| Description | Thanks to the unique technologies behind Legend Pro, patients experience minimal pain and downtime during and after treatment, without the need of numbing cream before the treatment. The desired results are promptly visible. Indications include: skin resurfacing and treatment of mild to moderate wrinkles and rhytids. | Advanced ergonomic handpiece with multi-spot, quick-zoom cartridges, and large touch screen GUI. | Includes:
Various Handpieces
1x 3 Button Fingerswitch Handpiece
1 Forcep
1 Infared Thermometer
1 Footswitch
1 Professional Cart
1 Suction Filter
1 Operator Manual
Brochures | 2017 Lumenis M22 with ResurFX & IPL in Like-New Condition; Manufactured 10/22/2017; Based Unit Serial Number 11860, IPL Handpiece Serial Number: 4751; Nd Yag Serial Number: Perfect Cosmetic and Operating Condition, Single Owner; Handpieces Included & Total Pulse Counts: IPL Handpiece Total Pulse Count = 908; ResurFX Handpiece Pulse Count = 16 Pulses; Includes Expert Filters: 515nm, 560nm, 590nm, 615nm, 640nm, 695nm, and 755nm; Also Includes: Footswitch, Interlock, Operator Manual. | Includes:
Articulated Arm
2 Acuscan 120 Handpieces
125mm Incisional Handpiece
F-125 Attachments
Key | 2017 Lumenis Lightsheer Desire with 3 Handpieces – HS, XC and ET – Includes 805 and 1060 nm wavelengths – Like-New Condition; Serial Number: 3796, Date of Manufacture 2/15/2017, Excellent Cosmetic and Operating Condition – Like New with low pulses! RECENTLY INSPECTED April 2021, Included Handpieces & Pulse Counts: HS 22×35 mm Spot Size Diode Handpiece = 132 Pulses; XC 12×12 mm Spot Size Diode Handpiece = 3,362 Pulses; ET 9×9 mm Spot Size 1060 Handpiece = 6,590 Pulses; Also Includes: Operator Manual, 2 Pair Operator Eyewear, 1 Pair Patient Eye Shields, (1) Key, and 120 Day Warranty |
| Content | Lumenis Pollogen Legend Pro 2020
Activating the body’s natural healing processes by applying RF-assisted ultra-thin electrodes to thermally ablate the epidermis, creating micro channels to induce controlled micro wounds, thus encouraging the generation of new and healthy skin.TriFractionalApplying contact RF and pin point ablation with controlled volumetric heating to achieve skin resurfacing and regeneration via wound healing process, resulting in skin texture improvement and refinement.M² unique synergized treatment combines the macro volumetric heating of tissue with TriPollar RF and the precise micro heating of focal points with VoluDerm RF assisted ultra-thin electrodes. Treatments with M² reaches multiple layers of the skin introducing a wide range of solutions for skin resurfacing and inducing regeneration as well as wrinkle reduction.Thanks to the unique technologies behind , patients experience minimal pain and downtime during and after treatment, without the need of numbing cream before the treatment. The desired results are promptly visible. Indications include: skin resurfacing and treatment of mild to moderate wrinkles and rhytids.IS AN ADVANCED MEDICAL AESTHETIC PLATFORM INCORPORATING THE LEADING INDUSTRY TECHNOLOGIES – HYBRID ENERGY TECHNOLOGY, TRILIPO USING NON-INVASIVE TRIPOLLAR RF ENERGY, AND DYNAMIC MUSCLE ACTIVATION. THE COMBINATION OF THESE TECHNOLOGIES PROVIDES EFFECTIVE DERMAL VOLUMIZING, SKIN TIGHTENING, AND BODY SCULPTING.Lumenis Pollogen Legend Pro Laser device is effective and fast with minimal discomfort. It is suitable for all skin types and ethnicities and carried out in a simple ‘walk-in walk-out’ treatment with minimal downtime.-Visible results after the 1st treatment-Long-term measurable results-Minimal discomfort, minimal downtime-Easy to use with a fast learning curveLumenis Pollogen Legend Pro Laser system intended for dermatological procedures requiring ablation and resurfacing of the skin when using VoluDerm Energy (Applicator VO). It is also intended for use in dermatologic and general surgical procedures for the non-invasive treatment of mild to moderate facial wrinkles and rhytides when using TriPollar RF Energy (Applicators 1-3)Specification : Lumenis Pollogen Legend Pro 2020Input Voltage:100-2400 Volt,50-60Hz, max 2.2A
Mode of Operation:VoluDerm, TriFractional, Tripollar
Maximum Output Power RF:50 Watts @ 200 Ohm
Maximum Output Voltage:100 Plus or Minus 10 Vrms
Output Frequency RF:1Mhz
Output Power Control RF:Pulse Width Modulation (PWM)
Weight: 66 Kgs
Dimensions:L1.5 x W1.5 x H3.6 Inch
Environmental Conditions for Operation
Temperature:15 Degrees Celsius to +30 Degrees Celsius (59-86 Degrees Farrenheit)
Relative Humidity:Up to 80%; Non- Condensing
Atmospheric Pressure: 70-106 kPa
Maximum Altitude:2000 Meters
Environmental Conditions for Transportation & Storage
Temperature:-20 Degrees Celsius to + 55 Degrees Celsius (-4-131 Degrees Farrenheit)
Relative Humidity:80%; Non-Condensing
Atmospheric Pressure:50-106 kPa
Maximum Altitude:2000 Meters | Lutronic Clarity II
Lutronic’s Clarity II is a high-powered, dual-wavelength platform that effectively delivers a wider range of parameters to help safely and efficiently treat the broadest indications with ease. The innovative design includes: a single fiber for all spot sizes(2-25mm), intuitive interface, and no need for calibration after any parameter change. Clarity II can save time and help facilitate faster, more effective treatments.
Higher power 755/1064nm platform for effective treatments up to 45%* faster.
Brilliantly removes hair, pigment, and vascular lesions in all skin types.
IntelliTrak technology and Temperature Sensing enable increased provider confidence and treatment efficacy.Clarity II
Key Feature
1. Powerful and faster
Provide up to 25mm spot size at a useable >2 Hz
High power performance
Up to 45% faster
2. Intelligent and convenientIntelliTraking system to prevent skip area and consistent treatment
Real time skin temperature monitoring system
3. Designed for versatilityIntelligent memory function to keep track of past treatment history in detail
Zoom cartridge system for treatment areaLutronic Clarity IIHow It Works
The CLARITY II Laser System contains two separate laser resonators, Alexandrite and an Nd:YAG, which generate pulse laser energy at the nominal wavelength of 755nm and 1064nm respectively. The output of each laser generator and the 515nm aiming beam are optically combined on the laser rail so that their beam paths are identical as they exit the laser system. This allows the use of a single delivery system for either the 755nm or 1064nm wavelength.Clarity II
with IntelliTrak technologyHigher-powered 755/1064nm platform laser
Up to 2X faster Laser Hair Removal Txs*
Exclusive shorter pulsewidths available including 1ms setting
for finer facial hairs
Breakthrough intelligent capabilities
IntelliTrak technology for faster more consistent Tx coverage
Temperature Sensing for real-time skin temp feedback
during Tx
Auto-calibration in seconds saves time and
improves productivity
Advanced, easy-to-use platform
Single fiber for all 2-24mm spot cartridges
Numerous skin rejuvenation capabilities including vascular,
pigment, and toning Txs
*At settings of: 755nm, 5ms, 12J/cm2: Clarity II at 22mm, 3Hz, IntelliTrak at 18% overlap vs.
older system at 18mm, 2Hz, and est. ~18% manual overlap. Geometric treatment coverage speed is
11.4cm/second with Clarity II vs. 5.1cm/second with older system. | ELLMAN PELLEVE S5 REDUCTION SYSTEM
The Pelleve S5 System is a new generator based on the proven Surgitron technology. In addition to powering the Pelleve handpieces, it provides maximum control in precision cutting with minimal thermal damage to surrounding tissues, plus more versatility than other energy-based technologies, including:Wrinkle reduction treatment with the new GlideSafe(TM) handpieces
Hundreds of surgical electrodes and accessories for most specialties
Portable and light weight – ideal for office and clinic environmentsWxHxD: 9.5 x 7.1 x 16.5
Weight: 26 lbs.
Ambeint Temperature: +10 degrees C – +40 degrees C
Relative Humidity: 30% – 75%
Normal Line Voltage: 100V, 120V / 220V, 240V – + 10%
Line Frequency: 60Hz./50Hz.
Input current at max output power: 3.4A/1.5A
Pelleve Wrinkle Reduction System
Ellagance Through Science
Pelleve S5 SystemPelleve precisely delivers energy to the dermal tissue using advanced radiofrequency technology to induce collagen contraction without damaging the epidermis. The result is skin tightening and contouring with a noticeable improvement in skin quality and texture.Pelleve’s unique radiofrequency technology emits energy in the form of electromagnetic waves, which create a heated treatment zone. Increased resistance causes heat buildup at the subdermal junction. Heat induces collagen denaturation and collagen contraction. Protein stimulation causes new collagen formation and production in the dermis which also results in epidermal tightening. Existing bands of collagen tighten in subcutaneous fat, creating a superficial tightening of the epidermis.Unparalleled Safety ELLMAN PELLEVE S5 REDUCTION SYSTEM
The Pelleve System delivers continuous radiofrequency energy which enables the clinician to choose how much energy to deliver and in what areas. By using a combination of the different sizes of Pelleve handpieces that are available each patient’s specific areas of concern can be addressed, resulting in patients receiving just the right amount of energy. The new GlideSafe handpieces feature an innovative sensor designed to stop energy flow when the device senses loss of contact with skin, further enhancing the safety.Non invasive, non ablative office treatment
Patients today are seeking affordable, non invasive alternatives to ablative and surgical procedures. The Pelleve System fills that void.Minimal side effects
A Pelleve treatment is virtually pain free and no anesthetic is used for the treatment. The patient may experience some transient erythema or edema, which is typically gone in a few hours.PelleFirm is a non-invasive cellulite treatment that uses radiofrequency energy and massage to deeply heat tissues and temporarily reduce the appearance of cellulite.ELLMAN PELLEVE S5 (TM) HandpiecesPelleve GlideSafe handpieces feature an innovative sensor designed to stop energy flow when the device senses loss of contact with skin – resulting in a more comfortable treatment for the patient. The GlideSafe Handpieces are available in 4 sizes – 7.5 mm, 10 mm, 15 mm, 20 mm – to allow the physician clinician to customize to the individual patient. The compact ergonomic design enables practitioners to comfortably maneuver around the contours of the face, including areas that are difficult to access such as the periorbital region. Each handpiece delivers multiple hours of treatment (activation) time so doctors have the option of customizing each patient’s treatment by using different size handpieces for different areas of the face. This advanced feature allows users to treat multiple patients and perform many procedures using the same charged handpiece.Surgical Versatility
An innovative multi-modality system, the Pelleve Wrinkle Reduction System offers physicians unmatched versatility in a compact design. Beyond skin tightening, the ELLMAN PELLEVE S5 platform facilitates scores of procedures with the availability of hundreds of monopolar and bipolar electrodes.Skin tightening plus surgical procedures
You can use the Pelleve system to deliver aesthetic treatments plus surgical treatments with the S5 platformAdds value to your practice
An ideal procedure to delegate to physician extenders and bundle with other servicesPractice profitability
Low operating costs yield enhanced profitability relative to treatment feeWide range of surgical electrodesFor use with the Pelleve Generator and all other Ellman generators are hundreds of standard and specialty surgical electrodes facilitate procedures ranging from minimally invasive treatments through full surgical procedures. Unlike conventional ESU generators, the Ellman generators are high-frequency radiofrequency devices that enable precise cutting and control with minimal thermal damage. Minimizing tissue damage improves aesthetic outcomes and reduces recovery time. | 2017 Lumenis M22 IPL with ResurFX| Manufacturer Notes |
|---|
| M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal.Available Treatments with M22:– Acne Scar Treatment
– Hair Removal
– Non-Ablative Skin Resurfacing
– Photorejuvenation
– Pigmentation Treatment
– Scar Revision
– Vascular / Leg Vein Treatment
– Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge.Universal IPL
Optimal Pulse Technology (OPT)
Single handpiece with changeable filters and lightguides
For IPL skin treatments using photorejuvenationResurFX
The only True fractional non-ablative, with CoolScan scanner
No disposables
For skin resurfacingMulti-Spot Nd:YAG
The only one with Multiple Sequential Pulsing (MSP)
2 sized lightguides, changeable in seconds
For treatment of leg veins and vascular lesionsQ-Switched Nd:YAG
Homogenous beam profile for enhanced treatment safety and efficacy
For skin toning*, dark tattoos removal, and combination treatments
*Skin toning by treatment of pigmented lesions |
2017 Lumenis M22 IPL with ResurFX and Q-Switched Nd:YAG A modular multi-application system for hair removal and various skin conditions Details:M22 Serial Number: 21171 M22 Date of Manufacture: 2017-07-17 Total IPL Pulses: 19,186 Total ResurFX Pulses: 10,772 Q-Switched Nd:YAG Pulses: 385,505
Includes:IPL Handpiece Complete Standard IPL filters: 515, 560, 590, 615, 640, 695, 755nm, and Calibration Specialty IPL Filters: Acne and Vascular IPL Light Guides: (1)35 x 15 mm2; (1)15 x 8 mm2, (1) 6mm- round ResurFX Handpiece with SapphireCool Tip Q-Switched Nd:YAG Handpiece Foot Switch Power Cord 30 Days Parts and Labor Warranty
|
System specifications
Dimensions:[without ResurFX] 44 x 50.5 x 47 cm (17 x 20 x 18.5 inches)
Dimensions:[with ResurFX] 44 x 50.5 x 61.5 cm (17 X 20 X 24 inches)
Weight:[without ResurFX] 40 kg / 88 lbs
Weight:[with ResurFX] 55 kg / 121 lbs
Electrical requirements:100 240 VAC ±10%, 15A max., 50/60 Hz, single phase, dedicated line M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal. Available Treatments with M22:– Acne Scar Treatment
– Hair Removal
– Non-Ablative Skin Resurfacing
– Photorejuvenation
– Pigmentation Treatment
– Scar Revision
– Vascular / Leg Vein Treatment
– Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge. Universal IPL
Optimal Pulse Technology (OPT)
Single handpiece with changeable filters and lightguides
For IPL skin treatments using photorejuvenation ResurFX
The only True fractional non-ablative, with CoolScan scanner
No disposables
For skin resurfacing Multi-Spot Nd:YAG
The only one with Multiple Sequential Pulsing (MSP)
2 sized lightguides, changeable in seconds
For treatment of leg veins and vascular lesions | LUMENIS ACUPULSE 120 CO2 MACHINE
Includes:
Articulated Arm
2 Acuscan 120 Handpieces
125mm Incisional Handpiece
F-125 Attachments
KeySuperPulseTM TechnologyExceptional ablation/coagulation ratio.
Reach the desired treatment depth with a single pulse.
11 Built-in Treatment Modes.Maximum versatility with only two scanners.
Full parameter control for advanced users.
Short Pulse Duration.Enhanced patient comfort.
Lower chance of side effects.
Intuitive User Interface.Easy setup and quick treatments.
User presets for single-click treatments.11 Treatment Modes For Maximum Versatility
ACUSCAN120 FRACTIONAL SCANNERLUMENIS ACUPULSE 120 CO2 MACHINELaser Type:Co2
Wavelength:10,600 nm
AcuPulse
MultiModeTM SuperPulseTM CO2 Laser
AcuPulse is a complete ablative laser resurfacing workstation, featuring state of the art technology for all aesthetic resurfacing needs.
POWERFUL. VERSATILE. SIMPLE.Superficialfor moderate sun damage, fine lines, uneven texture, dyschromia, actinic keratosis and more.ComboDeep and Superficial combined together for sun damage, acne scars, wrinkles and more.Deepfor deeper lines and wrinkles, acne scars, uneven texture, dyschromia and more.StretchTouchfor skin furrows and textural irregularities.SURGITOUCH ADVANCED SCANNERFeatherTouchfor gental, single scan treatmentsToeTouchfor common foot ailments, such as plantar warts and ingrown toenailsSilkTouchfor more vigorous, double scan treatmentsPaintfor controlled, continous freehand placement on small areasFineTouchfor precise ablation of irregular pigmented lesions at various depths125MM INCISIONAL HANDPIECEBlephfor precise, clean incisions with minimal bleeding.Exceptional Ablation/Coagulation Ratio
When ablation depth is equal, more energy means more excess heat in the tissue. SuperPulse technology enables the deepest penetration with the lowest energy. This reduces patient discomfort, downtime and thermal damages.LUMENIS ACUPULSE 120 CO2 also enables shorter pulses, further enhancing patient safety. | Lumenis Lightsheer Desire (Include Handpiece)
comes fully loaded with 3 handpieces – ET (9X9), XC (12X12) & HS (22X35)the LightSheer DESIRE uses an 805nm diode wavelength. This wavelength is the industry’s Gold-Standard and has been clinically proven to safely and effectively treat all skin types Available Treatments: - Hair removal, permanent hair reduction, and the treatment for Pseudofolliculitis Barbae(PFB).
- Treatment of vascular lesions, including angiomas, hemangiomas, telangiectasia, leg veins and other benign vascular lesions.
- Treatment of benign pigmented lesions.
Unique features: - The “Gold standard” 805nm diode laser.
- 3 handpieces with various spot sizes.
- 2 advanced technologies.
The ET has a Sapphire ChillTip spot size of 9x9mm designed to treat small areas that require maximum precision and high fluence.The XC has a Sapphire ChillTip spot size of 12x12mm, providing optimal solution for large and small areas requiring higher fluence levels.The HS has a HIT 22x35mm spot size enabling use of low-fluence and a unique mechanism of pain reduction, providing safe, fast and comfortable treatment. | Product Specifications |
|---|
| ET | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 9 mm X 9 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 Pulse | | Fluence | 10-100 J/cm2 | | Pulse Width | 5-400 ms | | Peak Power | 1600 W | | Comfort Management | Chilltip contact cooling (5O C) | | Preset Parameters | Yse |
| XC | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 12 mm X 12 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 Pulse | | Fluence | 10-40 J/cm2 | | Pulse Width | 5-400 ms | | Peak Power | 2400 W | | Comfort Management | Chilltip contact cooling (5O C) | | Preset Parameters | Yse |
| HS | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 22 mm X 35 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 – 3 pulses | | Fluence | 4.5-12 J/cm2 | | Pulse Width | 30-400 ms | | Peak Power | 2300 W | | Comfort Management | Vacuum assisted (up to18inHg) | | Preset Parameters | Yse |
Lumenis Lightsheer Desire (Include Handpiece) – Like New |
Reviews
There are no reviews yet.