| Description | Thanks to the unique technologies behind Legend Pro, patients experience minimal pain and downtime during and after treatment, without the need of numbing cream before the treatment. The desired results are promptly visible. Indications include: skin resurfacing and treatment of mild to moderate wrinkles and rhytids. | Includes:
1 Fractional Scanner Handpiece for Ablative Skin Resurfacing
1 Incisional Handpiece with up to or less than .2mm Spot Size
Handpiece Case
Distance Gauges
Footswitch
Patient Eyewear
Operator Eyewear
Operator Manual
Warning Sign | Advanced ergonomic handpiece with multi-spot, quick-zoom cartridges, and large touch screen GUI. | Laser Hair Removal
Details:- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| Highest available power allows for fast treatments, customizable for multiple areas
Gentle, effective global improvement for all skin types, all year-round
Comfortable treatments with very little downtime
Minimal cost of ownership, easy to delegate and no shot limit per procedure | Includes:
Articulated Arm
2 Acuscan 120 Handpieces
125mm Incisional Handpiece
F-125 Attachments
Key |
| Content | Lumenis Pollogen Legend Pro 2020
Activating the body’s natural healing processes by applying RF-assisted ultra-thin electrodes to thermally ablate the epidermis, creating micro channels to induce controlled micro wounds, thus encouraging the generation of new and healthy skin.TriFractionalApplying contact RF and pin point ablation with controlled volumetric heating to achieve skin resurfacing and regeneration via wound healing process, resulting in skin texture improvement and refinement.M² unique synergized treatment combines the macro volumetric heating of tissue with TriPollar RF and the precise micro heating of focal points with VoluDerm RF assisted ultra-thin electrodes. Treatments with M² reaches multiple layers of the skin introducing a wide range of solutions for skin resurfacing and inducing regeneration as well as wrinkle reduction.Thanks to the unique technologies behind , patients experience minimal pain and downtime during and after treatment, without the need of numbing cream before the treatment. The desired results are promptly visible. Indications include: skin resurfacing and treatment of mild to moderate wrinkles and rhytids.IS AN ADVANCED MEDICAL AESTHETIC PLATFORM INCORPORATING THE LEADING INDUSTRY TECHNOLOGIES – HYBRID ENERGY TECHNOLOGY, TRILIPO USING NON-INVASIVE TRIPOLLAR RF ENERGY, AND DYNAMIC MUSCLE ACTIVATION. THE COMBINATION OF THESE TECHNOLOGIES PROVIDES EFFECTIVE DERMAL VOLUMIZING, SKIN TIGHTENING, AND BODY SCULPTING.Lumenis Pollogen Legend Pro Laser device is effective and fast with minimal discomfort. It is suitable for all skin types and ethnicities and carried out in a simple ‘walk-in walk-out’ treatment with minimal downtime.-Visible results after the 1st treatment-Long-term measurable results-Minimal discomfort, minimal downtime-Easy to use with a fast learning curveLumenis Pollogen Legend Pro Laser system intended for dermatological procedures requiring ablation and resurfacing of the skin when using VoluDerm Energy (Applicator VO). It is also intended for use in dermatologic and general surgical procedures for the non-invasive treatment of mild to moderate facial wrinkles and rhytides when using TriPollar RF Energy (Applicators 1-3)Specification : Lumenis Pollogen Legend Pro 2020Input Voltage:100-2400 Volt,50-60Hz, max 2.2A
Mode of Operation:VoluDerm, TriFractional, Tripollar
Maximum Output Power RF:50 Watts @ 200 Ohm
Maximum Output Voltage:100 Plus or Minus 10 Vrms
Output Frequency RF:1Mhz
Output Power Control RF:Pulse Width Modulation (PWM)
Weight: 66 Kgs
Dimensions:L1.5 x W1.5 x H3.6 Inch
Environmental Conditions for Operation
Temperature:15 Degrees Celsius to +30 Degrees Celsius (59-86 Degrees Farrenheit)
Relative Humidity:Up to 80%; Non- Condensing
Atmospheric Pressure: 70-106 kPa
Maximum Altitude:2000 Meters
Environmental Conditions for Transportation & Storage
Temperature:-20 Degrees Celsius to + 55 Degrees Celsius (-4-131 Degrees Farrenheit)
Relative Humidity:80%; Non-Condensing
Atmospheric Pressure:50-106 kPa
Maximum Altitude:2000 Meters | EMVERA CLARO2 CO2 LASER
Claro2 Medical Laser System
The Claro2 laser technology offers the most innovative approach to laser treatments today. It provides an acceptable and comfortable procedure under little or no anesthesia with minimum pain from evaporation of the skin layers, resulting in minimal social or work downtime. The laser delivers a series of microscopic, closely-spaced laser spots to the skin while simultaneously preserving the normal, healthy skin. The undamaged skin becomes a reservoir of tissue for fast heating and regeneration of the treated area by producing and providing new dermal collagen and eliminating epidermal pigmentation and irregularities to the skin tone. The Claro2 laser system is specially designed to improve skin texture and tone, and fight wrinkles, scars and pigmentations. Since the treatment procedures are customized to patients skin, operators are able to adjust laser settings to tailor treatments and achieve superior results.Claro2 Laser Features Provide:
Unparalleled char-free ablation, vaporization, excision, or incision of soft tissues
Reduced thermal damage to surrounding tissues
Rapid healing and minimal downtime
Stimulation of deeper collagen with high pulse energy
Large TFT LCD touch screen provides easy operation with the latest high speed microprocessor technology
Adjustable scanning patterns and sizes
Adjustable intensity of pilot beam
Adjustable pulse duration
Last treatment setting memorization
Automatic alarm system for operation and errors
No consumable costsIncludes:
1 Fractional Scanner Handpiece for Ablative Skin Resurfacing
1 Incisional Handpiece with up to or less than .2mm Spot Size
Handpiece Case
Distance Gauges
Footswitch
Patient Eyewear
Operator Eyewear
Operator Manual
Warning SignLaser Type:Sealed of Co2 Laser
Wavelength:10.6 um
Mode Structure:TEM00
Max Power:0-30W (adjustable)
Spot Size:Equal to or less than .2mm
Aiming Beam:630nm Red Laser (Adjustable Brightness)
Delivery System:Articulated Arm
Operation Modes:Continuous Wave, Single Pulse, Repetition Pulse, Super Pulse, Scanner
Pulse Width:Single Pulse (0.01-1s); Repetition Pulse (0.001-1s); Scanner (0.0001-0.01s)
Scan Size: Adjustable
Scan Pattern:Oval, Triangle, Rectangle, Line
Scan Array Density:Adjustable
Cooling System:Self-Contained, Closed Cycle
Power Supply:100-120V AC, 50/60Hz or 200-240V AC, 50/60Hz
Environment Temperature:10-40 Degrees Celsius
Relative Humidity:Below 80%
Dimensions:561mm x 500mm x 1443mm
Weight:42kgApplications Include:EMVERA CLARO2 CO2 LASERDermatology, Plastic Surgery and General Surgery procedures including but not limited to:
Laser skin resurfacing
Treatment of furrows and wrinkles
Removal of skin tags, actinic keratosis, acne scars, keloids, tattoos, telangiectasia, squamous and basel cell carcinoma, warts and uneven pigmentation
Treatment of cysts, abscesses, hemorrhoids and other soft tissue applications
Blepharoplasty
Site preparation for hair transplantsOtorhinolaryngology (ENT) procedures including but not limited to:
Treatment of leukoplakia of larynx, nasal obstruction, rhinophyma, verrucrea vulgares, choanal atresia, rhinophyma, LAUP and papillomatosis polypsGynecology:
Treatment of condyloma acuminate, cervical
intraepithelial neoplasia, leukoplakia and vulvar/
vaginal intraepithelial neoplasia, cervical dysplasia
Podiatry procedures including but not limited to:
Ablation, vaporization and excision of soft
tissue lesions such as ingrown nail, fungal nail,
porokcratoma, matrixectomy and verrucae vulgares | Lutronic Clarity II
Lutronic’s Clarity II is a high-powered, dual-wavelength platform that effectively delivers a wider range of parameters to help safely and efficiently treat the broadest indications with ease. The innovative design includes: a single fiber for all spot sizes(2-25mm), intuitive interface, and no need for calibration after any parameter change. Clarity II can save time and help facilitate faster, more effective treatments.
Higher power 755/1064nm platform for effective treatments up to 45%* faster.
Brilliantly removes hair, pigment, and vascular lesions in all skin types.
IntelliTrak technology and Temperature Sensing enable increased provider confidence and treatment efficacy.Clarity II
Key Feature
1. Powerful and faster
Provide up to 25mm spot size at a useable >2 Hz
High power performance
Up to 45% faster
2. Intelligent and convenientIntelliTraking system to prevent skip area and consistent treatment
Real time skin temperature monitoring system
3. Designed for versatilityIntelligent memory function to keep track of past treatment history in detail
Zoom cartridge system for treatment areaLutronic Clarity IIHow It Works
The CLARITY II Laser System contains two separate laser resonators, Alexandrite and an Nd:YAG, which generate pulse laser energy at the nominal wavelength of 755nm and 1064nm respectively. The output of each laser generator and the 515nm aiming beam are optically combined on the laser rail so that their beam paths are identical as they exit the laser system. This allows the use of a single delivery system for either the 755nm or 1064nm wavelength.Clarity II
with IntelliTrak technologyHigher-powered 755/1064nm platform laser
Up to 2X faster Laser Hair Removal Txs*
Exclusive shorter pulsewidths available including 1ms setting
for finer facial hairs
Breakthrough intelligent capabilities
IntelliTrak technology for faster more consistent Tx coverage
Temperature Sensing for real-time skin temp feedback
during Tx
Auto-calibration in seconds saves time and
improves productivity
Advanced, easy-to-use platform
Single fiber for all 2-24mm spot cartridges
Numerous skin rejuvenation capabilities including vascular,
pigment, and toning Txs
*At settings of: 755nm, 5ms, 12J/cm2: Clarity II at 22mm, 3Hz, IntelliTrak at 18% overlap vs.
older system at 18mm, 2Hz, and est. ~18% manual overlap. Geometric treatment coverage speed is
11.4cm/second with Clarity II vs. 5.1cm/second with older system. | 2019 Lumenis Splendor X- Laser Hair Removal
Lumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthThe Lumenis Splendor X has been introduced to be a player in the solid state Nd:YAG and Alexandrite laser hair removal market. The gold standard for hair removal has always been considered Alexandrite 755nm for light skins and Nd:YAG 1064nm for dark skins.The Lumenis Splendor X combines both in a unique way with blended emission.Instead of firing a single wavelength at a time the Splendor X allows you to fire both wavelengths simultaneous in adjustable amounts to suit the skin type and hair types. This means you are target multiple chromophores at any given time given enhanced results across the board.The Lumenis Splendor X also allows the user to choose between square and round spot sizes with large spot sizesLumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthLaser Hair Removal
Details:2019 Lumenis Splendor X- Laser Hair Removal- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| 2015 Lutronic LaseMD Pro Fractional Skin Wrinkles
Lutronic LaseMD Ultra Laser is an impressive upgrade to their already successful LaseMD,” shared Steven Weiner, MD, from Lutronic.“Not only is it more powerful (20 watts vs 12 watts) but it also has a significantly lower consumable cost than competitive systems. The LaseMD ULTRA offers a new larger spot size and incorporates improved ‘top hat’ beam profile. The system also offers an incredibly advanced graphical user interface.“The integration of all the new features with real-time information helps reduce treatment time and achieve satisfying patient results in fewer treatments. Since no anesthesia is required, I can treat a full face in about 6-8 minutes or treat the face, neck and chest in 20 minutes.”Lutronic LaseMD Ultra Laser is yet another example of Lutronic’s commitment to Intelligent Design for Intelligent Care, according to the company in a media release. Features include:Highest available power allows for fast treatments, customizable for multiple areas
Gentle, effective global improvement for all skin types, all year-round
Comfortable treatments with very little downtime
Minimal cost of ownership, easy to delegate and no shot limit per procedure“LaseMD ULTRA is my favorite new addition to my practice. It allows me to treat multiple areas quickly, effectively and for very low cost,” adds Joel Cohen, MD, in the release. “My patients love the comfortable treatments and impressive results with minimal downtime.”The LaseMD ULTRA a high-power platform which provides a full range of applications in all skin types, including:Age spots (lentigos),
Sunspots (solar lentigos),
Freckles (ephilides),
Actinic Keratoses, and
Treatment of other benign pigmented lesions.Fractional Skin ResurfacingWrinkles - Laxity - Scar Reduction - Pigmentation - Melasma - Anti-Aging - Actinic Keratosis Excellent, Pre-Owned Condition
Serviced and Fully TestedMfr: Lutronic
Model: LaseMD PRO
S/N: LS115D047PS
Mfr Date: 06-19-2015LaseMDAdvanced skin resurfacing laser featuring the Thulium 1927nm wavelength, which focuses on coagulation rather than ablation.Suitable for all skin types.Cosmeceutical Delivery SystemLaseMD creates micro-channels in the skin to specific depths to delivery topical serums to the correct layer of the skin and increase absorption. It also features a built in centrifuge/incubator for LaseMD serum Ampoules.Optimized Magnetic Sensor Tracking Scanner Includes: 2015 Lutronic LaseMD Pro Fractional Skin Wrinkles
- LaseMD Workstation with Scanning Handpiece
- LaseMD Rolling Cart
- 2 Handpiece Caps
- FootSwitch Pedal
- System Key
- Power CableSpecifications:
Laser Type: Thulium
Wavelength: 1927nm | LUMENIS ACUPULSE 120 CO2 MACHINE
Includes:
Articulated Arm
2 Acuscan 120 Handpieces
125mm Incisional Handpiece
F-125 Attachments
KeySuperPulseTM TechnologyExceptional ablation/coagulation ratio.
Reach the desired treatment depth with a single pulse.
11 Built-in Treatment Modes.Maximum versatility with only two scanners.
Full parameter control for advanced users.
Short Pulse Duration.Enhanced patient comfort.
Lower chance of side effects.
Intuitive User Interface.Easy setup and quick treatments.
User presets for single-click treatments.11 Treatment Modes For Maximum Versatility
ACUSCAN120 FRACTIONAL SCANNERLUMENIS ACUPULSE 120 CO2 MACHINELaser Type:Co2
Wavelength:10,600 nm
AcuPulse
MultiModeTM SuperPulseTM CO2 Laser
AcuPulse is a complete ablative laser resurfacing workstation, featuring state of the art technology for all aesthetic resurfacing needs.
POWERFUL. VERSATILE. SIMPLE.Superficialfor moderate sun damage, fine lines, uneven texture, dyschromia, actinic keratosis and more.ComboDeep and Superficial combined together for sun damage, acne scars, wrinkles and more.Deepfor deeper lines and wrinkles, acne scars, uneven texture, dyschromia and more.StretchTouchfor skin furrows and textural irregularities.SURGITOUCH ADVANCED SCANNERFeatherTouchfor gental, single scan treatmentsToeTouchfor common foot ailments, such as plantar warts and ingrown toenailsSilkTouchfor more vigorous, double scan treatmentsPaintfor controlled, continous freehand placement on small areasFineTouchfor precise ablation of irregular pigmented lesions at various depths125MM INCISIONAL HANDPIECEBlephfor precise, clean incisions with minimal bleeding.Exceptional Ablation/Coagulation Ratio
When ablation depth is equal, more energy means more excess heat in the tissue. SuperPulse technology enables the deepest penetration with the lowest energy. This reduces patient discomfort, downtime and thermal damages.LUMENIS ACUPULSE 120 CO2 also enables shorter pulses, further enhancing patient safety. |
Reviews
There are no reviews yet.