| Description | Rotor-Gene Q 5plex is a Real-time PCR cycler and High-Resolution Melt analyzer with 5 channels (green, yellow, orange, red, crimson) plus HRM channel, laptop computer, software, accessories: includes 1-year warranty on parts and labor, installation and training not included | The budget friendly LOGIQ P9 – a general imaging system designed for quick diagnostic exploration and full schedules. The LOGIQ P9 enables clinicians to make timely, confident decisions. | 2018 Lutronic Infini RF Microneedling Skin Tightening Laser with RF Microneedling Handpiece - with CONSUMABLE SUPPORT - Free Shipping - | - This Multi-function system offers a wide range of treatments.
- 1046nm long pulsed Nd:Yag treating hair removal, fungal nail and deep thread veins.
- 650nm & 585nm IPL handpieces including for both hair removal, skin rejuvenation, thread veins, pigmentation and more.
- This system can be added to with a 2940 fractional handpiece
- Safety goggles supplied
- Delivery, installation and warranty included.
| Laser Hair Removal
Details:- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| 2015 Active Optical Extra 818 IPL Hair Removal and Skin Rejuvenation; Excellent Cosmetic and Operating Condition, Very Lightly Used for Demonstrations Only, Single Owner; Included Handpieces and Pulse Counts: Hair Removal Handpiece = 6,617 Pulses, Facial Handpiece = 2,190, Life for Each Handpieces is 250,000 Pulses. |
| Content | Rotor-Gene Q 5plex HRM
Each tube spins in a chamber of moving air, keeping all samples at precisely the same temperature during rapid thermal cycling. Detection is similarly uniform. When each tube aligns with the detection optics, the sample is illuminated and the fluorescent signal is rapidly collected from a single, short optical pathway.This thermal and optical uniformity results in sensitive, precise, and fast real-time PCR analysis (see figure “Precise real-time PCR analysis”). It also eliminates sample-to-sample variations and edge effects. These are unavoidable in traditional block-based instruments due to temperature gradients across the block and multiple, complex optical pathways. The rotary design delivers well-to-well variation ±0.02°C Uniform detection eliminating the need for ROX reference dye Fast ramping and negligible equilibration times for short run times Complete confidence in your results!The unrivaled optical range enables multiple applications Whether your essay is based on intercalating dyes such as SYBR Green, probes such as hydrolysis (TaqMan), hybridization (FRET), Scorpion probes, or other multiplex chemistries, the Rotor-Gene Q meets your requirements. With up to 6 channels spanning UV to infrared wavelengths, the cycler delivers the widest optical range currently available (see Table “Channels for optical detection”). In addition, the software allows you to create new excitation/detection wavelength combinations, which means that the Rotor-Gene Q is compatible with dyes you may use in the future.The unique centrifugal design of the Rotor-Gene Q 5plex HRM ensures optimal thermal and optical uniformity between samples, which is critical for precise and reliable analysis . Each tube spins in a chamber of moving air, keeping all samples at precisely the same temperature during rapid thermal cycling. Detection is similarly uniform. When each tube aligns with the detection optics, the sample is illuminated and the fluorescent signal is rapidly collected from a single, short optical pathway. This thermal and optical uniformity results in sensitive, precise, and fast real-time PCR analysis. The rotary design delivers up to 20 times better thermal precision in real-time cycling compared with traditional block-based instruments. Have complete confidence in your real-time PCR test by using highly precise rotary technology. Robust optical range enables multiple applications
With a choice of up to 6 excitation sources and 6 detection filters, combined with a short, fixed optical path, the
Rotor-Gene Q MDx 5plex HRM can be used for multiplex reactions (see table), ensuring minimum fluorescence variability between samples and eliminating the need for calibration and compensation. | Blue | 365 ± 20 | 460 ± 20 | Marina Blue, Edans Bothell Blue, Alexa
Fluor 350, AMCA-X, ATTO 390 | | Green | 470 ± 10 | 510 ± 5 | FAM, SYBR Green I, Fluorescein,
EvaGreen, Alexa Fluor 488 | | Yellow | 530 ± 5 | 557 ± 5 | JOE, VIC, HEX, TET, CAL Fluor
Gold 540, Yakima Yellow | | Orange | 585 ± 5 | 610 ± 5 | ROX, CAL Fluor Red 610, Cy3.5,
Texas Red, Alexa Fluor 568 | | Red | 625 ± 10 | 660 ± 10 | Cy5, Quasar 670, LightCycler
Red640, Alexa Fluor 633 | | Crimson | 680 ± 5 | 712 high pass | Quasar 705, LightCycler Red705,
Alexa Fluor 680 | | HRM | 460 ± 20 | 510 ± 5 | SYBR Green I, SYTO9, LC Green,
LC Green Plus+, EvaGreen |
Minimum maintenance; maximum convenience
The Rotor- Gene Q 5plex HRM is engineered to reduce the need for maintenance and to maximize ease of use. This saves time and costs, and keeps the instrument operational for continuous testing. The outstanding robustness of Rotor-Gene technology is proven in several thousand installations worldwide.Convenient features of the Rotor-Gene Q MDx 5plex HRM include: - Lifetime guarantee on highly stable LEDs, no expensive and time consuming lamp replacement, and no gradual performance loss
- Cost-effective and easy temperature-accuracy verification (see below)
- Optical calibration not required at installation, or when the instrument is moved
- “Plug and play” connectivity between computer and instrument
- No sample block to clean
- No condensation or bubbles in the reaction due to rotation
- Small, light, and robust instrument — simply place it where you want it
Procedure Nucleic acids are purified using the designated manual or automated purification kit that is validated for the downstream assay. After assay setup, the assays are then transferred to the Rotor-Gene Q MDx 5plex HRM for PCR and data analysis. Easy routine verification
Certified laboratories often want to verify thermal accuracy. For most cyclers, this usually requires interaction with a service engineer. With the Rotor-Gene Q MDx 5plex HRM, this is not necessary. Instead, the easy-to-use, cost-effective proprietary Rotor-Disc OTV (Optical Temperature Verification) Kit automates temperature accuracy testing. The full procedure takes less than 30 minutes and can be performed by any user.Applications The Rotor-Gene Q MDx 5plex HRM is intended for in vitro diagnostic use. The Rotor-Gene Q MDx 5plex HRM instrument is intended to be used only in combination with QIAGEN kits indicated for use with Rotor-Gene Q MDx 5plex HRM instruments for applications described in the respective QIAGEN kit handbooks. Software Software enables quantification and enhances data security
The user-friendly software provides simplicity for the routine user, as well as an open platform for the more advanced developer. Standardization in your laboratory is supported by software wizards, templates for run, processing, and analysis procedures, and various pre-defined report formats.Data security, from starting the run to exporting the results, is assured by audit trails, digital signatures, and individual user management. Each Rotor-Gene Q MDx 5plex HRM instrument is supplied with an unlimited software user license for your institute, enabling you to access and analyze your test results on as many computers as you want — in the laboratory or in the office.Features | Specifications | | Altitude | Up to 2000 m (6500 ft) | | Dimensions | Width, 37 cm (14.6 in.); Height, 27.5 cm (10.8 in.); Depth (without cables), 42 cm (16.5 in.); Depth (door open), 56 cm (22 in.) | | Heat dissipation/thermal load | Average, 0.183 kW (632 BTU/hour); Peak, 0.458 kW (1578 BTU/hour) | | Humidity | 10–75% (noncondensing) | | Operating temperature | 18–30°C (64–86°F) | | Optical System | 5 channels plus HRM; Excitation sources: high-energy light-emitting diodes; Detector: photomultiplier; Acquisition time: 4 seconds | | Overvoltage category | II | | Place of operation | For indoor use only | | Pollution level | 2 | | Power | 100–240 V AC, 50–60 Hz, <520 VA (peak); Power consumption 8 VA (standby); Mains supply voltage fluctuations are not to exceed 10% of the nominal supply voltages; F5A 250 V fuse | | Samples per run (throughput) | Tubes 0.2 ml, 36 samples/run; Strip Tubes 0.1 ml (4 tubes), 72 samples/run; Rotor-Disc 72, 72 samples/run; Rotor-Disc 100, 100 samples/run | | Software | Rotor-Gene Q software, supplied on the installation CD provided | | Storage conditions | 15–30°C (59–86°F) in manufacturer’s package; Max. 75% relative humidity (noncondensing); Environmental class 1K2 (IEC 60721-3-1) | | Technology | Real-time PCR cycler | | Thermal performance | Temperature range, 35–99°C (95–210.2°F); Temperature accuracy, ±0.5°C (calibrated using Rotor-Disc OTV procedure); Temperature resolution, ±0.02°C (smallest programmable increment); Temperature uniformity, ±0.02°C | | Transportation conditions | –25°C to 60°C (–13°F to 140°F) in manufacturer’s package; Max. 75% relative humidity (noncondensing); Environmental class 2K2 (IEC 60721-3-2) | | | | Weight | 12 kg (26.5 lb.), standard configuration |
| GE Ultrasound LOGIQ P9
Key Specifications/Special Features:
GE Logiq P9 Review:GE is the largest global ultrasound developer and manufacturer in the world. They design and produce a number of diagnostic ultrasound systems in many global R&D and production sites such as U.S., Japan, Korea, China, and India. The Logiq sereis targets the genral imaging market and has been very successful in the ultrasound market as well as healthcare.
The Logiq P series was created for the economy market, to provide some of the premium features at a lower cost bracket. GE Logiq P7 and P9 are successors of GE Logiq P5 and Logiq P6, two of the best selling GE Logiq systems for last two decades. The GE Logiq P7 and P9 are the latest in the Logiq series, launching in 2016. GE Healthcare shares ultrasound hardware and software with many global production sites so they can keep material cost down and pass the savings to their customers.GE Logiq P9 Ultrasound Features:The LOGIQ P9 is a highly capable ultrasound system that provides excellent image quality and productivity through easy to use tools across a wide range of applications. The LOGIQ P9’s imaging engine delivers crisp images in a mobile, ergonomically designed console. Automation
– 10.4” Touch Panel
– 21.5” Monitor
– Wireless LAN
– CrossXBeam Compound Imaging
– SRIHD Speckle Reduction Imaging
– Coded Harmonic Imaging
– Auto Image Optimization
– Auto IMT
– AutoEF
– Needle Visualization
– B-Flow
– 3D/4D Obstetric Imaging
– Elastography
– Stress Echo
– TVI/TVD Tissue Velocity and Tissue Doppler Imaging
– Virtual Convex for linear and sectoThis ultrasound system from GE Healthcare is a general imaging system designed for quick diagnostic exploration and full schedules.Whether the need is immediate triage or a comprehensive exam, you can rely on the budget friendly LOGIQ P9 system to provide the consistent image quality, comprehensive application coverage, and ease of use that enable clinicians to make timely, confident decisions.- Ergonomic and Adaptable
- Adjust system to fit most user needs and exams
- Multiple USB ports
- Touch control for easy parameter adjustment
- Adjustable monitor
- Front and rear handles
- Four active probe ports
- Gel warmer
- Storage shelf
- Easy to transport
Your trusted companionWhen every patient, every exam and every day are different, you need a constant that will help you gather information, make informed decisions and provide superior patient care. You need GE LOGIQ ultrasound, your trusted companion for confidently navigating daily challenges.
| 2018 Lutronic Infini RF Microneedling Skin Tightening System Type: Bipolar RF (Radiofrequency) Frequency: 1 MHz Total RF Treatment Level: Up to Level 20 (Max. Power 50 W) Operation Mode:Microneedle Fractional RF (MFR) Treatment Duration:10 ms – 1,000 ms Tips: MFR Microneedle electrodes, 0.5 – 3.5 mm (Adjustable depth) SFR: Up to 144 pins Display: Color Touch LCD (Total Shot Count Displayed) Dual Switch: Foot & Finger Switch Weight: 28 kg Dimension: 362 mm (W) x 409 mm (L) x 1713 mm (H) Location: Lower Face Submental, Neck, Forehead, Periorbital Pass: Pass1: 2.25 – 3.5 mm, Pass2: 1.5 – 2.25 mm, Pass3: 1.0 – 1.25 mm Intensity: Low, Medium, High MANUFACTURER NOTES: Infini Radiofrequency Microneedling The LUTRONIC INFINI is the ideal solution to create targeted and robust coagulation zones in aging, sagging skin with pigmentation, wrinkles and laxity. Complete control over treatment depth and energy levels enables a multi-layered targeted approach for truly customized treatments, regardless of patients skin type or tanned skin. Now you can provide the best solution for results your patients demand year round. UNIQUE TECHNOLOGY, AMAZING RESULTS Infinis proven & impressive design delivers enhanced wrinkle reduction through 3-dimensional energy delivery to volumize tissue. RF energy delivered via insulated gold-coated microneedles creates precise and controllable fractionated coagulation zones within a specific layer of dermis. Adjustable depth control allows for customized and reproducible treatments of delicate areas. Infini effectively lowers the risk of PIH in dark skin types and can be safely used on patients with melasma and other types of pigmented lesions. Lutronics patented ComfortFlow technology maximizes comfort and patient satisfaction. INFINI is unique technology that puts you in control of your skin rejuvenation procedure. You control the treatment depth and energy levels to enable a multi-layered approach for customized treatments, regardless of skin type or tan. Now you can provide the best solution that will keep your patients returning and referring you to new patients.
IDEAL FOR:2018 Lutronic Infini RF Microneedling Skin Tightening– Acne Scars
– Skin tightening– Wrinkles and fine lines– Active inflammatory acne– Enlarged pores– Scar treatment– Stretch marks– Hyperhidrosis – Over production of sweat– Excessive sebum (face oil) production | Lynton Lumina IPL HR Laser
2013 Lynton Lumina IPL HR Laser Hair Removal 650nm 585nm 1064 YAG Beauty MachineIn very good condition and full working order
Purchase new in December 2013, so less than a year old
Laser has minimal use total count of 29427 from newPlease click HERE for further information
Included:-
1 x 2013 Lynton Lumina IPL YAG Laser Hair Removal Beauty Machine
1 x Lynton 650 IPL Handpiece in protective storage box – Total Handpiece Shots 21600
1 x Lynton 585 Plus IPL Vascular Handpiece in protective storage box – Total Handpiece Shots 385
1 x Lynton 1064 YAG Laser Vascular Handpiece with 3mm, 6mm, 8mm tips in protective storage box – Total Handpiece Shots 7442
1 x Set of 3 IPL light guides in protective storage boxFor the following treatments
650nm Hair removal
650nm C.F.TMachine can do the following
585nm Vascular Plus
585nm Pigmentation Plus
585nm Photorejuvenation Plus
585nm Acne Plus
The ultimate ‘build as you grow’ laser & IPL machine, offering practitioners the opportunity to dramatically increase and extend their treatment portfolio, without having to purchase numerous devices. British manufactured and listed on the NHS Supply Chain, the LUMINA offers the UK’s most in-demand treatments; hair removal, tattoo removal, anti-ageing and skin resurfacing.Highly versatile, and with numerous revenue capabilities, the Lumina delivers fast and clinically effective treatment results with superior efficacy. As the best-selling multi-function aesthetic machine, the LUMINA has a proven track record of building, growing and establishing clinics as the No.1 in their area.As our flagship machine, and the product of over 20 years expertise in the design, development and manufacture of laser/IPL systems, the LUMINA is specifically designed to be adaptable to address emerging applications. As well as unrivalled laser technology, the LUMINA has a built-in patient database and parameter printer, and benefits from its easy-to-use touchscreen. 1. Intense Pulsed Light (IPL): the perfect combination of hair removal and skin rejuvenation treatments come as standard with the LUMINA system via its 585 & 650 handpieces.Hand-piece
Type Wavelength(s) Maximum
Fluence Treatments Spot Sizes Maximum
rep. rate
585 Intense
Pulsed Light 550 – 1100nm 50J/cm2 Superficial Vascular
Superficial Pigmentation
Active Acne
Skin-rejuvenation 1x1cm
2.5x1cm
5x1cm
1cm circular 1Hz
650 Intense
Pulsed Light 625 – 1100nm 40J/cm2 Hair removal (1 to 5)
Collagen treatment 1x1cm
2.5x1cm
5x1cm
1cm circular 1Hz
650 Advance IPL hand-piece, which has been designed to provide faster results in hair removal of finer, lighter hairs found on the face and navel. The 650 Advance hand-piece has software optimised for the greater power it delivers, allowing experienced practitioners to treat finer and fairer hairs successfully, in skin type 1 to 3 clients in a single or dual pulse mode. | 2019 Lumenis Splendor X- Laser Hair Removal
Lumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthThe Lumenis Splendor X has been introduced to be a player in the solid state Nd:YAG and Alexandrite laser hair removal market. The gold standard for hair removal has always been considered Alexandrite 755nm for light skins and Nd:YAG 1064nm for dark skins.The Lumenis Splendor X combines both in a unique way with blended emission.Instead of firing a single wavelength at a time the Splendor X allows you to fire both wavelengths simultaneous in adjustable amounts to suit the skin type and hair types. This means you are target multiple chromophores at any given time given enhanced results across the board.The Lumenis Splendor X also allows the user to choose between square and round spot sizes with large spot sizesLumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthLaser Hair Removal
Details:2019 Lumenis Splendor X- Laser Hair Removal- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| Active Optical Extra 818 IPL Hair Removal 2015Handpieces:Hair Removal Handpiece and Facial Handpiece
Chilled Tip:Up to 4c
Pulse Interval:0.5~2 Seconds
Output Power:11-31 joule/cm2, upto 4,000W
Cooling System:Revolutionary dual cooling
Control:Intuitive touch screen control
Lamp’s Life Span:250,000 Flashes (Universal), 200,000 Flashes (Facial)
Treatment Area:7.5 cm2 (15*50mm) Universal, 4.5 cm2 (15*30mm) Facial
Wavelength:420-1100 nm
Weight:42Kg (including Stand, if device is not a table top)
Dimensions:44cm x 45cm x 100cm Extra-818Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Vascular (Facial) TreatmentThe Extra – 818 is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features:
* Contemporary touch screen control
* Built-in Patch Test procedure for examining the optimal energy level
* A stunning number of 450,000 flashes in both lamps.The Extra – 818, based on Active’s GEM-PL technology, sets sets a specific Pulse Pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth.
The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.The combination of tested treatment protocols with high end engineering makes the Extra – 818 the perfect device for leading clinics.Revolutionary Cooling System
The Extra – 818 has a dual cooling system, controlled and monitored in order to ensure long lifetime to the lamp and a comfortable treatment to the patient.Competitive cooling systems “freeze” the skin so that during the treatment the skin temperature will rise to a bearable level. However, this “freezing” temperature might limit the results because the follicles will not reach the coagulation temperature. To ensure optimal results Active installed a special Processor that prevents overcooling the skin and maintains a uniform low temperature of the “glass” throughout the treatment. This revolutionary system enables the Extra – 818 to provide best results with optimal patient comfort.Research Program Active Optical Extra 818 IPL Hair Removal 2015
For clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device.
The energy levels in the self setting program can reach 31Jcm2 with high intensity of 4,000W. |
Reviews
There are no reviews yet.