| Description | The SONIMAGE HS1 Compact Ultrasound System has advanced MSK functionality providing superior image detail and contrast resolution. The advanced technological features and high resolution image quality supports confident diagnosis, needle guidance for interventional procedures and treatment management at the point-of-care. | Laser Hair Removal
Details:- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| eTwo combines the unique Sublime and Sublative applications for comprehensive facial rejuvenation in as little as one treatment.
Sublime uses the elos combination of safe and effective levels of bi-polar radio frequency energies and infrared light to remodel the deep dermal layer of the skin by stimulating new collagen growth.
Sublative fractionated bi-polar radio frequency technology places the heat energy effectively into the upper dermis where it can significantly increase both collagen and elastin with minimal epidermal disruption. | Highest available power allows for fast treatments, customizable for multiple areas
Gentle, effective global improvement for all skin types, all year-round
Comfortable treatments with very little downtime
Minimal cost of ownership, easy to delegate and no shot limit per procedure | The PURE+ is offered in two configurations:FSR + TC: Fixed FSR handpiece + one exchangeable connector suitable for all TC handpieces: iFine, Small and Large
TC Complete: Two exchangeable connectors on each side, suitable for all TC handpieces: iFine, Shaper, Small and LargeThe iFine treatment Handpiece –
specially engineered to target fine lines and wrinkles found in the delicate thin skin areas around the eyes, providing:
Smoother, tighter skin around the eyes.
Reduced under eye sagging and improved eye contour.
Reduced hooding to reveal more of the eyelid.
More youthful, less tired looking eyes.
Softening of fine line enabling easier application of make-up. | 2015 Active Optical Extra 818 IPL Hair Removal and Skin Rejuvenation; Excellent Cosmetic and Operating Condition, Very Lightly Used for Demonstrations Only, Single Owner; Included Handpieces and Pulse Counts: Hair Removal Handpiece = 6,617 Pulses, Facial Handpiece = 2,190, Life for Each Handpieces is 250,000 Pulses. |
| Content | Konica Minolta Sonimage HS1 Portable Ultrasound MachineKONICA MINOLTA SONIMAGE HS1 PORTABLE ULTRASOUND MACHINE Like New.We bought this unit last year for our office but we never got to use on patients . So it’s basically new. It has all the bells and whistles fully loaded with needle guidance and 18 MHz probe for ultimate ultrasound pictures. Also includes 14 MHZ probeSONIMAGE HS1Superior Image Quality (T2HI)Innovative designIntuitive user interfaceSimple Needle Visualization (SNV) technologyHand-carried ultrasound system designed for youThe SONIMAGE HS1 is a Point-of-Care portable ultrasound system designed to support a wide range of applications and patient types. The system's advanced technologies ensure superior image quality and efficient workflow.Hand-Carried UltrasoundSee full detailsSimple Needle VisualizationUnlike conventional beam-steering technology, SONIMAGE HS1 incorporates an algorithm that utilizes two techniques—in-plane and out-plane—to improve needle visualization; this is especially important in steep angle approaches. The result is depiction of the needle tip that eliminates the need to position the ultrasound probe perpendicular to the needle, which is not always attainable due to patient positioning requirements or demanding clinical environments. The resulting needle conspicuity helps enable effective procedures.Flow Pixel CounterThe Flow Pixel Counter (FPC) provides the information of proportion of blood flow signals presented within a region of interest (ROI) as a general measurement for 2D-mode. FPC can be used to calculate the ratio of a specific ROI to the area of specific blood flow signals presence. As such, it is a useful tool for evaluating new blood vessels within a tumor or inflammation of the synovial membrane in rheumatoid patients. Still under full warranty.High-resolution probeThe best-in-class L18-4 linear transducer provides the high image quality required for penetrating deep tissue to view the muscles, tendons, and nerves for musculoskeletal evaluations or pain management applications. The unique, lightweight design is big on image quality for fast and clear depiction of structures, enhancing clinical confidence at the point of care.Ergonomic designA keen focus on ergonomic design combined with ease of use and flexibility to enhance patient management. The SONIMAGE HS1 is built for virtually any healthcare environment—it can be used on a cart or desktop.WorkflowA sleek, compact, and a simple click interface for data distribution provides exceptional economic value across a variety of healthcare environments—from the clinic to the bedside. With seamless connectivity via DICOM to the ImagePilot or other information systems, the SONIMAGE HS1 provides an array of workflow options to meet your current needs and allow for future growth.Main Unit SpecificationsWarranty: 5 yearsMode: B, M, Color, Power, PWDMonitor: 15 inch IPS type monitorDimensions (folded monitor): W 369 x D 452 x H 90Power Supply: AC100 – 240V max 180 VAWeight: 17.2 lbs (including battery )Probe SpecificationsType: Linear probe L18-4 (optional to L14-4)Bandwidth: 4 - 18 MHzField of view: 38 mm | 2019 Lumenis Splendor X- Laser Hair Removal
Lumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthThe Lumenis Splendor X has been introduced to be a player in the solid state Nd:YAG and Alexandrite laser hair removal market. The gold standard for hair removal has always been considered Alexandrite 755nm for light skins and Nd:YAG 1064nm for dark skins.The Lumenis Splendor X combines both in a unique way with blended emission.Instead of firing a single wavelength at a time the Splendor X allows you to fire both wavelengths simultaneous in adjustable amounts to suit the skin type and hair types. This means you are target multiple chromophores at any given time given enhanced results across the board.The Lumenis Splendor X also allows the user to choose between square and round spot sizes with large spot sizesLumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthLaser Hair Removal
Details:2019 Lumenis Splendor X- Laser Hair Removal- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| Syneron Candela eTwo LaserComplete Facial Rejuvenation using the eTwoeTwo combines the unique Sublime and Sublative applications for comprehensive facial rejuvenationThe Sublime treatment combines safe and effective levels of infrared light and bipolar radiofrequency energies to remodel the dermal layer of the skin by stimulating new collagen growth.The Science of Sublime
Sublime uses the elos combination of IR and Bi-Polar RF to provide controlled deep dermal heating. This predictable heating of the deep dermis both stimulates and shortens aged collagen fibers, resulting in the immediate and long term improvement of wrinkles and facial contour.The ergonomic Sublative applicator delivers bipolar radio frequency energy via a matrix of 64 electrodes in the disposable applicator tip. The RF energy generates fractional deep dermal heating in the region of the electrode matrix to induce skin injury, thus eliciting a wound healing response. Mild to moderate wrinkles and superficial skin discoloration are reduced, and skin texture becomes more smooth and elastic.The Science of Sublative
The unique Sublative ergonomic applicator delivers bi-polar radio frequency energy via the matrix of electrodes of the disposable Sublative iD. This fractional delivery of RF energy causes micro-epidermal ablative injuries with wider spread dermal coagulation. This initiates a strong wound healing response in the dermal matrix while also minimizing the damage to the epidermis. Less affected tissue surrounding the matrix points may be stimulated by heat which helps accelerate the healing process, leading to a smoother, rejuvenated appearance of the skin.Visible Results, Low DowntimeIntelligent Feedback SystemReal time information on skin condition, impedance and the energy delivery of each pulseMinimal downtime
Safe & effective for all skin types
Quick treatments: typically 20 – 40 min
Short treatment protocol
Lightweight, compact, multi-applicator platform
Easily transports between practice locationseTwo combines the unique Sublime and Sublative applications for comprehensive facial rejuvenation in as little as one treatment.
Sublime uses the elos combination of safe and effective levels of bi-polar radio frequency energies and infrared light to remodel the deep dermal layer of the skin by stimulating new collagen growth.
Sublative fractionated bi-polar radio frequency technology places the heat energy effectively into the upper dermis where it can significantly increase both collagen and elastin with minimal epidermal disruption. | 2015 Lutronic LaseMD Pro Fractional Skin Wrinkles
Lutronic LaseMD Ultra Laser is an impressive upgrade to their already successful LaseMD,” shared Steven Weiner, MD, from Lutronic.“Not only is it more powerful (20 watts vs 12 watts) but it also has a significantly lower consumable cost than competitive systems. The LaseMD ULTRA offers a new larger spot size and incorporates improved ‘top hat’ beam profile. The system also offers an incredibly advanced graphical user interface.“The integration of all the new features with real-time information helps reduce treatment time and achieve satisfying patient results in fewer treatments. Since no anesthesia is required, I can treat a full face in about 6-8 minutes or treat the face, neck and chest in 20 minutes.”Lutronic LaseMD Ultra Laser is yet another example of Lutronic’s commitment to Intelligent Design for Intelligent Care, according to the company in a media release. Features include:Highest available power allows for fast treatments, customizable for multiple areas
Gentle, effective global improvement for all skin types, all year-round
Comfortable treatments with very little downtime
Minimal cost of ownership, easy to delegate and no shot limit per procedure“LaseMD ULTRA is my favorite new addition to my practice. It allows me to treat multiple areas quickly, effectively and for very low cost,” adds Joel Cohen, MD, in the release. “My patients love the comfortable treatments and impressive results with minimal downtime.”The LaseMD ULTRA a high-power platform which provides a full range of applications in all skin types, including:Age spots (lentigos),
Sunspots (solar lentigos),
Freckles (ephilides),
Actinic Keratoses, and
Treatment of other benign pigmented lesions.Fractional Skin ResurfacingWrinkles - Laxity - Scar Reduction - Pigmentation - Melasma - Anti-Aging - Actinic Keratosis Excellent, Pre-Owned Condition
Serviced and Fully TestedMfr: Lutronic
Model: LaseMD PRO
S/N: LS115D047PS
Mfr Date: 06-19-2015LaseMDAdvanced skin resurfacing laser featuring the Thulium 1927nm wavelength, which focuses on coagulation rather than ablation.Suitable for all skin types.Cosmeceutical Delivery SystemLaseMD creates micro-channels in the skin to specific depths to delivery topical serums to the correct layer of the skin and increase absorption. It also features a built in centrifuge/incubator for LaseMD serum Ampoules.Optimized Magnetic Sensor Tracking Scanner Includes: 2015 Lutronic LaseMD Pro Fractional Skin Wrinkles
- LaseMD Workstation with Scanning Handpiece
- LaseMD Rolling Cart
- 2 Handpiece Caps
- FootSwitch Pedal
- System Key
- Power CableSpecifications:
Laser Type: Thulium
Wavelength: 1927nm | ENDYMED PURE PLUS Input Power:100-120V, 50-60Hz, 2A or 220-240V, 50-60Hz, 1A
Power Consumption:220 W
Fuses:2 x 1.6A for 220V; 2 x 3.15A for 110V
Output Power:Up to 50 Watts
Output Frequency:1MHz
Working Temperature:+10°C – +25°C
Dimensions:(H x W x D) 600 x 305 x 365 mm
Weight:10 kg
GOOD THINGS COMES IN SMALL PACKAGES THE PURE+
The Pure+ by Endymed Pure Plus, powered by our FDA cleared, patented 3DEEPRF technology. The PURE+ offers professional grade Fractional Skin Resurfacing and superior body, facial and neck tightening and contouring treatments, all on one easy to use, compact platform. The PURE+ offers complete flexibility with exchangeable treatment handpieces one PURE+ console can be configured any way you like to provide you and your clients with the most effective and popular treatments available today.The PURE+ is offered in two configurations:FSR + TC: Fixed FSR handpiece + one exchangeable connector suitable for all TC handpieces: iFine, Small and Large
TC Complete: Two exchangeable connectors on each side, suitable for all TC handpieces: iFine, Shaper, Small and LargeThe iFine treatment Handpiece –
specially engineered to target fine lines and wrinkles found in the delicate thin skin areas around the eyes, providing:
Smoother, tighter skin around the eyes.
Reduced under eye sagging and improved eye contour.
Reduced hooding to reveal more of the eyelid.
More youthful, less tired looking eyes.
Softening of fine line enabling easier application of make-up.3Deep Small-Medium Handpiece
Designed to treat wrinkles and lax skin on the face, neck and upper body.3Deep Fractional Skin Resurfacing Handpiece
Specially designed for fractional skin resurfacing and treatment of skin roughness, hyperpigmentation, and wrinkles and scars on both facial and body. The FSR handpiece contains a matrix of 112 tiny electrodes, allowing for the first time simultaneous fractional micro-ablation of the epidermis, together with volumetric heating of 100% of the dermis. This technology provides the capability to differentiate between micro-ablation and dermal heating which appears to be the optimal multi-layer treatment to affect aging skin and atrophic acne scars.3Deep Shaper Handpiece
Major innovation in RF skin tightening, body shaping and contouring, and cellulite treatment for large body areas. The handpieces unique engineered electrode surface is 40.7 cm2 allowing for shorter treatment times (20 minute abdomen treatment, 30 minute cellulite treatments for the thighs and buttocks). Deeper, controlled energy penetration tightens and firms the skin by stimulating the bodys natural collagen renewal process, providing better and more effective results. | Active Optical Extra 818 IPL Hair Removal 2015Handpieces:Hair Removal Handpiece and Facial Handpiece
Chilled Tip:Up to 4c
Pulse Interval:0.5~2 Seconds
Output Power:11-31 joule/cm2, upto 4,000W
Cooling System:Revolutionary dual cooling
Control:Intuitive touch screen control
Lamp’s Life Span:250,000 Flashes (Universal), 200,000 Flashes (Facial)
Treatment Area:7.5 cm2 (15*50mm) Universal, 4.5 cm2 (15*30mm) Facial
Wavelength:420-1100 nm
Weight:42Kg (including Stand, if device is not a table top)
Dimensions:44cm x 45cm x 100cm Extra-818Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Vascular (Facial) TreatmentThe Extra – 818 is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features:
* Contemporary touch screen control
* Built-in Patch Test procedure for examining the optimal energy level
* A stunning number of 450,000 flashes in both lamps.The Extra – 818, based on Active’s GEM-PL technology, sets sets a specific Pulse Pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth.
The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.The combination of tested treatment protocols with high end engineering makes the Extra – 818 the perfect device for leading clinics.Revolutionary Cooling System
The Extra – 818 has a dual cooling system, controlled and monitored in order to ensure long lifetime to the lamp and a comfortable treatment to the patient.Competitive cooling systems “freeze” the skin so that during the treatment the skin temperature will rise to a bearable level. However, this “freezing” temperature might limit the results because the follicles will not reach the coagulation temperature. To ensure optimal results Active installed a special Processor that prevents overcooling the skin and maintains a uniform low temperature of the “glass” throughout the treatment. This revolutionary system enables the Extra – 818 to provide best results with optimal patient comfort.Research Program Active Optical Extra 818 IPL Hair Removal 2015
For clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device.
The energy levels in the self setting program can reach 31Jcm2 with high intensity of 4,000W. |
Reviews
There are no reviews yet.