PERKASA MEDICAL

Free shipping worldwide. Orders over $200
Availability: In Stock

2010 Erchonia Zerona Per Click Unit

$5,200.00

This material can then be used by the cells in body for energy or filtered out of the body through the lymphatic system. During the clinical trials the average person lost 3.72 combined inches off of their hips, thighs, and waist in 6 treatments.

Other people want this. 15 people have this in their carts right now.

Description

2010 Erchonia Zerona Per Click Unit

Four separate histological studies were performed to assess the efficacy of laser in the emulsification (liquefaction) of fat. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were utilized to analyze adipose tissue. SEM and TEM images revealed the collapse of adipose arrangements subsequent to laser therapy. The voluminous state of an adipocyte cell is reduced due to the emulsification process. The fatty material is evacuated from the cell and moves into extracellular space. The voluminous nature of adipocytes due to the accumulation of fatty material is what gives rise to an enlarged subcutaneous fat region. ZERONA induces the formation of a transitory pore in the membrane of the fat cell. The pore enables the fatty material to seep out across the aperture and into extracellular space. The following images show the result of laser energy on a single fat cell and a group of fat cells.

2010 Erchonia Zerona Per Click Unit

As you can see the ZERONA treatment liquifies the fat and the cell dumps it into the intercellular space. There are two types of fat cells – Subcutaneous and Visceral.Subcutaneous fat is located directly above the skeletal muscle and below the skin. Its superficial placement is what ensures proper depth penetration of the laser energy. Patients containing a high volume of visceral fat (fat below the skeletal muscle) are not ideal candidates for this procedure. However, they may still contain subcutaneous fat; therefore, you can treat the individual by just ensuring they adopt a healthy diet to address the visceral fat.”

The technology is FDA Market-Cleared, non-invasive and clinically tested. Applied externally, the laser targets excess fat by emulsifying fatty tissue through the use of cold laser technology developed by Erchonia. It provides an alternative fat loss treatment without the adverse side effects associated with surgical and other weight loss procedures like liposuction and body wraps.

Condition:
 Used – Good
Brand:
 Erchonia Zerona
Model:
 Per Click Unit
Frequency (Hz): 50/60Hz
Power Supply Voltage: 100-240V

Reviews

There are no reviews yet.

Be the first to review “2010 Erchonia Zerona Per Click Unit”

Your email address will not be published. Required fields are marked *

Quick Comparison

Settings2010 Erchonia Zerona Per Click Unit removeACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER FOR SALE removeCARTESSA SKINWAVE TREATMENT SYSTEM FOR SALE removeLynton Lumina IPL HR Laser For Sale removeGE Logiq E R7 Portable Ultrasound Machine removeActive Optical Extra 818 IPL Hair Removal 2015 For Sale remove
Name2010 Erchonia Zerona Per Click Unit removeACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER FOR SALE removeCARTESSA SKINWAVE TREATMENT SYSTEM FOR SALE removeLynton Lumina IPL HR Laser For Sale removeGE Logiq E R7 Portable Ultrasound Machine removeActive Optical Extra 818 IPL Hair Removal 2015 For Sale remove
Image
SKU
Rating
Price $5,200.00 $6,500.00 $10,800.00 $11,250.00 $24,750.00 $7,200.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

DescriptionThis material can then be used by the cells in body for energy or filtered out of the body through the lymphatic system. During the clinical trials the average person lost 3.72 combined inches off of their hips, thighs, and waist in 6 treatments.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER includes: Handpiece, Footswitch, Operator Eyewear, Patient Eyewear, Cart, Key, Operator Manual, ultrasound gel, replacement fuses, replacement filtersCartessa SkinWave Treatment SystemThe Cartessa SkinWave Skin Treatment System combines an aqua-delivery system, skin revitalizing solutions and Hydrogen therapy for a multi-dimensional skincare treatment. Solutions rich in Alpha Hydroxy Acid (AHA), Beta Hydroxy Acid (BHA), Hyaluronic Acid and Hydrogen (H2) are infused deep into the skin, while gentle extraction removes impurities. It’s the ultimate compliment to brighten skin, improve vitality and tone. Cartessa Aesthetics teamed up with Eunsung Global manufacturer to exclusively bring Skinwave to the US. Eunsung Global is a South Korea–based, global leader focused on innovation in medical aesthetic equipment, present in over 70 countries and 100 partners worldwide.
  • This Multi-function system offers a wide range of treatments.
  • 1046nm long pulsed Nd:Yag treating hair removal, fungal nail and deep thread veins.
  • 650nm & 585nm IPL handpieces including for both hair removal, skin rejuvenation, thread veins, pigmentation and more.
  • This system can be added to with a 2940 fractional handpiece
  • Safety goggles supplied
  • Delivery, installation and warranty included.
LOGIQ e Needle Recognition Software Option which helps provide precise and accurate display of the needle, anatomy and motion even in Color and Power Doppler. This feature harnesses pattern recognition technology that recognizes and accurately reveals the structure of a needle within the anatomy, without distortion of the needle and compromising the target.2015 Active Optical Extra 818 IPL Hair Removal and Skin Rejuvenation; Excellent Cosmetic and Operating Condition, Very Lightly Used for Demonstrations Only, Single Owner; Included Handpieces and Pulse Counts: Hair Removal Handpiece = 6,617 Pulses, Facial Handpiece = 2,190, Life for Each Handpieces is 250,000 Pulses.
Content

2010 Erchonia Zerona Per Click Unit

Four separate histological studies were performed to assess the efficacy of laser in the emulsification (liquefaction) of fat. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were utilized to analyze adipose tissue. SEM and TEM images revealed the collapse of adipose arrangements subsequent to laser therapy. The voluminous state of an adipocyte cell is reduced due to the emulsification process. The fatty material is evacuated from the cell and moves into extracellular space. The voluminous nature of adipocytes due to the accumulation of fatty material is what gives rise to an enlarged subcutaneous fat region. ZERONA induces the formation of a transitory pore in the membrane of the fat cell. The pore enables the fatty material to seep out across the aperture and into extracellular space. The following images show the result of laser energy on a single fat cell and a group of fat cells.2010 Erchonia Zerona Per Click UnitAs you can see the ZERONA treatment liquifies the fat and the cell dumps it into the intercellular space. There are two types of fat cells – Subcutaneous and Visceral.Subcutaneous fat is located directly above the skeletal muscle and below the skin. Its superficial placement is what ensures proper depth penetration of the laser energy. Patients containing a high volume of visceral fat (fat below the skeletal muscle) are not ideal candidates for this procedure. However, they may still contain subcutaneous fat; therefore, you can treat the individual by just ensuring they adopt a healthy diet to address the visceral fat.”The technology is FDA Market-Cleared, non-invasive and clinically tested. Applied externally, the laser targets excess fat by emulsifying fatty tissue through the use of cold laser technology developed by Erchonia. It provides an alternative fat loss treatment without the adverse side effects associated with surgical and other weight loss procedures like liposuction and body wraps.
Condition:
 Used - Good
Brand:
 Erchonia Zerona
Model:
 Per Click Unit
Frequency (Hz): 50/60Hz
Power Supply Voltage: 100-240V
Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II Handpiece (Optional):Facial Treatments Pulse Interval/Repetition Rate:0.5 – 2 Seconds Maximum Output Treatment Pattern:22 Joule /cm 2 Output Power:11-31 Joule / cm 2 , up to 4000 W Cooling System:Improved Air Cooling Control:Advanced Software Interface Lamp’s Life Span:200,000 Flashes (minimum) Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2) Wavelength:420 – 1,100 nm Weight:88.18 lbs (40Kg) (including stand) Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm) Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz Max Mains Power:600 VA Treatments Variety: Skin Rejuvenation Pigmentation Treatment Acne Treatment Hair Removal Hair Removal – Deep Follicles Hair Removal – Sensitive Skin Vascular (Facial) Treatment Tattoo Removal ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERr uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated. 12 Programs 1 – Very Dark Skin, Fitzpatrick Skin Type IV 2 – Dark Skin, Fitzpatrick Skin Type IV 3 – Dark Skin, Fitzpatrick Skin Type III 4 – Dark Skin, Fitzpatrick Skin Type III 5 – Medium Skin, Fitzpatrick Skin Type II 6 – Medium Skin, Fitzpatrick Skin Type II 7 – Light Skin, Fitzpatrick Skin Type II 8 – Light Skin, Fitzpatrick Skin Type I 9 – Very Light Skin, Fitzpatrick Skin Type I 10 – Very Light Skin, Fitzpatrick Skin Type I 11 – Very Light Skin, Fitzpatrick Skin Type I 12 – High Power, Fitzpatrick Skin Type IActive Optical Systems Optima 518 IPL LaserOptima-518-Classic The Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERNew Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece: * Faster treatments – up to 0.5 Seconds Between pulses. * Real-time handpiece temperature control. * Contemporary and stylish design. * Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER Approvals * CE MDD Intl. Medical Standard * FDA U.S. Safety Standard * ISO-13485 Med. Production STD * IEC 60-601-1 Medical Safety STD * CFS Gov. Health Approval * CSA Can. & U.S. Safety App * TGA Australian health STD.CARTESSA SKINWAVE TREATMENT SYSTEMCARTESSA SKINWAVE TREATMENT SYSTEM, skin revitalizing solutions and Hydrogen therapy for a multi-dimensional skincare treatment. This professional skincare machine incorporates solutions rich in Alpha Hydroxy Acid (AHA), Beta Hydroxy Acid (BHA), Hyaluronic Acid and Hydrogen (H2) using hydradermabrasion. Solutions are infused deep into the skin, while gentle extraction removes impurities. The Skinwave facial is the ultimate compliment to brighten, improve vitality and tone in all skin types.Cartessa Aesthetics teamed up with Eunsung Global manufacturer to exclusively bring Skinwave to the US. Eunsung Global is a South Korea–based, global leader focused on innovation in medical aesthetic equipment, present in over 70 countries and 100 partners worldwide.CARTESSA SKINWAVE TREATMENT SYSTEM Applications of the Skinwave:Skin Revitalization Tone & Brighten Cleanse & Exfoliate Oil & Acne Control HydrationCartessa SkinWave Treatment SystemThe Cartessa SkinWave Skin Treatment System combines an aqua-delivery system, skin revitalizing solutions and Hydrogen therapy for a multi-dimensional skincare treatment. Solutions rich in Alpha Hydroxy Acid (AHA), Beta Hydroxy Acid (BHA), Hyaluronic Acid and Hydrogen (H2) are infused deep into the skin, while gentle extraction removes impurities. It’s the ultimate compliment to brighten skin, improve vitality and tone. Cartessa Aesthetics teamed up with Eunsung Global manufacturer to exclusively bring Skinwave to the US. Eunsung Global is a South Korea–based, global leader focused on innovation in medical aesthetic equipment, present in over 70 countries and 100 partners worldwide.Hydrogen Therapy Clean Skinwave’s aqua-delivery system starts with a Hydrogen-enriched water infusion. The high concentration of Hydrogen reacts with active Oxygen that is linked to drying and aging. By forming newly-bound water molecules that are extracted via the radial tips, this unique Skinwave step provides antioxidant and moisturization benefits and reduces inflammation.Target Skin Concerns Three nutrient-rich solutions optimize skin revitalization. Skinwave infuses deep into the skin Alpha Hydroxy Acid (AHA), Beta Hydroxy Acid (BHA) and Hyaluronic Acid to address top skincare needs: exfoliating, oil control and moisturization. Dial-up the volume of one of these solutions to offer a more customizable treatment.Multi-Dimensional Experience Two additional handpieces round out this multi-dimensional aesthetic treatment. Electrical pulse hand-piece open pores to maximize solution absorption with red and blue LED light for targeted treatments. Double-lifting handpiece activates lymphatic circulation, provides muscle relaxation, skin tightening and lifting effects.

Lynton Lumina IPL HR Laser

2013 Lynton Lumina IPL HR Laser Hair Removal 650nm 585nm 1064 YAG Beauty MachineIn very good condition and full working order Purchase new in December 2013, so less than a year old Laser has minimal use total count of 29427 from newPlease click HERE for further information Included:- 1 x 2013 Lynton Lumina IPL YAG Laser Hair Removal Beauty Machine 1 x Lynton 650 IPL Handpiece in protective storage box – Total Handpiece Shots 21600 1 x Lynton 585 Plus IPL Vascular Handpiece in protective storage box – Total Handpiece Shots 385 1 x Lynton 1064 YAG Laser Vascular Handpiece with 3mm, 6mm, 8mm tips in protective storage box – Total Handpiece Shots 7442 1 x Set of 3 IPL light guides in protective storage boxFor the following treatments 650nm Hair removal 650nm C.F.TMachine can do the following 585nm Vascular Plus 585nm Pigmentation Plus 585nm Photorejuvenation Plus 585nm Acne Plus The ultimate ‘build as you grow’ laser & IPL machine, offering practitioners the opportunity to dramatically increase and extend their treatment portfolio, without having to purchase numerous devices. British manufactured and listed on the NHS Supply Chain, the LUMINA offers the UK’s most in-demand treatments; hair removal, tattoo removal, anti-ageing and skin resurfacing.Highly versatile, and with numerous revenue capabilities, the Lumina delivers fast and clinically effective treatment results with superior efficacy. As the best-selling multi-function aesthetic machine, the LUMINA has a proven track record of building, growing and establishing clinics as the No.1 in their area.As our flagship machine, and the product of over 20 years expertise in the design, development and manufacture of laser/IPL systems, the LUMINA is specifically designed to be adaptable to address emerging applications. As well as unrivalled laser technology, the LUMINA has a built-in patient database and parameter printer, and benefits from its easy-to-use touchscreen. 1. Intense Pulsed Light (IPL): the perfect combination of hair removal and skin rejuvenation treatments come as standard with the LUMINA system via its 585 & 650 handpieces.Hand-piece Type Wavelength(s) Maximum Fluence Treatments Spot Sizes Maximum rep. rate 585 Intense Pulsed Light 550 – 1100nm 50J/cm2 Superficial Vascular Superficial Pigmentation Active Acne Skin-rejuvenation 1x1cm 2.5x1cm 5x1cm 1cm circular 1Hz 650 Intense Pulsed Light 625 – 1100nm 40J/cm2 Hair removal (1 to 5) Collagen treatment 1x1cm 2.5x1cm 5x1cm 1cm circular 1Hz 650 Advance IPL hand-piece, which has been designed to provide faster results in hair removal of finer, lighter hairs found on the face and navel. The 650 Advance hand-piece has software optimised for the greater power it delivers, allowing experienced practitioners to treat finer and fairer hairs successfully, in skin type 1 to 3 clients in a single or dual pulse mode.

GE Logiq E R7 Portable Ultrasound Machine

The NextGen LOGIQ combines the high performance of a console system with the portability of a laptop. GE Healthcare’s compact system is designed for general imaging, musculoskeletal, anesthesiology, interventional, emergency, and critical care applications.It provides ultrasound imaging with precise anatomical detail at a variety of depths. The system includes innovative features that help simplify interventional procedures.LOGIQ e Needle Recognition Software Option which helps provide precise and accurate display of the needle, anatomy and motion even in Color and Power Doppler. This feature harnesses pattern recognition technology that recognizes and accurately reveals the structure of a needle within the anatomy, without distortion of the needle and compromising the target.Also includes the ability to adjust needle gain and angle.
  • Standard package includes AC power cord (USA)
  • internet cord 3 meter in length CAT-5 type
  • PC to HUB structure
  • system software on USB
  • Optional Function Key Label
  • Ultrasound Transmission Gel .25L
  • English Basic Service Manual CD and English User Guide and AIUM booklet.
The following scanning modes are included:
  • B-mode
  • M-mode
  • Anatomical M-mode
  • Color flow mode
  • Power Doppler imaging
  • Pulsed wave Doppler and Ophthalmic
Features:The NextGen LOGIQ ecombines the high performance of a console system with the portability of a laptop. GE Healthcare’s compact system is designed for general imaging, musculoskeletal, anesthesiology, interventional, emergency, and critical care applications.Display Screen:
  • 15 in High-Resolution Color LCD
  • Resolution: 1024 x 768
  • Horizontal/Vertical viewing angle: +/-80 degree
  • Brightness AdjustmentIntegrated Speakers
  • Audio Volume Adjustment
  • Interactive Dynamic Software Menu
Console Design:
  • Laptop Style
  • Lithium Ion Battery
  • Integrated Solid State Drive
  • CPU – Intel Duo Core
  • Operating System – Microsoft® Windows® 7
Console Interfaces:
  • DC Power Input
  • USB 2.0 (3)
  • LAN 10/100/1000 BaseT
  • Docking Cart Connector
  • HDMI
Standard Features:
  • Integrated Solid State Drive
  • Automatic Optimization
  • CrossXBeamTM
  • Speckle Reduction Imaging (SRI-HD)
  • Virtual Convex/Virtual Apex
  • Fine Angle Steer
  • HD Zoom (Write Zoom)
  • Coded Harmonic Imaging (CHI)
  • Raw Data Processing
  • Quicksave
  • On-board User Manual (Help)
  • InSiteTM ExC capability
  • Loop storage—from live scanning and from memory
  • Patient Information Database
  • Customizable User Interface
  • Full M&A Calculation Package with Real Time Auto Doppler Calculations
  • Vascular Calcs
  • Cardiac Calcs
  • OB Calcs and Tables
  • Fetal Trending
  • Multi Gestational Calcs
  • Musculoskeletal and Hip Dysplasia Calcs
  • Gynecological Calcs
  • Urological Calcs
  • Renal Calcs
  • Small Parts Calcs
  • Rheumatology Calcs
  • Pediatric Calcs
  • Report Writer Package
 Software Options:
  • easy3D
  • LOGIQ View
  • Needle Recognition
  • Stress Echo
  • eSmart Trainer
  • Auto IMT
  • DICOM® 3.0 Connectivity/Encrypted DICOM
Specifications: Console Dimensions Height
  • 70 mm (2.75 in) console only
  • 100 mm (3.94 in) with handle
Width
  • 295 mm (11.61 in) console only
  • 343 mm (13.50 in) with handle
Length
  • 346 mm (13.62 in) console only
  • 375mm (14.76 in) with handle
Weight with Battery: Approximately 5.2 Kg (11.5 lbs)Operator Keyboard
  • Alphanumeric Keyboard
  • Ergonomic Hard Keys
  • Backlight Keys
Display Screen
  • 15 in High-Resolution Color LCD
  • Resolution: 1024 x 768
  • Horizontal/Vertical viewing angle: +/-80 degree
  • Brightness Adjustment
  • Integrated Speakers
  • Audio Volume Adjustment
  • Interactive Dynamic Software Menu
Console Electrical Power
  • Voltage: 100-240 V AC
  • Frequency: 50/60 Hz
  • Power: Max. 130 VA
Applications:GE Logiq E R7 Portable Ultrasound Machine
  • Abdomen
  • Cardiac
  • Gynecology
  • Musculoskeletal
  • Obstetrical
  • Nerve Block
  • Pediatric
  • Small Parts
  • Urological
  • Vascular
  • Rheumatology
  • Emergency Medicine
  • Cardiac intra-operative

Active Optical Extra 818 IPL Hair Removal 2015

Handpieces:Hair Removal Handpiece and Facial Handpiece Chilled Tip:Up to 4c Pulse Interval:0.5~2 Seconds Output Power:11-31 joule/cm2, upto 4,000W Cooling System:Revolutionary dual cooling Control:Intuitive touch screen control Lamp’s Life Span:250,000 Flashes (Universal), 200,000 Flashes (Facial) Treatment Area:7.5 cm2 (15*50mm) Universal, 4.5 cm2 (15*30mm) Facial Wavelength:420-1100 nm Weight:42Kg (including Stand, if device is not a table top) Dimensions:44cm x 45cm x 100cm
Extra-818Skin Rejuvenation Pigmentation Treatment Acne Treatment Hair Removal Vascular (Facial) TreatmentThe Extra – 818 is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features: * Contemporary touch screen control * Built-in Patch Test procedure for examining the optimal energy level * A stunning number of 450,000 flashes in both lamps.The Extra – 818, based on Active’s GEM-PL technology, sets sets a specific Pulse Pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.The combination of tested treatment protocols with high end engineering makes the Extra – 818 the perfect device for leading clinics.Revolutionary Cooling System The Extra – 818 has a dual cooling system, controlled and monitored in order to ensure long lifetime to the lamp and a comfortable treatment to the patient.Competitive cooling systems “freeze” the skin so that during the treatment the skin temperature will rise to a bearable level. However, this “freezing” temperature might limit the results because the follicles will not reach the coagulation temperature. To ensure optimal results Active installed a special Processor that prevents overcooling the skin and maintains a uniform low temperature of the “glass” throughout the treatment. This revolutionary system enables the Extra – 818 to provide best results with optimal patient comfort.Research Program Active Optical Extra 818 IPL Hair Removal 2015  For clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31Jcm2 with high intensity of 4,000W.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: 2010 Erchonia Zerona Per Click Unit $5,200.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Shopping cart close