| Description | | Candela GentleMAX ProEstablished in 1970, Candela is a leading US-based global medical aesthetic device company with headquarters in Wayland, Massachusetts. The company’s technologies enable physicians to provide advanced energy-based solutions for a broad range of medical-aesthetic applications including benign vascular and pigmented lesions, scars, hair removal, facial resurfacing, wrinkle reduction, women’s health treatments, tattoo removal, acne, leg veins, cellulite, and body shaping. | Recommended for all skin types, the PicoGenesis laser procedure is used to treat:• Brown spots
• Sun damage
• Age spots
• Melasma
• Hyperpigmenation
• Pigmented lesions | Fotona XP Specto, Nd:YAG laser systemFotona’s new XP Spectro laser generator is the one of the latest models of Fotona to hit the market combining the industry recognised gold standard, long=pulse and quasi-continuous wave in a single multi-application laser generator. This combination of technology allows the client to integrate non-ablative aesthetics with surgical techniques. | New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort. | Dynamis Pro Laser – XS Line
The Fotona XS Dynamis is a fully customisable Er:YAG laser (erbium) which represents a complete rejuvenation and resurfacing solution. It has a range of modes to allow alteration of the depth of laser peels; as well as offering, non-ablative treatments, ablative treatments and fractional treatments. |
| Content | Syneron-Candela Vbeam Prima cosmetic laser
Our new VBeam Prima is particularly recommended for broken capillaries, rejuvenating skin with sun damage or photo ageing, rosacea, red scars and port wine stains.The Vbeam Prima is a highly efficient pulsed dye laser with dual wavelengths, dual cooling systems, giving a better and faster treatment experience overall. It has a number of indications for both face and body, including benign vascular and pigmented lesions, facial telangiectasia, and rosacea, and is a treatment with high patient tolerability and a low incidence of side effects.Rosacea is a common skin condition that is historically difficult to treat and can lead to redness, flushing and broken blood vessels, often in the central face. However, the VBeam Prima, with its 595 and 1064nm wavelengths, offers a complete treatment even for persistent rosacea with larger vessels affected.VBeam Prima Technology
Pulsed Dye Lasers deliver an intense but gentle burst of light into selectively targeted areas of the skin. The light is absorbed by specific blood vessels or melanin pigmented areas in the dermis. With its efficient cooling system and re-engineered hand piece, the VBeam Prima is the next generation pulse dyed laser.   Pictured above: Figures 1A, 2A & 4A – baseline before photos. Figues 1B, 2B & 4B were taken at the 2 month follow up post 4 treatments.What to expect
It is recommended to avoid sun exposure before and throughout treatment to maximize results. A sunblock of SPF 30 or higher should be worn daily during this time.At treatment time, your skin is firstly cleansed to remove any makeup, moisturising lotion and natural oils. The laser’s built-in cooling mechanisms will make the treatment more comfortable so there is no need for local anaesthetic. The epidermis of the skin is protected by the VBeam’s exclusive dynamic cooling method, DCD, which sprays a cooling mist onto the targeted area of skin before each laser pulse, maximising comfort and protecting the skin during treatment. As the laser pulses energy into the skin, you may feel a temporary warm or stinging sensation, which is very tolerable.There may be some redness or mild swelling in the treated area immediately following treatment, and this usually goes away in a few hours. Occasionally some minor bruising may occur, but this is transient and usually disappears in three to five days.Beneficial results are usually noted straight away, and often patients comment they feel a firming or tightening of the treated area. How long the results last will depend on many factors, including the condition being treated and the patient’s lifestyle. For example, if you have sunspots removed, and you continue to spend time in the sun without adequate skin protection, it is likely that the sunspots will return.Indications Syneron-Candela Vbeam Prima cosmetic laser
The VBeam Prima offers a platform capable of treating a wide range of indications, including:- acne scarring
- benign vascular lesions
- benign pigmented lesions
- benign cutaneous lesions
- inflammatory acne vulgaris
- facial telangiectasia
- deep blue veins
- venous lakes
- wrinkles
- rosacea
- photo ageing
| 2017 Candela GentleMAX Pro Device DetailsThe Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24mm spot size, the largest spot found on any hair removal laser. Candela’spatented Dynamic Cooling Devise (DCD) technology protects the upper layers of skin with cooling bursts of cryogen. DCD cooling offers optimal treatment with minimal side effects.| Distributor | Candela |
|---|
| Manufacturer | Candela |
|---|
| Model | GentleMAX Pro |
|---|
| Manufactured Year | 2017 |
|---|
| Specific Equipment Type | Dual Wavelength Laser |
|---|
| Sale Price | 12500 |
|---|
| Treatments Performed | Hair Removal, Vascular, Pigmentation
Skin Rejuvenation
Skin Tightening |
|---|
| Handpieces | Standard Handpiece DCD 12-18mm , Large Spot Size Handpiece DCD 22-24mm |
|---|
| Shot Counts | None |
|---|
| Wavelengths | 755nm
1064nm |
|---|
| Consumables used by device | Windows, Distance Gauges |
|---|
| Consumables with purchase | 3 x Operator goggles, 1 x patient goggles, distance gauges, windows |
|---|
| Annual Service Price | Servicing available through Candela |
|---|
| Service Contract Price | $11,000 per annum |
|---|
| Additional Information | Any additional information can be sent on request |
|---|
| |
|---|
Treatments:2017 Candela GentleMAX Pro Device Details- Hair Removal
- Beard Bumps
- Facial Lesions
- Fine Lines and Wrinkles
- Leg Veins
- Skin Tightening
- Vascular Lesions
- Warts
- Skin Rejuvenation
- Hemangiomas
- Birthmarks
- Freckles
- Melasma
- Mevus of Ota
- Pigmented Lesions
- Sun / Age Spots
The Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24 mm spot size, the largest spot found on any hair removal laser.Fast – With 24 mm spot size and repetition rates up to 2 Hz, the The Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24 mm spot size, the largest spot found on any hair removal laser. It has two wavelengths, the 755 Alexandrite and the 1064 ND:yag, allowing you to offer many treatment options.Candela’s patented Dynamic Cooling Devise (DCD) technology protects the upper layers of skin with cooling bursts of cryogen. DCD cooling offers optimal treatment with minimal side effects. offers fast treatment times with it’s spot size.Powerful – 26,333 watts peak power, capable of delivering fluences up to 100 J/cm² for vascular applications, and hair removal energy in pulse duration as short as 3 ms for unparalleled treatment efficacies.Treats all skin types – Deep penetration with minimal scattering of laser energy makes the GentleMax Pro ideal for all skin types, particularly dark and tanned skin.Versatile – Non-ablative treatment, including fine lines and wrinkles, and for pseudofolliculitis barbae (PFB), or beard bumps, leg and facial veins.Patented Epidermal Cooling – Candela’s Dynamic Cooling Device represents an adjustable epidermal protection technology to maximize patient safety and comfort.Date of Manufacture – 2017Accessories Included with Purchase – Specialty 1.5, 3mm, 3x10mm Handpiece, 6, 8, 10, 12, 15, 18mm Handpiece, Full Set of Distance Gauges, Distance Gauge Case, Patient Eyewear, Treatment Goggles, Foot Pedal, Fiber Pole, System Key, System Interlock Key, Treatment Guidelines, and User Manual. | Cutera Enlighten III Pico-Nano Second Tattoo RemovalThis next-generation PicoGenesis laser is an advanced, non-thermal way to treat pigmentary concerns, PicoGenesis harnesses a non-thermal, photomechanical effect paired with ultra-short—one trillionth of a second long—pulse durations. The perfect blend of technologies creates shockwaves that shatter pigments in the skin without damaging the surrounding tissue, while inducing dermal disruption and remodelling for true skin revitalisation.Unlike conventional laser toning that requires up to 15 treatment sessions and often lead to adverse side effects such as redness, swelling and itching. Thanks to the incorporated picosecond technology, in as few as three sessions you will experience a dramatic improvement in the reduction of pigmentation as well as a brighter, more uniform complexion in just 20 minutes—and all with no downtime! With entirely changeable parameters, this game-changing treatment an be used to benefit even the most challenging skin concerns, and can also effectively remove all colours of tattoos.Recommended for all skin types, the PicoGenesis laser procedure is used to treat : Cutera Enlighten III Pico-Nano Second Tattoo Removal• Brown spots
• Sun damage
• Age spots
• Melasma
• Hyperpigmenation
• Pigmented lesionsenlighten III combines multiple wavelengths (1064 nm, 532 nm and 670 nm) and picosecond + nanosecond pulse durations (750/660 ps + 2 ns) in a single platform for the treatment of unwanted multicolor tattoos, epidermal and dermal pigment, and skin revitalization across all skin types. Unlike conventional laser toning that require up to 15 treatment sessions and often lead to unpredictable results, PICO Genesis harnesses the power and flexibility of enlighten SR combined with its technical benefits in a dual delivery procedure to selectively shatter pigment and induce dermal disruption and remodeling for true skin revitalization in fewer than 3 sessions.“The enlighten laser system has been a game changer for my tattoo removal practice. I feel much more confident that we can deliver patients the results they have been wanting since laser tattoo removal was first invented.” | Fotona XP Spectro Laser GeneratorThe Fotona XP Spectro laser offers an industry leading number of treatments from its advanced platform. The Fotona XP Spectro is an ideal choice for new clinics and clinics wishing to advance to a Fotona laser system from their current equipment.Not looking for a new Laser? See our Used-Laser Sales DirectoryThe Fotona XP Spectro laser offers high quality, fast, efficient treatments in the fields of aesthetics and surgery without compromising efficacy.The Fotona XP Spectro laser system has a 35 watt Nd:YAG engine offering different pulse configurations to be able to offer a wide range of applications at no extra cost and no need for additional hand pieces of software.Non-ablative Nd:YAG lasers are a extremely popular choice of laser in an extremely lucrative marketplace. Nd:YAG is proven as a gold standard in hair removal, skin rejuvenation, vascular treatments and much more. Fotona Xp Spectro Nd:YAG laser emits laser energy at 106nm which is proven to minimize discomfort while showing exceptional efficiently and long term results Features:Fotona XP Spectro Laser Generator
* Highest Performance
* Gold standard ND:YAG lasers
* Optional QCW Nd:YG laser
* Multiple applications
* Advanced scanner for greater Precision, Speed and Efficacy
* FRAC3 modality
* User friendly
* Massive earning potential
* Ability to treat all skin types safely and effectively Key Treatments:
* Laser Hair removal
* Rosacea treatments
* Fine wines and Wrinkles
* Laser peels
* Acne treatments
* Laser assisted lipolysis
* Laser assisted Hyperhidrosis
* Onychomycosis
* Skin tightening, tonng and texturing
* Endovenous laser
* Vascular legions
* Thread veins
* FRAC3
* Pigmentation
* Verrucae Technical Data:
* Laser wavelength:1064 nm
* Max. average power:35 W
* Pulsewidth range:PULSE: 0.1 to 50 ms, QCW: 0.1 to 2 ms
* Max. frequency:PULSE: 75 Hz, QCW*: 100 Hz
* Manual spotsizes:2 to 10 mm
* Scanner spotsizes:3 mm*, 6 mm, 9 mm*
* Scanner area:42 cm²
* Beam delivery type:Optical fiber Comes with:
* 5 Years Full Parts and Labour Warranty
* 3 pairs of laser safety goggles
* Standard Nd:YAG hanpiece (R33)
* Training and ongoing support
* Competative rates for clinic consumables | Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
The Laser uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IOptima-518-Classic Active Optical Systems Optima 518 IPL LaserThe Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. | Fotona XS Dynamis Pro Multi-Application LaserOVERVIEWTechnology for Next Generation Resurfacing
With advanced treatment attributes and fully customizable settings, Fotona’s XS Dynamis offers true 3rd generation Er:YAG laser skin resurfacing. The XS Dynamis represents a complete rejuvenation solution. Its functions range from superficial to deep peels, from non-ablative to fully ablative and from full-field to fractional resurfacing. Resurfacing has Never Been as VersatileWith the XS Dynamis you can be your own artist; reverse the effects of aging and give skin a healthy, young look and feel. Over 20 treatment pre-sets can be accessed and further fine-tuned using digital ablation and coagulation depth indicators to gain predictable outcomes – one of the system’s strongest points. Complete ablation and coagulation control enables treatments to be tailored to each specific skin condition to achieve perfect results in both full-field and fractional resurfacing. The XS Dynamis can even be used with laser scar revision treatments. Acne scars in particular respond well to gentle Er:YAG laser resurfacing. Perfect for Pigmented Lesions Fotona XS Dynamis Pro Multi-Application LaserIn addition to skin resurfacing, the XS Dynamis’ high-performance Er:YAG laser is well equipped to handle a range of other applications in aesthetics and dermatology. The XS Dynamis can safely and effectively remove pigmented lesions like keratoses and moles through gentle ablation of the epidermis and superficial dermis in a controlled and relatively bloodless manner. Clinical studies have shown that Er:YAG lasers are very effective for the treatment of keratoses, with a clinical and histological improvement of up to 93% after just a single treatment. A Star Performer in GynecologyFotona’s Er:YAG laser wavelength is also highly useful for the treatment of lesions of the uterine neck and vagina, as well as HPV lesions, pigmentations and neoplasias. The XS Dynamis offers many benefits in gynecological treatments, including non-invasive, high-precision procedures with little or no pain, and often without anesthesia. Because of its non-contact, sterilizing capability it can even be used on infected tissue, with total re-epithelization and fast wound healing. |
Reviews
There are no reviews yet.