| Description | As one of the most user-friendly Cone Beam Computed Tomography (CBCT) systems on the market, the 9000 3D Extraoral Imaging System offers several versatile solutions for your extraoral imaging needs. Combining focused-field 3D technology with dedicated panoramic imaging, this affordable 2-in-1 unit delivers the best of both worlds, offering the highest resolution and the lowest radiation dose. | Mr Blue 2.0 is on the cutting edge of innovation – serving as a genuine ECP partner since its launch. Now featuring a whole range of new functions and even greater flexibility, Mr Blue is the perfect solution for demanding workshop. | The image can then be displayed on a monitor, helping you to educate your patients The HRK can provide peripheral keratometry measurement data which is very useful when fitting contact lenses. The eye can be displayed in full colour mode on a tilting touch screen which enables you to see the patient’s contact lens fitting status, previously only possible using a slit lamp. As the HRK has the world’s first contact lens fitting function in an auto keratometer, you can now see the flourescein liquid with blue illumination along with automatic calculation and recommendation for contact lens fitting. | New Carestream Dental Intraoral Scanner Announced – the CS 3800A wireless intraoral scanner with high-performance experience | Treatments offered with the InMode OptimasMorpheus8- Skin Resurfacing and RejuvenationLumecca IPL – Age spot and sun spot treatmentForma – Skin remodeling at its bestAvailable Handpieces:
LUMECCA
FORMA
FRACTORA
DIOLAZEXL
VASCULAZE
VLAZE
MORPHEUS8LUMECCA
Fastest IPL Results*
*Clearance in 1-2 sessions, compared to 4-5 sessions with competing devices | CIRRUS HD-OCT 5000 is configured with the highest resolution visualization capabilities and sophisticated clinical applications such as Advanced RPE analysis to track retinal pigment epithelial integrity and Ganglion Cell Analysis to assess glaucomatous loss in the macula that may not be evident in the peripapillary region. The new FastTrac retinal tracking reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning. This feature enables the highest resolution B-Scans to be captured in identical locations from visit to visit providing precise assessment of change in targeted pathologies. |
| Content | Kodak 9000 3D Extraoral Imaging System
Add cephalometric imaging abilities to your 9000 3D System for even more abilities. Through our revolutionary one-shot technology, cephalometric image acquisition takes less than a second—thereby reducing exposure time and the risk of retakes due to patient movement. With the 9000C 3D System, you can perform a wider range of diagnoses and treatments right in your office, rather than referring patients to imaging centers. Reduce multiple visits, prevent rescheduling issues, and enhance patient care with three versatile imaging abilities right at your fingertips: panoramic, cephalometric, and 3D imaging.Superb image quality, all three modalitiesVariable focal trough adapts to patient’s jaw morphology – generating high-quality, true panoramic images Best-in-class cephalometric image quality with reduced risk of motion blur Ultra-high resolution, low-dose, focused-field CBCT images provide superior visualization of fine bony anatomy, such as radicular structures
Optimized for radiology workflowsDR technology reduces exam time and eliminates steps, such as film processing and cassette handling One-shot cephalometric technology captures images in less than a second, reducing exam time and risk of retakes Dedicated sensors for each modality save technologist time, reduce risk of breakage DICOM conformance ensures easy integration with PACS, RIS, and printing systems
Simple by design Kodak 9000 3D Extraoral Imaging SystemStreamlined user interface, preset programs and face-to-face positioning makes exams quick and simple Accommodates patients of all shapes and sizes and wheelchair accessible Intuitive, easy-to-use imaging software with improved features for reviewing, reporting and sharing images Includes a comprehensive implant planning model to help referring dentists identify exact measurements and create simulations of proposed treatments
A trusted company, proven productsProven product reliability – even in demanding, high-volume environments Broad range of Carestream equipment and professional services such equipment service agreements, site planning and DICOM integration services. - One-stop shopping for digital imaging and IT solutions from a company with over a century of medical and dental imaging expertise
| Panoramic Modality | Cephalometric Modality | Cone Beam CT Modality | Technology CCD – Optical | CCD – Optical Fiber Sensor | One-Shot with CCD Sensor with Optical Fiber | Cone Beam with CMOS Sensor with Optical Fiber | Gray Scale | 14 bit | 14 bit | 15 bit | 3D Field-of-View | n/a | n/a | • Single Volume: 5 cm x 3.75 cm • Stitched Volumes (up to 3): 9 cm x 7 cm x 3.75 cm | Exam Options | • Panoramic • Child Mode • Segmented Panoramic • Maxillary Sinus • LA TMJ x 2 • LA TMJ x 4 | • Cephalometric • Lateral • Oblique • Frontal (AP/PA) • Submento-Vertex • Carpus • Multiple Cephalometric Field Choices: 30 x 30, 24 x 30, 24 x 24, 18 x 24, 18 x 18 | • CBCT • Resolution Options: 76, 100, or 200 micrometers • Location of Exam: User-defined (mandible, maxilla, TMJ) | Input Voltage | 230/240 V – 60 Hz | 230/240 V – 60 Hz | 230/240 V – 60 Hz | Tube Voltage | 60-90 kV (max) | 60-90 kV (max) | 60-90 kV (max) | Tube Current | 2-15 mA (max | 2-15 mA (max | 2-15 mA (max | Frequency | 140 kHZ (max) | 140 kHZ (max) | 140 kHZ (max) | Total Filtration | > 3.5 mm eq. AL | > 3.5 mm eq. AL | > 3.5 mm eq. AL | Weight | 353 lb (160 kg) | 438 lb (199 kg) | 353 lb (160 kg) |
| Essilor Mr Blue 2.0 Lens Edgers and TracerComplete Control of Lens Mounting
- Optimal monitoring of all trajectories, irrespective of finishing materials or shapes
- Absolute axis control thanks to hybrid edging technology: grinding + milling
- Ideally suited for quality finishing even on highest base curves
- Fast and accurate drilling with data acquired in a single operation
- Automatic centering and blocking for simple operation
Unrivalled Ergonomics- Completely integrated functions without external peripheral devices
- Vertical architecture with <Heads-up displays> for optimum comfort
- Storage features ensure all accessories are within reach.
- Intelligent interface adapts to the way you work.
Highest Quality Guaranteed Essilor Mr Blue 2.0 Lens Edgers and TracerPerfect Centering- Binocular 3-D tracing of full-rim frames up to base 9*
- Automatic adjustment of centering data based on the frames’ 30D parameters*
Aesthetic and Robust Mountings- FIT-4-Frame technology with dedicated small wheel*
- Drilling and grooving tools can be tilted up to 30o, making it safe to mount lenses of up to base 10. *Essilor patents and exclusives
Safe Process- Roughing cycle automatically adapts to the curves of lenses up to base 10, avoiding all risk of breakage
- Bevel placement and shelf depth optimized for safe mounting without undue stress of lens
Aesthetically Pleasing and Easy-to-Mount Bevels- The bevel heights are adjustable to perfectly adjust to the thinnest grooves
- The shelf bevel heights are optimized to follow the frame’s shape perfectly
- The step bevel is particularly suited for sport eyeglasses with deep, rectangular or uneven groove profile
Mr Blue 2.0 is on the cutting edge of innovation – serving as a genuine ECP partner since its launch. Now featuring a whole range of new functions and even greater flexibility, Mr Blue is the perfect solution for demanding workshop. | Huvitz HRK-8000A Auto Refractor KeratometerHuvitz Auto Ref – Keratometer HRK-8000A- Touch and tilting 7″ LCD Screen that allows for free and smooth tilting for viewing at any angle.
- Optimized Optical System
- Micro Lens Array
- Aberration Measurement which also can be displayed in a graphical Zernike Refraction Map
- PSF & Image Simulation
- Colour View Mode
- Peripheral Keratometry Measurement
- Ultra High Precision KER Data
- Contact Lens Fitting Assistance Guide
- Contact Lens Prescription Guide
- Auto Tracking
- Animated Guide
- Faster Measurement Speed
- Quiet and speedy auto cutting printer
- More data on aberration measurement
With its extreme precision and accuracy, the HRK8000A uses the most advanced wavefront technology to measure the light reflected from the retina and helps you to diagnose any refractive error. With a micro lens array developed by Huvitz, the HRK creates a number of focal points, the pattern of which can give a valuable insight into the patients ocular system. The HRK not only displays the conventional data such as spherical, cylinder and axis, the high order aberration data is displayed in a graphical Zernike refractive map, giving you a deeper understanding of your patient’s eyes.Optimized Optical System Huvitz HRK-8000A Auto Refractor Keratometer
A wavefront is a physical representation of the optical quality of a light beam. Using various methods, aberrometers map how light rays travel through the eye. The HR-8000A is engineered according to the Hartmann-Shack wavefront measurement technique, which is widely preferred for its speed and repeatability.Touch & Tilting Color Display Screen
A bright, high contrast 7″ VGA color TFT LCD screen provides high resolution video images. A smooth, free tilting function also offers you a comfortable and clear view at any angle.The image can then be displayed on a monitor, helping you to educate your patients The HRK can provide peripheral keratometry measurement data which is very useful when fitting contact lenses. The eye can be displayed in full colour mode on a tilting touch screen which enables you to see the patient’s contact lens fitting status, previously only possible using a slit lamp. As the HRK has the world’s first contact lens fitting function in an auto keratometer, you can now see the flourescein liquid with blue illumination along with automatic calculation and recommendation for contact lens fitting. | Carestream CS 3800 Dental Intraoral Scanner
With CS 3800, the time has come to restore your liberty.The CS 3800 offers dental practitioners a whole new experience in acquiring impressions: freedom. Freedom from cables, freedom to pursue their preferred workflow, freedom to pay only for what they use, and freedom to interact with their partners, how they prefer, when they prefer. And, as the result of a renewed collaboration with Studio F. A. Porsche, the CS 3800 displays a timeless, ergonomic design that ensures a high-performance scanning experience.Benefits at a glance Carestream CS 3800 Dental Intraoral Scanner- High-performance wireless intraoral scanner for optimal mobility and seamless user experience
- One of the lightest and most compact intraoral scanners of the market
- Faster and smoother scanning thanks to a larger and broader field of view and a deeper field of view
- Full control of intraoral capabilities right on the handpiece
- Ergonomic design by Studio F. A. Porsche
A renewed feat with Studio F. A. PorscheThe CS 3800 intraoral scanner is the result of an ongoing collaboration with Studio F. A. PorscheThis time, the design firm moved towards the idea of designing the scanner with optimal comfort based on the morphology of the human hand combined with fluid and organic lines. The handpiece is thus refined to fit naturally in the palm of the hand, no matter the grip.Dedicated WiFi ensures continuous and efficient scanningThe CS 3800 uses dedicated point-to-point WiFi access that instantly receives data transferred from the handpiece to the computer. It’s as easy as plugging in a WiFi dongle. Once connected, it’s immediately ready to receive a signal from the handpiece: the pairing maintains a robust and stable transmission band for a continuous and efficient scanning procedure.Powered by CS ScanFlowCS ScanFlow software is the acquisition software paired with the CS 3800. Free yourself from imposed procedures: there is no need to choose a workflow when starting to scan – simply grab the handpiece and scan, then decide later which indication to apply to the data set. A four-step process keeps you on track from beginning to end. | Inmode Aesthetics Optimas with Lumecca 515 & 580LUMECCA
SR515
Spot size:10x30mm
Pulse Repetition:1pps at all energies
Wavelength:515-1200nm
Fluence:10-30J/cm2
Peak Power:High Peak Power
Pulse Duration:Short/Long
Cooling:Controlled
SR580
Technology:IPL
Spot size:10x30mm
Pulse Repetition:1pps at all energies
Wavelength:580-1200nm
Fluence:10-30J/cm2
Peak Power:High Peak Power
Pulse Duration:Short/Long
Cooling:Controlled
FORMA
RF Output Frequency: Up to 65 W
Output Frequency: 1 MHz
Temperature Cut-Off: Real time temperature measurements set by operator up to 43°C
FRACTORA
24 Pin:Type – Full Thickness Dermal; Configuration – 6×4; Pin Length – 3000u; Ablation Depth – 3 mm; Heating Depth – Between 3-5 mm; Max Output Energy 62 mj/pin; Output Frequency – 1 MHz; Repetition Rate – Up to 2 pps
24 Pin Coated:Type – Deep and Subdermal; Configuration – 6 x 4 Coated; Pin Length – 3000 u, Ablation Depth – 3 plus mm; Heating Depth – Between 3-5 mm; Max Output Energy 62 mj/pin; Output Frequency – 1 MHz; Repetition Rate – Up to 2 pps
60 Pin:Type – Mid Dermal; Configuration – 10×6; Pin Length – 600u; Ablation Depth – 0.6-1 mm; Heating Depth – Between 3-5mm; Max Output Energy 62 mj/pin; Output Frequency – 1 MHz; Repetition Rate – Up to 2 pps
DIOLAZEXL
Laser Wavelength:810 nm (diode)
Spot Size:12mm x 26 mm
Fluence:Up to 40 J/cm2
Pulse Duration:Short/Long
Light Cooling Guide:2-15°C
Repetition Rate:Single and Auto-Repeat
VASCULAZE
Laser Wavelength:1064 nm (diode)
Spot Size:3mm x 4mm
Fluence:40-300 J/cm2
Pulse Duration:5-100 msec
Light Cooling Guide:7-12° C
VLAZE
Laser Wavelength:1064 nm (yag)
Spot Size: 4 mm x 5 mm
Fluence: Up to 300 J/cm2
Pulse Duration: 5 ms 25 ms
MORPHEUS8
Type:Deep and Subdermal
Pin Length:4000
Ablation Depth:5mm +
Max Energy:62 mJ/pin at 75 W
Frequency:1 MHz
Repetition Rate:Up to 2 pps
A FULL BEAUTY SUITE
Optimas will help you optimize results for your patients and your businessProfessional grade aesthetic procedures – Optimas is a great suite of innovations in one workstation to help you achieve your goals. The Optimas full beauty suite has state-of-the-art light, laser, and radiofrequency devices for skin care and hair removal.Available Handpieces : Inmode Aesthetics Optimas with Lumecca 515 & 580
LUMECCA
FORMA
FRACTORA
DIOLAZEXL
VASCULAZE
VLAZE
MORPHEUS8LUMECCA
Fastest IPL Results*
*Clearance in 1-2 sessions, compared to 4-5 sessions with competing devicesLumecca is a breakthrough intense pulsed light (IPL) that delivers up to 3X more energy in the 500-600 nm range to improve efficacy for vascular and pigmented lesions. It is optimized for clinicians to treat a variety of skin types and conditions with just a single session.SR515 – Removal of Pigmented Lesions on Light Skin, Removal of Superficial Vascular Lesions
SR580 – Removal of Pigmented Lesions on DARK SkiN, Removal of DEEP Vascular Lesions, Removal of Vascular Lesions on DARK SkinFORMA
Face Remodeling.
Stimulates the formation of new collagen and improves the skin’s elasticity for long-lasting and remarkable resultsForma is the first auto-adjusting, non-invasive, thermal skin treatment for deep and uniform tissue stimulation. Forma uses radio-frequency power that flows uniformly between the electrodes to provide a comfortable thermal experience with immediate and subsequent contraction. There is no downtime in this effective lunch-time procedure that will make anyone look years younger!Acquire: Forma has a temperature sensor built into the hand piece which reads skin surface temperature 1000 times per second, allowing clinicians to acquire skin temperature in real time.
Control: Software algorithm allows unprecedented safety of RF delivery. The cut off temperature” feature reduces RF energy automatically when the hand piece senses that the required skin temperature has been reached.
Extend: Clinical evidence suggests prolonged exposure to temperature above 40°C is advantageous for optimal clinical outcomes. Only InMode’s A.C.E. technology allows you to utilize therapeutic temperatures safely and efficiently.FRACTORA Inmode Aesthetics Optimas with Lumecca 515 & 580
Radio Frequency MicroNeedling.
Fractora is a fractional skin resurfacing and subdermal tissue coagulation device that bridges the gap between fractional lasers and surgical procedures. Clinical papers demonstrate outcomes such as: improvement in skin complexion, reduction in skin irregularities and restoring skin to a more youthful appearance. This all occurs within one session or multiple sessions, depending on patient preference. Fractora can be used on active cystic acne and acne scars.Addresses multiple problems, including treatment of wrinkles with fractional coagulation and ablation.
Significant resolution of cystic acne and scars (improving acne scarring by 50%).
Safe on skin type VI with little risk of post inflammatory hyperpigmentation (PIH) which is common with other resurfacing methods.
Combination of fractional coagulation and volumetric heating through tips with various depths and pin density configurations.High efficiency of vascular and pigmented lesions due to high peak power and optimized output.
Complete photo rejuvenation in 1 or 2 treatments versus 4-6 treatments with standard IPLs.
Reduces treatment time thanks to large spot size and high pulse repetition rate.
Strong sapphire cooling tip results in painless procedure.
Fast pulse repetition rate at all settings. Highest peak power 3300W*DIOLAZEXL
Diode Hair Removal.
Gold Standard Diode Hair Removal Without Compromising Peak Power, Speed and Large Spot SizeDiolazeXL is the most effective at combining high peak power and a large spot size simultaneously in the same session. Clinicians can benefit from this first and only combination of speed, efficacy, safety and comfort to optimize their hair removal revenue.Gold standard wavelength, pulsing and power for optimal results and maximal safety.
Reduction in clinician treatment time – Powerful enough to target and treat even the most stubborn hair.
Virtually painless due to strong built in cooling.
Can treat up to skin type VI.VASCULAZE
Vascular Lesion Removal.
Get the ultimate in vascular resolution with a fast and chilled leg and facial vein treatmentVascular lesions (including angiomas, telangiectasias, port wine stains and leg veins) can be treated with the Vasculaze. The Vasculaze is optimized with high peak power that targets appropriate hemoglobin, so patients can benefit from a fast and safe treatment.Narrow and ergonomic spot size is optimized for vascular lesion treatment. High peak power. Strong contact cooling. No disposables and consumables.VLAZE
Vascular Lesion Removal.
Fast, powerful and ergonomic laser device. Treats vascular lesions such as veins, spider veins and port wine stains safely, comfortably and effectively on all skin types from very light to darker skin tones.MORPHEUS8
THE FIRST FULL BODY FRACTIONATED TECHNOLOGY
Fractional Remodeling and Contouring At Its BestThe Morpheus8 is a new subdermal adipose remodeling device (SARD) that fractionally remodels and contours the face and body. Penetrating deep into the skin and fat, this morphs the aging face of body into a more desired smooth and sleek appearance, for all skin tones.Deep and safe fractional treatment penetrating 4000 microns with an additional thermal profile of 1000+ microns
Extremely uniform effect
Little to no thermal damage to dermis
Safe on skin type VI with little risk of post inflammatory hyperpigmentation (PIH) which is common with other resurfacing methods. | Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HDAdvancing Smart OCTfor Anterior Segment, Glaucoma and Retina- Anterior Segment Premier Module
- PanoMap Wide-Field Display
- Smart HD Scans
- En face report
Visualization at the speed of CIRRUSAnalyzing a single pathology from multiple views provides comprehensive insight and analysis of the clinical situation. How this helps you: - Spot small areas of pathology. Tightly spaced B-scans, (either 30 or 47 μm apart), in the cube ensure that small areas of pathology are imaged. For reference, a human hair is about 40-120 μm in diameter.
- Visualize the fovea. Scans that are spaced further apart than in the CIRRUS cube may miss the central fovea.
- Fuel for analysis. Millions of data points from the cube are fed into the Zeiss proprietary algorithms for accurate segmentation, reproducible measurements and registration for change analysis.
- Take the pressure off the operator. As long as the scan is placed in the vicinity of the fovea or optic nerve, the software automatically centers the measurements after the capture.
- See the tissue from different perspectives. View the cube data from all angles, with 3D rendering, OCT fundus images and Advanced Visualization™.
- Future ready. Previously captured CIRRUS cubes can be analyzed using new analyses.
Tracking at the speed of CIRRUSFastTrac™ reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning
With FastTrac, scan at the highest resolution at the same location at each visit. Assessment at the speed of CIRRUSMeasurement centering with FoveaFinder and AutoCenterOn the macula, the unique FoveaFinder technology ensures the ETDRS and ganglion cell plus inner plexiform layer measurement frameworks are centered on the fovea.AutoCenter™ function automatically centers the 3.4 mm diameter peripapillary RNFL calculation circle around the disc for precise placement and repeatable registration. The placement of the circle is not operator dependent. Accuracy, registration and reproducibility are assured. Manage at the speed of CIRRUS Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HDGuided Progression Analysis (GPA™) for Assessing RNFL and Optic Disc ChangeGPA™ compares RNFL thickness and optic disc measurements over time and determines if statistically significant change has occurred.Focal Progression Analysis – Up to 6 progression maps are compared to two baselines. Areas of statistically significant change are color-coded yellow when first noted and then red when the change is sustained over consecutive visits.
Trend Analysis with Rate of Change – RNFL thickness values are plotted over time. Trends are calculated and confidence intervals are shaded when rate of change is statistically significant.
|
Reviews
There are no reviews yet.