Carl Zeiss Cirrus HD-OCT 4000

$3,980.00

CIRRUS 4000 delivers high-speed image capture with HD imaging detail and a wider field of view so you can make more informed decisions and spend more time with the patients who need it.

Other people want this. 15 people have this in their carts right now.

Description

Carl Zeiss Cirrus HD-OCT 4000

The Cirrus HD-OCT is a non-contact, high resolution tomographic and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures, including cornea, retina, retinal nerve fiber layer, ganglion cell plus inner plexiform layer, macula, and optic nerve head. The Cirrus normative databases are quantitative tools for the comparison of retinal nerve fiber layer thickness, macular thickness, ganglion cell plus inner plexiform layer thickness, and optic nerve head measurements to a database of normal subjects. The Cirrus HD-OCT is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration, and glaucoma.

The ZEISS Certified Factory Direct Cirrus 4000 HD-OCT also includes the full Accessory Kit
External Fixation Light
Test Eye
Mini Keyboard
Optical Mouse
Dust Cover
Metric 5A/250v Fuse
14 Ft. CAT 5e Network Cable
USB Cable
IEC 320 to NEMA 12 inch Power Cable
IEC 320 39in. Power Cable
Install Disc including Roxio Basic
Symbol Sheet
OCT Primer Guide
Quick Start Guide

HD-OCT Imaging

Methodology: Spectral Domain OCT
Optical Source: superluminescent diode (SLD), 840 nm
Optical Power: < 725 μW at the cornea
Scan Speed: 27,000 A-scans per second
A-Scan depth: 2.0 mm (in tissue), 1024 points
Axial resolution: 5 μm (in tissue)
Transverse resolution: 15 μm (in tissue)

Zeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD Fundus Imaging

Methodology: Line scanning ophthalmoscope
Live Fundus Image: During alignment and during OCT scan
Optical Source: Superluminescent diode (SLD), 750 nm
Optical Power: < 1.5 mW at the cornea
Field of View: 36 degrees W x 30 degrees H
Frame rate: >20 Hz
Transverse resolution: 25 μm (in tissue)

Carl Zeiss Cirrus HD-OCT 4000 Iris Imaging

Methodology: CCD Camera
Resolution: 1280 x 1024
Live iris image: During alignment

Electrical, Physical and Environmental

Weight: 38kg (83 lbs)
Dimensions: 65L x 44W x 53H (cm)
Fixation: Internal, external
Internal fixation focus adjustment: -20D to +20D (diopters)
Input devices: Keyboard, mouse
Electrical rating (115V) Single Phase, 100/120V~ systems:50-60Hz, 5A
Fuse rating (115V) T 5A 250V
Electrical rating (230V) Single Phase, 220/240V~ systems:50-60 Hz, 2.5A
Fuse rating (230V) Fuse rating: T 5A 250V
Convenience Receptacle output ratings 115V~, 0.5 A Max, 50-60 Hz
Temperature (transport and storage) -40º to +70º C
Relative humidity (transport and storage) 10% to 100%, including condensation
Atmospheric pressure (transport and storage): 500 hPa to 1060 hPa
Temperature (operation) +10º to +35º C
Relative humidity (operation) 30% to 75%, excluding condensation
Atmospheric Pressure (operation) 700 hPa to 1060 hPa

Reviews

There are no reviews yet.

Be the first to review “Carl Zeiss Cirrus HD-OCT 4000”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsCarl Zeiss Cirrus HD-OCT 4000 removeEssilor Neksia Lens Edging System For Sale removeRodenstock Alino Multifunction Refractometer removeEssilor Mr Blue 2.0 Lens Edgers and Tracer For Sale removeTomey RC-5000 Auto Refractor Keratometer For Sale removeNidek RS-330 Retina Scan Duo 2 with FAF remove
NameCarl Zeiss Cirrus HD-OCT 4000 removeEssilor Neksia Lens Edging System For Sale removeRodenstock Alino Multifunction Refractometer removeEssilor Mr Blue 2.0 Lens Edgers and Tracer For Sale removeTomey RC-5000 Auto Refractor Keratometer For Sale removeNidek RS-330 Retina Scan Duo 2 with FAF remove
Image
SKU
Rating
Price $3,980.00 $4,240.00 $5,620.00 $3,600.00 $4,800.00 $3,150.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
CIRRUS 4000 delivers high-speed image capture with HD imaging detail and a wider field of view so you can make more informed decisions and spend more time with the patients who need it.
workflow, because some letters inspire confidence.With Neksia, Essilor combines years of experience in high-performance and precision edging into one of the most user-friendly and productive systems in the world.

Experience 6 analyses in 1 device: refraction, keratometry, topography, tonometry, pachymetry and dry eye analysis.

Mr Blue 2.0 is on the cutting edge of innovation – serving as a genuine ECP partner since its launch. Now featuring a whole range of new functions and even greater flexibility, Mr Blue is the perfect solution for demanding workshop.The Tomey RC-5000 has highly accurate measurement combined with short examination time and ease of use, makes working with the Tomey RC-5000 Autorefractor Keratometer both professional and quick. The advanced touch-screen display allows you to perform both refraction and keratometry automatically with one simple movement, capture one eye on the display and the Tomey RC-5000 will do both eyes automatically. With the new features, the Tomey RC-5000 Autorefractor Keratometer will surely make your office more efficient.
The Nidek RS-330 OCT is a combination of a High-Definition OCT and fundus camera. Optional delivery with FAF (Auto-fluorescence function)
Content

Carl Zeiss Cirrus HD-OCT 4000

The Cirrus HD-OCT is a non-contact, high resolution tomographic and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures, including cornea, retina, retinal nerve fiber layer, ganglion cell plus inner plexiform layer, macula, and optic nerve head. The Cirrus normative databases are quantitative tools for the comparison of retinal nerve fiber layer thickness, macular thickness, ganglion cell plus inner plexiform layer thickness, and optic nerve head measurements to a database of normal subjects. The Cirrus HD-OCT is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration, and glaucoma.The ZEISS Certified Factory Direct Cirrus 4000 HD-OCT also includes the full Accessory Kit External Fixation Light Test Eye Mini Keyboard Optical Mouse Dust Cover Metric 5A/250v Fuse 14 Ft. CAT 5e Network Cable USB Cable IEC 320 to NEMA 12 inch Power Cable IEC 320 39in. Power Cable Install Disc including Roxio Basic Symbol Sheet OCT Primer Guide Quick Start GuideHD-OCT ImagingMethodology: Spectral Domain OCT Optical Source: superluminescent diode (SLD), 840 nm Optical Power: < 725 μW at the cornea Scan Speed: 27,000 A-scans per second A-Scan depth: 2.0 mm (in tissue), 1024 points Axial resolution: 5 μm (in tissue) Transverse resolution: 15 μm (in tissue)Zeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD Fundus ImagingMethodology: Line scanning ophthalmoscope Live Fundus Image: During alignment and during OCT scan Optical Source: Superluminescent diode (SLD), 750 nm Optical Power: < 1.5 mW at the cornea Field of View: 36 degrees W x 30 degrees H Frame rate: >20 Hz Transverse resolution: 25 μm (in tissue)Carl Zeiss Cirrus HD-OCT 4000 Iris ImagingMethodology: CCD Camera Resolution: 1280 x 1024 Live iris image: During alignmentElectrical, Physical and EnvironmentalWeight: 38kg (83 lbs) Dimensions: 65L x 44W x 53H (cm) Fixation: Internal, external Internal fixation focus adjustment: -20D to +20D (diopters) Input devices: Keyboard, mouse Electrical rating (115V) Single Phase, 100/120V~ systems:50-60Hz, 5A Fuse rating (115V) T 5A 250V Electrical rating (230V) Single Phase, 220/240V~ systems:50-60 Hz, 2.5A Fuse rating (230V) Fuse rating: T 5A 250V Convenience Receptacle output ratings 115V~, 0.5 A Max, 50-60 Hz Temperature (transport and storage) -40º to +70º C Relative humidity (transport and storage) 10% to 100%, including condensation Atmospheric pressure (transport and storage): 500 hPa to 1060 hPa Temperature (operation) +10º to +35º C Relative humidity (operation) 30% to 75%, excluding condensation Atmospheric Pressure (operation) 700 hPa to 1060 hPa
Essilor Neksia Lens Edging SystemWork More Easily
  • A touch of efficiency – The 8.4-inch color touch-screen display makes navigation a breeze. And you can select the icon-based functions quickly and easily with just the touch of a finger.
  • Fast-access settings – With all job settings located conveniently on the centering part of the system, you can define your finishing settings quickly and launch edging jobs in just a few clicks. If necessary, you can still adjust settings after the feeler measurement.
  • A user-friendly 1,000-position job database – Save precious time by easily accessing or storing complete jobs in the database via the touch screen or optional barcode reader.
Experience Workflow Efficiency
  • Fast, easy and extended frame tracking – Equipped with auto frame-type selection, simple clamping and rapid tracing cycles, Neksia helps you trace any type of frame effortlessly, including children’s frames, small B-size and large A-size frames
  • Automatic drilling-hole recognition – Achieve even greater productivity thanks to optional features dedicated to automatic detection of drilling holes and flat bevel shapes.
  • Convenient centering and blocking – Neksia arms you with valuable features that make centering and blocking straight-forward and precise.
    • Handle lenses easily with the wide-open centering area
    • Increase precision with intelligent targeting and parallax-free working
    • Benefit from the intuitive on-screen interface
Achieve High Performance Essilor Neksia Lens Edging System
  • Improve axis accuracy – By combining new edging cycle algorithms and cutting-force regulation, you are guaranteed optimal results whatever the edging situation.
    • Optimized edging speed based on the lens material, shape and lens thickness guarantees fast cycle times, lens positioning and alignment.
    • The New Edging Assisted System cycle avoids axis deviation on new- generation hydrophobic lenses, rectangular shapes or fragile lenses.
  • Best automatic cycles – For 90% of your jobs, all it takes are a few clicks to achieve a perfectly calculated bevel, groove or drilling cycle. The lens is well positioned for an aesthetic and perfectly fitted result, no matter the material or frame type.
  • Consistent intelligent chamfering – With Neksia’s patented flexible chamfering wheel, the pressure applied to the wheel adapts seamlessly to the lens edge depending on the shape and curve of the lens.

Rodenstock Alino Multifunction Refractometer

Tune-up your businessExperience 6 analyses in 1 device: Rodenstock Alino Multifunction Refractometer Are you ready for something that is all-in-one, timesaving, space-saving and suits your business perfectly?Have a look at how powerful ALINO can be.6 in 1 solution01 RefractionHaving a good starting value for subjective refraction is essential. The QUICK REF MODE supports this even for uncooperative patients.02 KeratometryKAI (Kerato-asymmetry index) & KRI (Kerato-regularity index) give the first hint of possible irregularities on the cornea. This supports evaluation of the best vision correction or best-fitting contact lens.03 TonometryThe very gentle air puff created by a new generation of air-flow technology means that patients more readily accept the need for regular check-ups of the IOP measurement.04 PachymetryCorrecting the IOP by measuring the central corneal thickness is essential in interpreting the intraocular pressure.05 TopographyVarious topographic maps support you in carrying out vision screenings, contact lens fittings and in patient education.06 Dry EyeObserve the customers’ eye health and evaluate the long-term tolerability of contact lenses.Take advantage of the combination of tests:Additional servicesTonometry + PachymetryContact lens fitting andtolerance controlKeratometry + Topography + Dry EyeEye healthcareTopography + Tonometry + Pachymetry + Dry EyeSpecifications Rodenstock Alino Multifunction Refractometer REFRACTIVE POWER MEASUREMENTSpherical refractive power (S)            -30.00 D to + 25.00 D (at VD = 12.0 mm)Cylindrical power (C)                          0.00 D to ± 12.50 D (at VD = 12.0 mm)Astigmatic axis (A)                              0° to 180°KERATOMETRY MEASUREMENTCorneal curvature radius                    5.00 mm to 13.00 mmCorneal astigmatic axis                      0° to 180°INTRAOCULAR PRESSURE MEASUREMENTMeasurement range                           1 mmHg to 60 mmHG (1 hPa to 80 hPa)PACHYMETRY MEASUREMENTMeasurement range                           300 μm to 800 μmTOPOGRAPHY MEASUREMENTCorneal curvature radius                    5.50 mm to 10.00 mmCorneal astigmatic axis                      0° to 180°AUXILIARY FUNCTIONInterpupillary distance                         Measurement range: 20 mm to 85 mmCorneal diameter and pupil diameter Measurement range: 1.00 mm to 14.00 mmDry eye observation                            Blinking Analysis, Tear Meniscus height, Hyperemia, Meibomian glandsDATA MANAGEMENTInternal Database                               Integrated SD CardPrinter                                                 Integrated thermal printerData Output Type                               3x USB 2.0, 1x LAN, 1x SD Card-slot, 1x WLANExport Format                                     CSV, XML, JPG, PDFDIMENSIONS & ELECTRIC REQUIREMENTSDimensions WDH                               312 × 491 × 450 mmWeight                                                 Approx. 23 kgVoltage                                                100 VAC to 240 VACFrequency                                           50/60 HzPower consumption                            110 VA
Essilor Mr Blue 2.0 Lens Edgers and TracerComplete Control of Lens Mounting
  • Optimal monitoring of all trajectories, irrespective of finishing materials or shapes
  • Absolute axis control thanks to hybrid edging technology: grinding + milling
  • Ideally suited for quality finishing even on highest base curves
  • Fast and accurate drilling with data acquired in a single operation
  • Automatic centering and blocking for simple operation
Unrivalled Ergonomics
  • Completely integrated functions without external peripheral devices
  • Vertical architecture with <Heads-up displays> for optimum comfort
  • Storage features ensure all accessories are within reach.
  • Intelligent interface adapts to the way you work.
Highest Quality Guaranteed Essilor Mr Blue 2.0 Lens Edgers and TracerPerfect Centering
  • Binocular 3-D tracing of full-rim frames up to base 9*
  • Automatic adjustment of centering data based on the frames’ 30D parameters*
Aesthetic and Robust Mountings
  • FIT-4-Frame technology with dedicated small wheel*
  • Drilling and grooving tools can be tilted up to 30o, making it safe to mount lenses of up to base 10. *Essilor patents and exclusives
Safe Process
  • Roughing cycle automatically adapts to the curves of lenses up to base 10, avoiding all risk of breakage
  • Bevel placement and shelf depth optimized for safe mounting without undue stress of lens
Aesthetically Pleasing and Easy-to-Mount Bevels
  • The bevel heights are adjustable to perfectly adjust to the thinnest grooves
  • The shelf bevel heights are optimized to follow the frame’s shape perfectly
  • The step bevel is particularly suited for sport eyeglasses with deep, rectangular or uneven groove profile
Mr Blue 2.0 is on the cutting edge of innovation – serving as a genuine ECP partner since its launch. Now featuring a whole range of new functions and even greater flexibility, Mr Blue is the perfect solution for demanding workshop.

Tomey RC-5000 Auto Refractor Keratometer

Tomey RC-5000 RefractometryNormal Mode:-Fogging is applied automatically for each measurement for more Accurate ResultsQuick Mode:-Fogging is applied as needed for consecutive measurements.IOL/CAT Mode:-This mode is used to measure cataract or pseudophakic eyes.Keratometry:-Short consecutive measurements and time provide reliable data. -Measurements at 6.00mm (R=8.0mm) as well as at 3.00mm give you enough information for contact lens fitting. -base curves of contact lenses are stored, categorized and suggested manufacturers are automatically printed.Diameter Measurements of Cornea and Pupil:-Measurement can be done easily by moving the two cursors on the display to the boundary of cornea or pupil. This is useful for deciding the diameter of a contact lens and for other contact lens fitting practice.Power Joystick:-Move the joystick ring up/down and the instrument head moves up/down quickly. -Move the joystick hand rest to the right/left or backward/forward and the instrument head moves to the right/left or backward/forward quickly. -Rotate the joystick ring and the instrument head moves up/down slowly. -Tilt the joystick and the instrument head moves in each direction slowly.Power Chinrest:-The chin rest can be moved by pushing the buttons on the front panel. No need to reach out to the chin rest for manual adjustments.Autorefractor Keratometer Features:Refractometory : Tomey RC-5000 Auto Refractor Keratometer-Sphere 25.00 to +22.00D (VD =12.00mm) Cylinder -10.00 to +10.00D (VD = 12.00mm) -Axis 0 to 180 Degree -Minimum Pupil Dia. 2.2mm -Measurements Time 0.2 Sec.Keratometry :-Range 5.00mm to 11.00mm -Corneal Refraction 30.68D to 67.50D (n = 1.3375) -Corneal Astigmatism 0D to 10D (n = 1.3375) -Axis 0 to 180 Degree -Measured Area 3.0mm / 6.0 mm -Measured Time 0.1 Sec PD -Measurement Yes (50 to 86mm) -Diameter Measuremnt of Cornea & Pupil 1.0 to 14.0mm -Chinrest : Power Chin Rest -Printer : High Speed Thermal Line Printer -OutputPort RS-232C -Power Requirements: AC 100V to 240V -50/60Hz 130VA

Nidek RS-330 Retina Scan Duo 2 with FAF

The Retina Scan Duo 2 is a combined OCT and fundus camera system that incorporates new features enhancing screening and clinical efficiency in addition to user-friendly features that were incorporated from the previous model.FEATURES : Nidek RS-330 Retina Scan Duo 2 with FAF
  • Fundus image acquisition with macula and disc capture in one image on OCT
  • Combined diagnosis of macular and disc pathologies
  • Wide area scan (12 x 9 mm) Wide area normative database (macula: 9 x 9 mm, disc: 6 x 6 mm): A 12 x 9 mm wide area image can be acquired. The retina map captures both the macula and disc in a single shot. The normative database provides a wide area color-coded map comparing the patient’s macular thickness to a population of normal eyes.
  • Denoising technique with deep learning: A new image enhancement technique using deep learning automatically displays a denoised image once B-scan acquisition is complete. With deep learning of a large data set of images averaged from 120 images, this denoising technique provides high definition images comparable to a multiple-image-averaging technique. The denoising function generates high definition images from a single frame while decreasing image acquisition time and increasing patient comfort.
  • Quick acquisition of high definition B-scan images from a single-frame image
  • Fundus autofluorescence (FAF): The FAF function is an advanced screening feature that allows non-invasive evaluation of the RPE without contrast dye. *Available for the FAF model
Nidek RS-330 Retina Scan Duo 2– Easy operation with 3-D auto tracking, auto shot, and user friendly interface – High definition images – Wide area scan (12 x 9 mm) / Wide area normative database (9 x 9 mm) – Multiple OCT scan patterns – Value added features – Various reports
Nidek High speed image capture OCT images are captured at scan speeds of 70,000 A-scans/s which is 32% faster than acquisition with the Retina Scan Duo™ using Regular OCT sensitivity*Wide area scan (12 x 9 mm) Wide area normative database (macula: 9 x 9 mm, disc: 6 x 6 mm) A 12 x 9 mm wide area image can be acquired. The retina map captures both the macula and disc in a single shot. The normative database provides a wide area color-coded map comparing the patient’s macular thickness to a population of normal eyes.Denoising using deep learning A new image enhancement technique using deep learning automatically displays a denoised image once B-scan acquisition is complete. With deep learning of a large data set of images averaged from 120 images, this denoising technique provides high definition images comparable to a multiple-image-averaging technique. The denoising function generates high definition images from a single frame while decreasing image acquisition time and increasing patient comfort
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: Carl Zeiss Cirrus HD-OCT 4000 $3,980.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Shopping cart close