PERKASA MEDICAL

Free shipping worldwide. Orders over $200
Availability: In Stock

Lumenis Pollogen Legend Pro 2020

$7,500.00

Thanks to the unique technologies behind Legend Pro, patients experience minimal pain and downtime during and after treatment, without the need of numbing cream before the treatment. The desired results are promptly visible. Indications include: skin resurfacing and treatment of mild to moderate wrinkles and rhytids.

Other people want this. 15 people have this in their carts right now.

Description

Lumenis Pollogen Legend Pro 2020

Activating the body’s natural healing processes by applying RF-assisted ultra-thin electrodes to thermally ablate the epidermis, creating micro channels to induce controlled micro wounds, thus encouraging the generation of new and healthy skin.

TriFractional

Applying contact RF and pin point ablation with controlled volumetric heating to achieve skin resurfacing and regeneration via wound healing process, resulting in skin texture improvement and refinement.

M² unique synergized treatment combines the macro volumetric heating of tissue with TriPollar RF and the precise micro heating of focal points with VoluDerm RF assisted ultra-thin electrodes. Treatments with M² reaches multiple layers of the skin introducing a wide range of solutions for skin resurfacing and inducing regeneration as well as wrinkle reduction.

Thanks to the unique technologies behind , patients experience minimal pain and downtime during and after treatment, without the need of numbing cream before the treatment. The desired results are promptly visible. Indications include: skin resurfacing and treatment of mild to moderate wrinkles and rhytids.

IS AN ADVANCED MEDICAL AESTHETIC PLATFORM INCORPORATING THE LEADING INDUSTRY TECHNOLOGIES – HYBRID ENERGY TECHNOLOGY, TRILIPO USING NON-INVASIVE TRIPOLLAR RF ENERGY, AND DYNAMIC MUSCLE ACTIVATION. THE COMBINATION OF THESE TECHNOLOGIES PROVIDES EFFECTIVE DERMAL VOLUMIZING, SKIN TIGHTENING, AND BODY SCULPTING.

Lumenis Pollogen Legend Pro Laser device is effective and fast with minimal discomfort. It is suitable for all skin types and ethnicities and carried out in a simple ‘walk-in walk-out’ treatment with minimal downtime.

-Visible results after the 1st treatment

-Long-term measurable results

-Minimal discomfort, minimal downtime

-Easy to use with a fast learning curve

Lumenis Pollogen Legend Pro Laser system intended for dermatological procedures requiring ablation and resurfacing of the skin when using VoluDerm  Energy (Applicator VO). It is also intended for use in dermatologic and general surgical procedures for the non-invasive treatment of mild to moderate facial wrinkles and rhytides when using TriPollar RF Energy (Applicators 1-3)

Specification : Lumenis Pollogen Legend Pro 2020

Input Voltage:100-2400 Volt,50-60Hz, max 2.2A
Mode of Operation:VoluDerm, TriFractional, Tripollar
Maximum Output Power RF:50 Watts @ 200 Ohm
Maximum Output Voltage:100 Plus or Minus 10 Vrms
Output Frequency RF:1Mhz
Output Power Control RF:Pulse Width Modulation (PWM)
Weight: 66 Kgs
Dimensions:L1.5 x W1.5 x H3.6 Inch
Environmental Conditions for Operation
Temperature:15 Degrees Celsius to +30 Degrees Celsius (59-86 Degrees Farrenheit)
Relative Humidity:Up to 80%; Non- Condensing
Atmospheric Pressure: 70-106 kPa
Maximum Altitude:2000 Meters
Environmental Conditions for Transportation & Storage
Temperature:-20 Degrees Celsius to + 55 Degrees Celsius (-4-131 Degrees Farrenheit)
Relative Humidity:80%; Non-Condensing
Atmospheric Pressure:50-106 kPa
Maximum Altitude:2000 Meters

Reviews

There are no reviews yet.

Be the first to review “Lumenis Pollogen Legend Pro 2020”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsLumenis Pollogen Legend Pro 2020 removeELLMAN PELLEVE S5 REDUCTION SYSTEM FOR SALE removeLutronic Clarity II For Sale removeACTIVE OPTICAL EXTRA 818 IPL HAIR REMOVAL MACHINE remove2017 Lumenis M22 IPL with ResurFX For Sale removeEMVERA CLARO2 CO2 LASER FOR SALE remove
NameLumenis Pollogen Legend Pro 2020 removeELLMAN PELLEVE S5 REDUCTION SYSTEM FOR SALE removeLutronic Clarity II For Sale removeACTIVE OPTICAL EXTRA 818 IPL HAIR REMOVAL MACHINE remove2017 Lumenis M22 IPL with ResurFX For Sale removeEMVERA CLARO2 CO2 LASER FOR SALE remove
Image
SKU
Rating
Price $7,500.00 $8,500.00 $19,500.00 $5,250.00 $23,000.00 $8,500.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

DescriptionThanks to the unique technologies behind Legend Pro, patients experience minimal pain and downtime during and after treatment, without the need of numbing cream before the treatment. The desired results are promptly visible. Indications include: skin resurfacing and treatment of mild to moderate wrinkles and rhytids.Includes: Various Handpieces 1x 3 Button Fingerswitch Handpiece 1 Forcep 1 Infared Thermometer 1 Footswitch 1 Professional Cart 1 Suction Filter 1 Operator Manual Brochures

Advanced ergonomic handpiece with multi-spot, quick-zoom cartridges, and large touch screen GUI.

Includes: Footswitch Operators Manual AntiFreeze Coolant Patient & Operator Eyewear

2017 Lumenis M22 with ResurFX & IPL in Like-New Condition; Manufactured 10/22/2017; Based Unit Serial Number 11860, IPL Handpiece Serial Number: 4751; Nd Yag Serial Number: Perfect Cosmetic and Operating Condition, Single Owner; Handpieces Included & Total Pulse Counts: IPL Handpiece Total Pulse Count = 908; ResurFX Handpiece Pulse Count = 16 Pulses; Includes Expert Filters: 515nm, 560nm, 590nm, 615nm, 640nm, 695nm, and 755nm; Also Includes: Footswitch, Interlock, Operator Manual.Includes: 1 Fractional Scanner Handpiece for Ablative Skin Resurfacing 1 Incisional Handpiece with up to or less than .2mm Spot Size Handpiece Case Distance Gauges Footswitch Patient Eyewear Operator Eyewear Operator Manual Warning Sign
Content

Lumenis Pollogen Legend Pro 2020

Activating the body’s natural healing processes by applying RF-assisted ultra-thin electrodes to thermally ablate the epidermis, creating micro channels to induce controlled micro wounds, thus encouraging the generation of new and healthy skin.TriFractionalApplying contact RF and pin point ablation with controlled volumetric heating to achieve skin resurfacing and regeneration via wound healing process, resulting in skin texture improvement and refinement.M² unique synergized treatment combines the macro volumetric heating of tissue with TriPollar RF and the precise micro heating of focal points with VoluDerm RF assisted ultra-thin electrodes. Treatments with M² reaches multiple layers of the skin introducing a wide range of solutions for skin resurfacing and inducing regeneration as well as wrinkle reduction.Thanks to the unique technologies behind , patients experience minimal pain and downtime during and after treatment, without the need of numbing cream before the treatment. The desired results are promptly visible. Indications include: skin resurfacing and treatment of mild to moderate wrinkles and rhytids.IS AN ADVANCED MEDICAL AESTHETIC PLATFORM INCORPORATING THE LEADING INDUSTRY TECHNOLOGIES – HYBRID ENERGY TECHNOLOGY, TRILIPO USING NON-INVASIVE TRIPOLLAR RF ENERGY, AND DYNAMIC MUSCLE ACTIVATION. THE COMBINATION OF THESE TECHNOLOGIES PROVIDES EFFECTIVE DERMAL VOLUMIZING, SKIN TIGHTENING, AND BODY SCULPTING.Lumenis Pollogen Legend Pro Laser device is effective and fast with minimal discomfort. It is suitable for all skin types and ethnicities and carried out in a simple ‘walk-in walk-out’ treatment with minimal downtime.-Visible results after the 1st treatment-Long-term measurable results-Minimal discomfort, minimal downtime-Easy to use with a fast learning curveLumenis Pollogen Legend Pro Laser system intended for dermatological procedures requiring ablation and resurfacing of the skin when using VoluDerm  Energy (Applicator VO). It is also intended for use in dermatologic and general surgical procedures for the non-invasive treatment of mild to moderate facial wrinkles and rhytides when using TriPollar RF Energy (Applicators 1-3)Specification : Lumenis Pollogen Legend Pro 2020Input Voltage:100-2400 Volt,50-60Hz, max 2.2A Mode of Operation:VoluDerm, TriFractional, Tripollar Maximum Output Power RF:50 Watts @ 200 Ohm Maximum Output Voltage:100 Plus or Minus 10 Vrms Output Frequency RF:1Mhz Output Power Control RF:Pulse Width Modulation (PWM) Weight: 66 Kgs Dimensions:L1.5 x W1.5 x H3.6 Inch Environmental Conditions for Operation Temperature:15 Degrees Celsius to +30 Degrees Celsius (59-86 Degrees Farrenheit) Relative Humidity:Up to 80%; Non- Condensing Atmospheric Pressure: 70-106 kPa Maximum Altitude:2000 Meters Environmental Conditions for Transportation & Storage Temperature:-20 Degrees Celsius to + 55 Degrees Celsius (-4-131 Degrees Farrenheit) Relative Humidity:80%; Non-Condensing Atmospheric Pressure:50-106 kPa Maximum Altitude:2000 Meters

ELLMAN PELLEVE S5 REDUCTION SYSTEM

The Pelleve S5 System is a new generator based on the proven Surgitron technology. In addition to powering the Pelleve handpieces, it provides maximum control in precision cutting with minimal thermal damage to surrounding tissues, plus more versatility than other energy-based technologies, including:Wrinkle reduction treatment with the new GlideSafe(TM) handpieces Hundreds of surgical electrodes and accessories for most specialties Portable and light weight – ideal for office and clinic environmentsWxHxD: 9.5 x 7.1 x 16.5 Weight: 26 lbs. Ambeint Temperature: +10 degrees C – +40 degrees C Relative Humidity: 30% – 75% Normal Line Voltage: 100V, 120V / 220V, 240V – + 10% Line Frequency: 60Hz./50Hz. Input current at max output power: 3.4A/1.5A Pelleve Wrinkle Reduction System Ellagance Through Science Pelleve S5 SystemPelleve precisely delivers energy to the dermal tissue using advanced radiofrequency technology to induce collagen contraction without damaging the epidermis. The result is skin tightening and contouring with a noticeable improvement in skin quality and texture.Pelleve’s unique radiofrequency technology emits energy in the form of electromagnetic waves, which create a heated treatment zone. Increased resistance causes heat buildup at the subdermal junction. Heat induces collagen denaturation and collagen contraction. Protein stimulation causes new collagen formation and production in the dermis which also results in epidermal tightening. Existing bands of collagen tighten in subcutaneous fat, creating a superficial tightening of the epidermis.Unparalleled Safety ELLMAN PELLEVE S5 REDUCTION SYSTEM The Pelleve System delivers continuous radiofrequency energy which enables the clinician to choose how much energy to deliver and in what areas. By using a combination of the different sizes of Pelleve handpieces that are available each patient’s specific areas of concern can be addressed, resulting in patients receiving just the right amount of energy. The new GlideSafe handpieces feature an innovative sensor designed to stop energy flow when the device senses loss of contact with skin, further enhancing the safety.Non invasive, non ablative office treatment Patients today are seeking affordable, non invasive alternatives to ablative and surgical procedures. The Pelleve System fills that void.Minimal side effects A Pelleve treatment is virtually pain free and no anesthetic is used for the treatment. The patient may experience some transient erythema or edema, which is typically gone in a few hours.PelleFirm is a non-invasive cellulite treatment that uses radiofrequency energy and massage to deeply heat tissues and temporarily reduce the appearance of cellulite.ELLMAN PELLEVE S5 (TM) HandpiecesPelleve GlideSafe handpieces feature an innovative sensor designed to stop energy flow when the device senses loss of contact with skin – resulting in a more comfortable treatment for the patient. The GlideSafe Handpieces are available in 4 sizes – 7.5 mm, 10 mm, 15 mm, 20 mm – to allow the physician clinician to customize to the individual patient. The compact ergonomic design enables practitioners to comfortably maneuver around the contours of the face, including areas that are difficult to access such as the periorbital region. Each handpiece delivers multiple hours of treatment (activation) time so doctors have the option of customizing each patient’s treatment by using different size handpieces for different areas of the face. This advanced feature allows users to treat multiple patients and perform many procedures using the same charged handpiece.Surgical Versatility An innovative multi-modality system, the Pelleve Wrinkle Reduction System offers physicians unmatched versatility in a compact design. Beyond skin tightening, the ELLMAN PELLEVE S5 platform facilitates scores of procedures with the availability of hundreds of monopolar and bipolar electrodes.Skin tightening plus surgical procedures You can use the Pelleve system to deliver aesthetic treatments plus surgical treatments with the S5 platformAdds value to your practice An ideal procedure to delegate to physician extenders and bundle with other servicesPractice profitability Low operating costs yield enhanced profitability relative to treatment feeWide range of surgical electrodesFor use with the Pelleve Generator and all other Ellman generators are hundreds of standard and specialty surgical electrodes facilitate procedures ranging from minimally invasive treatments through full surgical procedures. Unlike conventional ESU generators, the Ellman generators are high-frequency radiofrequency devices that enable precise cutting and control with minimal thermal damage. Minimizing tissue damage improves aesthetic outcomes and reduces recovery time. 

Lutronic Clarity II

Lutronic’s Clarity II is a high-powered, dual-wavelength platform that effectively delivers a wider range of parameters to help safely and efficiently treat the broadest indications with ease. The innovative design includes: a single fiber for all spot sizes(2-25mm), intuitive interface, and no need for calibration after any parameter change. Clarity II can save time and help facilitate faster, more effective treatments. Higher power 755/1064nm platform for effective treatments up to 45%* faster. Brilliantly removes hair, pigment, and vascular lesions in all skin types. IntelliTrak technology and Temperature Sensing enable increased provider confidence and treatment efficacy.Clarity II Key Feature 1. Powerful and faster Provide up to 25mm spot size at a useable >2 Hz High power performance Up to 45% faster 2. Intelligent and convenientIntelliTraking system to prevent skip area and consistent treatment Real time skin temperature monitoring system 3. Designed for versatilityIntelligent memory function to keep track of past treatment history in detail Zoom cartridge system for treatment areaLutronic Clarity IIHow It Works The CLARITY II Laser System contains two separate laser resonators, Alexandrite and an Nd:YAG, which generate pulse laser energy at the nominal wavelength of 755nm and 1064nm respectively. The output of each laser generator and the 515nm aiming beam are optically combined on the laser rail so that their beam paths are identical as they exit the laser system. This allows the use of a single delivery system for either the 755nm or 1064nm wavelength.Clarity II with IntelliTrak technologyHigher-powered 755/1064nm platform laser Up to 2X faster Laser Hair Removal Txs* Exclusive shorter pulsewidths available including 1ms setting for finer facial hairs Breakthrough intelligent capabilities IntelliTrak technology for faster more consistent Tx coverage Temperature Sensing for real-time skin temp feedback during Tx Auto-calibration in seconds saves time and improves productivity Advanced, easy-to-use platform Single fiber for all 2-24mm spot cartridges Numerous skin rejuvenation capabilities including vascular, pigment, and toning Txs *At settings of: 755nm, 5ms, 12J/cm2: Clarity II at 22mm, 3Hz, IntelliTrak at 18% overlap vs. older system at 18mm, 2Hz, and est. ~18% manual overlap. Geometric treatment coverage speed is 11.4cm/second with Clarity II vs. 5.1cm/second with older system. 
ACTIVE OPTICAL EXTRA 818 IPL HAIR REMOVAL MACHINEIncludes: Footswitch Operators Manual AntiFreeze Coolant Patient & Operator EyewearHandpieces:Hair Removal Handpiece and Facial Handpiece Chilled Tip:Up to 4c Pulse Interval:0.5~2 Seconds Output Power:11-31 joule/cm2, upto 4,000W Cooling System:Revolutionary dual cooling Control:Intuitive touch screen control Lamp’s Life Span:250,000 Flashes (Universal), 200,000 Flashes (Facial) Treatment Area:7.5 cm2 (15*50mm) Universal, 4.5 cm2 (15*30mm) Facial Wavelength:420-1100 nm Weight:42Kg (including Stand, if device is not a table top) Dimensions:44cm x 45cm x 100cm Extra-818 Skin Rejuvenation Pigmentation Treatment Acne Treatment Hair Removal Vascular (Facial) TreatmentThe combination of tested treatment protocols with high end engineering makes the Extra – 818 the perfect device for leading clinics.Revolutionary Cooling System The Extra – 818 has a dual cooling system, controlled and monitored in order to ensure long lifetime to the lamp and a comfortable treatment to the patient.Competitive cooling systems “freeze” the skin so that during the treatment the skin temperature will rise to a bearable level. However, this “freezing” temperature might limit the results because the follicles will not reach the coagulation temperature. To ensure optimal results Active installed a special Processor that prevents overcooling the skin and maintains a uniform low temperature of the “glass” throughout the treatment. This revolutionary system enables the Extra – 818 to provide best results with optimal patient comfort.Research Program ACTIVE OPTICAL EXTRA 818 IPL HAIR REMOVAL MACHINE For clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31Jcm2 with high intensity of 4,000W.The Active Optical Extra 818 IPL Hair Removal and Skin Rejuvenation is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features: * Contemporary touch screen control * Built-in Patch Test procedure for examining the optimal energy level * A stunning number of 450,000 flashes in both lamps.The Extra – 818, based on Active’s GEM-PL technology, sets sets a specific Pulse Pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings. 

2017 Lumenis M22 IPL with ResurFX

Manufacturer Notes
M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal.Available Treatments with M22:– Acne Scar Treatment – Hair Removal – Non-Ablative Skin Resurfacing – Photorejuvenation – Pigmentation Treatment – Scar Revision – Vascular / Leg Vein Treatment – Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge.Universal IPL Optimal Pulse Technology (OPT) Single handpiece with changeable filters and lightguides For IPL skin treatments using photorejuvenationResurFX The only True fractional non-ablative, with CoolScan scanner No disposables For skin resurfacingMulti-Spot Nd:YAG The only one with Multiple Sequential Pulsing (MSP) 2 sized lightguides, changeable in seconds For treatment of leg veins and vascular lesionsQ-Switched Nd:YAG Homogenous beam profile for enhanced treatment safety and efficacy For skin toning*, dark tattoos removal, and combination treatments *Skin toning by treatment of pigmented lesions

2017 Lumenis M22 IPL with ResurFX and Q-Switched Nd:YAG

A modular multi-application system for hair removal and various skin conditions

Details:

  • M22 Serial Number: 21171

  • M22 Date of Manufacture: 2017-07-17

  • Total IPL Pulses: 19,186

  • Total ResurFX Pulses: 10,772

  • Q-Switched Nd:YAG Pulses: 385,505

Includes:

  • IPL Handpiece

  • Complete Standard IPL filters: 515, 560, 590, 615, 640, 695, 755nm, and Calibration

  • Specialty IPL Filters: Acne and Vascular

  • IPL Light Guides: (1)35 x 15 mm2; (1)15 x 8 mm2, (1) 6mm- round

  • ResurFX Handpiece with SapphireCool Tip

  • Q-Switched Nd:YAG Handpiece

  • Foot Switch

  • Power Cord

  • 30 Days Parts and Labor Warranty

System specifications Dimensions:[without ResurFX] 44 x 50.5 x 47 cm (17 x 20 x 18.5 inches) Dimensions:[with ResurFX] 44 x 50.5 x 61.5 cm (17 X 20 X 24 inches) Weight:[without ResurFX] 40 kg / 88 lbs Weight:[with ResurFX] 55 kg / 121 lbs Electrical requirements:100  240 VAC ±10%, 15A max., 50/60 Hz, single phase, dedicated line
M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal.Available Treatments with M22:– Acne Scar Treatment – Hair Removal – Non-Ablative Skin Resurfacing – Photorejuvenation – Pigmentation Treatment – Scar Revision – Vascular / Leg Vein Treatment – Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge.Universal IPL Optimal Pulse Technology (OPT) Single handpiece with changeable filters and lightguides For IPL skin treatments using photorejuvenationResurFX The only True fractional non-ablative, with CoolScan scanner No disposables For skin resurfacingMulti-Spot Nd:YAG The only one with Multiple Sequential Pulsing (MSP) 2 sized lightguides, changeable in seconds For treatment of leg veins and vascular lesions

EMVERA CLARO2 CO2 LASER

Claro2 Medical Laser System The Claro2 laser technology offers the most innovative approach to laser treatments today. It provides an acceptable and comfortable procedure under little or no anesthesia with minimum pain from evaporation of the skin layers, resulting in minimal social or work downtime. The laser delivers a series of microscopic, closely-spaced laser spots to the skin while simultaneously preserving the normal, healthy skin. The undamaged skin becomes a reservoir of tissue for fast heating and regeneration of the treated area by producing and providing new dermal collagen and eliminating epidermal pigmentation and irregularities to the skin tone. The Claro2 laser system is specially designed to improve skin texture and tone, and fight wrinkles, scars and pigmentations. Since the treatment procedures are customized to patients’ skin, operators are able to adjust laser settings to tailor treatments and achieve superior results.Claro2 Laser Features Provide: • Unparalleled char-free ablation, vaporization, excision, or incision of soft tissues • Reduced thermal damage to surrounding tissues • Rapid healing and minimal downtime • Stimulation of deeper collagen with high pulse energy • Large TFT LCD touch screen provides easy operation with the latest high speed microprocessor technology • Adjustable scanning patterns and sizes • Adjustable intensity of pilot beam • Adjustable pulse duration • Last treatment setting memorization • Automatic alarm system for operation and errors • No consumable costsIncludes: 1 Fractional Scanner Handpiece for Ablative Skin Resurfacing 1 Incisional Handpiece with up to or less than .2mm Spot Size Handpiece Case Distance Gauges Footswitch Patient Eyewear Operator Eyewear Operator Manual Warning SignLaser Type:Sealed of Co2 Laser Wavelength:10.6 um Mode Structure:TEM00 Max Power:0-30W (adjustable) Spot Size:Equal to or less than .2mm Aiming Beam:630nm Red Laser (Adjustable Brightness) Delivery System:Articulated Arm Operation Modes:Continuous Wave, Single Pulse, Repetition Pulse, Super Pulse, Scanner Pulse Width:Single Pulse (0.01-1s); Repetition Pulse (0.001-1s); Scanner (0.0001-0.01s) Scan Size: Adjustable Scan Pattern:Oval, Triangle, Rectangle, Line Scan Array Density:Adjustable Cooling System:Self-Contained, Closed Cycle Power Supply:100-120V AC, 50/60Hz or 200-240V AC, 50/60Hz Environment Temperature:10-40 Degrees Celsius Relative Humidity:Below 80% Dimensions:561mm x 500mm x 1443mm Weight:42kgApplications Include:EMVERA CLARO2 CO2 LASERDermatology, Plastic Surgery and General Surgery procedures including but not limited to: • Laser skin resurfacing • Treatment of furrows and wrinkles • Removal of skin tags, actinic keratosis, acne scars, keloids, tattoos, telangiectasia, squamous and basel cell carcinoma, warts and uneven pigmentation • Treatment of cysts, abscesses, hemorrhoids and other soft tissue applications • Blepharoplasty • Site preparation for hair transplantsOtorhinolaryngology (ENT) procedures including but not limited to: • Treatment of leukoplakia of larynx, nasal obstruction, rhinophyma, verrucrea vulgares, choanal atresia, rhinophyma, LAUP and papillomatosis polypsGynecology: • Treatment of condyloma acuminate, cervical intraepithelial neoplasia, leukoplakia and vulvar/ vaginal intraepithelial neoplasia, cervical dysplasia Podiatry procedures including but not limited to: • Ablation, vaporization and excision of soft tissue lesions such as ingrown nail, fungal nail, porokcratoma, matrixectomy and verrucae vulgares 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: Lumenis Pollogen Legend Pro 2020 $7,500.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Shopping cart close