| Description | Medit i700 makes the scanning experience a comfortable one for both the dentist and patient. Medit i700 is a fully open-source intraoral scanner, compatible with Medit’s Link software, as well as software from other CAD/CAM providers. | Providing high-quality diagnostic imaging services to your patients is high on your list of priorities. But there are limits to your budget and your space. That’s why we are excited to offer your customers the CARESTREAM DIRECTVIEW Vita CR System—a reliable, compact, tabletop imaging solution with a small footprint and light weight design. It allows seamless integration into your existing work flow, and helps increase efficiency and productivity, all at an affordable price. | New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort. | Mr Blue 2.0 is on the cutting edge of innovation – serving as a genuine ECP partner since its launch. Now featuring a whole range of new functions and even greater flexibility, Mr Blue is the perfect solution for demanding workshop. | Bison Dual ACCENTO is the unique device combination with Alexandrite laser (755nm) and Nd:YAG laser (1064nm Long pulse)
The combination of two different wavelengths makes DUAL ACCENTO a highly effective system for hair removal and pigmented lesions treatment. The 755nm penetrates deep into the skin and perfectly targets hair the follicle and absorbs melanin. | Fotona SP Specto, Nd:YAG & Er:YAG laser systemFeatures:- Highest Performance
- Gold standard Er:YAG laser and ND:YAG lasers
- Complete package Anti-Aging treatments
- Massive potential with multiple applications
- Full field and fractional scanning
- New Novel Turbo technology
- New V-smooth technology
- User friendly
- Great return on investment
|
| Content | Medit i700 intraoral scanner
The new medit i700 intraoral scanner is smaller, lighter and 2X faster than its predecessor. Summary of improvements:Hardware- Twice as fast as i500/ more vivid lifelike colors
- 18% smaller
- 12.5% lighter
- UVC light to disinfect camera internals
- Scanning area was 14×13 now 15×13
- Accuracy twice as good for full arch
- Room to room mobility with usb 3 cable connection
- 180-degree rotation on tip
- 45-degree mirror angle vs 40 – distal second molars
- Just plug right into computer for power and usb
- 100 uses for the tips autoclave vs 50
- Scans up to 70 frames per second (i500 30 frames per second)
- Remote control button – switch between scan stages / rotate without having to go back to keyboard
- Vibration when break continuity with scan
- Coverage of internal hardware
Software- Create master model from scan segments – 5 separate boxes will stitch together in segments
- Multiple bites
- Faster time to process scan
- Ortho module auto tooth segmentation
Other- Scan and produce open source .STL, .OBJ, .PLY files
- Normally delivers within 5-7 business days
- One year manufacturer warranty included (additional 2 year manufacturer warranty can be purchased at check out – Just remember, your assistant is not going to tell you s/he dropped the camera at month 13. S/He will tell you “the camera just stopped working!”)
- Includes Membership to CAD-Ray.com
- Includes Level 2 Training: two day hands-on training in Heidelberg (valid for 12 months after purchase, non-transferable)
- Includes initial remote training session
- Instructional videos to get started right away
- Peer to peer online support and private discussion forum
- Unlimited remote and phone support
- Satisfaction guarantee with return policy
- 10% restocking fee within 30 days
Full Service PackageIncludes Remote TrainingIncludes Unlimited Remote and Phone Support | Carestream Vita 25 Digital CR SystemCARESTREAM Vita Flex CR Systems are designed for small-to-midsize hospitals, clinics and practices that need compact digital solutions at an affordable price. With two options for throughput speed, Vita computed radiography systems offer in-house, high-quality digital imaging to fit your workflow. The flexible orientation makes it perfect for small spaces in offices or in mobile settings.System Beneits
Smaller size and weight
Multiple throughputs (30/45 PPH)
Ability to be positioned for horizontal or vertical feeds
Supports a number of cassette sizes
Uses Image Suite Software – easy-to-use platform
specially designed for the end userImage acquisition and management for CR and DR Systems
Image Suite V4 Software has set a new benchmark for workflow efficiency in smaller facilities. This robust software features an easy-to-use, touch-friendly interface, an enhanced set of tools, streamlined workflow and improved image quality. Our advanced “mini-PACS” module allows superb image management and analysis, and is now fully optional. Get the high-quality images you need with a system that’s a perfect fit – at very affordable price. Physical Specifications Carestream Vita 25 Digital CR System • Weight: 25 kg (55 lb) • Dimensions (W x D x H): 68.0 x 34.0 x 45.0 cm (26.7 x 13.4 x 17.7 in.) Power • Electrical Rating: 100-240 V AC 50/60 Hz • Maximum Power Consumption: 120 W • Power Consumption in Standby Mode: 42 W • Power Supply Conditions: AC Power 100~240 V AC,50/60 Hz, 1.5 A Kodak/Carestream Vita25 CR System:25 Plate Per Hour Reader
2, 14×17 Cassettes
PC, Keyboard, Monitor, & Mouse
Genesis Software
2 Year Warranty
Available with the following upgrades:PACS: 250GB & 2 Viewers
PACS: 450GB & 4 Viewers
Go from 25 to 45 Plates Per Hour
Additional 14×17 Cassettes
Additional 10×12 Cassettes | Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
The Laser uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IOptima-518-Classic Active Optical Systems Optima 518 IPL LaserThe Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. | Essilor Mr Blue 2.0 Lens Edgers and TracerComplete Control of Lens Mounting
- Optimal monitoring of all trajectories, irrespective of finishing materials or shapes
- Absolute axis control thanks to hybrid edging technology: grinding + milling
- Ideally suited for quality finishing even on highest base curves
- Fast and accurate drilling with data acquired in a single operation
- Automatic centering and blocking for simple operation
Unrivalled Ergonomics- Completely integrated functions without external peripheral devices
- Vertical architecture with <Heads-up displays> for optimum comfort
- Storage features ensure all accessories are within reach.
- Intelligent interface adapts to the way you work.
Highest Quality Guaranteed Essilor Mr Blue 2.0 Lens Edgers and TracerPerfect Centering- Binocular 3-D tracing of full-rim frames up to base 9*
- Automatic adjustment of centering data based on the frames’ 30D parameters*
Aesthetic and Robust Mountings- FIT-4-Frame technology with dedicated small wheel*
- Drilling and grooving tools can be tilted up to 30o, making it safe to mount lenses of up to base 10. *Essilor patents and exclusives
Safe Process- Roughing cycle automatically adapts to the curves of lenses up to base 10, avoiding all risk of breakage
- Bevel placement and shelf depth optimized for safe mounting without undue stress of lens
Aesthetically Pleasing and Easy-to-Mount Bevels- The bevel heights are adjustable to perfectly adjust to the thinnest grooves
- The shelf bevel heights are optimized to follow the frame’s shape perfectly
- The step bevel is particularly suited for sport eyeglasses with deep, rectangular or uneven groove profile
Mr Blue 2.0 is on the cutting edge of innovation – serving as a genuine ECP partner since its launch. Now featuring a whole range of new functions and even greater flexibility, Mr Blue is the perfect solution for demanding workshop. | Bison Dual ACCENTO Nd YAG Laser
Bison Dual ACCENTOBison Dual ACCENTO is the unique device combination with Alexandrite laser (755nm) and Nd:YAG laser (1064nm Long pulse)
The combination of two different wavelengths makes DUAL ACCENTO a highly effective system for hair removal and pigmented lesions treatment. The 755nm penetrates deep into the skin and perfectly targets hair the follicle and absorbs melanin.The Dual Accento combined laser system is indicated for the following: 755 nm Long Pulsed Alexandrite Laser Temporary hair reduction. Stable long-term or permanent reduction through targeting of melanin in hair follicles. Treatment of bening pigmented lesions. Treatment of Wrinkles.The photocoagulation of dermatological vascular lesions (such as port of wine stains, hemangiomas, telangiectasis) 1064nm Long pulsed Nd:YAG laser. The removal of un-wanted hair reduction, for stable long term or permanent hair reduction and for treatment of PFB to all skin types Fitzpatrick I-VI including tanned skin.Pigmented lesions to reduce lesion size and patients with lesions. Reduction of red pigmentation in hypertrophic and keloid scars where vascularity is integral part of scar, treatment of wrinkle. Permanent hair reduction is defined as the long term, stable reduction in the number of hairs re- growing when measured at 6,9, and 12 months after the completion of treatment regime.The Dual Accento performs with high efficacy of the pigmentation problems without damaging tissue structures adjacent to the pigment. The wavelength of 1064nm Nd: YAG long pulse rejuvenates the skin by stimulating the collagen layer of the dermis and effectively treats vascular lesions and is appropriate for all skin types when used for hair removal.Bison Dual ACCENTO 1064nm NdYAG Laser With 755nm Alexandrite Laser
Bison Dual ACCENTO 1064nm NdYAG Laser with 755nm Alexandrite Laser is the unique device. Combining 755nm Long pulsed Alexandrite and 1064nm Long pulsed NdYAG Alexandrite 755nm long pulsed wavelength. Due to the high melanin absorption is effective for hair removal and pigmented lesions treatment. NdYAG 1064nm long pulsed wavelength rejuvenates skin by stimulating the dermis layer, effectively treating vascular lesions. | Fotona SP Spectro Laser System
Fotona’s new SP Spectro laser generator is the laser a multi-application laser for every budget. The powerful and easy to use Fotona SP Spectro draws together two of the gold standard lasers for the cosmetic and aesthetic market high performance Er:YAG and Nd:YAG in one unique and affordable package. The Fotona XP Spectro is the laser system of choice to provide multi applications without the capital cost of multiple laser systems.Features:- Highest Performance
- Gold standard Er:YAG laser and ND:YAG lasers
- Complete package Anti-Aging treatments
- Massive potential with multiple applications
- Full field and fractional scanning
- New Novel Turbo technology
- New V-smooth technology
- User friendly
- Great return on investment
An Affordable multi-application platformThe Fotona SP Spectro offers you the client with the most dependable, affordable up to date most complete package for aesthetical and surgical treatments. It has exceptional functionality and performance despite its relatively low price tag. The Fotona SP Spectro has enhanced treatments attributes coupled with fully customizable settings offering 3rd generation Er:YAG skin resurfacing. The Fotona SP Spectro can be customised and used on any skin type for both full field and fractional resurfacing by absolute control over ablation and coagulation. The Fotona SP Spectro comes complete with state-of-the-art scanners and fractional options which make the system fully loaded and a comprehensives solution to any laser practice whether new or old. Fotona’s unique TURBO technology offers high-definition fractional treatments and Fotona’s V-smooth technology offers a high-speed, minimally –ablative coagulation which further adds to the Spectro’s treatment dimensions. Using the Spectro wide functionality makes you the practitioner an artiste to be able to mix and match cold ablation and thermal effects to achieve the very best of results.The ideal tool for Non-ablative treatmentsThe mainstay for many aesthetic and cosmetic practices is still non-ablative treatments and for this the ND:YAG application of the Fotona SP Spectro is invaluable and needs no introduction as the gold standard treatment. The new SP Spectro also features as standard the innovative and acclaimed S-11, 42cm2 area scanner and support top-hat distribution hand pieces for impressive results in laser hair removal, acne, vascular treatments and of course skin rejuvenation. Also as standard for the more challenging skin types and structures is Fotona’s own FRAC3 modality. This is a fractional approach that supplies non-ablative effects in the skin with minimal damage to the surrounding skin and tissue which results in superior treatments and quicker recovery time.Anti-aging platformThe Fotona SP Spectro also has option for QCW Nd:YAG which will allow you to combine both ablative and non-ablative techniques with lucrative surgical treatments to maximise the return on your investment. The minimally invasive treatments such as laser assisted lipolysis, laser assisted hyperhidrosis and endovenous laser ablation can become a valuable part of your treatment portfolio with this unique laser system and in essence offer a complete anti-aging make over, from the inside out.Er:YAG and Nd:YAG; what a combination!Er:YAG energy is highly absorbed in water which is the main target chromophore for skin rejuvenation and leads to micro-level precision for skin vaporization making the SP Spectro very efficient with little thermal conduction. The results of this advanced performance is side effects are kept to a minimum with little hyperpigmentation or erythema and a fast recovery time. Variable square pulse technology can be maximised with the SP Spectro as it can be accurately tuned to vary the ratio of cold ablation and non-ablative thermal effects to best suit the needs of the patient.The ND:YAG complements the Er:YAG lasers ablative action with the ability to penetrate deeper into the skin without risking damage to the skin surface. The homogenous absorption in skin allows the functionality to be used on all skin types. . The SP Spectro’s Nd:YAG variable square pulse technology causes an increase in the target areas temperature whilst having little or no effect on the surrounding tissue.Maximising potential- The Fotona SP Spectro has inbuilt systems in place to make it one of the best value for money laser systems currently on offer with:
- VSP technology – A square pulse eliminating needless energy to the skin
- EFC – Energy feedback control – Checking and controlling each pulse of laser energy, ensuring the output is exactly matched for a safe and effective treatment avoiding uncontrolled energy fluctuations
- Turbo Technology – A rapid sequence of identical pulses at the same spot, enhancing ablation depth whilst creating more sharply defined, high definition micro channels maximising the effects of even the most conservative Er:YAG treatment settings
- V Smooth Technology – High coagulation, minimally ablation technology. A computer controlled setting that irradiates individual spots for an optimum time before retreating at optimum interval levels
- F Runner ER:YAG Scanner – A computer controlled scanner that delivers sharp fractional treatments with absolute precision and accuracy
- S-11 Scanner – a 42cm2 scan area with an integrated cooling attachment to ensure large area treatments with maximum patient and practitioner comfort
- S Runner Er:YAg Scanner – 4mm spot size and 16cm2 area of treatment for full field resurfacing with adjustable scan areas and patterns
- Tissue Effect indicator – This shows the balance between ablative and coagulation allowing you to estimate the nature of the treatment and predict the outcome of the treatment.
Key Treatments - Verrucae treatments
- Laser Hair removal
- Rosacea treatments
- Fine wines and Wrinkles
- Laser peels
- Acne treatments
- Skin Rejuvenation
- Scar revision
- Laser assisted lipolysis
- Laser assisted Hyperhidrosis
- Onychomycosis
- Fractional treatments
- Skin tightening
- EVL
- Vascular legions
- Thread veins
- FRAC3
- Pigmentation
Technical Data Fotona SP Spectro Laser System| Er:YAG laser |
|---|
| Laser wavelength: | 2940 nm | | Max. pulse energy: | 3000 mJ | | Max. average power: | 20 W | | Pulsewidth: | MSP Mode: 100 microseconds | | SP Mode: 300 microseconds | | LP Mode: 600 microseconds | | VLP Mode: 1000 microseconds | | XLP Mode: 1500 microseconds | | SMOOTH mode: 250 miliseconds (with equally-spaced SP pulses) | | V-SMOOTH mode with S-Runner Scanner: 100-500 ms | | Max. frequency: | 50 Hz | | Manual spotsizes: | 0.45 to 12 mm | | Scanner spotsize: | F-Runner: 250 μm, S-Runner: 4 mm | | Max. scanner area: | F-Runner: 168 mm², S-Runner: 1600 mm² | | Scanner coverage: | F-Runner: 5% – 20% | | Scanner overlap: | S-Runner: 0% – 30% | | Scanning sequences: | F-Runner: OPtimal, NAtural | | S-Runner: SEquential, OPtimal, PaRtial | | Beam delivery type: | FeatherLight arm |
| Nd:YAG laser |
|---|
| Laser wavelength: | 1064 nm | | Max. average power: | 35 W | | Pulsewidth range: | PULSE: 0.1 to 50 ms, QCW: 0.1 to 2 ms | | Max. frequency: | PULSE: 75 Hz, QCW*: 100 Hz | | Manual spotsizes: | 2 to 10 mm | | Scanner spotsizes: | 3 mm*, 6 mm, 9 mm* | | Scanner area: | 42 cm² | | Beam delivery type: | Optical fiber |
|