PERKASA MEDICAL

Free shipping worldwide. Orders over $200
Availability: In Stock

Avante Integra SP VSO2 Portable Anesthesia Machine

$7,500.00

Features

  • Small and compact unit ideal for office-based anesthesia
  • Lightweight machine weighs only 26 pounds!
  • Three gas machine (O2, N2O and Air)
  • Mechanical anti-hypoxic device and air/N2O interlock
  • Retractable top handle for easy transport
  • Conveniently located side gas ports
  • Many ventilator options available.
  • Selectatec-compatible vaporizer mounting system
  • Optional carrying case with retractable handle and casters
  • Optional mobile trolley with shelf
  • Holds 1 vaporizer
  • Specifically designed to accommodate low flow
  • Auxiliary O2 flowmeter port
  • Recessed flush valve
  • Also available with MRI-compatible Penlon Nuffield Ventilator
Other people want this. 15 people have this in their carts right now.

Description

Avante Integra SP VSO2 Portable Anesthesia Machine

The Avante Integra SP VSO2 is a fully-functional, compact and portable anesthesia system in a lightweight package. The Integra SP VSO2 anesthesia system is compact enough for the smallest surgery or imaging suite, and is fully portable.

Easily transport the Avante Integra SP VSO2 by using the retractable handle, located conveniently on top of the unit. Side-located gas ports allow clinicians to safely and efficiently set up the machine.

In keeping with Avante’s commitment to quality, all Integra SP anesthesia systems include a two-year manufacturer’s warranty. The Avante Integra SP VSO2 is available with a hardshell carrying case, complete with casters and a retractable handle. A convenient mobile trolley with a sturdy built-in shelf is also available.

Features

  • Small and compact unit ideal for office-based anesthesia
  • Lightweight machine weighs only 26 pounds!
  • Three gas machine (O2, N2O and Air)
  • Mechanical anti-hypoxic device and air/N2O interlock
  • Retractable top handle for easy transport
  • Conveniently located side gas ports
  • Many ventilator options available.
  • Selectatec-compatible vaporizer mounting system
  • Optional carrying case with retractable handle and casters
  • Optional mobile trolley with shelf
  • Holds 1 vaporizer
  • Specifically designed to accommodate low flow
  • Auxiliary O2 flowmeter port
  • Recessed flush valve
  • Also available with MRI-compatible Penlon Nuffield Ventilator

Physical Weight & Dimensions

  • Height: 13.8 inches (35 cm)
  • Width: 19.7 inches (50 cm)
  • Depth: 7.9 inches (20 cm)
  • Weight (without vaporizer): 26 lbs (12 kg)

Flowmeters

  • Flow Range: Oxygen / Air: 0 – 10 L/min
  • Flowmeter Accuracy:  ± 2.5% full scale reading
  • Flowmeter construction and dimensions: Tubes and floats are matched, and must not be interchanged. Flowmeter tubes have antistatic coatings

Oxygen Failure Warning Devices

  • Gas system whistle
  • Visual indicator, direct pressure operated

Oxygen Flush

  • Button on front edge worksurface
  • The system supplies 35 – 75 L/min when the button is fully depressed

Mechanical AHD System

  • Minimum oxygen concentration: 30% ± 3% ( total O2 + N2O flow)
  • Basal flow – oxygen: 100 – 200 mL/min

Environmental

  • Operating Temperature: + 10 to 38°C (50 to 100°F)
  • Operating Atmospheric Pressure Range: 70 to 106 kPa
  • Operating Altitude: 2438 m (8000 ft) maximum
  • Operating Humidity: 10 – 85% R.H. non-condensing
  • Transport / Storage Temperature: -5 to 40°C (23 to 104°F)
  • Cleaning: Wipe external surfaces with dry or damp cloth. Use mild soap, or disinfectant solution if necessary.

Reviews

There are no reviews yet.

Be the first to review “Avante Integra SP VSO2 Portable Anesthesia Machine”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsAvante Integra SP VSO2 Portable Anesthesia Machine remove2019 Lumenis Splendor X- Laser Hair Removal For Sale remove2019 Cartessa SkinWave Skin Treatment System remove2018 Vivace RF Microneedling Radio Frequency Acne Scars removeCutting Edge MLS M6 Laser Therapy Unit For Sale removeENDYMED PURE PLUS FOR SALE remove
NameAvante Integra SP VSO2 Portable Anesthesia Machine remove2019 Lumenis Splendor X- Laser Hair Removal For Sale remove2019 Cartessa SkinWave Skin Treatment System remove2018 Vivace RF Microneedling Radio Frequency Acne Scars removeCutting Edge MLS M6 Laser Therapy Unit For Sale removeENDYMED PURE PLUS FOR SALE remove
Image
SKU
Rating
Price $7,500.00 $25,000.00 $8,900.00 $16,740.00 $12,830.00 $3,850.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description

Features

  • Small and compact unit ideal for office-based anesthesia
  • Lightweight machine weighs only 26 pounds!
  • Three gas machine (O2, N2O and Air)
  • Mechanical anti-hypoxic device and air/N2O interlock
  • Retractable top handle for easy transport
  • Conveniently located side gas ports
  • Many ventilator options available.
  • Selectatec-compatible vaporizer mounting system
  • Optional carrying case with retractable handle and casters
  • Optional mobile trolley with shelf
  • Holds 1 vaporizer
  • Specifically designed to accommodate low flow
  • Auxiliary O2 flowmeter port
  • Recessed flush valve
  • Also available with MRI-compatible Penlon Nuffield Ventilator
Laser Hair Removal
Details:
  • Serial Number: SQEAY-19M-XXXXX (message for serial number)
  • System Total Shot Count: 560,693
  • Alex Shot Count: 221,437
  • YAG Shot Count: 339,256

Includes:

  • Handpiece and Delivery System
  • Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
  • Fiber Pole
  • Foot Switch
  • System Key
  • Operators Manual
  • 30 Day Parts and Labor Warranty
2019 Cartessa SkinWave Skin Treatment System; Includes: Cart, (1) Exfoliating/Infusing Handpiece, (1) LED Light Handpiece, (1) Lymphatic Massage Handpiece, (3) Packs of Small 10 Set Aqua Scaling Tips, (1) AquaClean Solution S1 Skin-Peeling & Hydration, (1) AquaClean Solution S2 Skin-Peeling & Hydration, (1) AquaClean Solution S3 Skin-Nourishment & Hydration,The Cartessa SkinWave Skin Treatment System combines an aqua-delivery system, skin revitalizing solutions and Hydrogen therapy for a multi-dimensional skincare treatment. Solutions rich in Alpha Hydroxy Acid (AHA), Beta Hydroxy Acid (BHA), Hyaluronic Acid and Hydrogen (H2) are infused deep into the skin, while gentle extraction removes impurities.Let’s Face It! We want to look our best at any age—not over-filled and over-stretched, just natural. We want to age gracefully, beautifully and elegantly. Inevitably, fine lines and wrinkles set in, and now there is a simple, minimally-invasive treatment that will address those concerns and have you out to dinner that same night.The M6 therapy laser is a robotized multi-target device designed to treat patients suffering pathologies affecting a wide area, and to perform automatic applications. The distinctive feature of the M6 is the innovative multi-target functioning. Thanks to the features of the exclusive MLS multi-diodic optical group, a wide area is treated instantaneously helping to produce an immediate response of the treated tissues. The results are better and faster than with the scanning modality of traditional laser therapy products.The PURE+ is offered in two configurations:FSR + TC: Fixed FSR handpiece + one exchangeable connector suitable for all TC handpieces: iFine, Small and Large TC Complete: Two exchangeable connectors on each side, suitable for all TC handpieces: iFine, Shaper, Small and LargeThe iFine treatment Handpiece – specially engineered to target fine lines and wrinkles found in the delicate thin – skin areas around the eyes, providing: Smoother, tighter skin around the eyes. Reduced under eye sagging and improved eye contour. Reduced hooding to reveal more of the eyelid. More youthful, less tired looking eyes. Softening of fine line enabling easier application of make-up.
ContentAvante Integra SP VSO2 Portable Anesthesia MachineThe Avante Integra SP VSO2 is a fully-functional, compact and portable anesthesia system in a lightweight package. The Integra SP VSO2 anesthesia system is compact enough for the smallest surgery or imaging suite, and is fully portable.Easily transport the Avante Integra SP VSO2 by using the retractable handle, located conveniently on top of the unit. Side-located gas ports allow clinicians to safely and efficiently set up the machine.In keeping with Avante's commitment to quality, all Integra SP anesthesia systems include a two-year manufacturer's warranty. The Avante Integra SP VSO2 is available with a hardshell carrying case, complete with casters and a retractable handle. A convenient mobile trolley with a sturdy built-in shelf is also available.Features
  • Small and compact unit ideal for office-based anesthesia
  • Lightweight machine weighs only 26 pounds!
  • Three gas machine (O2, N2O and Air)
  • Mechanical anti-hypoxic device and air/N2O interlock
  • Retractable top handle for easy transport
  • Conveniently located side gas ports
  • Many ventilator options available.
  • Selectatec-compatible vaporizer mounting system
  • Optional carrying case with retractable handle and casters
  • Optional mobile trolley with shelf
  • Holds 1 vaporizer
  • Specifically designed to accommodate low flow
  • Auxiliary O2 flowmeter port
  • Recessed flush valve
  • Also available with MRI-compatible Penlon Nuffield Ventilator

Physical Weight & Dimensions

  • Height: 13.8 inches (35 cm)
  • Width: 19.7 inches (50 cm)
  • Depth: 7.9 inches (20 cm)
  • Weight (without vaporizer): 26 lbs (12 kg)

Flowmeters

  • Flow Range: Oxygen / Air: 0 - 10 L/min
  • Flowmeter Accuracy:  ± 2.5% full scale reading
  • Flowmeter construction and dimensions: Tubes and floats are matched, and must not be interchanged. Flowmeter tubes have antistatic coatings

Oxygen Failure Warning Devices

  • Gas system whistle
  • Visual indicator, direct pressure operated

Oxygen Flush

  • Button on front edge worksurface
  • The system supplies 35 - 75 L/min when the button is fully depressed

Mechanical AHD System

  • Minimum oxygen concentration: 30% ± 3% ( total O2 + N2O flow)
  • Basal flow - oxygen: 100 - 200 mL/min

Environmental

  • Operating Temperature: + 10 to 38°C (50 to 100°F)
  • Operating Atmospheric Pressure Range: 70 to 106 kPa
  • Operating Altitude: 2438 m (8000 ft) maximum
  • Operating Humidity: 10 - 85% R.H. non-condensing
  • Transport / Storage Temperature: -5 to 40°C (23 to 104°F)
  • Cleaning: Wipe external surfaces with dry or damp cloth. Use mild soap, or disinfectant solution if necessary.

2019 Lumenis Splendor X- Laser Hair Removal

Lumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones. The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthThe Lumenis Splendor X has been introduced to be a player in the solid state Nd:YAG and Alexandrite laser hair removal market. The gold standard for hair removal has always been considered Alexandrite 755nm for light skins and Nd:YAG 1064nm for dark skins.The Lumenis Splendor X combines both in a unique way with blended emission.Instead of firing a single wavelength at a time the Splendor X allows you to fire both wavelengths simultaneous in adjustable amounts to suit the skin type and hair types. This means you are target multiple chromophores at any given time given enhanced results across the board.The Lumenis Splendor X also allows the user to choose between square and round spot sizes with large spot sizesLumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones. The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelength
Laser Hair Removal
Details:2019 Lumenis Splendor X- Laser Hair Removal
  • Serial Number: SQEAY-19M-XXXXX (message for serial number)
  • System Total Shot Count: 560,693
  • Alex Shot Count: 221,437
  • YAG Shot Count: 339,256
Includes:
  • Handpiece and Delivery System
  • Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
  • Fiber Pole
  • Foot Switch
  • System Key
  • Operators Manual
  • 30 Day Parts and Labor Warranty

2019 Cartessa SkinWave Skin Treatment System

The Skinwave combines an aqua-delivery system, skin revitalizing solutions and Hydrogen therapy for a multi-dimensional skincare treatment. Solutions rich in Alpha Hydroxy Acid (AHA), Beta Hydroxy Acid (BHA), Hyaluronic Acid and Hydrogen (H2) are infused deep into the skin, while gentle extraction removes impurities. Its the ultimate compliment to brighten skin, improve vitality and tone.Cartessa Aesthetics teamed up with Eunsung Global manufacturer to exclusively bring Skinwave to the US. Eunsung Global is a South Koreabased, global leader focused on innovation in medical aesthetic equipment, present in over 70 countries and 100 partners worldwide.Hydrogen Therapy Clean 2019 Cartessa SkinWave Skin Treatment System Skinwaves aqua-delivery system starts with a Hydrogen-enriched water infusion. The high concentration of Hydrogen reacts with active Oxygen that is linked to drying and aging. By forming newly-bound water molecules that are extracted via the radial tips, this unique Skinwave step provides antioxidant and moisturization benefits and reduces inflammation.Target Skin Concerns Three nutrient-rich solutions optimize skin revitalization. Skinwave infuses deep into the skin Alpha Hydroxy Acid (AHA), Beta Hydroxy Acid (BHA) and Hyaluronic Acid to address top skincare needs: exfoliating, oil control and moisturization. Dial-up the volume of one of these solutions to offer a more customizable treatment.Multi-Dimensional Experience Two additional handpieces round out this multi-dimensional aesthetic treatment. Electrical pulse hand-piece open pores to maximize solution absorption with red and blue LED light for targeted treatments. Double-lifting handpiece activates lymphatic circulation, provides muscle relaxation, skin tightening and lifting effects.Cartessa SkinWave Treatment SystemThe Cartessa SkinWave Skin Treatment System combines an aqua-delivery system, skin revitalizing solutions and Hydrogen therapy for a multi-dimensional skincare treatment. Solutions rich in Alpha Hydroxy Acid (AHA), Beta Hydroxy Acid (BHA), Hyaluronic Acid and Hydrogen (H2) are infused deep into the skin, while gentle extraction removes impurities. Its the ultimate compliment to brighten skin, improve vitality and tone. Cartessa Aesthetics teamed up with Eunsung Global manufacturer to exclusively bring Skinwave to the US. Eunsung Global is a South Koreabased, global leader focused on innovation in medical aesthetic equipment, present in over 70 countries and 100 partners worldwide.

2018 Vivace RF Microneedling Radio Frequency Acne ScarsTHE VIVACE EXPERIENCE The most exciting new technology for aesthetic treatments is the combination of two methods previously used individually for skin rejuvenation, Microneedling and RF Energy. FDA-cleared for your safety, the newest generation, best-in-class Vivace RF Microneedling device, is designed for an incomparable, comfortable experience. Only Vivace boasts a precision robotic motor that brings discomfort to a virtual zero compared to any other device. The results are immediate and improve over time as well, giving you the best of both worlds. Our carefully developed recovery system ensures no one knows you just had a treatment. If you are looking for optimal results, there is no comparison to The Vivace Experience.What is Vivace Fractional RF Microneedling? The Vivace RF Laser Radio Frequency is the newest generation of microneedling with radio frequency and is effective for fine lines and wrinkles, skin tightening, acne, acne scars, and skin tone, texture and pore size, both on and off the face. It is the most revolutionary contouring and skin tightening system for face, neck, hands and body available, producing immediate, pain-free results.Safe for all skin types, Vivace can offer similar results as ablative and fractional laser procedures, but with significantly less discomfort, downtime, and risk of complications. This revolutionary new treatment also addresses the limitations of older ‘traditional’ RF treatments and heats deeper tissues to a much higher level, which leads to greater collagen production, elastin remodeling and wound contraction previously unattainable with older technology. This is why the Vivace is a game changer in skin rejuvenation and tightening. CLICK HERE to learn moreSlate combines the best device with the newest breakthroughs in numbing, treatment serums and recovery care to create an optimal experience for you that might just keep you from needing other more invasive procedures down the road. The Vivace Experience provides the most dramatic results with less pain and less downtime. The results are both immediate and improve over time with multiple treatments. With results you can see, you’ll look and feel your best at any age.Slate Medspa is the premier Fractional RF Microneedling provider in NJ. We use the most advanced technology to provide a results-oriented skin rejuvenation program. New to Slate Medspa? Call us today at 201-477-5781 to schedule a free consultation and save 20% off your first treatment.How does Vivace Fractional RF Microneedling work? The Vivace utilizes radio frequency and microneedling to heat the targeted area underneath the epidermis. The Vivace dramatically improves the treatment outcomes compared to other radio frequency microneedling systems.By using insulated needles, Vivace bypasses the epidermis and delivers powerful RF thermal energy to create tens of thousands of fractional coagulation zones in the dermis, facilitating a natural wound healing process. This promotes production of new collagen, remodeling of elastin and wound contraction, enhancing skin laxity. Because the thermal energy is delivered beneath the top layer of skin,Benefits of VIVACE:2018 Vivace RF Microneedling Radio Frequency Acne Scars Minimizes/Eliminates Fine Lines and Wrinkles Minimizes/Eliminates Acne Scars & Stretch Marks Skin Tightening & Texture – Stimulates collagen and elastin production Treat Sun Damage/Age Spots/Hyperpigmentation 8 Reasons why Slate LOVES Vivace™ RF Microneedling You’ll see results quickly Vivace works faster than any other microneedling or laser option. First, the RF Energy creates micro injuries deep in the skin in the form of a matrix. Healthy cells around the newly created matrix promote rapid healing, accelerating collagen production and skin tightening. Secondly, the invisible microchannels in the skin created by the superfine gold-tipped needles remain open for four to six hours allowing maximum absorption the key nutrients and serums applied during the treatment. This would include growth factors, HAs and other cosmeceuticals delivered to the skin in a way that no other treatment can, helping to rapidly rebuild new collagen and elastin.The average patient gets optimal results in just three treatments Most patients experience noticeably softer, smoother and radiant skin, with improvements in tone, texture and laxity after just one treatment. We can typically achieve optimal results after only three sessions!The treatment is virtually painless The Vivace Microneedle RF was designed for an incomparable, comfortable patient experience. The unique robotic motor is so precise, it brings the discomfort level to a virtual zero as compared to any other device. The Vivace’s ultra thin needles make it virtually pain-free. A numbing cream is applied before treatment for you to stay comfortable. Our patients here at Slate Medspa consistently report a pain level of “1” on a scale of 1 to 10.There’s no downtime Vivace’s ultra-thin needles and robotic-assisted mechanism result in an exceptionally precise, even treatment with little-to-no bleeding. In addition, built-in LED Light therapy minimizes post-treatment redness. While we ask patients to wait until the next day before applying makeup, most feel comfortable going out without any makeup.It’s safe for almost any skin type Patients with darker skin tones can have a more challenging time finding suitable skin resurfacing treatments, as lasers and peels that remove skin layers can risk permanent pigmentation changes. Vivace has 31 Adjustable depths, providing flexibility in treating entire depth or just down deep, bypassing damage to the top layer of skin. This means we can treat a broader array of skin types and tones with absolute precision. In addition, a variable pulse duration means the length of time the needle is engaged with tissue can be precisely controlled based on your skin profile.

Cutting Edge MLS M6 Laser Therapy Unit

The M6 therapy laser is a robotized multi-target device designed to treat patients suffering pathologies affecting a wide area, and to perform automatic applications. The distinctive feature of the M6 is the innovative multi-target functioning. Thanks to the features of the exclusive MLS multi-diodic optical group, a wide area is treated instantaneously helping to produce an immediate response of the treated tissues. The results are better and faster than with the scanning modality of traditional laser therapy products.Technical Features Robotized optical group with 3 MLS sources – power up to 3.3 W 5 cm diameter target area highlighted by high-efficiency red light LEDs Back-lit graphic touch-screen display Simultaneous management of two independent channels MLS pulse modulation frequency from 1 to 2000 Hz with 1 Hz steps Power level 50% and 100% Variable or fixed duty cycle Treatment duration from 1″ to 99’59” with 1″ steps Automatic calculation of the emitted energy according to the set parameters Alarms and Safety Features Laser emission warning light Interlock (can be temporarily disabled) Acoustic signal for the beginning and the end of the therapy, and for each treatment second (can be disabled) Password to operate the device Language option (Italian, English, German, Spanish) Dimensions and Weight 27 x 17 x 62 inches; 95 lbsPower Supply 115/230V~ 50/60Hz 150VACUTTING EDGE MLS M6 Laser Therapy UnitTalk to your specialist. Since 1983 we have been working to be the reference point in Laser Therapy and Magnetotherapy in many areas: from physiotherapy to rehabilitation, from the management of muscle and joint pain to sports medicine. The result of our work allows us today to be recognized as an international leader in the knowledge and development of advanced technologies in the field of “pain management”: a recognition confirmed in 2003 with the entry of the El.En Group. (Star segment of the Italian Stock Exchange – ELN.MI), one of the most important realities in the laser world, both for industrial and medical applications.We have always thought that research is not only confirmation, but also the necessary premise for our work. Born from the synergy between ASAlaser and the Department of Experimental and Clinical Biomedical Sciences of the University of Florence , the ASAcampus laboratory allows us to test the validity of our work and improve results over time. The result of the research is disseminated through conferences, supported thanks to important partnerships and disseminated through numerous scientific publications.Our medical devices for MLS ® Laser Therapy , Hilterapia ® and Magnetotherapy are built according to contents that we consider indispensable: advanced technologies and software, efficacy and safety, ergonomics and design. They allow for ever more targeted and personalized treatment methods. The effectiveness of our therapies is continuously tested thanks to the research carried out in ASAcampus whose results are constantly transferred to clinical applications.
ENDYMED PURE PLUS Input Power:100-120V, 50-60Hz, 2A or 220-240V, 50-60Hz, 1A Power Consumption:220 W Fuses:2 x 1.6A for 220V; 2 x 3.15A for 110V Output Power:Up to 50 Watts Output Frequency:1MHz Working Temperature:+10°C – +25°C Dimensions:(H x W x D) 600 x 305 x 365 mm Weight:10 kg GOOD THINGS COMES IN SMALL PACKAGES – THE PURE+ The Pure+ by Endymed Pure Plus, powered by our FDA cleared, patented 3DEEPRF technology. The PURE+ offers professional grade Fractional Skin Resurfacing and superior body, facial and neck tightening and contouring treatments, all on one easy to use, compact platform.The PURE+ offers complete flexibility with exchangeable treatment handpieces – one PURE+ console can be configured any way you like to provide you and your clients with the most effective and popular treatments available today.The PURE+ is offered in two configurations:FSR + TC: Fixed FSR handpiece + one exchangeable connector suitable for all TC handpieces: iFine, Small and Large TC Complete: Two exchangeable connectors on each side, suitable for all TC handpieces: iFine, Shaper, Small and LargeThe iFine treatment Handpiece – specially engineered to target fine lines and wrinkles found in the delicate thin – skin areas around the eyes, providing: Smoother, tighter skin around the eyes. Reduced under eye sagging and improved eye contour. Reduced hooding to reveal more of the eyelid. More youthful, less tired looking eyes. Softening of fine line enabling easier application of make-up.3Deep Small-Medium Handpiece Designed to treat wrinkles and lax skin on the face, neck and upper body.3Deep Fractional Skin Resurfacing Handpiece Specially designed for fractional skin resurfacing and treatment of skin roughness, hyperpigmentation, and wrinkles and scars on both facial and body. The FSR handpiece contains a matrix of 112 tiny electrodes, allowing for the first time simultaneous fractional micro-ablation of the epidermis, together with volumetric heating of 100% of the dermis. This technology provides the capability to differentiate between micro-ablation and dermal heating which appears to be the optimal multi-layer treatment to affect aging skin and atrophic acne scars.3Deep Shaper Handpiece Major innovation in RF skin tightening, body shaping and contouring, and cellulite treatment for large body areas. The handpiece’s unique engineered electrode surface is 40.7 cm2 allowing for shorter treatment times (20 minute abdomen treatment, 30 minute cellulite treatments for the thighs and buttocks). Deeper, controlled energy penetration tightens and firms the skin by stimulating the body’s natural collagen renewal process, providing better and more effective results.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: Avante Integra SP VSO2 Portable Anesthesia Machine $7,500.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Shopping cart close