| Description | Deka Synchro Replay Laser Nd-Yag Standard Handpieces – More than 10 selectable handpieces
– Different spotsizes available (2.5 – 24 mm)– Automatic spot recognition system– Ergonomic connector for air-cooling devices | Laser Hair Removal
Details:- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort. | Venus Concepts Venus Velocity Diode Laser Hair Removal – with largest spot size available on the market
INTEGRATED IOT TECHNOLOGY
Latest data collection technology to enhance business operations
Collects information to enhance business operations
Helps providers with optimizing business practices and improving treatment efficiency | IDS Daeshin Shiny Photo Skin Rejuvenation & Hair Removal. Includes: (2) Handpieces with 3 Different Wavelengths Each; Handpiece #1: 415-950nm, 560-950nm & 640-950nm; Handpiece #2: 640-1200nm, 695-1200nm, & 755-1200nm; Also Includes: (2) Handpiece Holders, Power Cable, Water Refill Kit, (2) Keys, Operator Manual, (2) Operator Eyewear, Patient Eyewear and 180 Day Warranty. | LOGIQ e Needle Recognition Software Option which helps provide precise and accurate display of the needle, anatomy and motion even in Color and Power Doppler. This feature harnesses pattern recognition technology that recognizes and accurately reveals the structure of a needle within the anatomy, without distortion of the needle and compromising the target. |
| Content | Deka Synchro Replay Laser Nd-Yag Inside Moveo Innovation Moveo HR: Focus on Hair Removal
The multiple passes of Moveo HR over small defined areas cause gradual heating and destruction of unwanted hairs.
Moveo PL: Focus on Pigmented Lesions
The new MOVEO PL is indicated for skin age and sun spots progressively heating the pigmentedMoveo SR: Focus on Skin Rejuvenation
The multipass controlled action of MOVEO SR causes a progressive increase in heat at the dermal level, which stimulates a neocollagenic process.Moveo VL: Focus on Vascular Lesions
The specific action of Moveo VL acts directly and effectively on vascular redness.The versatile FT lamp can be added to the system at any time, enhancing the user’s ability to treat superficial Vascular and Pigmented Lesions.The FT pulsed light has ten different filters divided in five spectra of emission (500-520-550-600-650nm) and two spot areas. This flexibility is useful to adapt the emitted light to the patient skin type, application and treatment area.Deka Synchro Replay Laser Nd-Yag Standard Handpieces – More than 10 selectable handpieces
– Different spotsizes available (2.5 – 24 mm)– Automatic spot recognition system– Ergonomic connector for air-cooling devicesDeka Synchro Replay Laser Nd-Yag
Wavelength: 1064 nm
Pulse Energy: 120 J (max)
Pulse Lenght: 0.2 ms to 300 ms
Frequency Single Pulse: 10Hz (max)
Spot Diameter: 20mm, 15mm, 10mm, 7mm, 5mm, 2.5mm
Emission Spectrum: 500-950 nm and 650-950 nmTo Include:
1 x Foot Switch
1 x Key
1 x Module UPL Handpiece
6 x Deka Laser Handpieces
1 x ManualInside Moveo InnovationMoveo HR: Focus on Hair Removal
The multiple passes of Moveo HR over small defined areas cause gradual heating and destruction of unwanted hairs.
Moveo PL: Focus on Pigmented Lesions
The new MOVEO PL is indicated for skin age and sun spots progressively heating the pigmented lesions.Moveo SR: Focus on Skin Rejuvenation
The multipass controlled action of MOVEO SR causes a progressive increase in heat at the dermal level, which stimulates a neocollagenic process.Moveo VL: Focus on Vascular Lesions
The specific action of Moveo VL acts directly and effectively on vascular redness. | 2019 Lumenis Splendor X- Laser Hair Removal
Lumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthThe Lumenis Splendor X has been introduced to be a player in the solid state Nd:YAG and Alexandrite laser hair removal market. The gold standard for hair removal has always been considered Alexandrite 755nm for light skins and Nd:YAG 1064nm for dark skins.The Lumenis Splendor X combines both in a unique way with blended emission.Instead of firing a single wavelength at a time the Splendor X allows you to fire both wavelengths simultaneous in adjustable amounts to suit the skin type and hair types. This means you are target multiple chromophores at any given time given enhanced results across the board.The Lumenis Splendor X also allows the user to choose between square and round spot sizes with large spot sizesLumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthLaser Hair Removal
Details:2019 Lumenis Splendor X- Laser Hair Removal- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
The Laser uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IOptima-518-Classic Active Optical Systems Optima 518 IPL LaserThe Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. | Venus Concepts Venus Velocity Laser Hair Removal System
Laser Type: Diode
Wavelength: 800nm
High Peak Power:Up to 2400 W
Fluence:Up to 100 J/cm2
Spot Sizes: Large 7cm2, Medium 3.5cm2, and Small 1.7cm2Experience the new gold standard in laser hair removal
Ultra-fast and comfortable treatmentsTECHNOLOGY Venus Concepts Venus Velocity Laser Hair Removal System
Venus Velocity, with the proven efficacy of diode laser technology, provides the optimal balance between high energy absorption of melanin chromophores and deep penetration into the skin, making it safe and effective for all skin types, including tanned skin.
POWERFUL & EFFICIENT SYSTEM FOR ALL SKIN TYPES
Optimal wavelength of 800 nm
High peak power of 2400 W
Fluence of up to 100 J/cm2ERGONOMIC APPLICATOR WITH THREE CHANGEABLE SPOT SIZES
Large at 7 cm2, medium at 3.5 cm2, and small at 1.7 cm2
Each tip fits seamlessly onto the one lightweight applicator, eliminating the need for multiple applicators or bulky, expensive replacement parts for spot size flexibility
Ergonomic applicator is designed for long hours of use with minimal risk of repetitive strain injury or operator fatigueVERSATILE WITH TWO MODES OF OPERATION
PULSE mode delivers higher energy to tissue at a lower repetition rate, which results in higher clinical efficacy and fewer treatment sessionsSLIDE mode, wherein the applicator is smoothly and continuously moved over the treatment area, delivers high repetition rate of short pulses, which achieves high average power with full coverage and greater patient comfort. In SLIDE mode, lower power and intensive cooling with heat accumulation enable efficient treatments.The unique ability to use either mode provides unparalleled versatility and enhances operator controlREVOLUTIONARY REAL-TIME COOLING SYSTEM
Monitors applicator temperature 1,000 times per second
Maintains temperature throughout the session to deliver a comfortable, safe treatment
No downtime for cooling translates to higher productivity for your clinicINTEGRATED IOT TECHNOLOGY
Latest data collection technology to enhance business operations
Collects information to enhance business operations
Helps providers with optimizing business practices and improving treatment efficiency | IDS Daeshin Shiny
IDS Daeshin Shiny is upgraded from the existing RPL model using our independent technology for innovative The better Photo rejuvenation & Hair removal treatment and more compact designSHINY represents the latest version of skin care equipment, which is built with the innovation technology of IDS Ltd. For safe and easy operation, the company has refined its technology and conducted clinical tests for many years.User instructionSHINY is suitable for treatment procedures for pigmented lesions, vascular lesions, acne and hair removal using basic wavelengths of 415nm, 560nm and 640nm. It can be also used for treatment of dark skin rejuvenation and hair removal by shifting to optional wavelengths of 640nm, 695nm and 755nm (ALEX Light). Wavelength can be selected very easily using a small rotator on the handpiece.Fast treatmentThe interval between each shot is shorter than that of the previous versions, and this makes the treatment easier and faster.Verified parametersBy smart protocols proper wavelength can be selected easily. The set parameters are optimized based on many clinical experiments to deliver maximal effects and safety.Advantages & Stronger points comparing to other devicesWhite toning (415nm)
Low depth of penetration (0.05~0.1mm) / High absorption (Melanin & Hemoglobin)
Safety (Fractional Concept IPL) / Excellent efficacy for faintly pigmented lesionsFractional type is our patent
Less side effects by heat (Fractional safety zone)Combine Rejuvenation (415nm 560nm) –> Amazing result in skin toning (Best in the world)Acne treatment
Fast hair removal (SHR)
ALEX (755nm) for hair removal (Best in the world)Technical FeaturesMaximal safety is achieved by Lattice technology based on fractional concepts. Lattice Optimal benefits of Lattice are provided by cutting edge technology.Traditional Spot SHINYRotating technology-based on IPL
SHINY allows easy choice of a wavelength range desired by using a rotator mounted in the hand piece. Selection of Wavelengths is easy without replacing the filter or the hand piece. (Patent No. 10-2004-0012778)Stable energy supplyA steady energy supply, which is achieved by technological expertise, allows safe operation of this beauty equipment and maximizes effects of treatment effects for each skin type.Cooling system can be controlledSemiconductor-based cooling system of SHINY can be controlled via the monitor, and maintains a steady temperature once it is set. This cooling system is aimed for minimizing pain of the patient and side effects.Light Source:Split (Intense) Pulsed Light (Xenon lamp)
Wavelength:415~950nm, 560~950nm, 640nm~950nm
Option: 640~1,200nm, 695~1,200nm
Fluence:5~40J/cmtwo
Spot Size:14.3 X 42.6mm
Pulse Sequence:Single , Double , Tripple Pulses, SHR mode
Pulse Duration:2.0 ~ 35.0ms
Pulse Delay:3.0 ~ 60.0ms
Repetition Rate:1Hz, 3Hz, 5Hz(Per Second)
Light Conduction:Quartz/ Sapphire Coupling
Cooling:Approximately up to 5℃, adjustable
Electrical Requirements:220V/16A, 50/60Hz
Physical Dimensions:360(D) X 520(L) X 1230(H)mm
Weight:60Kg2017 IDS Daeshin Shiny Photo Skin Rejuvenation & Hair Removal. Includes: (2) Handpieces with 3 Different Wavelengths Each; Handpiece #1: 415-950nm, 560-950nm & 640-950nm; Handpiece #2: 640-1200nm, 695-1200nm, & 755-1200nm; Also Includes: (2) Handpiece Holders, Power Cable, Water Refill Kit, (2) Keys, Operator Manual, (2) Operator Eyewear, Patient Eyewear and 180 Day Warranty. | GE Logiq E R7 Portable Ultrasound Machine
The NextGen LOGIQ combines the high performance of a console system with the portability of a laptop. GE Healthcare’s compact system is designed for general imaging, musculoskeletal, anesthesiology, interventional, emergency, and critical care applications.It provides ultrasound imaging with precise anatomical detail at a variety of depths. The system includes innovative features that help simplify interventional procedures.LOGIQ e Needle Recognition Software Option which helps provide precise and accurate display of the needle, anatomy and motion even in Color and Power Doppler. This feature harnesses pattern recognition technology that recognizes and accurately reveals the structure of a needle within the anatomy, without distortion of the needle and compromising the target.Also includes the ability to adjust needle gain and angle.- Standard package includes AC power cord (USA)
- internet cord 3 meter in length CAT-5 type
- PC to HUB structure
- system software on USB
- Optional Function Key Label
- Ultrasound Transmission Gel .25L
- English Basic Service Manual CD and English User Guide and AIUM booklet.
The following scanning modes are included:- B-mode
- M-mode
- Anatomical M-mode
- Color flow mode
- Power Doppler imaging
- Pulsed wave Doppler and Ophthalmic
Features:The NextGen LOGIQ ecombines the high performance of a console system with the portability of a laptop. GE Healthcare’s compact system is designed for general imaging, musculoskeletal, anesthesiology, interventional, emergency, and critical care applications.Display Screen:- 15 in High-Resolution Color LCD
- Resolution: 1024 x 768
- Horizontal/Vertical viewing angle: +/-80 degree
- Brightness AdjustmentIntegrated Speakers
- Audio Volume Adjustment
- Interactive Dynamic Software Menu
Console Design:- Laptop Style
- Lithium Ion Battery
- Integrated Solid State Drive
- CPU – Intel Duo Core
- Operating System – Microsoft® Windows® 7
Console Interfaces:- DC Power Input
- USB 2.0 (3)
- LAN 10/100/1000 BaseT
- Docking Cart Connector
- HDMI
Standard Features:- Integrated Solid State Drive
- Automatic Optimization
- CrossXBeamTM
- Speckle Reduction Imaging (SRI-HD)
- Virtual Convex/Virtual Apex
- Fine Angle Steer
- HD Zoom (Write Zoom)
- Coded Harmonic Imaging (CHI)
- Raw Data Processing
- Quicksave
- On-board User Manual (Help)
- InSiteTM ExC capability
- Loop storage—from live scanning and from memory
- Patient Information Database
- Customizable User Interface
- Full M&A Calculation Package with Real Time Auto Doppler Calculations
- Vascular Calcs
- Cardiac Calcs
- OB Calcs and Tables
- Fetal Trending
- Multi Gestational Calcs
- Musculoskeletal and Hip Dysplasia Calcs
- Gynecological Calcs
- Urological Calcs
- Renal Calcs
- Small Parts Calcs
- Rheumatology Calcs
- Pediatric Calcs
- Report Writer Package
Software Options:- easy3D
- LOGIQ View
- Needle Recognition
- Stress Echo
- eSmart Trainer
- Auto IMT
- DICOM® 3.0 Connectivity/Encrypted DICOM
Specifications: Console Dimensions Height- 70 mm (2.75 in) console only
- 100 mm (3.94 in) with handle
Width- 295 mm (11.61 in) console only
- 343 mm (13.50 in) with handle
Length- 346 mm (13.62 in) console only
- 375mm (14.76 in) with handle
Weight with Battery: Approximately 5.2 Kg (11.5 lbs)Operator Keyboard- Alphanumeric Keyboard
- Ergonomic Hard Keys
- Backlight Keys
Display Screen- 15 in High-Resolution Color LCD
- Resolution: 1024 x 768
- Horizontal/Vertical viewing angle: +/-80 degree
- Brightness Adjustment
- Integrated Speakers
- Audio Volume Adjustment
- Interactive Dynamic Software Menu
Console Electrical Power- Voltage: 100-240 V AC
- Frequency: 50/60 Hz
- Power: Max. 130 VA
Applications:GE Logiq E R7 Portable Ultrasound Machine- Abdomen
- Cardiac
- Gynecology
- Musculoskeletal
- Obstetrical
- Nerve Block
- Pediatric
- Small Parts
- Urological
- Vascular
- Rheumatology
- Emergency Medicine
- Cardiac intra-operative
|
Reviews