| Description | The series is Retinomax handheld refractor in the world and Ref / Keratometer, now enjoys greater mobility, stability and accuracy. | 3Deep Intensif Handpiece – Fractional Microneedling RF Skin Remodeling
Specifically designed to treat acne scars, deep wrinkles, stretch marks and other conditions requiring deep dermal heating. The Intensif Handpiece applies an array of micro-diameter needles to safely and effectively deliver focused RF energy deep into the dermis, providing a revolutionary collagen remodeling solution for acne scar treatment and deep wrinkle reduction, with minimal discomfort and downtime. | New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort. | CIRRUS HD-OCT 5000 is configured with the highest resolution visualization capabilities and sophisticated clinical applications such as Advanced RPE analysis to track retinal pigment epithelial integrity and Ganglion Cell Analysis to assess glaucomatous loss in the macula that may not be evident in the peripapillary region. The new FastTrac retinal tracking reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning. This feature enables the highest resolution B-Scans to be captured in identical locations from visit to visit providing precise assessment of change in targeted pathologies. | Treatments offered with the InMode OptimasMorpheus8- Skin Resurfacing and RejuvenationLumecca IPL – Age spot and sun spot treatmentForma – Skin remodeling at its bestAvailable Handpieces:
LUMECCA
FORMA
FRACTORA
DIOLAZEXL
VASCULAZE
VLAZE
MORPHEUS8LUMECCA
Fastest IPL Results*
*Clearance in 1-2 sessions, compared to 4-5 sessions with competing devices | Deka Synchro Replay Laser Nd-Yag Standard Handpieces – More than 10 selectable handpieces
– Different spotsizes available (2.5 – 24 mm)– Automatic spot recognition system– Ergonomic connector for air-cooling devices |
| Content | Bon Righton Retinomax K-Plus 3 Autorefractor KeratometerAutomatic printing of both the Keratometry and Refraction data. – Simultaneous and automatic wireless transfer to a Remote Vision unit. – 0.35 second measuring time for each reading, plus you receive the most accurate data without having to press any keys. – Even when taking a Peripheral Keratometry reading, it completes a set of Refraction, Central Keratometry and Peripheral Keratometry readings in only 0.45 seconds per reading. – Quick Mode, Retro Function and Fixation Intensity Change all ensure accurate readings. – 100 patient memory. Simultaneous Measurement Measure Refraction and Keratometry data continuously and automatically in an amazing 0.35 seconds per reading. Peripheral Data The Tangential method measures four peripheral points in 25° direction concurrentlyLighter with a handle Thinner
Weighing less than one kilogram, the main body of the battery is over 17% lighter for the K-plus 3 and 11% lighter for Retinomax three conventional models Retinomax series.
Center of gravity of Retinomax Series 3 is in the grip, making the Series 3 feel much lighter and balanced.NEW Auto Quick Measurement
If no measurement is performed within six seconds, the unit automatically enters Quick mode. The measurement is then performed, by 0.07 seconds. In Auto Quick mode, “AQ” appears on printouts.New Student Auto measuring, displaying and printing
The unit measures pupil size automatically, displays the size of X (horizontal) on the monitor, and print sizes XY (horizontal and vertical) separately. The results can be used in the control housing, mydriasis, Adie and Horner-associated syndromes.Retinomax K-PLUS 3 Additional Features
Refraction / keratometry readings fast
Peripheral corneal curvature readings
2.5mm Pupil Size and Intensity Setting selectableIncluded:Bon Righton Retinomax K-Plus 3 Autorefractor Keratometer
Retinomax K-Plus 3 Main Body
Model eye
Charging Station
printer
battery
UL cord
neck strap
Roll paper | Endymed Pro Hair Laser3Deep iFine Handpiece – Eye & Mouth Area Skin Tightening Handpiece
Specifically designed to treat the hard to reach, delicate skin tissue around the eyes and mouth.
The revolutionary iFine handpiece provides:.
Smoother, tighter skin around the eyes
Reduced under eye sagging and improved eye contour
Reduced hooding to reveal more of the eyelid
More youthful, less tired looking eyes
Reduction in the fine lines around the mouthEndymed Pro Hair Laser 3Deep Intensif Handpiece – Fractional Microneedling RF Skin Remodeling
Specifically designed to treat acne scars, deep wrinkles, stretch marks and other conditions requiring deep dermal heating. The Intensif Handpiece applies an array of micro-diameter needles to safely and effectively deliver focused RF energy deep into the dermis, providing a revolutionary collagen remodeling solution for acne scar treatment and deep wrinkle reduction, with minimal discomfort and downtime.Endymed Pro Hair Laser 3DEEP Large Handpiece – Body Contouring & Skin Tightening Handpiece
Specifically designed for treatment of larger body areas, such as the abdomen, buttocks and thighs, for treating skin laxity, cellulite, body shaping and circumference reduction.3Deep Shaper Handpiece – Body Contouring & Skin Tightening Handpiece
Specifically designed for treatment of larger body areas, such as the abdomen, buttocks and thighs, for treating skin laxity, cellulite, body shaping and circumference reduction – larger coverage than the Large Handpiece.3DEEP Small – Body Tightening Handpiece
Specially designed for the treatment of wrinkles and lax skin on the face and neck, including forehead, temples, cheeks and under chin areas.3DEEP Fine – Facial Tightening Handpiece
Specially designed for skin laxity treatment of smaller body areas, such as peri-umbilical, neck, arms and knees.Fractional Skin Resurfacing Handpiece
The Fractional Skin Resurfacing (FSR) handpiece was developed by experts in dermatology, RF technology and ergonomics. Specially designed for fractional skin resurfacing and the treatment of skin roughness, hyperpigmentation, wrinkles and scars on both facial and body areas.3DEEP has 7 peer reviews and 86.7% efficasy
Results in 18 min WITH NO SWELLING on a 10×10 cm area.Ultimate in versatility, offering a multitude of treatment options in one radio frequency device. Utilizing proprietary 3DEEP™ technology, the EndyMed PRO provides deep dermal heating and collagen remodeling.PATIENT BENEFITS
• Highly effective
• Customized treatment parameters
• Optimal safety with minimal discomfort and no side effects
• Short treatment with minimal downtime
• Noticeable immediate improvement
• Long term resultsPHYSICIAN BENEFITS
• Effective solutions for anti-wrinkles, skin tightening, fractional skin resurfacing and body contouring
• Fast, walk-in / walk-out procedure for optimal patient satisfaction
• Customized treatment plan with preset default parameters
• Suitable for the complete range of skin types
• Single platform growth plan
• No consumables (for the 3Deep handpieces) and low priced consumables (for the FSR handpiece) for rapid ROI and profitability | Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
The Laser uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IOptima-518-Classic Active Optical Systems Optima 518 IPL LaserThe Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. | Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HDAdvancing Smart OCTfor Anterior Segment, Glaucoma and Retina- Anterior Segment Premier Module
- PanoMap Wide-Field Display
- Smart HD Scans
- En face report
Visualization at the speed of CIRRUSAnalyzing a single pathology from multiple views provides comprehensive insight and analysis of the clinical situation. How this helps you: - Spot small areas of pathology. Tightly spaced B-scans, (either 30 or 47 μm apart), in the cube ensure that small areas of pathology are imaged. For reference, a human hair is about 40-120 μm in diameter.
- Visualize the fovea. Scans that are spaced further apart than in the CIRRUS cube may miss the central fovea.
- Fuel for analysis. Millions of data points from the cube are fed into the Zeiss proprietary algorithms for accurate segmentation, reproducible measurements and registration for change analysis.
- Take the pressure off the operator. As long as the scan is placed in the vicinity of the fovea or optic nerve, the software automatically centers the measurements after the capture.
- See the tissue from different perspectives. View the cube data from all angles, with 3D rendering, OCT fundus images and Advanced Visualization™.
- Future ready. Previously captured CIRRUS cubes can be analyzed using new analyses.
Tracking at the speed of CIRRUSFastTrac™ reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning
With FastTrac, scan at the highest resolution at the same location at each visit. Assessment at the speed of CIRRUSMeasurement centering with FoveaFinder and AutoCenterOn the macula, the unique FoveaFinder technology ensures the ETDRS and ganglion cell plus inner plexiform layer measurement frameworks are centered on the fovea.AutoCenter™ function automatically centers the 3.4 mm diameter peripapillary RNFL calculation circle around the disc for precise placement and repeatable registration. The placement of the circle is not operator dependent. Accuracy, registration and reproducibility are assured. Manage at the speed of CIRRUS Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HDGuided Progression Analysis (GPA™) for Assessing RNFL and Optic Disc ChangeGPA™ compares RNFL thickness and optic disc measurements over time and determines if statistically significant change has occurred.Focal Progression Analysis – Up to 6 progression maps are compared to two baselines. Areas of statistically significant change are color-coded yellow when first noted and then red when the change is sustained over consecutive visits.
Trend Analysis with Rate of Change – RNFL thickness values are plotted over time. Trends are calculated and confidence intervals are shaded when rate of change is statistically significant.
| Inmode Aesthetics Optimas with Lumecca 515 & 580LUMECCA
SR515
Spot size:10x30mm
Pulse Repetition:1pps at all energies
Wavelength:515-1200nm
Fluence:10-30J/cm2
Peak Power:High Peak Power
Pulse Duration:Short/Long
Cooling:Controlled
SR580
Technology:IPL
Spot size:10x30mm
Pulse Repetition:1pps at all energies
Wavelength:580-1200nm
Fluence:10-30J/cm2
Peak Power:High Peak Power
Pulse Duration:Short/Long
Cooling:Controlled
FORMA
RF Output Frequency: Up to 65 W
Output Frequency: 1 MHz
Temperature Cut-Off: Real time temperature measurements set by operator up to 43°C
FRACTORA
24 Pin:Type – Full Thickness Dermal; Configuration – 6×4; Pin Length – 3000u; Ablation Depth – 3 mm; Heating Depth – Between 3-5 mm; Max Output Energy 62 mj/pin; Output Frequency – 1 MHz; Repetition Rate – Up to 2 pps
24 Pin Coated:Type – Deep and Subdermal; Configuration – 6 x 4 Coated; Pin Length – 3000 u, Ablation Depth – 3 plus mm; Heating Depth – Between 3-5 mm; Max Output Energy 62 mj/pin; Output Frequency – 1 MHz; Repetition Rate – Up to 2 pps
60 Pin:Type – Mid Dermal; Configuration – 10×6; Pin Length – 600u; Ablation Depth – 0.6-1 mm; Heating Depth – Between 3-5mm; Max Output Energy 62 mj/pin; Output Frequency – 1 MHz; Repetition Rate – Up to 2 pps
DIOLAZEXL
Laser Wavelength:810 nm (diode)
Spot Size:12mm x 26 mm
Fluence:Up to 40 J/cm2
Pulse Duration:Short/Long
Light Cooling Guide:2-15°C
Repetition Rate:Single and Auto-Repeat
VASCULAZE
Laser Wavelength:1064 nm (diode)
Spot Size:3mm x 4mm
Fluence:40-300 J/cm2
Pulse Duration:5-100 msec
Light Cooling Guide:7-12° C
VLAZE
Laser Wavelength:1064 nm (yag)
Spot Size: 4 mm x 5 mm
Fluence: Up to 300 J/cm2
Pulse Duration: 5 ms 25 ms
MORPHEUS8
Type:Deep and Subdermal
Pin Length:4000
Ablation Depth:5mm +
Max Energy:62 mJ/pin at 75 W
Frequency:1 MHz
Repetition Rate:Up to 2 pps
A FULL BEAUTY SUITE
Optimas will help you optimize results for your patients and your businessProfessional grade aesthetic procedures – Optimas is a great suite of innovations in one workstation to help you achieve your goals. The Optimas full beauty suite has state-of-the-art light, laser, and radiofrequency devices for skin care and hair removal.Available Handpieces : Inmode Aesthetics Optimas with Lumecca 515 & 580
LUMECCA
FORMA
FRACTORA
DIOLAZEXL
VASCULAZE
VLAZE
MORPHEUS8LUMECCA
Fastest IPL Results*
*Clearance in 1-2 sessions, compared to 4-5 sessions with competing devicesLumecca is a breakthrough intense pulsed light (IPL) that delivers up to 3X more energy in the 500-600 nm range to improve efficacy for vascular and pigmented lesions. It is optimized for clinicians to treat a variety of skin types and conditions with just a single session.SR515 – Removal of Pigmented Lesions on Light Skin, Removal of Superficial Vascular Lesions
SR580 – Removal of Pigmented Lesions on DARK SkiN, Removal of DEEP Vascular Lesions, Removal of Vascular Lesions on DARK SkinFORMA
Face Remodeling.
Stimulates the formation of new collagen and improves the skin’s elasticity for long-lasting and remarkable resultsForma is the first auto-adjusting, non-invasive, thermal skin treatment for deep and uniform tissue stimulation. Forma uses radio-frequency power that flows uniformly between the electrodes to provide a comfortable thermal experience with immediate and subsequent contraction. There is no downtime in this effective lunch-time procedure that will make anyone look years younger!Acquire: Forma has a temperature sensor built into the hand piece which reads skin surface temperature 1000 times per second, allowing clinicians to acquire skin temperature in real time.
Control: Software algorithm allows unprecedented safety of RF delivery. The cut off temperature” feature reduces RF energy automatically when the hand piece senses that the required skin temperature has been reached.
Extend: Clinical evidence suggests prolonged exposure to temperature above 40°C is advantageous for optimal clinical outcomes. Only InMode’s A.C.E. technology allows you to utilize therapeutic temperatures safely and efficiently.FRACTORA Inmode Aesthetics Optimas with Lumecca 515 & 580
Radio Frequency MicroNeedling.
Fractora is a fractional skin resurfacing and subdermal tissue coagulation device that bridges the gap between fractional lasers and surgical procedures. Clinical papers demonstrate outcomes such as: improvement in skin complexion, reduction in skin irregularities and restoring skin to a more youthful appearance. This all occurs within one session or multiple sessions, depending on patient preference. Fractora can be used on active cystic acne and acne scars.Addresses multiple problems, including treatment of wrinkles with fractional coagulation and ablation.
Significant resolution of cystic acne and scars (improving acne scarring by 50%).
Safe on skin type VI with little risk of post inflammatory hyperpigmentation (PIH) which is common with other resurfacing methods.
Combination of fractional coagulation and volumetric heating through tips with various depths and pin density configurations.High efficiency of vascular and pigmented lesions due to high peak power and optimized output.
Complete photo rejuvenation in 1 or 2 treatments versus 4-6 treatments with standard IPLs.
Reduces treatment time thanks to large spot size and high pulse repetition rate.
Strong sapphire cooling tip results in painless procedure.
Fast pulse repetition rate at all settings. Highest peak power 3300W*DIOLAZEXL
Diode Hair Removal.
Gold Standard Diode Hair Removal Without Compromising Peak Power, Speed and Large Spot SizeDiolazeXL is the most effective at combining high peak power and a large spot size simultaneously in the same session. Clinicians can benefit from this first and only combination of speed, efficacy, safety and comfort to optimize their hair removal revenue.Gold standard wavelength, pulsing and power for optimal results and maximal safety.
Reduction in clinician treatment time – Powerful enough to target and treat even the most stubborn hair.
Virtually painless due to strong built in cooling.
Can treat up to skin type VI.VASCULAZE
Vascular Lesion Removal.
Get the ultimate in vascular resolution with a fast and chilled leg and facial vein treatmentVascular lesions (including angiomas, telangiectasias, port wine stains and leg veins) can be treated with the Vasculaze. The Vasculaze is optimized with high peak power that targets appropriate hemoglobin, so patients can benefit from a fast and safe treatment.Narrow and ergonomic spot size is optimized for vascular lesion treatment. High peak power. Strong contact cooling. No disposables and consumables.VLAZE
Vascular Lesion Removal.
Fast, powerful and ergonomic laser device. Treats vascular lesions such as veins, spider veins and port wine stains safely, comfortably and effectively on all skin types from very light to darker skin tones.MORPHEUS8
THE FIRST FULL BODY FRACTIONATED TECHNOLOGY
Fractional Remodeling and Contouring At Its BestThe Morpheus8 is a new subdermal adipose remodeling device (SARD) that fractionally remodels and contours the face and body. Penetrating deep into the skin and fat, this morphs the aging face of body into a more desired smooth and sleek appearance, for all skin tones.Deep and safe fractional treatment penetrating 4000 microns with an additional thermal profile of 1000+ microns
Extremely uniform effect
Little to no thermal damage to dermis
Safe on skin type VI with little risk of post inflammatory hyperpigmentation (PIH) which is common with other resurfacing methods. | Deka Synchro Replay Laser Nd-Yag Inside Moveo Innovation Moveo HR: Focus on Hair Removal
The multiple passes of Moveo HR over small defined areas cause gradual heating and destruction of unwanted hairs.
Moveo PL: Focus on Pigmented Lesions
The new MOVEO PL is indicated for skin age and sun spots progressively heating the pigmentedMoveo SR: Focus on Skin Rejuvenation
The multipass controlled action of MOVEO SR causes a progressive increase in heat at the dermal level, which stimulates a neocollagenic process.Moveo VL: Focus on Vascular Lesions
The specific action of Moveo VL acts directly and effectively on vascular redness.The versatile FT lamp can be added to the system at any time, enhancing the user’s ability to treat superficial Vascular and Pigmented Lesions.The FT pulsed light has ten different filters divided in five spectra of emission (500-520-550-600-650nm) and two spot areas. This flexibility is useful to adapt the emitted light to the patient skin type, application and treatment area.Deka Synchro Replay Laser Nd-Yag Standard Handpieces – More than 10 selectable handpieces
– Different spotsizes available (2.5 – 24 mm)– Automatic spot recognition system– Ergonomic connector for air-cooling devicesDeka Synchro Replay Laser Nd-Yag
Wavelength: 1064 nm
Pulse Energy: 120 J (max)
Pulse Lenght: 0.2 ms to 300 ms
Frequency Single Pulse: 10Hz (max)
Spot Diameter: 20mm, 15mm, 10mm, 7mm, 5mm, 2.5mm
Emission Spectrum: 500-950 nm and 650-950 nmTo Include:
1 x Foot Switch
1 x Key
1 x Module UPL Handpiece
6 x Deka Laser Handpieces
1 x ManualInside Moveo InnovationMoveo HR: Focus on Hair Removal
The multiple passes of Moveo HR over small defined areas cause gradual heating and destruction of unwanted hairs.
Moveo PL: Focus on Pigmented Lesions
The new MOVEO PL is indicated for skin age and sun spots progressively heating the pigmented lesions.Moveo SR: Focus on Skin Rejuvenation
The multipass controlled action of MOVEO SR causes a progressive increase in heat at the dermal level, which stimulates a neocollagenic process.Moveo VL: Focus on Vascular Lesions
The specific action of Moveo VL acts directly and effectively on vascular redness. |
Reviews