| Description | Aerolase Lightpod Era Erbium Yag 2940nm. Includes: Handpiece, Handpiece Padding, Focusing Lens, Footswitch, Hard Carry Case, Treatment Protocol Manual, Operator Eyewear, Patient Eyeshield and 180 Day Warranty. | Providing high-quality diagnostic imaging services to your patients is high on your list of priorities. But there are limits to your budget and your space. That’s why we are excited to offer your customers the CARESTREAM DIRECTVIEW Vita CR System—a reliable, compact, tabletop imaging solution with a small footprint and light weight design. It allows seamless integration into your existing work flow, and helps increase efficiency and productivity, all at an affordable price. | CIRRUS HD-OCT 5000 is configured with the highest resolution visualization capabilities and sophisticated clinical applications such as Advanced RPE analysis to track retinal pigment epithelial integrity and Ganglion Cell Analysis to assess glaucomatous loss in the macula that may not be evident in the peripapillary region. The new FastTrac retinal tracking reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning. This feature enables the highest resolution B-Scans to be captured in identical locations from visit to visit providing precise assessment of change in targeted pathologies. | Superior, Comfortable Laser Hair RemovalLaser Hair Removal – An In-demand Procedureexcel HR combines a high-power 755 nm Alexandrite laser and Cutera’s proven long-pulse 1064 nm Nd:YAG laser for safe, effective high-volume hair removal on all skin types. The combination of wavelengths not only allows for effective hair removal, but is also a solution for epidermal pigmented lesions, vascular lesions and Cutera’s signature laser genesis skin revitalization procedure. | Recommended for all skin types, the PicoGenesis laser procedure is used to treat:• Brown spots
• Sun damage
• Age spots
• Melasma
• Hyperpigmenation
• Pigmented lesions | The Sequoia system’s advanced technologies are designed to make image acquisition easier, reduce exam time and increase overall efficiency. Along with many other included features, the Sequoia system offers Native, a patient specific imaging which adapts both phase and amplitude information of each unique patient’s properties which delivers a consistently better image across a broad range of patients. |
| Content | Aerolase Lightpod Era Erbium
Aerolase Lightpod Era Erbium Specifications :Laser Type:Er:YAG, pulsed
Wavelength:2940nm
Fluence Range:up to 1,200 mJ
Pulse Width:300-microseconds
Beam Profile:Up to 10mm
Power Source:115 VAC / 230 VAC, switchable
Internal Laser System Cooling:Air Cooling (patented)
Complete Laser Size:7 inch x 14 inch x 19 inch (15.2cm x 35.5cm x 48.3cm)
Weight:approx. 23lb (10kg)Profound rejuvenation in a single treatment with less downtime that fractional devices. The new standard for ablative rejuvenation.The Aerolase Lightpod Era Erbium represents a new revolution in skin rejuvenation as a high-precision 2940nm laser that delivers high-fluence in a collimated beam, utilizing a gentle 300-microsecond pulse duration. The Era uniquely allows for independent depth of ablation of shallow or deep indications (plus, a non-ablative mode) within a treatment site, as well as precision targeting of difficult contours of the nose and periocular areas. These controlled pulses allow for full ablation of the epidermis without damaging the dermis, which eliminates pinpoint bleeding, oozing, and excessive amounts of downtime while still achieving the stunning results historically only seen with C02 lasers. The LightPod Era operates without any per-treatment costs or consumables to keep your practice highly profitable.Complete Artistic Control LightPod Era allows you to address each patients individual anti-aging concerns by enabling tailored treatment for both deep and superficial indications without demarcation lines.Maximum Results, Minimal Downtime a single treatment session allows for comparable results to a series of treatments with fractional devices, but with less downtime. A single more aggressive treatment offers similar results to C02 without adverse effects or prolonged patient downtime.Precise Depth of Ablation unique control over complete epidermal renewal eliminates collateral thermal damage, damaging the dermis and ensures achieving desired, reproducible results for each patient.Minimal Adverse Effects unmatched results with no hyper- or hypopigmentation, no bleeding, no oozing, no scarring and no excessive downtime immensely boosts patient satisfaction.300-Microsecond Ablative Laser Technology
The LightPod Eras gentle 300-microsecond pulse is delivered in a unique collimated beam, which combines to allow for a number of advantages including:Independent depth of ablation within a treatment site
Less downtime and fewer treatments than fractional lasers
Less downtime and risk of adverse effects, yet comparable results to C02
Partial face treatments without demarcation lines
Precision targeting of difficult contours (nasal, periocular, perioral, scars, etc.)
No touching of the skin, which allows exceptional visual control, hygiene and treatment comfort
A new sub-ablative mode opens epidermal renewal to darker skin typesWith the Aerolase Lightpod Era Erbium, practitioners now have a single laser modality in a single handpiece that can effectively treat a range of cosmetic concerns from the most deeply wrinkled, photodamaged skin to the most superficial irregularities within a single treatment. LightPod Eras 300-microsecond laser technology enables precision within a gentle pulse. The 300-microsecond pulse duration delivers high energy within a short pulse duration, which allows the skin to cool in between pulses to prevent thermal overheating and collateral damage. Precise control (E-Figure 1), depth of ablation (E-Figure 2) and the ability for the skin to cool itself between pulses eliminates demarcation lines and allows predictable, reproducible outcomes. Published clinical data has shown that in comparison to other ablative technologies, the LightPod Era offers shorter downtime, a higher therapeutic window, and a lesser risk of complications such as pigmentary changes or scarring.In addition, partial area ablation of singular functional aesthetic units (E-Figure 3) is enabled due to the absence of port-treatment demarcation lines caused from thermal damage. This advances the traditional ablative lasers that need to treat entire areas to cover-up demarcations lines caused by excess thermal damage. The LightPod Era now allows for customized treatment solutions with minimized downtime.Clinical Applications :Wrinkles
Fine Lines
Smoke Wrinkles
Crows Feet
Deep Furrows
Tone & Texture
Sun Damage
Age Spots
Large Pores
Freckles
Scars
Minimization
Revision
Acne Scars
Traumatic Scars
Lesions
Nevi
Keratoses
Skin Tags & Milia
Xanthelasma2014 Aerolase Lightpod Era Erbium Yag 2940nm. Includes: Handpiece, Handpiece Padding, Focusing Lens, Footswitch, Hard Carry Case, Treatment Protocol Manual, Operator Eyewear, Patient Eyeshield and 180 Day Warranty. | Carestream Vita 25 Digital CR SystemCARESTREAM Vita Flex CR Systems are designed for small-to-midsize hospitals, clinics and practices that need compact digital solutions at an affordable price. With two options for throughput speed, Vita computed radiography systems offer in-house, high-quality digital imaging to fit your workflow. The flexible orientation makes it perfect for small spaces in offices or in mobile settings.System Beneits
Smaller size and weight
Multiple throughputs (30/45 PPH)
Ability to be positioned for horizontal or vertical feeds
Supports a number of cassette sizes
Uses Image Suite Software – easy-to-use platform
specially designed for the end userImage acquisition and management for CR and DR Systems
Image Suite V4 Software has set a new benchmark for workflow efficiency in smaller facilities. This robust software features an easy-to-use, touch-friendly interface, an enhanced set of tools, streamlined workflow and improved image quality. Our advanced “mini-PACS” module allows superb image management and analysis, and is now fully optional. Get the high-quality images you need with a system that’s a perfect fit – at very affordable price. Physical Specifications Carestream Vita 25 Digital CR System • Weight: 25 kg (55 lb) • Dimensions (W x D x H): 68.0 x 34.0 x 45.0 cm (26.7 x 13.4 x 17.7 in.) Power • Electrical Rating: 100-240 V AC 50/60 Hz • Maximum Power Consumption: 120 W • Power Consumption in Standby Mode: 42 W • Power Supply Conditions: AC Power 100~240 V AC,50/60 Hz, 1.5 A Kodak/Carestream Vita25 CR System:25 Plate Per Hour Reader
2, 14×17 Cassettes
PC, Keyboard, Monitor, & Mouse
Genesis Software
2 Year Warranty
Available with the following upgrades:PACS: 250GB & 2 Viewers
PACS: 450GB & 4 Viewers
Go from 25 to 45 Plates Per Hour
Additional 14×17 Cassettes
Additional 10×12 Cassettes | Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HDAdvancing Smart OCTfor Anterior Segment, Glaucoma and Retina- Anterior Segment Premier Module
- PanoMap Wide-Field Display
- Smart HD Scans
- En face report
Visualization at the speed of CIRRUSAnalyzing a single pathology from multiple views provides comprehensive insight and analysis of the clinical situation. How this helps you: - Spot small areas of pathology. Tightly spaced B-scans, (either 30 or 47 μm apart), in the cube ensure that small areas of pathology are imaged. For reference, a human hair is about 40-120 μm in diameter.
- Visualize the fovea. Scans that are spaced further apart than in the CIRRUS cube may miss the central fovea.
- Fuel for analysis. Millions of data points from the cube are fed into the Zeiss proprietary algorithms for accurate segmentation, reproducible measurements and registration for change analysis.
- Take the pressure off the operator. As long as the scan is placed in the vicinity of the fovea or optic nerve, the software automatically centers the measurements after the capture.
- See the tissue from different perspectives. View the cube data from all angles, with 3D rendering, OCT fundus images and Advanced Visualization™.
- Future ready. Previously captured CIRRUS cubes can be analyzed using new analyses.
Tracking at the speed of CIRRUSFastTrac™ reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning
With FastTrac, scan at the highest resolution at the same location at each visit. Assessment at the speed of CIRRUSMeasurement centering with FoveaFinder and AutoCenterOn the macula, the unique FoveaFinder technology ensures the ETDRS and ganglion cell plus inner plexiform layer measurement frameworks are centered on the fovea.AutoCenter™ function automatically centers the 3.4 mm diameter peripapillary RNFL calculation circle around the disc for precise placement and repeatable registration. The placement of the circle is not operator dependent. Accuracy, registration and reproducibility are assured. Manage at the speed of CIRRUS Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HDGuided Progression Analysis (GPA™) for Assessing RNFL and Optic Disc ChangeGPA™ compares RNFL thickness and optic disc measurements over time and determines if statistically significant change has occurred.Focal Progression Analysis – Up to 6 progression maps are compared to two baselines. Areas of statistically significant change are color-coded yellow when first noted and then red when the change is sustained over consecutive visits.
Trend Analysis with Rate of Change – RNFL thickness values are plotted over time. Trends are calculated and confidence intervals are shaded when rate of change is statistically significant.
| Cutera Excel HR 1064 755 Hair Removal SystemAlexandrite
Wavelength:755 nm
Maximum Energy:53J
Pulse Duration:3 ms
Spot Size:5-18 mm
Repetition Rate:2 HzNd Yag
Wavelength:1064 nm
Maximum Energy:80J
Pulse Duration:0.1 – 300 ms
Spot Size:3-12 mm
Repetition Rate:Up to 10 Hz
Cooling:Contact Sapphire
Aiming Beam:635 nm
Dimensions:35″ H x 12″ W x 24″ D
Electricial:200-240 VAC, 50/60 Hz, 20A/30ACooling:Contact Sapphire
Aiming Beam:635 nm
Dimensions:35″ H x 12″ W x 24″ D
Electricial:200-240 VAC, 50/60 Hz, 20A/30A
Superior, Comfortable Laser Hair Removal
Laser Hair Removal An In-demand Procedure
Global hair removal procedures are growing at a rapid pace. Laser hair removal has been among the top non-surgical procedures according to the American Society of Aesthetic Plastic Surgery and procedure revenue is anticipated to go to $1.35B by 20221. The industry often refers to laser hair removal as a gateway procedure as it offers an entry point into the aesthetic market for patients and practitioners alike.excel HR combines a high-power 755 nm Alexandrite laser and Cuteras proven long-pulse 1064 nm Nd:YAG laser for safe, effective high-volume hair removal on all skin types. The combination of wavelengths not only allows for effective hair removal, but is also a solution for epidermal pigmented lesions, vascular lesions and Cuteras signature laser genesis skin revitalization procedure.excel HR Technology
Proven Wavelengths
excel HR combines the gold standard laser wavelengths for hair removal. The 755 nm Alexandrite laser is highly absorbed by melanin making it an ideal solution for finer hair on skin types I-III. Because of the high melanin absorption characteristics, it has also been proven to provide long-term results on epidermal pigmented lesions.The 1064 nm Nd:YAG is the safest wavelength for permanent hair reduction on darker skin types and tanned skin. By selecting the appropriate spot size, this laser can also be used for treating facial and leg veins and perform laser genesis procedure.truPulse Delivery with Index Matching
Unique to Cutera, the truPulse technology delivers constant, sustained energy throughout the pulse duration to ensure consistent performance and proven clinical outcomes for your patients.excel HRs index matching delivery results in more efficient coupling of laser energy to target structures. Index matching allows backscattered light to escape, further protecting the epidermis from heat build-up while maintaining treatment efficacy.Superior Contact Cooling
excel HR utilizes sapphire contact cooling to provide continuous cooling, maximizing your patients comfort and treatment safety.2 In a patient preference study that measured comfort and satisfaction for laser hair removal, 100% of the patients preferred excel HR over a comparable, competitive laser hair removal procedure.321st Century Laser Hair Removal System
Developed by the innovative leader in aesthetic laser technology, excel HR laser hair removal system provides advanced premium hair removal solutions for every skin type. Combining a new high-power 755 nm Alexandrite laser, and CUTERAs proven long-pulse 1064 nm Nd:YAG laser, coupled with the superiority of sapphire contact cooling, excel HR redefines modern laser hair removal.This makes excel HR laser system an effective, safe and comfortable option for laser hair removal for the 21st century.Applications Cutera Excel HR 1064 755 Hair Removal System
– Hair removal
– Benign pigmented lesion removal
– Veins, facial
– Veins, leg
– Laser Genesis | Cutera Enlighten III Pico-Nano Second Tattoo RemovalThis next-generation PicoGenesis laser is an advanced, non-thermal way to treat pigmentary concerns, PicoGenesis harnesses a non-thermal, photomechanical effect paired with ultra-short—one trillionth of a second long—pulse durations. The perfect blend of technologies creates shockwaves that shatter pigments in the skin without damaging the surrounding tissue, while inducing dermal disruption and remodelling for true skin revitalisation.Unlike conventional laser toning that requires up to 15 treatment sessions and often lead to adverse side effects such as redness, swelling and itching. Thanks to the incorporated picosecond technology, in as few as three sessions you will experience a dramatic improvement in the reduction of pigmentation as well as a brighter, more uniform complexion in just 20 minutes—and all with no downtime! With entirely changeable parameters, this game-changing treatment an be used to benefit even the most challenging skin concerns, and can also effectively remove all colours of tattoos.Recommended for all skin types, the PicoGenesis laser procedure is used to treat : Cutera Enlighten III Pico-Nano Second Tattoo Removal• Brown spots
• Sun damage
• Age spots
• Melasma
• Hyperpigmenation
• Pigmented lesionsenlighten III combines multiple wavelengths (1064 nm, 532 nm and 670 nm) and picosecond + nanosecond pulse durations (750/660 ps + 2 ns) in a single platform for the treatment of unwanted multicolor tattoos, epidermal and dermal pigment, and skin revitalization across all skin types. Unlike conventional laser toning that require up to 15 treatment sessions and often lead to unpredictable results, PICO Genesis harnesses the power and flexibility of enlighten SR combined with its technical benefits in a dual delivery procedure to selectively shatter pigment and induce dermal disruption and remodeling for true skin revitalization in fewer than 3 sessions.“The enlighten laser system has been a game changer for my tattoo removal practice. I feel much more confident that we can deliver patients the results they have been wanting since laser tattoo removal was first invented.” | Siemens Acuson Sequoia 512 LCD Ultrasound Machine18″ Flat panel LCD Monitor–Progressive Media & Display II Package, Cardiac/OB/Vascular Calc. Package, Signature II Option, AUX, CPS Cardiology, CPS General Cadene Trigg Burst, Calc Data to MO, Card Cadence II Contrast Quant, Cornoary Flow reserve, Dicome Store/Print, DTI (Doppler Tissue Imaging), High HR ECG, MIS/MIF, Modality Worklist Native TEQ, Native TEQ, NTHI (Native Tissue Harmonics), Spectral TEQ, TEQ (Tissue Equalization), VVIFeatures- Shared Service
- Native Patient Specific Imaging
- Four Sight TEE view
- Axius quantitative strain rate imaging
- Cadence contrast pulse sequencing technology
- Native Tissue Harmonic Imaging
- Native TEQ ultrasound technology
- Color doppler, Color angio and b-color
- PW/CW Doppler
- M-Mode
- Folding Flat Panel Display
- DICOM capabilities
Applications- Abdominal
- Breast
- OB/GYN
- Vascular
- Pediatrics
- Cardiology
- Musculoskeletal
- Neonatal
Acuson Sequoia 512 Features:- Imaging: Gray-scale 2-D, M-mode, SST Color Doppler, Solo Spectral Doppler, 3-D Surface Rendering, Native Tissue Harmonic Imaging, Auto Doppler, M-Mode, PW Doppler, Color Doppler, Color Power Doppler
- 19" color CRT monitor
- Native tissue harmonic imaging (NTHI)
- DIMAQ: image management
- Advanced vascular analysis
- Advanced spatial compounding
- Native patient specific imaging
- Mitral valve assessment
- CPS contrast pulse sequencing technology
- Clarifying vascular enhancement technology
- High resolution color flow
- Vascular, and General Imaging calculation packages
- Coherent beamformer technology/spatial compounding
- Space/time resolution control
- Cine and zoom/RES
Compatible Ultrasound Probes and Transducers:- Acuson V5Ms TEE Probe
- Acuson 4C1 Curved Array Probe
- Acuson 6C2 Curved Array Probe
- Acuson 8C4 Curved Array Probe
- Acuson 4V1 Vector Array Probe
- Acuson EV-8C4 Endocavitary Probe
- Acuson EC-10C5 Endocavitary Probe
- Acuson 6L3 Linear Array Probe
- Acuson 8L5T Intraoperative Probe
- Acuson 8L5 Linear Array Probe
- Acuson 9L4 Linear Array Probe
- Acuson 15L8 Linear Array Probe
- Acuson 17L5 Linear Array Probe
The Sequoia 512 with LCD ultrasound machine uniquely minimizes automatic image optimization time by up to 80% to make way for an easier and speedier ultrasound test time as well as allow for a more confident diagnosis each time. As a patient-specific imaging ultrasound, it has a unique matched response capacity for accurate image quality, sharp clinical specificity, and optimized diagnostic outcomes that makes infinitesimal pathologies and other anatomical detail in the most difficult-to-image patients becomes more vivid and visible. |
Reviews
There are no reviews yet.