| Description | Medit i700 makes the scanning experience a comfortable one for both the dentist and patient. Medit i700 is a fully open-source intraoral scanner, compatible with Medit’s Link software, as well as software from other CAD/CAM providers. | Recommended for all skin types, the PicoGenesis laser procedure is used to treat:• Brown spots
• Sun damage
• Age spots
• Melasma
• Hyperpigmenation
• Pigmented lesions | Ezer ERK-7800 Auto Refractor/KeratometerConfidently measure the human eye with a sophisticated cutting edge technology designed to enhance your ability to diagnose ocular errors faster, easier, and accurately. Ezers ERK-7800 is brilliantly designed technology measures the eye with ultra precision and speed to provide reliable data as the starting point of your refraction and contact lens fitting. It’s compact and modern design enables seamless operation and an enhanced patient comfort, making it the ideal choice in for any ophthalmic practice. Backed by an industry leading 2-years warranty! | InMode Aesthetics InmodeRF BodyTite with BodyTite and FaceTite ApplicatorsBenefits
Controls heating to ensure that large volume contraction is consistent, avoiding overtreated or undertreated area
When treating different areas of the body, the operator is always receiving real time temperature monitoring, even in deep fat areas where laser temperature readers cannot reach
Allows focal treatment of all body areas with large volume
Treats deep fat, up to 50 mm (2 inches) | workflow, because some letters inspire confidence.With Neksia, Essilor combines years of experience in high-performance and precision edging into one of the most user-friendly and productive systems in the world. | New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort. |
| Content | Medit i700 intraoral scanner
The new medit i700 intraoral scanner is smaller, lighter and 2X faster than its predecessor. Summary of improvements:Hardware- Twice as fast as i500/ more vivid lifelike colors
- 18% smaller
- 12.5% lighter
- UVC light to disinfect camera internals
- Scanning area was 14×13 now 15×13
- Accuracy twice as good for full arch
- Room to room mobility with usb 3 cable connection
- 180-degree rotation on tip
- 45-degree mirror angle vs 40 – distal second molars
- Just plug right into computer for power and usb
- 100 uses for the tips autoclave vs 50
- Scans up to 70 frames per second (i500 30 frames per second)
- Remote control button – switch between scan stages / rotate without having to go back to keyboard
- Vibration when break continuity with scan
- Coverage of internal hardware
Software- Create master model from scan segments – 5 separate boxes will stitch together in segments
- Multiple bites
- Faster time to process scan
- Ortho module auto tooth segmentation
Other- Scan and produce open source .STL, .OBJ, .PLY files
- Normally delivers within 5-7 business days
- One year manufacturer warranty included (additional 2 year manufacturer warranty can be purchased at check out – Just remember, your assistant is not going to tell you s/he dropped the camera at month 13. S/He will tell you “the camera just stopped working!”)
- Includes Membership to CAD-Ray.com
- Includes Level 2 Training: two day hands-on training in Heidelberg (valid for 12 months after purchase, non-transferable)
- Includes initial remote training session
- Instructional videos to get started right away
- Peer to peer online support and private discussion forum
- Unlimited remote and phone support
- Satisfaction guarantee with return policy
- 10% restocking fee within 30 days
Full Service PackageIncludes Remote TrainingIncludes Unlimited Remote and Phone Support | Cutera Enlighten III Pico-Nano Second Tattoo RemovalThis next-generation PicoGenesis laser is an advanced, non-thermal way to treat pigmentary concerns, PicoGenesis harnesses a non-thermal, photomechanical effect paired with ultra-short—one trillionth of a second long—pulse durations. The perfect blend of technologies creates shockwaves that shatter pigments in the skin without damaging the surrounding tissue, while inducing dermal disruption and remodelling for true skin revitalisation.Unlike conventional laser toning that requires up to 15 treatment sessions and often lead to adverse side effects such as redness, swelling and itching. Thanks to the incorporated picosecond technology, in as few as three sessions you will experience a dramatic improvement in the reduction of pigmentation as well as a brighter, more uniform complexion in just 20 minutes—and all with no downtime! With entirely changeable parameters, this game-changing treatment an be used to benefit even the most challenging skin concerns, and can also effectively remove all colours of tattoos.Recommended for all skin types, the PicoGenesis laser procedure is used to treat : Cutera Enlighten III Pico-Nano Second Tattoo Removal• Brown spots
• Sun damage
• Age spots
• Melasma
• Hyperpigmenation
• Pigmented lesionsenlighten III combines multiple wavelengths (1064 nm, 532 nm and 670 nm) and picosecond + nanosecond pulse durations (750/660 ps + 2 ns) in a single platform for the treatment of unwanted multicolor tattoos, epidermal and dermal pigment, and skin revitalization across all skin types. Unlike conventional laser toning that require up to 15 treatment sessions and often lead to unpredictable results, PICO Genesis harnesses the power and flexibility of enlighten SR combined with its technical benefits in a dual delivery procedure to selectively shatter pigment and induce dermal disruption and remodeling for true skin revitalization in fewer than 3 sessions.“The enlighten laser system has been a game changer for my tattoo removal practice. I feel much more confident that we can deliver patients the results they have been wanting since laser tattoo removal was first invented.” | Ezer ERK-7800 Autorefractor KeratometerFeatures of the ERK-7800 Auto Refractor/Keratometer
Auto Refractor/Keratometer
Enhanced Retro-illumination Imaging
Accurate Measurement of Iris & Pupils Diameters
Precise Temperature Sensor Compensation
Enhanced Measuring Speed
Comfortable Motorized Chin Rest
Automatic High Speed Cutting Printer
Simple One Touch Lock Knob
20 Touch & Tilt Color Monitor Display
Sophisticated TFT LCD Graphic User Interface
Easy Network Capability
Backed by an Industry Leading 2-years Warranty!
Auto Refractor/Keratometer
The ERK-7800 instantly reports the patient’s assessed eye power by combining the Auto Refractor/Keratometer functions into this one sharp instrument, making measurement a snap. This determines the refractive and keratometric properties of the human eye to assist eye care professionals in the process of prescribing corrective eyeglasses and contact lenses. Keratometry and Refractometry (RK Mode) Enhanced Retro-illumination Imaging Ezer ERK-7800 Autorefractor Keratometer
With the Enhanced Retro-illumination Imaging capability in the ERK-7800, you can treat and see abnormal crystalline lenses, cataracts, and scratches of corneas helping you to determine how healthy the patients eyes are with better clarity. This allows for observation of the eye condition of the cataract or contact lens surface. The system saves up to 2 images of each eye. Accurate Measurement of Iris & Pupils Diameters
The corneal diameter and base curve of contact lenses can be measured with this one instrument. Therefore, measurements of eye and prescriptions for glasses and contact lenses can be made more efficiently. Measuring Cornea Size (SIZE MODE) Wide Dioptric Measurement Range
Because the ERK-7800 covers a wide measurement range from -25D to +22D, even an examinee with strong myopia can be measured.
Enhanced Measuring Speed
Specially designed image chips have succeeded to make REF measuring speed faster reducing the overall examination time and increases throughput for complete examinations. Comfortable Motorized Chin Rest
Simply by pressing up/down buttons, user can set the height of measuring point comfortably. With the cutting edge auto sensor mechanism, you can track down, measure and focus the eye with out ever making a mistake. Automatic Printer Paper Cut
The printer is designed to execute, print, & cut data automatically at high speed for immediate results. Simple One Touch Lock Knob
With just the touch of a single button, the main body can easily be locked to its base. 20 Degrees Tilted LCD Monitor
The LCD Monitor tilts up to 20 degrees; a design made for comfort making. Excellent ergonomics makes it possible to operate the ERK-7800 while standing or sitting, for added convenience. Sophisticated TFT LCD Graphic User Interface
Sharp images with easy to understand icons make this 6.4-inch color TFT LCD interface user-friendly and enjoyable to work with. | INMODE Bodytite Laser – Radio Frequency (RF)BodyTite
Cannula Length:17 cm
Cannula Diameter:2.2 mm
Depth of Treatment:Up to 50 mm (2)
Internal Temperature:Operator adjustable between 50°C – 70°C
External Temperature:Operator adjustable up to 42°C
Output Temperature:1 MHz+
FaceTite
Cannula Length:10 cm
Cannula Diameter:1.3 mm
Depth of Treatment:Up to 25 mm (1″)
Internal Temperature:Operator adjustable between 50°C 70°C
External Temperature:Operator adjustable up to 42°C
Output Frequency:1 MHzBodyTite WorkstationMinimally Invasive Radio-Frequency Assisted Lipolysis (RFAL) Surgical Results Without the Scars.BodyTite is InModes latest minimally-invasive body contouring procedure that provides superior internal and external lipolysis, delivering results only achieved through more extensive excisional surgical procedures. BodyTite is powered by RFAL (Radio-Frequency Assisted Lipolysis) resulting in three-dimensional remodeling.BodyTite provides doctors with a tool to perform arm lifts without excisions, breast lifts without the lollipop scar and contour areas of non-adherence with results previously only achieved through more extensive surgical procedures.Benefits
Controls heating to ensure that large volume contraction is consistent, avoiding overtreated or undertreated area
When treating different areas of the body, the operator is always receiving real time temperature monitoring, even in deep fat areas where laser temperature readers cannot reach
Allows focal treatment of all body areas with large volume
Treats deep fat, up to 50 mm (2 inches)PATIENT BENEFITS
Patients today want to avoid surgery when possible. With BodyTite and FaceTite, your patients can reduce fat without leaving behind saggy, wrinkly skin. They are left with surgical-like results with no scars, less downtime and long-lasting, beautiful results.PRACTICE BENEFITS
Adopting RFAL with three-dimensional skin contraction can help innovate your practice. Leveraging BodyTite and FaceTite for your practice allows you to add a suite of minimally invasive procedures that contours and lifts abdominal, breast, face, neck, arm, thigh and knee tissue.FaceTite
HOW DOES IT WORK
FaceTite is a minimally-invasive contouring solution for the face and small areas of the body. Physicians can achieve results similar to a facelift or brachioplasty without excisional surgery. This is a safe, effective and exciting treatment that offers patients significant aesthetic changes.FaceTite is powered by RFAL (Radio-Frequency Assisted Lipolysis) and provides superior internal and external lipolysis, resulting in three-dimensional remodeling of the fibrous septa. Built-in safeguards including real time measurements of skin temperature, impedance monitoring, power cut-off and audible feedback help ensure patient safetyBenefits INMODE Bodytite Laser – Radio Frequency (RF)
Uniform thermal field provides an even distribution of heat.
Dual temperature technologies provide greater safety and control compared to other technologies.
100% energy concentration in the treatment zone.
Physician sets and controls the temperatures. Heat gradient enables optimal treatment results.AccuTite
ACCURACY IS EVERYTHING
PRECISION TARGETING AND PROVEN PERFORMANCE
ACCURACY IS EVERYTHING
The new AccuTite makes focal RF contraction without excisional surgery the new standard in cosmetic medicine. Small, but mighty, the AccuTite delivers precision heating in addition to the science and safety recognized with the Radio-Frequency Assisted Lipolysis (RFAL) family of technologies.
FOR FACE AND BODY
FACEBrow
Periorbital
Nasolabial Fold
Lower Face
Neck
BODYAxilla Bra Fat
Upper Arms
Hands
Abdomen Etching
Inner Thigh
Knees
Womens Health & WellnessSIMPLE, SAFE & FOCUSED
The AccuTite is the smallest minimally-invasive radio-frequency contraction device with the most number of clinical studies and peer-reviewed publications backing its safety and efficacy. Patients who need precision fat reduction or skin contraction now have a new solution that can be done under local anesthesia, in an office setting, in less than 20 minutes, without excisional surgery. | Essilor Neksia Lens Edging SystemWork More Easily- A touch of efficiency – The 8.4-inch color touch-screen display makes navigation a breeze. And you can select the icon-based functions quickly and easily with just the touch of a finger.
- Fast-access settings – With all job settings located conveniently on the centering part of the system, you can define your finishing settings quickly and launch edging jobs in just a few clicks. If necessary, you can still adjust settings after the feeler measurement.
- A user-friendly 1,000-position job database – Save precious time by easily accessing or storing complete jobs in the database via the touch screen or optional barcode reader.
Experience Workflow Efficiency- Fast, easy and extended frame tracking – Equipped with auto frame-type selection, simple clamping and rapid tracing cycles, Neksia helps you trace any type of frame effortlessly, including children’s frames, small B-size and large A-size frames
- Automatic drilling-hole recognition – Achieve even greater productivity thanks to optional features dedicated to automatic detection of drilling holes and flat bevel shapes.
- Convenient centering and blocking – Neksia arms you with valuable features that make centering and blocking straight-forward and precise.
- Handle lenses easily with the wide-open centering area
- Increase precision with intelligent targeting and parallax-free working
- Benefit from the intuitive on-screen interface
Achieve High Performance Essilor Neksia Lens Edging System- Improve axis accuracy – By combining new edging cycle algorithms and cutting-force regulation, you are guaranteed optimal results whatever the edging situation.
- Optimized edging speed based on the lens material, shape and lens thickness guarantees fast cycle times, lens positioning and alignment.
- The New Edging Assisted System cycle avoids axis deviation on new- generation hydrophobic lenses, rectangular shapes or fragile lenses.
- Best automatic cycles – For 90% of your jobs, all it takes are a few clicks to achieve a perfectly calculated bevel, groove or drilling cycle. The lens is well positioned for an aesthetic and perfectly fitted result, no matter the material or frame type.
- Consistent intelligent chamfering – With Neksia’s patented flexible chamfering wheel, the pressure applied to the wheel adapts seamlessly to the lens edge depending on the shape and curve of the lens.
| Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
The Laser uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IOptima-518-Classic Active Optical Systems Optima 518 IPL LaserThe Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. |
Reviews
There are no reviews yet.