Air Cooling Mode Provides Improved Patient Safety and Comfort
Patented PISA Technology for the Best Treatment Outcomes
Reduction of thigh and arm circumference
Reduction of flanks
Pain relief in patients with knee osteoarthritis
The easy and comfortable way to reduce adipocytes through non-contact apoptosis-inducing radiofrequency. Utilising a specialised frequency combined with the ideal 300 Watts of power to selectively target and heat adipocytes to the optimal temperature to cause denaturation of cells.
Provide care for patients with a device that is not only easy for you to operate and is relaxing for them. The easy to use touch screen interface combined with the ergonomic articulating arm has multiple joints that provide extended reach and the air flow head conforms to most body types.
HOW IT WORKS FOR REDUCTION FOR WAIST CIRCUMFERENCE
The apoptosis-inducing radiofrequency penetrates deep into the tissue, targeting the adipocytes. The adipocytes are super excited and oscillate rapidly causing frictional heat. The frictional heat raises the adipocyte temperature to 45 degrees at which point the cells denaturise. This denaturation causes changes in the integrity of the adipocyte membrane, which leads to apoptosis (cell death), with expulsion of the intracellular lipid. The body’s natural removal process then takes over, permanently removing the damaged cells.
WHAT SETS enCurve APART?
Destroys fat cells while protecting epidermis and dermis
Two applicators for variety of treatment options including abdomen, thigh and arm
Customise treatments with Personalised Impedance Synchronisation Application technology (PISA)
Safely leave patient unattended during most of the treatment minimises staff time
Easy to install and operate
No consumables
300 Watts deliver ideal power for optimal treatment outcomes
Air Mode works to eliminate sweat on tissue to prevent risk of burn
The enCurve synchronises treatment energy with the change in the patient’s impedance in order to minimise energy loss and achieve a better clinical outcome. PISA technology overcomes shortcomings of traditional RF device.
COMPARISON OF TREATMENT MODALITIES IN BODY CONTOURING
The enCurve easily treats the entire abdomen and waist line for a more natural appearance and provides full coverage, while most competitors do not.
Reviews (0)
Reviews
There are no reviews yet.
Be the first to review “Lutronic enCurve – Non-Contact RF Fat Reduction For Sale” Cancel reply
The Easy, Comfortable Way To Deliver Circumferential Reduction
Creating Great Curves
Perfect Frequency to Destroy Adipocyte Cells
Air Cooling Mode Provides Improved Patient Safety and Comfort
Patented PISA Technology for the Best Treatment Outcomes
Reduction of thigh and arm circumference
Reduction of flanks
Pain relief in patients with knee osteoarthritis
The Extra – 818 is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features:
* Contemporary touch screen control
* Built-in Patch Test procedure for examining the optimal energy level
* A stunning number of 450,000 flashes in both lamps.
* The Large Handpiece has a Push Button in addition to the Foot Switch making
work easier and faster for the therapist.
Cutera Xeo LaserMultiple Technologies, Maximum FlexibilityIn today’s fast-paced aesthetic practices, maximum flexibility and upgradeability are paramount. Whatever your need, the Cutera Xeo Laser can provide the most versatile laser and light technologies on the market today. Whether you are interested in, Skin Fitness, hair removal, vascular therapies – or all the above – the Xeo can accommodate your specific needs through our upgradeable platform.The Cutera Xeo Laser combines the proven effectiveness of Cutera’s long-pulse Nd:YAG laser technology with the next generation of pulsed light treatments. The Cutera XEO can offer permanent hair reduction on all skin types, a complete range of vascular treatments and the next-generation in non-ablative combination skin therapy.
Energist NeoGen PSR offers a range of treatment options, and delivers the unparalleled results your patients expect: The unique energy delivered by NeoGen is non fractionated and not dependant on a chromophore for its uptake. This provides uniform energy absorption, ensuring consistent treatment of the skin, and at high energies supporting significant tightening.
The ability to work specifically in the deep dermis, without damaging the epidermis, is regulated in the RF Secret by the delay time of fractional radiofrequency. The needles are inserted at a rate of milliseconds equal to a stamping process in the skin and also withdrawn immediately. Only after the needles are penetrated into the desired skin layer, is carried out for a few milliseconds, a radio frequency pulse to set heat damage. While the penetration into the skin, the needles remain always cold. In order to achieve a deep and superficial effect, the needle depths can be varied individually in the respective treatment passes.
Air Cooling Mode Provides Improved Patient Safety and Comfort
Patented PISA Technology for the Best Treatment Outcomes
Reduction of thigh and arm circumference
Reduction of flanks
Pain relief in patients with knee osteoarthritis
The easy and comfortable way to reduce adipocytes through non-contact apoptosis-inducing radiofrequency. Utilising a specialised frequency combined with the ideal 300 Watts of power to selectively target and heat adipocytes to the optimal temperature to cause denaturation of cells.
Provide care for patients with a device that is not only easy for you to operate and is relaxing for them. The easy to use touch screen interface combined with the ergonomic articulating arm has multiple joints that provide extended reach and the air flow head conforms to most body types.
HOW IT WORKS FOR REDUCTION FOR WAIST CIRCUMFERENCE
The apoptosis-inducing radiofrequency penetrates deep into the tissue, targeting the adipocytes. The adipocytes are super excited and oscillate rapidly causing frictional heat. The frictional heat raises the adipocyte temperature to 45 degrees at which point the cells denaturise. This denaturation causes changes in the integrity of the adipocyte membrane, which leads to apoptosis (cell death), with expulsion of the intracellular lipid. The body’s natural removal process then takes over, permanently removing the damaged cells.
WHAT SETS enCurve APART?
Destroys fat cells while protecting epidermis and dermis
Two applicators for variety of treatment options including abdomen, thigh and arm
Customise treatments with Personalised Impedance Synchronisation Application technology (PISA)
Safely leave patient unattended during most of the treatment minimises staff time
Easy to install and operate
No consumables
300 Watts deliver ideal power for optimal treatment outcomes
Air Mode works to eliminate sweat on tissue to prevent risk of burn
The enCurve synchronises treatment energy with the change in the patient’s impedance in order to minimise energy loss and achieve a better clinical outcome. PISA technology overcomes shortcomings of traditional RF device.
COMPARISON OF TREATMENT MODALITIES IN BODY CONTOURING
The enCurve easily treats the entire abdomen and waist line for a more natural appearance and provides full coverage, while most competitors do not.
Active Optical Extra 818 IPL Skin Rejuvenation & Hair RemovalHandpieces:Integrated dual handpieces
Chilled Tip:Up to 4c
Pulse Interval:0.5-2 Seconds
Output Power:11-31 joulse/cm2, upto 4,000W
Cooling System:Revolutionary dual cooling
Control:Intuitive touch screen control
Lamp’s Life Span:250,000 Flashes (Universal) 200,000 Flashes (Facial)
Treatment Area:4.5 cm2 (15*50mm) Universal, 4.5 cm2 (15*30mm) Facial
Wavelength:420-100 nm
Weight:42Kg (including Stand)
Dimensions:44cm x 45cm x 100cmExtra-818 Active Optical Extra 818 IPL Skin Rejuvenation & Hair Removal
The Extra – 818 is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features:
* Contemporary touch screen control
* Built-in Patch Test procedure for examining the optimal energy level
* A stunning number of 450,000 flashes in both lamps.
* The Large Handpiece has a Push Button in addition to the Foot Switch making
work easier and faster for the therapist.The Extra – 818, based on Active’s GEM-PL technology, sets sets a specific Pulse Pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth.
The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.The combination of tested treatment protocols with high end engineering makes the Extra – 818 the perfect device for leading clinics.Revolutionary Cooling System
The Extra – 818 has a dual cooling system, controlled and monitored in order to ensure long lifetime to the lamp and a comfortable treatment to the patient.Competitive cooling systems “freeze” the skin so that during the treatment the skin temperature will rise to a bearable level. However, this “freezing” temperature might limit the results because the follicles will not reach the coagulation temperature. To ensure optimal results Active installed a special Processor that prevents overcooling the skin and maintains a uniform low temperature of the “glass” throughout the treatment. This revolutionary system enables the Extra – 818 to provide best results with optimal patient comfort.Research Program
For clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device.
The energy levels in the self setting program can reach 31Jcm2 with high intensity of 4,000W.
Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERr uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IActive Optical Systems Optima 518 IPL LaserOptima-518-Classic
The Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERNew Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD.
Cutera Xeo with Full Nd Yag and Low PulsesCutera Xeo Laser HandpiecesPearl Fractional Handpiece Features
Pearl Fractional has deep ablation and controlled thermal zone delivers maximum single-treatment results with less patient discomfort, downtime and risk than CO2
Indicated for moderate to severe photoaging
The 2790 nm wavelength (YSGG) controls thermal damage to maximize ablation while maintaining thermal stimulation and coagulation
Controlled thermal zone minimizes risk of PIH and other complications
Single treatment results are possible because our large 300 micron spot size ablates enough tissue in one pass
Wound healing causes increased fibroblast activity and long term collagen deposition. Improvement is realized over six month period.
CoolGlide Nd Yag Laser Handpiece Features and SpecificationsThe CoolGlide laser is the first laser cleared for permanent hair reduction in all skin types.
Treat all skin types (I-VI) including tanned skin in the summer
Patented PowerFlex™ technology provides fast treatments and high efficacy; allows independent control of fluence, pulse duration and repetition rates to tailor your treatment parameters
Copper cooling provides the most efficient method of cooling for optimal skin protection and comfort
Large spot size (10 mm) for maximum speed and optimal penetration at all follicle depths
Wavelength: 1064 nm
Fluence / Energy: Up to 300 J/cm2
Spot Size: 3 mm, 5 mm, 7 mm, 10 mm
Pulse Width: 0.1 – 30 msec or 10 – 100 msec
Repetition Rate: 2 Hz to 10 Hz
Laser Genesis Handpiece FeaturesLaser Genesis is a staple of skin care for every doctor’s practice. It is a multi-purpose, all season, all skin type solution for overall skin health
Cutera Xeo Laser has a 1064 nm wavelength, combined with our patented microsecond technology, protects the epidermis, targets microvasculature and stimulates collagen production
Improves wrinkles by gently heating the dermis; corrects diffuse redness, rosacea; smooths skin texture, shrinks pore size
Peer reviewed journal shows evidence of erythema reduction and new collagen formation in the papillary dermis (Archives of Dermatology, Nov 2004)
No downtime, minimal discomfort, no disposables.
LimeLight Handpiece Features and SpecificationsLimeLight is the most versatile, programmable device for treating vascular and pigmented lesions.
Three distinct preset programs (520-1100 nm) provide excellent hemoglobin and melanin absorption for uniform treatments and ease of use
Clinical versatility permits treatment of multiple indications, including both low and high contrast pigmentation
Features such as the industry’s fastest treatment speed and adjustable temperature control provide clinical versatility
Only company with real-time calibration; this ensures accurate and consistent power output during treatment for reproducible results and patient safety
Program A – 520 nm Filter – Fine Telangiectasia
Program B – 560 nm Filter – Telangiectasia, Pigment
Program C – 580 nm Filter – Solar Lentigines
Spot Size: 10 mm x 30 mm
Cooling: 5 °C, 10 °C or 20 °C
Fluence / Energy: 5-30 J/cm2
Repetition Rate: 2 Hz
AcuTip Handpiece FeaturesAcuTip delivers optimal results with targeted focal treatments of pigmented and vascular lesions–with no risk to surrounding skin.
Small tip allows aggressive pinpoint treatments – without compromising safety
Selective wavelengths (500-635 nm) with short pulse durations deliver a powerful focal treatment
Ideal for treatment of both low and high contrast pigmented lesions
As powerful as Q-switched lasers for epidermal pigmentation; low risk of associated PIH
Pearl Handpiece FeaturesPearl delivers superior results in fewer treatments with less patient downtime than with non-fractional ablative lasers.
Indicated for fine wrinkles, dyschromia, skin tone and texture
Full epidermal renewal is achieved with YSGG’s 2790 nm wavelength
Patients receive 1-2 treatments without weeping and oozing and recover in 3-4 days
Excel Handpiece FeaturesThe first clinically effective long-pulsed Nd:YAG laser for both facial and lower extremity vascular lesions.
The Excel safely and effectively treats discrete vessels, high pressure vessels and deep veins
Patented PowerFlex™ technology provides fast treatments and high efficacy; allows independent control of fluence, pulse duration and repetition rates to tailor your treatment parameters
Contact copper cooling provides the most efficient method of cooling for optimal skin protection and comfort
The “clearview” handpiece feature prevents vessel closure due to contact pressure
Easy on-the-fly spot size adjustment (3, 5, 7 mm) facilitates optimal selection for safety and results
Titan V HP (small areas) + Titan XL HP (large areas) Handpieces Features and SpecificationsTitan is the most researched and peer-reviewed infra-red solution for deep dermal heating of all skin.
Titan’s light source generates energy from 1100 to 1800 nm for safe and effective volumetric heating of the dermis
Titan candidates are often patients not yet ready for surgery
When combined with other non-ablative procedures that improve conditions such as dyschromia, Titan’s toning effect enhances overall results
Wavelength: 1100 – 1800 nm Infrared
Fluence / Energy: 5 to 65 J/cm2
Spot Size
Titan V – 10 mm x 15 mm
Titan XL – 10 mm x 30 mm
Tx Cycle: 4 to 10 Seconds
ProWave Hair Removal Handpiece Features and SpecificationsProWave has multiple wavelength technology switches modes from Alexandrite to Diode to near Nd:YAG for maximum results, safety and versatility—all in a single high speed device.
ProWave (770-1100 nm), combines unrivaled treatment speed with optimal results and safety. Maximum versatility is achieved multiple wavelength technology enabling treatment modes from Alexandrite to Diode to near Nd:YAG
Clinical studies showed > 80% hair reduction six months post three treatments
Wavelength: 770 – 1100 nm
Fluence: 5 to 35 J/cm2
Spot Size: 10 mm x 30 mm
Repetition Rate: 2 Hz
Cutera Xeo Laser System Specifications Cutera Xeo with Full Nd Yag and Low Pulses
Dimensions: 12″ W x 19″ D x 35″ H
System Cooling: Internal, self-contained
Electrical Info
115 V | 60 Hz | 20A
230 V | 60 Hz | 20A | 1 Phase
Weight: 135 lbs
Energist NeoGen PSR LaserNeoGen PSR SystemNeoGen nitrogen plasma technology delivers controlled heating to the skin architecture stimulating a significant physiological response, without creating an open wound. Unlike ablative technologies there is no epidermal vaporisation or charring caused at time of treatment.
Unique TechnologyNeoGen converts nitrogen gas into plasma energy, the fourth state of matter. The plasma emerges from the handpiece in controlled pulses and rapid heating of tissue occurs as it gives up its unique thermal energy to tissue.
No Open WoundsThe treated photodamaged layers undergo a controlled thermal modification, while remaining intact, creating a natural dressing to provide protection and speed healing. at high energies the epidermis sheds, but only after a new, healthier skin architecture is formed beneath.
Treats the Whole Skin ArchitectureTreating the entire skin structure ensures optimal results as the entire surface is regenerated with associated neocollagenesis and neoelastogenesis. No islands of untreated skin remain. Clinical studies show significant tightening – Mean 22% improvement in upper eyelid tightening (JOCD 7, 169-179, 2008).
Eyelids and Periorbital TreatmentEnergist NeoGen PSR is the ideal option for the treatment of the upper and lower eyelids, as well as the wider periorbital region. Other technologies cannot be used in this area or deliver inconsistent results.
Long Lasting ResultsClinical studies show neocollagenesis and reduction in elastosis continuing for more than one year post treatment.The Proven Power of Plasma for Skin Regeneration Energist NeoGen PSR Laser• Unique technology – controlled pulses of nitrogen plasma energy
• Treats the whole skin architecture – no islands of untreated skin remain
• Deep Tissue Remodelling – epidermis acts as natural dressing post treatment
• Versatile – high or low energy treatment choices to fit your patients’ needs and lifestyle
• Precise – treat eyelids effectively with significant results
• Long-lasting effects – intense fibroblast activity supports continued regeneration.
• Consistent – non-fractionated and non-chromophore dependence assures uniform energy absorption
• Proven Plasma Skin Regeneration is supported by numerous IRB-controlled studies
TechnologyPlasma skin regeneration was introduced with a level of scientific and clinical testing never before seen in the industry:
• 3+ years of pre-clinical and clinical testing
• 16 separate studies
• more than 450 clinical study treatments –No scarring or Hypopigmentation noted in studies
• one year clinical histology
This level of testing is very rare in the industryEnergist NeoGen PSR uses a highly energized gaseous state known as plasma to produce a unique thermal profile to penetrate the superficial and deeper levels of the dermis to replace damaged collagen and encourage new collagen growth for new skin. Plasma is produced inside the handpiece through the combination of inert nitrogen gas and ultra-high frequency RF.The Energist NeoGen PSR is emitted in millisecond pulses; the longer the pulse, the more energy is delivered. Nitrogen molecules impact the skin’s surface and immediately transfer energy upon contact. When the nitrogen plasma impacts the skin surface, energy is immediately transferred to the tissue. Oxygen is purged from the skin surface by the plasma, preventing carbonisation. The energy delivered to tissue ranges from 1 – 4 Joules and is user-adjustable. The repetition rate of the plasma pulses can also be controlled, and ranges from 1 – 2.5 Hertz.Specifications Energist NeoGen PSR
Power:
100 – 120 / 230 Vrms – 50/60 Hz – 650 Va
Energy Output:
Pulsed nitrogen plasma – 1-4 Joules.
Repetition Rate:
1.0 – 2.5Hz
Dimensions:
470 x 430 x 1060mm
Gas Requirement:
Medical Grade Nitrogen
System Weight:
18kg/40lb
Trolley Weight:
25kg/55lb (excludes gas tank)
Ambient Environment:
0 to 40 celsius
Relative Humidity:
30 to 75%
atmospheric pressure:
700 to 1600 hpa
CUTERA SECRET RF 2.0CUTERA SECRET RF 2.0 MICRONEEDLING RADIO is a fractional micro-needling system (fractional radiofrequency) that exceeds the capabilities and limitations of fractional laser significantly. It is a system for extensive skin structure improvement and treatment of hyperhidrosis (radio frequency thermotherapy RFTT), based on both monopolar and fractionated on, bipolar radio frequency. An exact adjustment of the depth of the microneedles and the cold passing the epidermis allow the energy output directly into the target layer.
The needle depth is 0.5 mm to 3.5 mm can be varied, thereby opening up a wide range of treatments. The adjustable intensity of the RF energy allows for the treatment of various areas of the body with different energy performance.The ability to work specifically in the deep dermis, without damaging the epidermis, is regulated in the RF Secret by the delay time of fractional radiofrequency. The needles are inserted at a rate of milliseconds equal to a stamping process in the skin and also withdrawn immediately. Only after the needles are penetrated into the desired skin layer, is carried out for a few milliseconds, a radio frequency pulse to set heat damage. While the penetration into the skin, the needles remain always cold. In order to achieve a deep and superficial effect, the needle depths can be varied individually in the respective treatment passes.Dermal Remodeling from the Inside Out
Demand for non-surgical aesthetic procedures with little to no downtime is on the rise. More than 70% of patients are bothered by signs of aging such as fine lines and wrinkles as well as skin texture and discoloration.1Secret RF is a novel fractional radio frequency (RF) micro-needling system for tissue coagulation and hemostasis designed to stimulate and remodel collagen and address the common signs of aging. It is ideally suited for use on patients who wish to revitalize and refresh the appearance of their skin on all skin types. By adjusting the micro-needles, Secret RF can deliver energy at various depths, so that treatments can be tailored to address each patients individual concerns such as fine lines, wrinkles, acne scars, photoaging and striae at the depth required.Secret RF System
Secret RFs unique technology and customized delivery of energy enables providers to tailor treatments for a variety of skin concerns on all skin types.Customized Dermal Remodeling
Secret RF induces dermal remodeling by applying precisely controlled RF energy directly into various depths of skin from 0.5-3.5 mm – with minimally invasive micro-needles to spare the epidermis and reduce patient downtime.
Skin Revitalization and Resurfacing
Secret RF is a radio frequency (RF) fractional microneedling system that helps you deliver tailored energy to improve fine lines, wrinkles, and scars from the inside out.
Secret RF in action
Applications include fine lines and wrinkles, photoaging, scarring, acne scars, striaeSecret RF technology
Handpieces
Two sizes of treatment tips – 25 and 64 pin – give you customizable options for treating the face and body with precision and efficiency.
Power:20 W ± 20%
RF frequency:2 Mh ± 20%
Intensity:0 ~ 100 Level (10 levels)
Repeat:0.2 / 0.5 / 1/2 sec / individually.
Needle Size:0.3 mm
Info about needles:25 electric needles (5 x 5, 7.8 mm x 7.8 mm / height: 1.95 mm (standard) and 16 electric needles (4 x 4, 7.8 mm x 7.8 mm / height 2.6 mm (optional)
Treatment range:1 x 1cm
Adjustable Depth:0.5 ~5 mm (0.1 steps)
Treatment duration:50 ms ~ 950 ms
Electrical power:100 ~ 240 VAC, 50/60 Hz, 220 VAMonopolar RF
Power:520 W ± 20%
RF frequency:2 Mh ± 20%
RF electrode:monopolar
Repeat:CW
RF electrode size:15APPLICATIONSFacialsNon-surgical facelift
Skin tightening
Pore reduction
Wrinkle reduction
Skin Rejuvenation (illumination)
Acne scars
Body treatmentsScar
Keratosis pilaris (Keratosis pilaris)
Stretch marks
Reviews
There are no reviews yet.