PERKASA MEDICAL

Free shipping worldwide. Orders over $200
Availability: In Stock

Optos California RG Ultra-widefield Retinal Imaging System

$23,500.00

With California, Optos has incorporated new hardware and software technology enabling practitioners to see more, discover more and effectively treat more ocular pathology thus promoting patient health.

In addition to the benefits found with all of the UWF devices from Optos such as 200 degrees or up to 82% of the retina captured in a single image, in multiple modalities, as well as eyecare professionals being able to see 50% more of the retina when compared to other conventional imaging devices, California rg, offers the following benefits:

– Motorized head and chin rest to more easily assist those patients requiring additional assistance during imaging

– Multiple imaging modalities including; 3-in-1 color depth imaging (color, red-free and choroidal in a single image) as well as
Autofluorescence

Other people want this. 15 people have this in their carts right now.

Description

Optos California RG Ultra-widefield Retinal Imaging System

Effectively Cure more ocular conditions

Optos introduces its newest ultra-widefield (UWF™) imaging apparatus, California, which make with specific for vitreoretinal specialists and ophthalmologists.

The compact desktop device was said to provide increased imaging functionality and has introduced a new imaging modality, indocyanine green angiography, used for imaging the choroidal vasculature, which Optos said was the key in the diagnosis, management, and treatment of certain conditions such as neovascular AMD and ailments with choroidal neovascular membranes.

Why California?

With California, Optos has integrated innovative hardware and software technologies allowing professionals to see more, discover more and effectively cure more ocular pathology thus promoting patient wellness. We’re committed to further strengthening our clinical evidence while demonstrating the importance of imaging the entire retina.

[su_quote cite=” Dr. David M. Brown” url=”https://houstonretina.com/David-M-Brown-MD”]”If you had another fluorescein camera, then California will fit in the same area if much smaller. It also does autofluorescence, which is helpful for evaluating geographic atrophy,”[/su_quote]

New proprietary optical hardware optimizes and maintains the resolution of their optomap images throughout the scan of the retina leading to more clarity at the far periphery.

Additionally, comparisons can make between different images or various dates by scrolling through all saved pictures.

The Optos California directional retinal imaging apparatus makes it possible for an immediate 200-degree perspective of a patient’s eye at a single scan, supplying a high-resolution picture in under half a second. Additionally, our advanced 3D OCT scanning instrument, the Topcon Triton, has updated software making glaucoma detection and decision making much easier and stronger

[su_highlight background=”#f5e791″]With optos California, an optometrist may generate over $9,000 – $15,000 a month. California Billed: $55 each picture for each single patients. Earning money every month with optos California[/su_highlight]

Features Optos California RG Ultra-widefield Retinal Imaging System

  • Compact to reduce space requirements
  • New design leads to ease of use and faster image capture
  • Non-mydriatic high-resolution imaging through many cataracts and 2mm pupils saves time in busy practices
  • Browser-based image review enables simple integration and easy access to your data from any connected pc or tablet in a HIPAA compliant environment
  • Interweaved angiography enables parallel capture of fa and icg images without manually switching between imaging modalities

Optos California is available in three models:

  • California icg

California icg design for retinal specialists to maximize management of AMD, uveitic conditions along with other choroidal pathology; it offers the following imaging modalities and image viewing options.

  • California af

California af was made to facilitate retinal tests and document findings.

  • California fa

California fa was made to help in the identification and management of diabetic eye disease and other cardiovascular ailments.

Image Typeoptomap and optomap plus (red and green laser):

  • Color composite
  • green laser View
  • red laser View
  • optomap af (green laser): autofluorescence
  • optomap fa (blue laser): fluorescein angiography
  • optomap icg (infra-red): indocyanine green angiography

Reviews

There are no reviews yet.

Be the first to review “Optos California RG Ultra-widefield Retinal Imaging System”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsOptos California RG Ultra-widefield Retinal Imaging System removeOculus Easyfield Visual Field Analyzer Perimeter removeZEISS Cirrus HD OCT 4000 Quad Core OCT removeHuvitz HMB8000 Manual Blocker removeRighton BON Retinomax K-Plus 5 (Autoref Keratometer) removeIcare ic200 Tonometer For Sale remove
NameOptos California RG Ultra-widefield Retinal Imaging System removeOculus Easyfield Visual Field Analyzer Perimeter removeZEISS Cirrus HD OCT 4000 Quad Core OCT removeHuvitz HMB8000 Manual Blocker removeRighton BON Retinomax K-Plus 5 (Autoref Keratometer) removeIcare ic200 Tonometer For Sale remove
Image
SKUHD OCT 4000
Rating
Price $23,500.00 $3,200.00 $7,600.00 $3,200.00 $5,700.00 $1,870.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

DescriptionWith California, Optos has incorporated new hardware and software technology enabling practitioners to see more, discover more and effectively treat more ocular pathology thus promoting patient health.In addition to the benefits found with all of the UWF devices from Optos such as 200 degrees or up to 82% of the retina captured in a single image, in multiple modalities, as well as eyecare professionals being able to see 50% more of the retina when compared to other conventional imaging devices, California rg, offers the following benefits:– Motorized head and chin rest to more easily assist those patients requiring additional assistance during imaging– Multiple imaging modalities including; 3-in-1 color depth imaging (color, red-free and choroidal in a single image) as well as AutofluorescenceThe Easyfield perimeter is operated via an external computer (notebook or PC). You can enjoy the full freedom of networking the examination data with the familiar user interface of the OCULUS programs. The use of translucent eye shields allows you to conduct measurements without the usual eye patch, thus saving you valuable time of preparing examinations.The ZEISS Cirrus HD-OCT 4000 enable examination of the posterior and anterior of the eye at an extremely fine spatial scale, without surgical biopsy or even any contact with the eye. The Cirrus HD-OCT builds on and refines the retinal imaging technology first introduced with the ZEISS Stratus OCT™. HD-OCT stands for “high-definition optical coherence tomography.”Employing the advanced imaging technology of spectral domain optical coherence tomography, Cirrus HD-OCT acquires OCT data about 70 times faster (27,000 vs. 400 A-scans per second) and with better resolution (5 μm vs. ~10 μm axial resolution in tissue), compared to first-generation OCT technology. Cirrus acquires whole cubes of OCT image data, composed of hundreds of line scans, in about the same time as Stratus acquires a six-line scan. You can view these data cubes in three planes, or through three dimensions, giving you access to an extensive amount of retinal image data in one scan.The simplicity is another advantage Energy-saving and auto-sensing feature will surprise you White & Black colors are available 1. Compact and sleek design with luxurious feel Simple, and it makes your work environment look great 2. Adjustable LED intensity (1) Lifetime durability LED lamp (2) Easy to mark and block even with dark-tinted lenses by brightness control function 3. Auto power-saving mode (1) Automatic power off after confirming the marking points (2) Automatic power off and sleep mode after preset time Adopting high efficiency LED light source which can easily recognize dark-tinted lenses, and adjust brightness. •  Compact design, intuitive graphic, auto power on/off function.The Retinomax Series, the world’s leading handheld autorefractor and autorefractor/keratometer, delivers wide measurement range on par with table type refr, now boasts greater mobility, stability and accuracy. The Retinomax series is widely used as a global standard device for pediatric, screening, medical care in remote areas, disaster area and wide range of ophthalmic scene. Also known as: Retinomax K+, KPlus5The iCare IC200 tonometer is designed for professional use in the surgical operation room, the emergency room and also the clinic. It uses the same patented rebound measuring principle found in other iCare tonometers. There is no need for drops, air or specialised skills for its use. The IC200 gives you positional freedom with a new premium design and user interface. It allows measuring whether the patient is sitting, standing, half-sitting or in the supine or lateral recumbent position.
ContentOptos California RG Ultra-widefield Retinal Imaging System

Effectively Cure more ocular conditions

Optos introduces its newest ultra-widefield (UWF™) imaging apparatus, California, which make with specific for vitreoretinal specialists and ophthalmologists.The compact desktop device was said to provide increased imaging functionality and has introduced a new imaging modality, indocyanine green angiography, used for imaging the choroidal vasculature, which Optos said was the key in the diagnosis, management, and treatment of certain conditions such as neovascular AMD and ailments with choroidal neovascular membranes.

Why California?

With California, Optos has integrated innovative hardware and software technologies allowing professionals to see more, discover more and effectively cure more ocular pathology thus promoting patient wellness. We’re committed to further strengthening our clinical evidence while demonstrating the importance of imaging the entire retina.[su_quote cite=” Dr. David M. Brown” url=”https://houstonretina.com/David-M-Brown-MD”]”If you had another fluorescein camera, then California will fit in the same area if much smaller. It also does autofluorescence, which is helpful for evaluating geographic atrophy,”[/su_quote]New proprietary optical hardware optimizes and maintains the resolution of their optomap images throughout the scan of the retina leading to more clarity at the far periphery.Additionally, comparisons can make between different images or various dates by scrolling through all saved pictures.The Optos California directional retinal imaging apparatus makes it possible for an immediate 200-degree perspective of a patient’s eye at a single scan, supplying a high-resolution picture in under half a second. Additionally, our advanced 3D OCT scanning instrument, the Topcon Triton, has updated software making glaucoma detection and decision making much easier and stronger[su_highlight background=”#f5e791″]With optos California, an optometrist may generate over $9,000 – $15,000 a month. California Billed: $55 each picture for each single patients. Earning money every month with optos California[/su_highlight]

Features Optos California RG Ultra-widefield Retinal Imaging System

  • Compact to reduce space requirements
  • New design leads to ease of use and faster image capture
  • Non-mydriatic high-resolution imaging through many cataracts and 2mm pupils saves time in busy practices
  • Browser-based image review enables simple integration and easy access to your data from any connected pc or tablet in a HIPAA compliant environment
  • Interweaved angiography enables parallel capture of fa and icg images without manually switching between imaging modalities

Optos California is available in three models:

  • California icg

California icg design for retinal specialists to maximize management of AMD, uveitic conditions along with other choroidal pathology; it offers the following imaging modalities and image viewing options.
  • California af

California af was made to facilitate retinal tests and document findings.
  • California fa

California fa was made to help in the identification and management of diabetic eye disease and other cardiovascular ailments.Image Typeoptomap and optomap plus (red and green laser):
  • Color composite
  • green laser View
  • red laser View
  • optomap af (green laser): autofluorescence
  • optomap fa (blue laser): fluorescein angiography
  • optomap icg (infra-red): indocyanine green angiography

Oculus Easyfield Visual Field Analyzer Perimeter

KEY FEATURES – Full-fledged compact perimeter capable of performing standard automated perimetry of the central visual field up to 30° eccentricity– Designed for the combined use as visual field screener and perimeter, offering features usually available only in large units– Spherical bowl with 30 cm (11.81”) radius is enclosed into an ergonomically movable cone equipped with a distance adapted lens– Conforms to the Goldmann standard and fulfills the ISO-12866 norm for perimeters– Measurements of the Easyfield are carried out using an LED grid with 135 fixed test locations, including the common 30-2, 24-2 and 10-2 patterns– Novel SPARK test strategy leads to faster and more stable threshold tests providing improved diagnostic capabilities– Besides the standard field indices the Easyfield delivers evaluations of the innovative Glaucoma Staging Program (GSP) and the classifications provided by the Glaucoma Staging SystemADVANTAGES Oculus Easyfield Visual Field Analyzer Perimeter – Fast: Shorter examination times even for threshold tests– Compact: No completely dark room required thanks to the closed construction– Lightweight: Minimal footprint and maximal transportability– Full Threshold: The classical 4-2 dB staircase strategy using two reversals in the patient€™s answer to deliver a threshold value– Fast Threshold: Bracketing strategy using variable steps and taking advantage of already measured locations– CLIP: Strategy using stimuli with continuously increasing luminance– Threshold value is assigned the moment the stimulus is perceived– SPARK: Fast and averaged threshold strategy based on statistical correlations between threshold values measured in different locationsThe Oculus Easyfield is a compact visual field that is packed with options with a very small footprint. This system is ideal for tight spaces or a smaller practice. Easy to use and very user friendly.
 The Oculus Easyfield is an exciting compact perimeter that performs static perimetry up to 30°. It has been designed as a visual field screener and perimeter, offering features usually available only in large units. The Easyfield’s integrated bowl with a 11.81” (30 cm) radius and distance corrected lens is adapted to the Goldmann standard and fulfills the ISO-norm 12866 for perimeters. The Easyfield has a fixed point grid with 135 test locations including 30-2.

ZEISS Cirrus HD OCT 4000 Quad Core OCT

The ZEISS Cirrus HD-OCT 4000 (Cirrus HD-OCT or Cirrus) enable examination of the posterior and anterior of the eye at an extremely fine spatial scale, without surgical biopsy or even any contact with the eye. The Cirrus HD-OCT builds on and refines the retinal imaging technology first introduced with the ZEISS Stratus OCT™. HD-OCT stands for “high-definition optical coherence tomography.”Employing the advanced imaging technology of spectral domain optical coherence tomography, Cirrus HD-OCT acquires OCT data about 70 times faster (27,000 vs. 400 A-scans per second) and with better resolution (5 μm vs. ~10 μm axial resolution in tissue), compared to first-generation OCT technology. Cirrus acquires whole cubes of OCT image data, composed of hundreds of line scans, in about the same time as Stratus acquires a six-line scan. You can view these data cubes in three planes, or through three dimensions, giving you access to an extensive amount of retinal image data in one scan.Intended UseThe Cirrus HD-OCT with Retinal Nerve Fiber Layer (RNFL), Macular, Optic Nerve Head, and Ganglion Cell Normative Databases is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures.Indications for UseThe Cirrus HD-OCT is a non-contact, high resolution tomographic and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures, including cornea, retina, retinal nerve fiber layer, ganglion cell plus inner plexiform layer, macula, and optic nerve head. The Cirrus normative databases are quantitative tools for the comparison of retinal nerve fiber layer thickness, macular thickness, ganglion cell plus inner plexiform layer thickness, and optic nerve head measurements to a database of normal subjects. The Cirrus HD-OCT is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration, and glaucoma.Note: The Cirrus HD-OCT is not intended to be used as the sole diagnostic for disease.Essential Performance ZEISS Cirrus HD OCT 4000 Quad Core OCTThe Essential Performance of the instrument is to provide accurate measurements of anterior and posterior ocular structure.Patient PopulationThe Cirrus HD-OCT may be used on all adults in need of diagnostic evaluation of the eye. This includes (but is not limited to) patients with the following disabilities or challenges:• Wheelchair user • Very low or not measurable visual acuity • Fixation problems • Postural problems • Deafness • Large body, but not those above 99th percentile based on anthropomorphic dataThere is a general requirement that the patient be able to sit upright and be able to place their face in the chin and forehead rest of the instrument (with or without supplemental human or mechanical support).Cirrus HD-OCT is designed for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures.

Huvitz HMB8000 Manual Blocker

The HMB-8000 manual blocker is part of the Huvitz KAIZER series. Kaizer is the next generation to follow the Huvitz Excelon series and is designed with a wide array of features intended to simplify and perfect in-house lens finishing.The KAIZER series is truly a system like no other featuring top-of-the-line technology and unsurpassed performance. When you select the HMB-8000, you will enjoy a lifetime of LED durability. The integrated brightness control function makes it easy to mark and block any lens—even those with dark tint. The HMB-8000 blocking system is also easy to use and features intuitive graphics with outstanding functionality. With its sleek, compact design and luxurious feel, the HBM-8000 is an outstanding component of the KAIZER series.Features of the HMB-8000 Blocker ▪ Compatible with High-End Finishing Systems ▪ Adjustable LED Intensity ▪ Small Footprint ▪ Easy-to-Use ▪ Energy Efficient ▪ VersatilityKAIZER Compatible The HMB-8000 manual blocker is part of the Huvitz KAIZER series. Kaizer is the next generation to follow the Huvitz Excelon series and is designed with a wide array of features intended to simplify and perfect in-house lens finishing. The KAIZER series is truly a system like no other featuring top-of-the-line technology and unsurpassed performance.The Huvitz HAB-8000 is a one-stop solution, combining the functions of a tracer, lensmeter, and blocker in one powerful machine. Simply place the lens in position and the HAB-8000 will do the rest. The HAB-8000 is user-friendly enough for in-office use as well as robust enough for higher-volume settings. In fact, with the HAB-8000 you can process up to four jobs at the same time while connecting to up two separate edgers and a drill unit. The possibilities are endless. A 10.4-inch high-resolution touch screen monitor allows operators to control all of the system's functions. Featuring Automatic Lens Center Recognition, the HAB-8000 automatically detects the lens shape and knows what type of lens you’re using. The integrated high-performance lensmeter automatically recognizes the lens as it is set in position. Whether it’s a progressive, bi-focal, or other lens, there’s no need for marking with the HAB-8000. In addition, this high-end Huvitz model offers Digital Scan Hole Detection, Advanced 3D Tracing, Drag-and-Drop Hole Editing, Real-Time Data Transmission and so much more. Fully automated lens centering and blocking is now available at the push of a button.
Righton BON Retinomax K-Plus 5 (Autoref Keratometer)Retinomax Series, the world’s leading handheld Ref and Refract Keratometer, delivers wide measurement range on par with table type Ref, with greater mobility, stability and accuracy.The Retinomax series is widely used as a global standard device for pediatric, screening, medical care in remote areas, disaster area and wide range of ophthalmic scene.Current informatical society, eye fatigue, one of the typical modern diseases cause by eye accommodation issue is now easily discover by ACOMOREF2 series during screening basis. Accommodative Micro Fluctuation result will show in graph for easy reading, plus opacity detection function makes ACOMOREF2 the world first multi-functional Refractometer.Features:Righton BON Retinomax K-Plus 5 (Autoref Keratometer)View Finder – With view finder observation, no limit of operator age. Diopter adjustable range is +/-8D the same as Retinomax3. View finder arm angle is changeable of 0-135 degrees, making measurement easy regardless of patient’s position or posture. Adjustable diopter +/- 8D.Wider Eye Piece – Eye piece relief is 48mm from 32.2mm so that enable to look inside image while even looking at outside. No need to stick eye to the eyepiece all the time.Improved battery life – At 180 minutes, the battery capacity is now twice that of conventional modelsAutomatic Axis Compensation and Extended Measurement Range – Not only does the device let examiner know the cylinder axis angle, but it can also be automatically adjusted if it is not levelNew Child Mode – While the measurement is being taken, a melody plays continually to keep children’s attention. A constantly changing color display, both on the outside and inside target the device, also keeps children involved during the process.Even lighter and featuring an easy-to-hold gripRetinomax3 969g  →  Retinomax Screeen 960g  -9gRetinomax K-plus3 999g  →  Retinomax K+Screeen 970g  -29gREFRetinomax 5, Retinomax K+ Screeen −20D〜+23D

Icare ic200 Tonometer

The device is based on a rebound measuring principle that requires no drops, air or specialized skills for its use. The new premium design and user interface bring IOP measuring to a new level.The Icare ic200 tonometer is designed for professional use in the surgical operation room and emergency room as well as the clinic. The ic200 is fully portable, requires no anesthesia and its freedom of positioning allows measuring whether the patient is sitting, standing, half-sitting or in the supine or lateral recumbent position.A high-visibility indicator at the probe base confirms your positioning of the tonometer prior to measurement. A green light indicates measurement will be reliable, a red light indicates incorrect positioning.Features: - Effortless probe loading with the same probe as for the Icare TA01i and ic100 tonometers - The probe can’t accidentally drop from the device - Easy menu in many languages - Wireless (Bluetooth) printing and measurement transfer
  • Revolutionary design to allow for positional freedom when taking IOP measurements
  • Innovative automatic measuring sequence allows for 6 automatic measurements or single measurements to be taken with the same button
  • Intelligent positioning system for correct alignment of the tonometer
  • Powered by AA batteries
Specifications: - Dimensions : 43mm[W] x 104mm[H] x 214mm[L] - Weight : 165 g (without batteries), 260 g (with 4 x AA batteries) - Power supply : 4 x AA non-rechargeable batteries, 1.5V alkaline LR6 - Measurement range : 7 - 50 mmHg - Accuracy : ±1.2 mmHg (≤20 mmHg) and : ±2.2 mmHg (>20 mmHg) - Repeatability (coefficient of variation) : <8%Package Includes: - Icare ic200 tonometer - 4 x AA batteries - Aluminum case - IOP pad - Probe base cover - Quick guide - Screw driver - Silicone grip - Spare probe base - Instruction manual - Warranty card - Wrist strap
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: Optos California RG Ultra-widefield Retinal Imaging System $23,500.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Shopping cart close