| Description | 2015 Eclipse Aesthetics Skinfinity RF System, Serial Number SPA 20319, Includes: (1) RF Handpiece, (8) Everpulse Roller Tips, System Key, Trolley. | Candela GentleMAX ProEstablished in 1970, Candela is a leading US-based global medical aesthetic device company with headquarters in Wayland, Massachusetts. The company’s technologies enable physicians to provide advanced energy-based solutions for a broad range of medical-aesthetic applications including benign vascular and pigmented lesions, scars, hair removal, facial resurfacing, wrinkle reduction, women’s health treatments, tattoo removal, acne, leg veins, cellulite, and body shaping. | Bison Dual ACCENTO is the unique device combination with Alexandrite laser (755nm) and Nd:YAG laser (1064nm Long pulse)
The combination of two different wavelengths makes DUAL ACCENTO a highly effective system for hair removal and pigmented lesions treatment. The 755nm penetrates deep into the skin and perfectly targets hair the follicle and absorbs melanin. | New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort. | Energist NeoGen PSR offers a range of treatment options, and delivers the unparalleled results your patients expect: The unique energy delivered by NeoGen is non fractionated and not dependant on a chromophore for its uptake. This provides uniform energy absorption, ensuring consistent treatment of the skin, and at high energies supporting significant tightening. | ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER includes: Handpiece, Footswitch, Operator Eyewear, Patient Eyewear, Cart, Key, Operator Manual, ultrasound gel, replacement fuses, replacement filters |
| Content | Eclipse Aesthetics Skinfinity RF System
Skinfinity TechnologyThe Eclipse Skinfinity RF is innovation at its best. It is a fractional ablative radiofrequency technology designed for the improved appearance of fine lines and wrinkles, acne scars, skin revitalization and stretch marks. With the Skinfinity RF, treatments can be customized for the each patients specific needs due to the ability to control the ablative and thermal effect on the skin.SpeedSkinfinity RF uses patented In-Motion technology for fast treatments of the face and body. The state-of-the-art design of the roller tip enables delivery of focused RF through pyramid shaped electrodes arranged in rows of six. As Skinfinity RF effortlessly glides across the skin each electrode delivers precise energy creating controlled injuries to the tissue called Micro-ablative Treatment Zones (MTZs). This approach is significantly faster and much more predictable than stamping bi-polar RF ablative technologies.Power with SafetyThe Skinfinity RF treatments are similar to that of a Fractional CO2, however, unlike lasers, there is no target chromophore with Skinfinity RF. The utilization of fractional Unipolar RF makes the treatment applicable for most skin types. This allows the Skinfinity RF to be able to achieve gold-standard results with a much lower risk of complications compared to light-based ablative treatments.ConsistencyAs compared to fractional ablative bi-polar RF devices which create hot spots on the outer electrodes, Skinfinity RFs patented unipolar RF In-Motion treatment tip delivers consistent energy across the entire treatment area. The Skinifinity RF has adjustable energy output (up to 100W) and variable phase filter that allows the user to customize treatments for each patients individual skincare needs.Combination Therapy Eclipse Aesthetics Skinfinity RF SystemThe benefits of the pyramid-shaped electrodes and In-Motion roller tip are two-fold. First, the electrodes deliver precise energy to tissue so as to achieve the ideal Thermal Effect. Additionally, a secondary Mechanical Injury created by the In-Motion tip stimulates an enhanced healing response, thereby improving the results.Indications For Most Skin Types
Fine Lines
Skin Revitalization
Rhytids
Appearance of Stretch Marks (Striae)
Appearance of Acne Scars
Non-Keloidal Hypertrophic Scars
Appearance of Skin LaxityClinical Benefits
Applicable For Most Skin Types
Short Downtime
Minimally Ablative
Fast Treatment Times | 2017 Candela GentleMAX Pro Device DetailsThe Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24mm spot size, the largest spot found on any hair removal laser. Candela’spatented Dynamic Cooling Devise (DCD) technology protects the upper layers of skin with cooling bursts of cryogen. DCD cooling offers optimal treatment with minimal side effects.| Distributor | Candela |
|---|
| Manufacturer | Candela |
|---|
| Model | GentleMAX Pro |
|---|
| Manufactured Year | 2017 |
|---|
| Specific Equipment Type | Dual Wavelength Laser |
|---|
| Sale Price | 12500 |
|---|
| Treatments Performed | Hair Removal, Vascular, Pigmentation
Skin Rejuvenation
Skin Tightening |
|---|
| Handpieces | Standard Handpiece DCD 12-18mm , Large Spot Size Handpiece DCD 22-24mm |
|---|
| Shot Counts | None |
|---|
| Wavelengths | 755nm
1064nm |
|---|
| Consumables used by device | Windows, Distance Gauges |
|---|
| Consumables with purchase | 3 x Operator goggles, 1 x patient goggles, distance gauges, windows |
|---|
| Annual Service Price | Servicing available through Candela |
|---|
| Service Contract Price | $11,000 per annum |
|---|
| Additional Information | Any additional information can be sent on request |
|---|
| |
|---|
Treatments:2017 Candela GentleMAX Pro Device Details- Hair Removal
- Beard Bumps
- Facial Lesions
- Fine Lines and Wrinkles
- Leg Veins
- Skin Tightening
- Vascular Lesions
- Warts
- Skin Rejuvenation
- Hemangiomas
- Birthmarks
- Freckles
- Melasma
- Mevus of Ota
- Pigmented Lesions
- Sun / Age Spots
The Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24 mm spot size, the largest spot found on any hair removal laser.Fast – With 24 mm spot size and repetition rates up to 2 Hz, the The Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24 mm spot size, the largest spot found on any hair removal laser. It has two wavelengths, the 755 Alexandrite and the 1064 ND:yag, allowing you to offer many treatment options.Candela’s patented Dynamic Cooling Devise (DCD) technology protects the upper layers of skin with cooling bursts of cryogen. DCD cooling offers optimal treatment with minimal side effects. offers fast treatment times with it’s spot size.Powerful – 26,333 watts peak power, capable of delivering fluences up to 100 J/cm² for vascular applications, and hair removal energy in pulse duration as short as 3 ms for unparalleled treatment efficacies.Treats all skin types – Deep penetration with minimal scattering of laser energy makes the GentleMax Pro ideal for all skin types, particularly dark and tanned skin.Versatile – Non-ablative treatment, including fine lines and wrinkles, and for pseudofolliculitis barbae (PFB), or beard bumps, leg and facial veins.Patented Epidermal Cooling – Candela’s Dynamic Cooling Device represents an adjustable epidermal protection technology to maximize patient safety and comfort.Date of Manufacture – 2017Accessories Included with Purchase – Specialty 1.5, 3mm, 3x10mm Handpiece, 6, 8, 10, 12, 15, 18mm Handpiece, Full Set of Distance Gauges, Distance Gauge Case, Patient Eyewear, Treatment Goggles, Foot Pedal, Fiber Pole, System Key, System Interlock Key, Treatment Guidelines, and User Manual. | Bison Dual ACCENTO Nd YAG Laser
Bison Dual ACCENTOBison Dual ACCENTO is the unique device combination with Alexandrite laser (755nm) and Nd:YAG laser (1064nm Long pulse)
The combination of two different wavelengths makes DUAL ACCENTO a highly effective system for hair removal and pigmented lesions treatment. The 755nm penetrates deep into the skin and perfectly targets hair the follicle and absorbs melanin.The Dual Accento combined laser system is indicated for the following: 755 nm Long Pulsed Alexandrite Laser Temporary hair reduction. Stable long-term or permanent reduction through targeting of melanin in hair follicles. Treatment of bening pigmented lesions. Treatment of Wrinkles.The photocoagulation of dermatological vascular lesions (such as port of wine stains, hemangiomas, telangiectasis) 1064nm Long pulsed Nd:YAG laser. The removal of un-wanted hair reduction, for stable long term or permanent hair reduction and for treatment of PFB to all skin types Fitzpatrick I-VI including tanned skin.Pigmented lesions to reduce lesion size and patients with lesions. Reduction of red pigmentation in hypertrophic and keloid scars where vascularity is integral part of scar, treatment of wrinkle. Permanent hair reduction is defined as the long term, stable reduction in the number of hairs re- growing when measured at 6,9, and 12 months after the completion of treatment regime.The Dual Accento performs with high efficacy of the pigmentation problems without damaging tissue structures adjacent to the pigment. The wavelength of 1064nm Nd: YAG long pulse rejuvenates the skin by stimulating the collagen layer of the dermis and effectively treats vascular lesions and is appropriate for all skin types when used for hair removal.Bison Dual ACCENTO 1064nm NdYAG Laser With 755nm Alexandrite Laser
Bison Dual ACCENTO 1064nm NdYAG Laser with 755nm Alexandrite Laser is the unique device. Combining 755nm Long pulsed Alexandrite and 1064nm Long pulsed NdYAG Alexandrite 755nm long pulsed wavelength. Due to the high melanin absorption is effective for hair removal and pigmented lesions treatment. NdYAG 1064nm long pulsed wavelength rejuvenates skin by stimulating the dermis layer, effectively treating vascular lesions. | Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
The Laser uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IOptima-518-Classic Active Optical Systems Optima 518 IPL LaserThe Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. | Energist NeoGen PSR LaserNeoGen PSR SystemNeoGen nitrogen plasma technology delivers controlled heating to the skin architecture stimulating a significant physiological response, without creating an open wound. Unlike ablative technologies there is no epidermal vaporisation or charring caused at time of treatment.
Unique TechnologyNeoGen converts nitrogen gas into plasma energy, the fourth state of matter. The plasma emerges from the handpiece in controlled pulses and rapid heating of tissue occurs as it gives up its unique thermal energy to tissue.
No Open WoundsThe treated photodamaged layers undergo a controlled thermal modification, while remaining intact, creating a natural dressing to provide protection and speed healing. at high energies the epidermis sheds, but only after a new, healthier skin architecture is formed beneath.
Treats the Whole Skin ArchitectureTreating the entire skin structure ensures optimal results as the entire surface is regenerated with associated neocollagenesis and neoelastogenesis. No islands of untreated skin remain. Clinical studies show significant tightening – Mean 22% improvement in upper eyelid tightening (JOCD 7, 169-179, 2008).
Eyelids and Periorbital TreatmentEnergist NeoGen PSR is the ideal option for the treatment of the upper and lower eyelids, as well as the wider periorbital region. Other technologies cannot be used in this area or deliver inconsistent results.
Long Lasting ResultsClinical studies show neocollagenesis and reduction in elastosis continuing for more than one year post treatment.The Proven Power of Plasma for Skin Regeneration Energist NeoGen PSR Laser• Unique technology – controlled pulses of nitrogen plasma energy
• Treats the whole skin architecture – no islands of untreated skin remain
• Deep Tissue Remodelling – epidermis acts as natural dressing post treatment
• Versatile – high or low energy treatment choices to fit your patients’ needs and lifestyle
• Precise – treat eyelids effectively with significant results
• Long-lasting effects – intense fibroblast activity supports continued regeneration.
• Consistent – non-fractionated and non-chromophore dependence assures uniform energy absorption
• Proven Plasma Skin Regeneration is supported by numerous IRB-controlled studies
TechnologyPlasma skin regeneration was introduced with a level of scientific and clinical testing never before seen in the industry:
• 3+ years of pre-clinical and clinical testing
• 16 separate studies
• more than 450 clinical study treatments –No scarring or Hypopigmentation noted in studies
• one year clinical histology
This level of testing is very rare in the industryEnergist NeoGen PSR uses a highly energized gaseous state known as plasma to produce a unique thermal profile to penetrate the superficial and deeper levels of the dermis to replace damaged collagen and encourage new collagen growth for new skin. Plasma is produced inside the handpiece through the combination of inert nitrogen gas and ultra-high frequency RF.The Energist NeoGen PSR is emitted in millisecond pulses; the longer the pulse, the more energy is delivered. Nitrogen molecules impact the skin’s surface and immediately transfer energy upon contact. When the nitrogen plasma impacts the skin surface, energy is immediately transferred to the tissue. Oxygen is purged from the skin surface by the plasma, preventing carbonisation. The energy delivered to tissue ranges from 1 – 4 Joules and is user-adjustable. The repetition rate of the plasma pulses can also be controlled, and ranges from 1 – 2.5 Hertz.Specifications Energist NeoGen PSR| Power: | 100 – 120 / 230 Vrms – 50/60 Hz – 650 Va | | Energy Output: | Pulsed nitrogen plasma – 1-4 Joules. | | Repetition Rate: | 1.0 – 2.5Hz | | Dimensions: | 470 x 430 x 1060mm | | Gas Requirement: | Medical Grade Nitrogen | | System Weight: | 18kg/40lb | | Trolley Weight: | 25kg/55lb (excludes gas tank) | | Ambient Environment: | 0 to 40 celsius | | Relative Humidity: | 30 to 75% | | atmospheric pressure: | 700 to 1600 hpa |
| Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERr uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IActive Optical Systems Optima 518 IPL LaserOptima-518-Classic
The Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERNew Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. |
Reviews
There are no reviews yet.