PERKASA MEDICAL

Free shipping worldwide. Orders over $200
Availability: In Stock

Bon Righton Retinomax K-Plus 3 Autorefractor Keratometer

$1,850.00

The series is Retinomax handheld refractor in the world and Ref / Keratometer, now enjoys greater mobility, stability and accuracy.

Other people want this. 15 people have this in their carts right now.

Description

Bon Righton Retinomax K-Plus 3 Autorefractor Keratometer

Automatic printing of both the Keratometry and Refraction data. – Simultaneous and automatic wireless transfer to a Remote Vision unit. – 0.35 second measuring time for each reading, plus you receive the most accurate data without having to press any keys. – Even when taking a Peripheral Keratometry reading, it completes a set of Refraction, Central Keratometry and Peripheral Keratometry readings in only 0.45 seconds per reading. – Quick Mode, Retro Function and Fixation Intensity Change all ensure accurate readings. – 100 patient memory. Simultaneous Measurement Measure Refraction and Keratometry data continuously and automatically in an amazing 0.35 seconds per reading. Peripheral Data The Tangential method measures four peripheral points in 25° direction concurrently

Lighter with a handle Thinner
Weighing less than one kilogram, the main body of the battery is over 17% lighter for the K-plus 3 and 11% lighter for Retinomax three conventional models Retinomax series.
Center of gravity of Retinomax Series 3 is in the grip, making the Series 3 feel much lighter and balanced.

NEW Auto Quick Measurement
If no measurement is performed within six seconds, the unit automatically enters Quick mode. The measurement is then performed, by 0.07 seconds. In Auto Quick mode, “AQ” appears on printouts.

New Student Auto measuring, displaying and printing
The unit measures pupil size automatically, displays the size of X (horizontal) on the monitor, and print sizes XY (horizontal and vertical) separately. The results can be used in the control housing, mydriasis, Adie and Horner-associated syndromes.

Retinomax K-PLUS 3 Additional Features
Refraction / keratometry readings fast
Peripheral corneal curvature readings
2.5mm Pupil Size and Intensity Setting selectable

Included:Bon Righton Retinomax K-Plus 3 Autorefractor Keratometer
Retinomax K-Plus 3 Main Body
Model eye
Charging Station
printer
battery
UL cord
neck strap
Roll paper

Reviews

There are no reviews yet.

Be the first to review “Bon Righton Retinomax K-Plus 3 Autorefractor Keratometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsBon Righton Retinomax K-Plus 3 Autorefractor Keratometer removeActive Optical Extra 818 IPL Skin Rejuvenation & Hair Removal removeActive Optical Systems Optima 518 IPL Laser removeAcuson Sequoia 512 LCD Ultrasound Machine removeInmode Aesthetics Optimas with Lumecca 515 & 580 For Sale removeBison Dual ACCENTO Nd YAG Laser For Sale remove
NameBon Righton Retinomax K-Plus 3 Autorefractor Keratometer removeActive Optical Extra 818 IPL Skin Rejuvenation & Hair Removal removeActive Optical Systems Optima 518 IPL Laser removeAcuson Sequoia 512 LCD Ultrasound Machine removeInmode Aesthetics Optimas with Lumecca 515 & 580 For Sale removeBison Dual ACCENTO Nd YAG Laser For Sale remove
Image
SKU
Rating
Price $1,850.00 $6,800.00 $5,200.00 $8,430.00 $12,840.00 $9,800.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

DescriptionThe series is Retinomax handheld refractor in the world and Ref / Keratometer, now enjoys greater mobility, stability and accuracy.The Extra – 818 is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features: * Contemporary touch screen control * Built-in Patch Test procedure for examining the optimal energy level * A stunning number of 450,000 flashes in both lamps. * The Large Handpiece has a Push Button in addition to the Foot Switch making work easier and faster for the therapist.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece: * Faster treatments – up to 0.5 Seconds Between pulses. * Real-time handpiece temperature control. * Contemporary and stylish design. * Light weight design – 25% less weight to improve the therapists’ comfort.The Sequoia system’s advanced technologies are designed to make image acquisition easier, reduce exam time and increase overall efficiency. Along with many other included features, the Sequoia system offers Native, a patient specific imaging which adapts both phase and amplitude information of each unique patient’s properties which delivers a consistently better image across a broad range of patients.Treatments offered with the InMode OptimasMorpheus8- Skin Resurfacing and RejuvenationLumecca IPL – Age spot and sun spot treatmentForma – Skin remodeling at its bestAvailable Handpieces: LUMECCA FORMA FRACTORA DIOLAZEXL VASCULAZE VLAZE MORPHEUS8LUMECCA Fastest IPL Results* *Clearance in 1-2 sessions, compared to 4-5 sessions with competing devicesBison Dual ACCENTO is the unique device combination with Alexandrite laser (755nm) and Nd:YAG laser (1064nm Long pulse) The combination of two different wavelengths makes DUAL ACCENTO a highly effective system for hair removal and pigmented lesions treatment. The 755nm penetrates deep into the skin and perfectly targets hair the follicle and absorbs melanin.
ContentBon Righton Retinomax K-Plus 3 Autorefractor KeratometerAutomatic printing of both the Keratometry and Refraction data. – Simultaneous and automatic wireless transfer to a Remote Vision unit. – 0.35 second measuring time for each reading, plus you receive the most accurate data without having to press any keys. – Even when taking a Peripheral Keratometry reading, it completes a set of Refraction, Central Keratometry and Peripheral Keratometry readings in only 0.45 seconds per reading. – Quick Mode, Retro Function and Fixation Intensity Change all ensure accurate readings. – 100 patient memory. Simultaneous Measurement Measure Refraction and Keratometry data continuously and automatically in an amazing 0.35 seconds per reading. Peripheral Data The Tangential method measures four peripheral points in 25° direction concurrentlyLighter with a handle Thinner Weighing less than one kilogram, the main body of the battery is over 17% lighter for the K-plus 3 and 11% lighter for Retinomax three conventional models Retinomax series. Center of gravity of Retinomax Series 3 is in the grip, making the Series 3 feel much lighter and balanced.NEW Auto Quick Measurement If no measurement is performed within six seconds, the unit automatically enters Quick mode. The measurement is then performed, by 0.07 seconds. In Auto Quick mode, “AQ” appears on printouts.New Student Auto measuring, displaying and printing The unit measures pupil size automatically, displays the size of X (horizontal) on the monitor, and print sizes XY (horizontal and vertical) separately. The results can be used in the control housing, mydriasis, Adie and Horner-associated syndromes.Retinomax K-PLUS 3 Additional Features Refraction / keratometry readings fast Peripheral corneal curvature readings 2.5mm Pupil Size and Intensity Setting selectableIncluded:Bon Righton Retinomax K-Plus 3 Autorefractor Keratometer Retinomax K-Plus 3 Main Body Model eye Charging Station printer battery UL cord neck strap Roll paperActive Optical Extra 818 IPL Skin Rejuvenation & Hair RemovalHandpieces:Integrated dual handpieces Chilled Tip:Up to 4c Pulse Interval:0.5-2 Seconds Output Power:11-31 joulse/cm2, upto 4,000W Cooling System:Revolutionary dual cooling Control:Intuitive touch screen control Lamp’s Life Span:250,000 Flashes (Universal) 200,000 Flashes (Facial) Treatment Area:4.5 cm2 (15*50mm) Universal, 4.5 cm2 (15*30mm) Facial Wavelength:420-100 nm Weight:42Kg (including Stand) Dimensions:44cm x 45cm x 100cmExtra-818 Active Optical Extra 818 IPL Skin Rejuvenation & Hair Removal The Extra – 818 is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features: * Contemporary touch screen control * Built-in Patch Test procedure for examining the optimal energy level * A stunning number of 450,000 flashes in both lamps. * The Large Handpiece has a Push Button in addition to the Foot Switch making work easier and faster for the therapist.The Extra – 818, based on Active’s GEM-PL technology, sets sets a specific Pulse Pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.The combination of tested treatment protocols with high end engineering makes the Extra – 818 the perfect device for leading clinics.Revolutionary Cooling System The Extra – 818 has a dual cooling system, controlled and monitored in order to ensure long lifetime to the lamp and a comfortable treatment to the patient.Competitive cooling systems “freeze” the skin so that during the treatment the skin temperature will rise to a bearable level. However, this “freezing” temperature might limit the results because the follicles will not reach the coagulation temperature. To ensure optimal results Active installed a special Processor that prevents overcooling the skin and maintains a uniform low temperature of the “glass” throughout the treatment. This revolutionary system enables the Extra – 818 to provide best results with optimal patient comfort.Research Program For clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31Jcm2 with high intensity of 4,000W.Active Optical Systems Optima 518 IPL Laser
Handpiece (Standard):Multipurpose Wavelength Mark-II Handpiece (Optional):Facial Treatments Pulse Interval/Repetition Rate:0.5 – 2 Seconds Maximum Output Treatment Pattern:22 Joule /cm 2 Output Power:11-31 Joule / cm 2 , up to 4000 W Cooling System:Improved Air Cooling Control:Advanced Software Interface Lamp’s Life Span:200,000 Flashes (minimum) Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2) Wavelength:420 – 1,100 nm Weight:88.18 lbs (40Kg) (including stand) Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm) Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz Max Mains Power:600 VA Treatments Variety: Skin Rejuvenation Pigmentation Treatment Acne Treatment Hair Removal Hair Removal – Deep Follicles Hair Removal – Sensitive Skin Vascular (Facial) Treatment Tattoo Removal The Laser uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated. 12 Programs 1 – Very Dark Skin, Fitzpatrick Skin Type IV 2 – Dark Skin, Fitzpatrick Skin Type IV 3 – Dark Skin, Fitzpatrick Skin Type III 4 – Dark Skin, Fitzpatrick Skin Type III 5 – Medium Skin, Fitzpatrick Skin Type II 6 – Medium Skin, Fitzpatrick Skin Type II 7 – Light Skin, Fitzpatrick Skin Type II 8 – Light Skin, Fitzpatrick Skin Type I 9 – Very Light Skin, Fitzpatrick Skin Type I 10 – Very Light Skin, Fitzpatrick Skin Type I 11 – Very Light Skin, Fitzpatrick Skin Type I 12 – High Power, Fitzpatrick Skin Type IOptima-518-Classic Active Optical Systems Optima 518 IPL LaserThe Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece: * Faster treatments – up to 0.5 Seconds Between pulses. * Real-time handpiece temperature control. * Contemporary and stylish design. * Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.Approvals * CE MDD Intl. Medical Standard * FDA U.S. Safety Standard * ISO-13485 Med. Production STD * IEC 60-601-1 Medical Safety STD * CFS Gov. Health Approval * CSA Can. & U.S. Safety App * TGA Australian health STD.
Siemens Acuson Sequoia 512 LCD Ultrasound Machine18″ Flat panel LCD Monitor–Progressive Media & Display II Package, Cardiac/OB/Vascular Calc. Package, Signature II Option, AUX, CPS Cardiology, CPS General Cadene Trigg Burst, Calc Data to MO, Card Cadence II Contrast Quant, Cornoary Flow reserve, Dicome Store/Print, DTI (Doppler Tissue Imaging), High HR ECG, MIS/MIF, Modality Worklist Native TEQ, Native TEQ, NTHI (Native Tissue Harmonics), Spectral TEQ, TEQ (Tissue Equalization), VVI

Features

  • Shared Service
  • Native Patient Specific Imaging
  • Four Sight TEE view
  • Axius quantitative strain rate imaging
  • Cadence contrast pulse sequencing technology
  • Native Tissue Harmonic Imaging
  • Native TEQ ultrasound technology
  • Color doppler, Color angio and b-color
  • PW/CW Doppler
  • M-Mode
  • Folding Flat Panel Display
  • DICOM capabilities

Applications

  • Abdominal
  • Breast
  • OB/GYN
  • Vascular
  • Pediatrics
  • Cardiology
  • Musculoskeletal
  • Neonatal

Acuson Sequoia 512 Features:

  • Imaging: Gray-scale 2-D, M-mode, SST Color Doppler, Solo Spectral Doppler, 3-D Surface Rendering, Native Tissue Harmonic Imaging, Auto Doppler, M-Mode, PW Doppler, Color Doppler, Color Power Doppler
  • 19" color CRT monitor
  • Native tissue harmonic imaging (NTHI)
  • DIMAQ: image management
  • Advanced vascular analysis
  • Advanced spatial compounding
  • Native patient specific imaging
  • Mitral valve assessment
  • CPS contrast pulse sequencing technology
  • Clarifying vascular enhancement technology
  • High resolution color flow
  • Vascular, and General Imaging calculation packages
  • Coherent beamformer technology/spatial compounding
  • Space/time resolution control
  • Cine and zoom/RES
Compatible Ultrasound Probes and Transducers:
  • Acuson V5Ms TEE Probe
  • Acuson 4C1 Curved Array Probe
  • Acuson 6C2 Curved Array Probe
  • Acuson 8C4 Curved Array Probe
  • Acuson 4V1 Vector Array Probe
  • Acuson EV-8C4 Endocavitary Probe
  • Acuson EC-10C5 Endocavitary Probe
  • Acuson 6L3 Linear Array Probe
  • Acuson 8L5T Intraoperative Probe
  • Acuson 8L5 Linear Array Probe
  • Acuson 9L4 Linear Array Probe
  • Acuson 15L8 Linear Array Probe
  • Acuson 17L5 Linear Array Probe
The Sequoia 512 with LCD ultrasound machine uniquely minimizes automatic image optimization time by up to 80% to make way for an easier and speedier ultrasound test time as well as allow for a more confident diagnosis each time. As a patient-specific imaging ultrasound, it has a unique matched response capacity for accurate image quality, sharp clinical specificity, and optimized diagnostic outcomes that makes infinitesimal pathologies and other anatomical detail in the most difficult-to-image patients becomes more vivid and visible. 
Inmode Aesthetics Optimas with Lumecca 515 & 580LUMECCA SR515 Spot size:10x30mm Pulse Repetition:1pps at all energies Wavelength:515-1200nm Fluence:10-30J/cm2 Peak Power:High Peak Power Pulse Duration:Short/Long Cooling:Controlled SR580 Technology:IPL Spot size:10x30mm Pulse Repetition:1pps at all energies Wavelength:580-1200nm Fluence:10-30J/cm2 Peak Power:High Peak Power Pulse Duration:Short/Long Cooling:Controlled FORMA RF Output Frequency: Up to 65 W Output Frequency: 1 MHz Temperature Cut-Off: Real time temperature measurements set by operator up to 43°C FRACTORA 24 Pin:Type – Full Thickness Dermal; Configuration – 6×4; Pin Length – 3000u; Ablation Depth – 3 mm; Heating Depth – Between 3-5 mm; Max Output Energy 62 mj/pin; Output Frequency – 1 MHz; Repetition Rate – Up to 2 pps 24 Pin Coated:Type – Deep and Subdermal; Configuration – 6 x 4 Coated; Pin Length – 3000 u, Ablation Depth – 3 plus mm; Heating Depth – Between 3-5 mm; Max Output Energy 62 mj/pin; Output Frequency – 1 MHz; Repetition Rate – Up to 2 pps 60 Pin:Type – Mid Dermal; Configuration – 10×6; Pin Length – 600u; Ablation Depth – 0.6-1 mm; Heating Depth – Between 3-5mm; Max Output Energy 62 mj/pin; Output Frequency – 1 MHz; Repetition Rate – Up to 2 pps DIOLAZEXL Laser Wavelength:810 nm (diode) Spot Size:12mm x 26 mm Fluence:Up to 40 J/cm2 Pulse Duration:Short/Long Light Cooling Guide:2-15°C Repetition Rate:Single and Auto-Repeat VASCULAZE Laser Wavelength:1064 nm (diode) Spot Size:3mm x 4mm Fluence:40-300 J/cm2 Pulse Duration:5-100 msec Light Cooling Guide:7-12° C VLAZE Laser Wavelength:1064 nm (yag) Spot Size: 4 mm x 5 mm Fluence: Up to 300 J/cm2 Pulse Duration: 5 ms – 25 ms MORPHEUS8 Type:Deep and Subdermal Pin Length:4000 Ablation Depth:5mm + Max Energy:62 mJ/pin at 75 W Frequency:1 MHz Repetition Rate:Up to 2 pps A FULL BEAUTY SUITE Optimas will help you optimize results for your patients and your businessProfessional grade aesthetic procedures – Optimas is a great suite of innovations in one workstation to help you achieve your goals. The Optimas full beauty suite has state-of-the-art light, laser, and radiofrequency devices for skin care and hair removal.Available Handpieces : Inmode Aesthetics Optimas with Lumecca 515 & 580 LUMECCA FORMA FRACTORA DIOLAZEXL VASCULAZE VLAZE MORPHEUS8LUMECCA Fastest IPL Results* *Clearance in 1-2 sessions, compared to 4-5 sessions with competing devicesLumecca is a breakthrough intense pulsed light (IPL) that delivers up to 3X more energy in the 500-600 nm range to improve efficacy for vascular and pigmented lesions. It is optimized for clinicians to treat a variety of skin types and conditions with just a single session.SR515 – Removal of Pigmented Lesions on Light Skin, Removal of Superficial Vascular Lesions SR580 – Removal of Pigmented Lesions on DARK SkiN, Removal of DEEP Vascular Lesions, Removal of Vascular Lesions on DARK SkinFORMA Face Remodeling. Stimulates the formation of new collagen and improves the skin’s elasticity for long-lasting and remarkable resultsForma is the first auto-adjusting, non-invasive, thermal skin treatment for deep and uniform tissue stimulation. Forma uses radio-frequency power that flows uniformly between the electrodes to provide a comfortable thermal experience with immediate and subsequent contraction. There is no downtime in this effective “lunch-time” procedure that will make anyone look years younger!Acquire: Forma has a temperature sensor built into the hand piece which reads skin surface temperature 1000 times per second, allowing clinicians to acquire skin temperature in real time. Control: Software algorithm allows unprecedented safety of RF delivery. The “cut off temperature” feature reduces RF energy automatically when the hand piece senses that the required skin temperature has been reached. Extend: Clinical evidence suggests prolonged exposure to temperature above 40°C is advantageous for optimal clinical outcomes. Only InMode’s A.C.E. technology allows you to utilize therapeutic temperatures safely and efficiently.FRACTORA Inmode Aesthetics Optimas with Lumecca 515 & 580 Radio Frequency MicroNeedling. Fractora is a fractional skin resurfacing and subdermal tissue coagulation device that bridges the gap between fractional lasers and surgical procedures. Clinical papers demonstrate outcomes such as: improvement in skin complexion, reduction in skin irregularities and restoring skin to a more youthful appearance. This all occurs within one session or multiple sessions, depending on patient preference. Fractora can be used on active cystic acne and acne scars.Addresses multiple problems, including treatment of wrinkles with fractional coagulation and ablation. Significant resolution of cystic acne and scars (improving acne scarring by 50%). Safe on skin type VI with little risk of post inflammatory hyperpigmentation (PIH) which is common with other resurfacing methods. Combination of fractional coagulation and volumetric heating through tips with various depths and pin density configurations.High efficiency of vascular and pigmented lesions due to high peak power and optimized output. Complete photo rejuvenation in 1 or 2 treatments versus 4-6 treatments with standard IPL’s. Reduces treatment time thanks to large spot size and high pulse repetition rate. Strong sapphire cooling tip results in painless procedure. Fast pulse repetition rate at all settings. Highest peak power 3300W*DIOLAZEXL Diode Hair Removal. Gold Standard Diode Hair Removal Without Compromising Peak Power, Speed and Large Spot SizeDiolazeXL is the most effective at combining high peak power and a large spot size simultaneously in the same session. Clinicians can benefit from this first and only combination of speed, efficacy, safety and comfort to optimize their hair removal revenue.Gold standard wavelength, pulsing and power for optimal results and maximal safety. Reduction in clinician treatment time – Powerful enough to target and treat even the most stubborn hair. Virtually painless due to strong built in cooling. Can treat up to skin type VI.VASCULAZE Vascular Lesion Removal. Get the ultimate in vascular resolution with a fast and chilled leg and facial vein treatmentVascular lesions (including angiomas, telangiectasias, port wine stains and leg veins) can be treated with the Vasculaze. The Vasculaze is optimized with high peak power that targets appropriate hemoglobin, so patients can benefit from a fast and safe treatment.Narrow and ergonomic spot size is optimized for vascular lesion treatment. High peak power. Strong contact cooling. No disposables and consumables.VLAZE Vascular Lesion Removal. Fast, powerful and ergonomic laser device. Treats vascular lesions such as veins, spider veins and port wine stains safely, comfortably and effectively on all skin types from very light to darker skin tones.MORPHEUS8 THE FIRST FULL BODY FRACTIONATED TECHNOLOGY Fractional Remodeling and Contouring At Its BestThe Morpheus8 is a new subdermal adipose remodeling device (SARD) that fractionally remodels and contours the face and body. Penetrating deep into the skin and fat, this morphs the aging face of body into a more desired smooth and sleek appearance, for all skin tones.Deep and safe fractional treatment penetrating 4000 microns with an additional thermal profile of 1000+ microns Extremely uniform effect Little to no thermal damage to dermis Safe on skin type VI with little risk of post inflammatory hyperpigmentation (PIH) which is common with other resurfacing methods.

Bison Dual ACCENTO Nd YAG Laser

Bison Dual ACCENTOBison Dual ACCENTO is the unique device combination with Alexandrite laser (755nm) and Nd:YAG laser (1064nm Long pulse) The combination of two different wavelengths makes DUAL ACCENTO a highly effective system for hair removal and pigmented lesions treatment. The 755nm penetrates deep into the skin and perfectly targets hair the follicle and absorbs melanin.The Dual Accento combined laser system is indicated for the following: 755 nm Long Pulsed Alexandrite Laser Temporary hair reduction. Stable long-term or permanent reduction through targeting of melanin in hair follicles. Treatment of bening pigmented lesions. Treatment of Wrinkles.The photocoagulation of dermatological vascular lesions (such as port of wine stains, hemangiomas, telangiectasis) 1064nm Long pulsed Nd:YAG laser. The removal of un-wanted hair reduction, for stable long term or permanent hair reduction and for treatment of PFB to all skin types Fitzpatrick I-VI including tanned skin.Pigmented lesions to reduce lesion size and patients with lesions. Reduction of red pigmentation in hypertrophic and keloid scars where vascularity is integral part of scar, treatment of wrinkle. Permanent hair reduction is defined as the long term, stable reduction in the number of hairs re- growing when measured at 6,9, and 12 months after the completion of treatment regime.The Dual Accento performs with high efficacy of the pigmentation problems without damaging tissue structures adjacent to the pigment. The wavelength of 1064nm Nd: YAG long pulse rejuvenates the skin by stimulating the collagen layer of the dermis and effectively treats vascular lesions and is appropriate for all skin types when used for hair removal.Bison Dual ACCENTO 1064nm NdYAG Laser With 755nm Alexandrite Laser Bison Dual ACCENTO 1064nm NdYAG Laser with 755nm Alexandrite Laser is the unique device. Combining 755nm Long pulsed Alexandrite and 1064nm Long pulsed NdYAG Alexandrite 755nm long pulsed wavelength. Due to the high melanin absorption is effective for hair removal and pigmented lesions treatment. NdYAG 1064nm long pulsed wavelength rejuvenates skin by stimulating the dermis layer, effectively treating vascular lesions.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: Bon Righton Retinomax K-Plus 3 Autorefractor Keratometer $1,850.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Shopping cart close