| Content | Syneron-Candela Vbeam Prima cosmetic laser
Our new VBeam Prima is particularly recommended for broken capillaries, rejuvenating skin with sun damage or photo ageing, rosacea, red scars and port wine stains.The Vbeam Prima is a highly efficient pulsed dye laser with dual wavelengths, dual cooling systems, giving a better and faster treatment experience overall. It has a number of indications for both face and body, including benign vascular and pigmented lesions, facial telangiectasia, and rosacea, and is a treatment with high patient tolerability and a low incidence of side effects.Rosacea is a common skin condition that is historically difficult to treat and can lead to redness, flushing and broken blood vessels, often in the central face. However, the VBeam Prima, with its 595 and 1064nm wavelengths, offers a complete treatment even for persistent rosacea with larger vessels affected.VBeam Prima Technology
Pulsed Dye Lasers deliver an intense but gentle burst of light into selectively targeted areas of the skin. The light is absorbed by specific blood vessels or melanin pigmented areas in the dermis. With its efficient cooling system and re-engineered hand piece, the VBeam Prima is the next generation pulse dyed laser.   Pictured above: Figures 1A, 2A & 4A – baseline before photos. Figues 1B, 2B & 4B were taken at the 2 month follow up post 4 treatments.What to expect
It is recommended to avoid sun exposure before and throughout treatment to maximize results. A sunblock of SPF 30 or higher should be worn daily during this time.At treatment time, your skin is firstly cleansed to remove any makeup, moisturising lotion and natural oils. The laser’s built-in cooling mechanisms will make the treatment more comfortable so there is no need for local anaesthetic. The epidermis of the skin is protected by the VBeam’s exclusive dynamic cooling method, DCD, which sprays a cooling mist onto the targeted area of skin before each laser pulse, maximising comfort and protecting the skin during treatment. As the laser pulses energy into the skin, you may feel a temporary warm or stinging sensation, which is very tolerable.There may be some redness or mild swelling in the treated area immediately following treatment, and this usually goes away in a few hours. Occasionally some minor bruising may occur, but this is transient and usually disappears in three to five days.Beneficial results are usually noted straight away, and often patients comment they feel a firming or tightening of the treated area. How long the results last will depend on many factors, including the condition being treated and the patient’s lifestyle. For example, if you have sunspots removed, and you continue to spend time in the sun without adequate skin protection, it is likely that the sunspots will return.Indications Syneron-Candela Vbeam Prima cosmetic laser
The VBeam Prima offers a platform capable of treating a wide range of indications, including:- acne scarring
- benign vascular lesions
- benign pigmented lesions
- benign cutaneous lesions
- inflammatory acne vulgaris
- facial telangiectasia
- deep blue veins
- venous lakes
- wrinkles
- rosacea
- photo ageing
| Fotona XP Spectro Laser GeneratorThe Fotona XP Spectro laser offers an industry leading number of treatments from its advanced platform. The Fotona XP Spectro is an ideal choice for new clinics and clinics wishing to advance to a Fotona laser system from their current equipment.Not looking for a new Laser? See our Used-Laser Sales DirectoryThe Fotona XP Spectro laser offers high quality, fast, efficient treatments in the fields of aesthetics and surgery without compromising efficacy.The Fotona XP Spectro laser system has a 35 watt Nd:YAG engine offering different pulse configurations to be able to offer a wide range of applications at no extra cost and no need for additional hand pieces of software.Non-ablative Nd:YAG lasers are a extremely popular choice of laser in an extremely lucrative marketplace. Nd:YAG is proven as a gold standard in hair removal, skin rejuvenation, vascular treatments and much more. Fotona Xp Spectro Nd:YAG laser emits laser energy at 106nm which is proven to minimize discomfort while showing exceptional efficiently and long term results Features:Fotona XP Spectro Laser Generator
* Highest Performance
* Gold standard ND:YAG lasers
* Optional QCW Nd:YG laser
* Multiple applications
* Advanced scanner for greater Precision, Speed and Efficacy
* FRAC3 modality
* User friendly
* Massive earning potential
* Ability to treat all skin types safely and effectively Key Treatments:
* Laser Hair removal
* Rosacea treatments
* Fine wines and Wrinkles
* Laser peels
* Acne treatments
* Laser assisted lipolysis
* Laser assisted Hyperhidrosis
* Onychomycosis
* Skin tightening, tonng and texturing
* Endovenous laser
* Vascular legions
* Thread veins
* FRAC3
* Pigmentation
* Verrucae Technical Data:
* Laser wavelength:1064 nm
* Max. average power:35 W
* Pulsewidth range:PULSE: 0.1 to 50 ms, QCW: 0.1 to 2 ms
* Max. frequency:PULSE: 75 Hz, QCW*: 100 Hz
* Manual spotsizes:2 to 10 mm
* Scanner spotsizes:3 mm*, 6 mm, 9 mm*
* Scanner area:42 cm²
* Beam delivery type:Optical fiber Comes with:
* 5 Years Full Parts and Labour Warranty
* 3 pairs of laser safety goggles
* Standard Nd:YAG hanpiece (R33)
* Training and ongoing support
* Competative rates for clinic consumables | Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
The Laser uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IOptima-518-Classic Active Optical Systems Optima 518 IPL LaserThe Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. | Cutera Excel HR 1064 755 Hair Removal SystemAlexandrite
Wavelength:755 nm
Maximum Energy:53J
Pulse Duration:3 ms
Spot Size:5-18 mm
Repetition Rate:2 HzNd Yag
Wavelength:1064 nm
Maximum Energy:80J
Pulse Duration:0.1 – 300 ms
Spot Size:3-12 mm
Repetition Rate:Up to 10 Hz
Cooling:Contact Sapphire
Aiming Beam:635 nm
Dimensions:35″ H x 12″ W x 24″ D
Electricial:200-240 VAC, 50/60 Hz, 20A/30ACooling:Contact Sapphire
Aiming Beam:635 nm
Dimensions:35″ H x 12″ W x 24″ D
Electricial:200-240 VAC, 50/60 Hz, 20A/30A
Superior, Comfortable Laser Hair Removal
Laser Hair Removal An In-demand Procedure
Global hair removal procedures are growing at a rapid pace. Laser hair removal has been among the top non-surgical procedures according to the American Society of Aesthetic Plastic Surgery and procedure revenue is anticipated to go to $1.35B by 20221. The industry often refers to laser hair removal as a gateway procedure as it offers an entry point into the aesthetic market for patients and practitioners alike.excel HR combines a high-power 755 nm Alexandrite laser and Cuteras proven long-pulse 1064 nm Nd:YAG laser for safe, effective high-volume hair removal on all skin types. The combination of wavelengths not only allows for effective hair removal, but is also a solution for epidermal pigmented lesions, vascular lesions and Cuteras signature laser genesis skin revitalization procedure.excel HR Technology
Proven Wavelengths
excel HR combines the gold standard laser wavelengths for hair removal. The 755 nm Alexandrite laser is highly absorbed by melanin making it an ideal solution for finer hair on skin types I-III. Because of the high melanin absorption characteristics, it has also been proven to provide long-term results on epidermal pigmented lesions.The 1064 nm Nd:YAG is the safest wavelength for permanent hair reduction on darker skin types and tanned skin. By selecting the appropriate spot size, this laser can also be used for treating facial and leg veins and perform laser genesis procedure.truPulse Delivery with Index Matching
Unique to Cutera, the truPulse technology delivers constant, sustained energy throughout the pulse duration to ensure consistent performance and proven clinical outcomes for your patients.excel HRs index matching delivery results in more efficient coupling of laser energy to target structures. Index matching allows backscattered light to escape, further protecting the epidermis from heat build-up while maintaining treatment efficacy.Superior Contact Cooling
excel HR utilizes sapphire contact cooling to provide continuous cooling, maximizing your patients comfort and treatment safety.2 In a patient preference study that measured comfort and satisfaction for laser hair removal, 100% of the patients preferred excel HR over a comparable, competitive laser hair removal procedure.321st Century Laser Hair Removal System
Developed by the innovative leader in aesthetic laser technology, excel HR laser hair removal system provides advanced premium hair removal solutions for every skin type. Combining a new high-power 755 nm Alexandrite laser, and CUTERAs proven long-pulse 1064 nm Nd:YAG laser, coupled with the superiority of sapphire contact cooling, excel HR redefines modern laser hair removal.This makes excel HR laser system an effective, safe and comfortable option for laser hair removal for the 21st century.Applications Cutera Excel HR 1064 755 Hair Removal System
– Hair removal
– Benign pigmented lesion removal
– Veins, facial
– Veins, leg
– Laser Genesis | Fotona XS Dynamis Pro Multi-Application LaserOVERVIEWTechnology for Next Generation Resurfacing
With advanced treatment attributes and fully customizable settings, Fotona’s XS Dynamis offers true 3rd generation Er:YAG laser skin resurfacing. The XS Dynamis represents a complete rejuvenation solution. Its functions range from superficial to deep peels, from non-ablative to fully ablative and from full-field to fractional resurfacing. Resurfacing has Never Been as VersatileWith the XS Dynamis you can be your own artist; reverse the effects of aging and give skin a healthy, young look and feel. Over 20 treatment pre-sets can be accessed and further fine-tuned using digital ablation and coagulation depth indicators to gain predictable outcomes – one of the system’s strongest points. Complete ablation and coagulation control enables treatments to be tailored to each specific skin condition to achieve perfect results in both full-field and fractional resurfacing. The XS Dynamis can even be used with laser scar revision treatments. Acne scars in particular respond well to gentle Er:YAG laser resurfacing. Perfect for Pigmented Lesions Fotona XS Dynamis Pro Multi-Application LaserIn addition to skin resurfacing, the XS Dynamis’ high-performance Er:YAG laser is well equipped to handle a range of other applications in aesthetics and dermatology. The XS Dynamis can safely and effectively remove pigmented lesions like keratoses and moles through gentle ablation of the epidermis and superficial dermis in a controlled and relatively bloodless manner. Clinical studies have shown that Er:YAG lasers are very effective for the treatment of keratoses, with a clinical and histological improvement of up to 93% after just a single treatment. A Star Performer in GynecologyFotona’s Er:YAG laser wavelength is also highly useful for the treatment of lesions of the uterine neck and vagina, as well as HPV lesions, pigmentations and neoplasias. The XS Dynamis offers many benefits in gynecological treatments, including non-invasive, high-precision procedures with little or no pain, and often without anesthesia. Because of its non-contact, sterilizing capability it can even be used on infected tissue, with total re-epithelization and fast wound healing. | DENTSPLY SIRONA CEREC PRIMEMILLSpeedEngineered for speed and precision, the new CEREC Primemill inherits the proven strength of its predecessor and raises its powerful performance to entirely new heights.You can now mill zirconia restorations in Super Fast milling mode in around 5 minutes, cutting processing times by more than half. The improved grinding mode for high quality glass ceramics also grinds the material faster than ever before. The result? Satisfied patients and high productivity.QualityDENTSPLY SIRONA CEREC PRIMEMILL A combination of new electronics, software, motors and mechanical components contributes to finer resolution and enhanced dynamics. This results in outstanding restoration margins and surface details – for extremely precise results.The new highly accurate 0.5 mm milling tool reliably delivers first class clinical results. Switch to Extra Fine milling mode for a higher level of detail with occlusal fissures and interdental areas on bridges.VersatilityDENTSPLY SIRONA CEREC PRIMEMILL Welcome to a world where you‘re spoiled for choice! The new CEREC Primemill combines wet and dry milling and wet grinding. No matter the indication, with CEREC Primemill you can select from a broad range of material options from validated partners providing the flexibility and predictability you need to offer patients the best possible treatment.Choose from the full spectrum of machining options, including dry and wet milled zirconia, or wet grinding of glass and hybrid ceramics.ConvenienceDENTSPLY SIRONA CEREC PRIMEMILL The new 7” touch interface with user guidance guides operators step-by-step through the workflow, key maintenance procedures and other routine tasks, so you can delegate milling with complete peace-of-mind. The integrated block scanner is a time-saving new feature that automatically scans material blocks with compatible data matrix codes and records the information, including type, size, color and zirconia enlargement factor. All CEREC Primemill tools are fitted with a color-coded RFID chip that is read by the RFID tool reader, feeding into the tool status display, alerting the user if a tool needs replacing. This ensures all tools are performing at optimal levels. A LED light strip indicates unit status and milling and grinding progress.The all-new CERECThe latest generation of our CEREC system sets new standards so you can offer your patients an unmatched combination of single-visit dentistry and excellent quality.A unique solutionThe CEREC system comprises world-class components that interact perfectly ensuring seamless workflows. With CEREC Primescan, CEREC Software 5 and CEREC Primemill, digital chairside dentistry is faster, easier and more reliable than ever before.Outstanding resultsAfter 35 years of continuous optimization, CEREC gives you the options you need to treat multiple indications with the confidence that comes from outstanding results.
Designed to stand out – and fit inThe new CEREC Primemill does not just communicate seamlessly with other CEREC devices, but its sleek design is also the perfect match – and the ideal look for a progressive dental practice. |
Reviews
There are no reviews yet.