| Description | For women’s health.
Perform minimally invasive, non-hormonal, energy-based gynecological health treatments – in your office, in as little as 10 minutes.Minimize physician fatigue with articulated arm and featherweight handpieces
Gynecology-specific selection of handpieces and lenses
Intuitive touch-screen interface stores and recalls user preferences
Precision internal scanner digitally synchronized with laser pulse generator
Compact, quiet, easily mobile, and portable | Compression of the skin rotates follicle closer to the surface, blenches blood vessels and reduces competing chromophores. High fluence enables treatment of areas requiring precision and thin, light hair. | Laser Hair Removal
Details:- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| Includes:
1 Fractional Scanner Handpiece for Ablative Skin Resurfacing
1 Incisional Handpiece with up to or less than .2mm Spot Size
Handpiece Case
Distance Gauges
Footswitch
Patient Eyewear
Operator Eyewear
Operator Manual
Warning Sign | Thanks to the unique technologies behind Legend Pro, patients experience minimal pain and downtime during and after treatment, without the need of numbing cream before the treatment. The desired results are promptly visible. Indications include: skin resurfacing and treatment of mild to moderate wrinkles and rhytids. | The HydraFacial resurfacing procedure thoroughly cares for your skin, providing cleansing, exfoliation, extractions, and hydration, including Vortex-Fusion of antioxidants, peptides, and hyaluronic acid. The HydraFacial is a non-invasive, non-surgical procedure that delivers instant results with no discomfort or downtime. The procedure is immediately effective |
| Content | Syneron Candela CO2RE Intima Laser
Laser Type:CO2
Wavelength:10,600nm
Laser Emission Mode:Pulsed
Output Power:60 watts (maximum peak)
Laser Beam Energy:Variable from 1 – 90 mJ
Pulse Repetition Rate:Up to 16.7 kHz
Pulse Duration:20 – 3000 usec
Power Stability:± 1.5 watts (±5%)
Mode Quality:(M²) < 1.2
Beam Size:Ø 1.8 ± 0.5 mm
Beam Divergence:7.5 ± 0.5 mrad (full angle)
Polarization:> 100:1 linear (orthogonal to mounting pads)
Maximum Scan Area:10 mm diameter
Aiming Laser:5 mW, 650 nm (red) diode laser
Articulated Arm:Lightweight, aluminum fiber, 7-joint, pneumatically balanced
Treatment radius at full arm extension:85 cm (33.5″)
Horizontal rotation:360°
Lens Assemblies:150 um spot size, 120 um spot size:(optional)
Handpiece:Multi-use Aesthetic or surgical hand piece
User Interface:10.4″ high-resolution
Laser Emission Control:Footswitch
Laser Emission Indicators:Solid amber LED in Standby and Ready modes
Flashing:red LED during laser emission
Electrical Requirements:100 – 240 VAC self-sensing, 50/60 Hz, 7.1 A, single phase
Dimensions:40 cm x 44 cm x 177 cm, (15.75″ x 17.3″ x 70″)
Weight:26 kg (58 lbs)
Operating Modes
Mode:[ Energy Settings ] [ Fractional Coverage ] [ Estimated Ablation Depth ]
CO2RE Light:[18 – 74.5 mJ] [30 – 50%] [20 – 40 um]
CO2RE Mid:[45 – 257 mJ] [20 – 40%] [100 – 200 um]
CO2RE Deep:[30 – 70 mJ] [1 – 5%] [500 – 750 um]
CO2RE Fusion:[45 – 128 mJ, 30 – 70 mJ] [20 – 40%] [100 – 200 μm & 500 – 750 um]
Classic Resurfacing:[1 – 10 mJ] [Full] [100 – 200 um]
Dermal Excision:[5 – 40 mJ] [N/A] [0.2 mm x selected line 0.2 mm freehand]First fully integrated CO2 laser, worldwide.
Designed to adapt to your patients needs, with 100+ indications.What CO2RE Is For100+ indications cleared in 10 medical specialties, including dermatology, plastic surgery, and gynecology.Imagine having one system designed for numerous procedures that require excision, incision, ablation, coagulation, and resurfacing of soft tissue. Its here. With the CO2RE system, you can precisely target and efficiently treat the skin with control.Treat multiple skin layers in one pass
Perform full and fractional resurfacing
Enhance coagulation
Encourage neocollagenisIndustry-first internal scanner optimized for numerous individualized treatment applicationsKey Benefits of the CO2RE System
Give your patients positive experiences and outcomes.
CO2RE treatments are fast and require limited downtime.The system delivers proven, predictable, visible results across indications1-4, including:Enhancing skin tone and texture through skin resurfacingReducing the effects of the sun and aging on the skinSmoothing out fine lines, wrinkles, and surgical and acne scarsGain unparalleled treatment flexibility that can help your practice grow.
Designed from the inside out to be a comprehensive work station:
CO2RE Aesthetics for skin resurfacing, from superficial to deep skin treatments, including several options and combinations tailored for your patients needs.
CO2RE Surgical for a true, continuous wave with efficient skin coagulation after the surgical cut.
CO2RE® Intima for gynecology applications, enabling you to broaden your portfolio offering.CO2RE Product FeaturesLightLight Peel
20-40 µm
Level with Stratum ComeumMidEpidermal and dermal resurfacing
Coagulation
100-200 µm
Improve skin tone and texture
Complexion refresherDeepDeep fractional resurfacing
Deeper level coagulation
500-700 µm
Improve scars, fine lines and wrinklesFusion Syneron Candela CO2RE Intima LaserCombination of superficial and deep fractional resurfacing
Superficial texture variations
Fine lines and wrinklesWhat CO2RE Intima is For
The CO2RE® Intima system is uniquely engineered to transform treatment of many dermatological conditions, including gynecological needs.
The CO2RE Intimas comprehensive range of treatment options1 include:Using well-established CO2 technology, you can now perform minimally invasive, non-hormonal, energy-based treatments of the introitus, vaginal canal, and external genitalia in your office, in as little as 10 minutes for each treatment.Ablation and resurfacing of soft tissue
Scar tissue (e.g. C-section scar)
Conization of the cervix such as vulvar and vaginal intraepithelial neoplasia (VIN, VAIN)
Leukoplakia (vulvar dystrophies)
Condyloma acuminateThe systems customized handpieces are designed to treat the introitus, vaginal canal, and external genitalia.
Conveniently treat with pre-set or individualized treatment options
Accurately target and treat tissue with ergonomic, pen-like precision2
With 360o rotation capability for ease of use on tissue along the vaginal canal, and sterile for every patient, the single-use handpieces are guaranteed ready to use.Significant benefits for your practice and patients.
Efficient procedural time as little as 10 minutes for each treatment
Minimally invasive, non-hormonal, energy-based treatment
Portable system allows you to easily perform office-based procedures, and is easy to move from room to room
Simple in-office setup for gynecological applications
Single-use handpiece optimizes workflow, enhancing patient safety
Financial savings single-use handpieces reduce staff time, administrative costs, and inefficienciesDesigned with your practice in mind.
The CO2RE Intima system offers numerous user-friendly, productivity-enhancing features.Minimize physician fatigue with articulated arm and featherweight handpieces
Gynecology-specific selection of handpieces and lenses
Intuitive touch-screen interface stores and recalls user preferences
Precision internal scanner digitally synchronized with laser pulse generator
Compact, quiet, easily mobile, and portableWell-established CO2 technology treats skin or soft tissue.
CO2 technology has been used in gynecology for benign and pre-malignant vulvar and cervical dysplasia since 1973.The CO2RE system offers customizable treatment capability with handpiece and lens combinations to provide physician control. Compared to traditional surgical methods, it provides greater precision, cleaner incision, and less scarring. | 2017 Lumenis Lightsheer Desire
2017 Lumenis Lightsheer Desire W/ Both HS Handpiece & XC Handpiece. The system only had 1 previous owner and is in great working condition. The system can do Permanent hair Reduction, Vascular Lesions, Angiomas, Hemangiomas, Telangiectasias, Leg Veins, and Pigmented Lesions. Equipment also includes Power Cord, Interlock, and Stand.Med Laser Outlet- Medical Device SupplierWe provide quality Pre-owned equipment in the Aesthetic Medicine arena. Why pay outrageous prices for a New device when you can get Pre-owned for up to 50% savings. We are not affiliated with the manufacturer.Lumenis Lightsheer Desire Hair ReductionThe technology behind the DESIREGreat clinical results begin with the LightSheer DESIRE 805 nm diode laser empowered by two advanced technologies:Lumenis Lightsheer Desire Hair Reduction Vacuum Assisted High-Speed Integrated Technology A large 22×35 mm spot size enables the use of low-fluence and with a unique mechanism for pain reduction provides effective, fast and comfortable treatment.ChillTip Technology Integrated contact cooling provides epidermal protection for treatment areas requiring precision and higher fluence.How Vacuum Assisted Technology Works– Vacuum gently draws skin into the handpiece, skin is stretched thin and target is pulled closer to the energy source.– Energy is applied to target in which melanocytes are spread apart and blood flow is constricted.– Target is damaged and skin is released.Lumenis Lightsheer Desire Hair Reduction Advantages of High-Speed Vacuum Assisted Technology– Efficacy: reduction in competing chromophores enables delivery of laser energy more efficiently.– Safety: less energy is absorbed by the epidermis and lower fluence is required since the target is closer to the energy source.– Decreased pain: The unique vacuum mechanism activates tactile and pressure skin receptors to inhibit the transmission of pain sensation.Lumenis Lightsheer Desire Hair Reduction How ChillTip Works– Skin is cooled before and during treatment.– Skin is compressed. Laser beam applied to skin and target is damagedAdvantages of ChillTip Technology– Safety: superior epidermal protection is achieved through ChillTip contact cooling– Patient comfort: by continuously cooling the skin, pain and discomfort are significantly reduced.– Efficacy: Compression of the skin rotates follicle closer to the surface, blenches blood vessels and reduces competing chromophores. High fluence enables treatment of areas requiring precision and thin, light hair. | 2019 Lumenis Splendor X- Laser Hair Removal
Lumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthThe Lumenis Splendor X has been introduced to be a player in the solid state Nd:YAG and Alexandrite laser hair removal market. The gold standard for hair removal has always been considered Alexandrite 755nm for light skins and Nd:YAG 1064nm for dark skins.The Lumenis Splendor X combines both in a unique way with blended emission.Instead of firing a single wavelength at a time the Splendor X allows you to fire both wavelengths simultaneous in adjustable amounts to suit the skin type and hair types. This means you are target multiple chromophores at any given time given enhanced results across the board.The Lumenis Splendor X also allows the user to choose between square and round spot sizes with large spot sizesLumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthLaser Hair Removal
Details:2019 Lumenis Splendor X- Laser Hair Removal- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| EMVERA CLARO2 CO2 LASER
Claro2 Medical Laser System
The Claro2 laser technology offers the most innovative approach to laser treatments today. It provides an acceptable and comfortable procedure under little or no anesthesia with minimum pain from evaporation of the skin layers, resulting in minimal social or work downtime. The laser delivers a series of microscopic, closely-spaced laser spots to the skin while simultaneously preserving the normal, healthy skin. The undamaged skin becomes a reservoir of tissue for fast heating and regeneration of the treated area by producing and providing new dermal collagen and eliminating epidermal pigmentation and irregularities to the skin tone. The Claro2 laser system is specially designed to improve skin texture and tone, and fight wrinkles, scars and pigmentations. Since the treatment procedures are customized to patients skin, operators are able to adjust laser settings to tailor treatments and achieve superior results.Claro2 Laser Features Provide:
Unparalleled char-free ablation, vaporization, excision, or incision of soft tissues
Reduced thermal damage to surrounding tissues
Rapid healing and minimal downtime
Stimulation of deeper collagen with high pulse energy
Large TFT LCD touch screen provides easy operation with the latest high speed microprocessor technology
Adjustable scanning patterns and sizes
Adjustable intensity of pilot beam
Adjustable pulse duration
Last treatment setting memorization
Automatic alarm system for operation and errors
No consumable costsIncludes:
1 Fractional Scanner Handpiece for Ablative Skin Resurfacing
1 Incisional Handpiece with up to or less than .2mm Spot Size
Handpiece Case
Distance Gauges
Footswitch
Patient Eyewear
Operator Eyewear
Operator Manual
Warning SignLaser Type:Sealed of Co2 Laser
Wavelength:10.6 um
Mode Structure:TEM00
Max Power:0-30W (adjustable)
Spot Size:Equal to or less than .2mm
Aiming Beam:630nm Red Laser (Adjustable Brightness)
Delivery System:Articulated Arm
Operation Modes:Continuous Wave, Single Pulse, Repetition Pulse, Super Pulse, Scanner
Pulse Width:Single Pulse (0.01-1s); Repetition Pulse (0.001-1s); Scanner (0.0001-0.01s)
Scan Size: Adjustable
Scan Pattern:Oval, Triangle, Rectangle, Line
Scan Array Density:Adjustable
Cooling System:Self-Contained, Closed Cycle
Power Supply:100-120V AC, 50/60Hz or 200-240V AC, 50/60Hz
Environment Temperature:10-40 Degrees Celsius
Relative Humidity:Below 80%
Dimensions:561mm x 500mm x 1443mm
Weight:42kgApplications Include:EMVERA CLARO2 CO2 LASERDermatology, Plastic Surgery and General Surgery procedures including but not limited to:
Laser skin resurfacing
Treatment of furrows and wrinkles
Removal of skin tags, actinic keratosis, acne scars, keloids, tattoos, telangiectasia, squamous and basel cell carcinoma, warts and uneven pigmentation
Treatment of cysts, abscesses, hemorrhoids and other soft tissue applications
Blepharoplasty
Site preparation for hair transplantsOtorhinolaryngology (ENT) procedures including but not limited to:
Treatment of leukoplakia of larynx, nasal obstruction, rhinophyma, verrucrea vulgares, choanal atresia, rhinophyma, LAUP and papillomatosis polypsGynecology:
Treatment of condyloma acuminate, cervical
intraepithelial neoplasia, leukoplakia and vulvar/
vaginal intraepithelial neoplasia, cervical dysplasia
Podiatry procedures including but not limited to:
Ablation, vaporization and excision of soft
tissue lesions such as ingrown nail, fungal nail,
porokcratoma, matrixectomy and verrucae vulgares | Lumenis Pollogen Legend Pro 2020
Activating the body’s natural healing processes by applying RF-assisted ultra-thin electrodes to thermally ablate the epidermis, creating micro channels to induce controlled micro wounds, thus encouraging the generation of new and healthy skin.TriFractionalApplying contact RF and pin point ablation with controlled volumetric heating to achieve skin resurfacing and regeneration via wound healing process, resulting in skin texture improvement and refinement.M² unique synergized treatment combines the macro volumetric heating of tissue with TriPollar RF and the precise micro heating of focal points with VoluDerm RF assisted ultra-thin electrodes. Treatments with M² reaches multiple layers of the skin introducing a wide range of solutions for skin resurfacing and inducing regeneration as well as wrinkle reduction.Thanks to the unique technologies behind , patients experience minimal pain and downtime during and after treatment, without the need of numbing cream before the treatment. The desired results are promptly visible. Indications include: skin resurfacing and treatment of mild to moderate wrinkles and rhytids.IS AN ADVANCED MEDICAL AESTHETIC PLATFORM INCORPORATING THE LEADING INDUSTRY TECHNOLOGIES – HYBRID ENERGY TECHNOLOGY, TRILIPO USING NON-INVASIVE TRIPOLLAR RF ENERGY, AND DYNAMIC MUSCLE ACTIVATION. THE COMBINATION OF THESE TECHNOLOGIES PROVIDES EFFECTIVE DERMAL VOLUMIZING, SKIN TIGHTENING, AND BODY SCULPTING.Lumenis Pollogen Legend Pro Laser device is effective and fast with minimal discomfort. It is suitable for all skin types and ethnicities and carried out in a simple ‘walk-in walk-out’ treatment with minimal downtime.-Visible results after the 1st treatment-Long-term measurable results-Minimal discomfort, minimal downtime-Easy to use with a fast learning curveLumenis Pollogen Legend Pro Laser system intended for dermatological procedures requiring ablation and resurfacing of the skin when using VoluDerm Energy (Applicator VO). It is also intended for use in dermatologic and general surgical procedures for the non-invasive treatment of mild to moderate facial wrinkles and rhytides when using TriPollar RF Energy (Applicators 1-3)Specification : Lumenis Pollogen Legend Pro 2020Input Voltage:100-2400 Volt,50-60Hz, max 2.2A
Mode of Operation:VoluDerm, TriFractional, Tripollar
Maximum Output Power RF:50 Watts @ 200 Ohm
Maximum Output Voltage:100 Plus or Minus 10 Vrms
Output Frequency RF:1Mhz
Output Power Control RF:Pulse Width Modulation (PWM)
Weight: 66 Kgs
Dimensions:L1.5 x W1.5 x H3.6 Inch
Environmental Conditions for Operation
Temperature:15 Degrees Celsius to +30 Degrees Celsius (59-86 Degrees Farrenheit)
Relative Humidity:Up to 80%; Non- Condensing
Atmospheric Pressure: 70-106 kPa
Maximum Altitude:2000 Meters
Environmental Conditions for Transportation & Storage
Temperature:-20 Degrees Celsius to + 55 Degrees Celsius (-4-131 Degrees Farrenheit)
Relative Humidity:80%; Non-Condensing
Atmospheric Pressure:50-106 kPa
Maximum Altitude:2000 Meters | Edge Systems HydraFacial MD TowerTreatmentThe HydraFacial treatment merges soothing and invigorating spa therapies with advanced medical technology to achieve instant, lasting results. This innovative treatment provides results after just one visit!Skin Health EducationYour skin is the largest organ of your body.Everyday, your skin is exposed to free radicals – unstable molecules like pollution, sun, and stress which damage the vital skin cells like collagen and elastin that keep you looking fresh and young.One of the most damaging free radicals is the sun’s rays. UVA rays have the same strength, every day, all year long.Antioxidants counteract free radical damage by trapping and containing them, preventing further damage to skin cells.The HydraFacial utilizes some of the most powerful antioxidants to revitalize and protect your skin.Skin Health for Life is not just improving your appearance, but actually restoring youthful, healthy skin. Skin health is a lifestyle, requiring monthly maintenance and the right treatment for every skin type. That treatment is the HydraFacial.Works for all skin types- Shows immediate results
- No downtime or discomfort
- Target specific skin concerns
- Provides an alternative to invasive procedures
The process Edge Systems HydraFacial MD TowerStep 1. Cleansing and exfoliation: dead skin cells are removed to revieal healthly new skin.Step 2. Acid peel: this gentle peel helps loosen dirt and debris from pores without irritation.Step 3. Extractions: Painless, automated extractions use vortex suction to clean out pores.Step 4. Hydration: Antioxidants and Hyaluronic Acid are Vortex-Fused™ to nourish and protect.The HydraFacial resurfacing procedure thoroughly cares for your skin, providing cleansing, exfoliation, extractions, and hydration, including Vortex-Fusion of antioxidants, peptides, and hyaluronic acid. The HydraFacial is a non-invasive, non-surgical procedure that delivers instant results with no discomfort or downtime. The procedure is immediately effective |
Reviews
There are no reviews yet.