels)
Repeat:0.2 / 0.5 / 1/2 sec / individually.
Needle Size:0.3 mm
Info about needles:25 electric needles (5 x 5, 7.8 mm x 7.8 mm / height: 1.95 mm (standard) and 16 electric needles (4 x 4, 7.8 mm x 7.8 mm / height 2.6 mm (optional)
Treatment range:1 x 1cm
Adjustable Depth:0.5 ~5 mm (0.1 steps)
Treatment duration:50 ms ~ 950 ms
Electrical power:100 ~ 240 VAC, 50/60 Hz, 220 VAMonopolar RF
Power:520 W ± 20%
RF frequency:2 Mh ± 20%
RF electrode:monopolar
Repeat:CW
RF electrode size:15APPLICATIONSFacialsNon-surgical facelift
Skin tightening
Pore reduction
Wrinkle reduction
Skin Rejuvenation (illumination)
Acne scars
Body treatmentsScar
Keratosis pilaris (Keratosis pilaris)
Stretch marks | 2015 Lutronic LaseMD Pro Fractional Skin Wrinkles
Lutronic LaseMD Ultra Laser is an impressive upgrade to their already successful LaseMD,” shared Steven Weiner, MD, from Lutronic.“Not only is it more powerful (20 watts vs 12 watts) but it also has a significantly lower consumable cost than competitive systems. The LaseMD ULTRA offers a new larger spot size and incorporates improved ‘top hat’ beam profile. The system also offers an incredibly advanced graphical user interface.“The integration of all the new features with real-time information helps reduce treatment time and achieve satisfying patient results in fewer treatments. Since no anesthesia is required, I can treat a full face in about 6-8 minutes or treat the face, neck and chest in 20 minutes.”Lutronic LaseMD Ultra Laser is yet another example of Lutronic’s commitment to Intelligent Design for Intelligent Care, according to the company in a media release. Features include:Highest available power allows for fast treatments, customizable for multiple areas
Gentle, effective global improvement for all skin types, all year-round
Comfortable treatments with very little downtime
Minimal cost of ownership, easy to delegate and no shot limit per procedure“LaseMD ULTRA is my favorite new addition to my practice. It allows me to treat multiple areas quickly, effectively and for very low cost,” adds Joel Cohen, MD, in the release. “My patients love the comfortable treatments and impressive results with minimal downtime.”The LaseMD ULTRA a high-power platform which provides a full range of applications in all skin types, including:Age spots (lentigos),
Sunspots (solar lentigos),
Freckles (ephilides),
Actinic Keratoses, and
Treatment of other benign pigmented lesions.Fractional Skin ResurfacingWrinkles - Laxity - Scar Reduction - Pigmentation - Melasma - Anti-Aging - Actinic Keratosis Excellent, Pre-Owned Condition
Serviced and Fully TestedMfr: Lutronic
Model: LaseMD PRO
S/N: LS115D047PS
Mfr Date: 06-19-2015LaseMDAdvanced skin resurfacing laser featuring the Thulium 1927nm wavelength, which focuses on coagulation rather than ablation.Suitable for all skin types.Cosmeceutical Delivery SystemLaseMD creates micro-channels in the skin to specific depths to delivery topical serums to the correct layer of the skin and increase absorption. It also features a built in centrifuge/incubator for LaseMD serum Ampoules.Optimized Magnetic Sensor Tracking Scanner Includes: 2015 Lutronic LaseMD Pro Fractional Skin Wrinkles
- LaseMD Workstation with Scanning Handpiece
- LaseMD Rolling Cart
- 2 Handpiece Caps
- FootSwitch Pedal
- System Key
- Power CableSpecifications:
Laser Type: Thulium
Wavelength: 1927nm |
Reviews
There are no reviews yet.