| Description | Retinomax Series, the world’s leading handheld Ref and Refract Keratometer, delivers wide measurement range on par with table type Ref, now boasts greater mobility, stability and accuracy.Current informatical society, eye fatigue, one of the typical modern diseases cause by eye accommodation issue is now easily discover by ACOMOREF2 series during screening basis. Accommodative Micro Fluctuation result will show in graph for easy reading, plus opacity detection function makes ACOMOREF2 the world first All-in-one Refractometer. | The simplicity is another advantage
Energy-saving and auto-sensing feature will surprise you
White & Black colors are available
1. Compact and sleek design with luxurious feel
Simple, and it makes your work environment look great
2. Adjustable LED intensity
(1) Lifetime durability LED lamp
(2) Easy to mark and block even with dark-tinted lenses by brightness control function
3. Auto power-saving mode
(1) Automatic power off after confirming the marking points
(2) Automatic power off and sleep mode after preset time
Adopting high efficiency LED light source which can easily recognize dark-tinted lenses, and adjust brightness.
• Compact design, intuitive graphic, auto power on/off function. | The Huvitz Excelon CPE-4000 Edger is a versatile lens finishing system designed for retail practices. All of the finishing processes—from tracing to edging—are fully optimized with advanced three-dimensional digital technology, enhancing productivity and efficiency.
Beveling, polishing, grooving and safety beveling are completely integrated and easily performed by a touch of a button. In addition, built-in the CPE-4000 features digital pattern layout that allows users to modify shape width, height, and circumference to better manage the fitting challenges posed by rimless and semi-rimless frames. | Laser-Like Precision
- Tactile control with minimal tissue drag
- Surface only thermal effect
- Predictable, char-free layer-by-layer dissection with optimal visualization of tissue planes
- Safe to use near nerves, vessels, and all delicate organs, including the heart | The ZEISS Cirrus HD-OCT 4000 enable examination of the posterior and anterior of the eye at an extremely fine spatial scale, without surgical biopsy or even any contact with the eye. The Cirrus HD-OCT builds on and refines the retinal imaging technology first introduced with the ZEISS Stratus OCT™. HD-OCT stands for “high-definition optical coherence tomography.”Employing the advanced imaging technology of spectral domain optical coherence tomography, Cirrus HD-OCT acquires OCT data about 70 times faster (27,000 vs. 400 A-scans per second) and with better resolution (5 μm vs. ~10 μm axial resolution in tissue), compared to first-generation OCT technology. Cirrus acquires whole cubes of OCT image data, composed of hundreds of line scans, in about the same time as Stratus acquires a six-line scan. You can view these data cubes in three planes, or through three dimensions, giving you access to an extensive amount of retinal image data in one scan. | The iCare IC200 tonometer is designed for professional use in the surgical operation room, the emergency room and also the clinic. It uses the same patented rebound measuring principle found in other iCare tonometers. There is no need for drops, air or specialised skills for its use. The IC200 gives you positional freedom with a new premium design and user interface. It allows measuring whether the patient is sitting, standing, half-sitting or in the supine or lateral recumbent position. |
| Content | Righton BON ACOMOREF 2 K-Model Autoref-Keratometer3 in 1 Function
With combination of Refractometer (Keratometer), Accommodative Micro Fluctuation, Opaque Media (opacity) screening. For even more information view lightning link casino. Reduce of accommodation testing time
Accommodation measurement speed is remarkably improved that can be tested in 49 seconds per eye in SCR (screening) mode. Objectively find the cause of eye fatigue
Patient’s individual AMF (Accommodative Micro Fluctuation) value will be analyzed and from the data, High Frequency Components (1 – 2.3Hz) will be extracted and based on measurement data, chart location, accommodation reaction value and pupil size to formulate FK map (Frequency of Kinetic reaction). ADD Function Righton BON ACOMOREF 2 K-Model Autoref-Keratometer
The ADD function enable a patient’s near point power to be measured objectively by applying accommodative stimulation. And auto AMF can detects if the power gives the patient eye strain or not by color indication. Residual Astigmatism Calculation (Only for K-model)
Residual astigmatism calculation, necessary for CYL contact lenses and CYL IOL prescriptions, is automatically conducted and results printed out (K-Model). Astigmatism corresponding meridian target
Retinomax Series, the world’s leading handheld Ref and Refract Keratometer, delivers wide measurement range on par with table type Ref, now boasts greater mobility, stability and accuracy.Current informatical society, eye fatigue, one of the typical modern diseases cause by eye accommodation issue is now easily discover by ACOMOREF2 series during screening basis. Accommodative Micro Fluctuation result will show in graph for easy reading, plus opacity detection function makes ACOMOREF2 the world first All-in-one Refractometer. | Huvitz HMB8000 Manual Blocker
The HMB-8000 manual blocker is part of the Huvitz KAIZER series. Kaizer is the next generation to follow the Huvitz Excelon series and is designed with a wide array of features intended to simplify and perfect in-house lens finishing.The KAIZER series is truly a system like no other featuring top-of-the-line technology and unsurpassed performance. When you select the HMB-8000, you will enjoy a lifetime of LED durability. The integrated brightness control function makes it easy to mark and block any lens—even those with dark tint. The HMB-8000 blocking system is also easy to use and features intuitive graphics with outstanding functionality. With its sleek, compact design and luxurious feel, the HBM-8000 is an outstanding component of the KAIZER series.Features of the HMB-8000 Blocker
▪ Compatible with High-End Finishing Systems
▪ Adjustable LED Intensity
▪ Small Footprint
▪ Easy-to-Use
▪ Energy Efficient
▪ VersatilityKAIZER Compatible
The HMB-8000 manual blocker is part of the Huvitz KAIZER series. Kaizer is the next generation to follow the Huvitz Excelon series and is designed with a wide array of features intended to simplify and perfect in-house lens finishing. The KAIZER series is truly a system like no other featuring top-of-the-line technology and unsurpassed performance.The Huvitz HAB-8000 is a one-stop solution, combining the functions of a tracer, lensmeter, and blocker in one powerful machine. Simply place the lens in position and the HAB-8000 will do the rest. The HAB-8000 is user-friendly enough for in-office use as well as robust enough for higher-volume settings. In fact, with the HAB-8000 you can process up to four jobs at the same time while connecting to up two separate edgers and a drill unit. The possibilities are endless. A 10.4-inch high-resolution touch screen monitor allows operators to control all of the system's functions. Featuring Automatic Lens Center Recognition, the HAB-8000 automatically detects the lens shape and knows what type of lens you’re using. The integrated high-performance lensmeter automatically recognizes the lens as it is set in position. Whether it’s a progressive, bi-focal, or other lens, there’s no need for marking with the HAB-8000. In addition, this high-end Huvitz model offers Digital Scan Hole Detection, Advanced 3D Tracing, Drag-and-Drop Hole Editing, Real-Time Data Transmission and so much more. Fully automated lens centering and blocking is now available at the push of a button. | HUVITZ CPE 4000 3D Edger Patternless EdgerFeatures of the CPE-4000 Patternless Edger| ▪ Digital Pattern Layout
▪ Frame Comparison
▪ Advanced Digital Technology
▪ Four Grinding Wheels
▪ 3D Lens Measurement
▪ Ultra-Fine Bevel Adjustment | ▪ Automatic Polishing
▪ Safety Bevel
▪ Adjustable Precision Grooving
▪ Convenient User Interface
▪ More Efficient
▪ Silent Operation |
| |  | | Digital Pattern Layout
The Digital Pattern Layout function allows users to modify lens width, height, and circumference and manage the fitting challenges posed by rimless and semi-rimless frames. You can can choose between optical and geometric centered layouts. Layouts for far vision and near vision in bifocal lens mode are provided. The horizontal PD can be easily adjusted and multiple input methods for setting the height of multifocal progressive lenses are available. | | HUVITZ CPE 4000 3D Edger Patternless Edger | | Frame Comparison
When replacing frames the sizes of the old and new frames can be conveniently compared on screen. Advanced Digital Technology
Advanced 3-Dimensional digital technology substantially reduces the overall cycle time.Four Grinding Wheels
The CPE-4000 edger features four grinding wheels, enabling you to work with all lens materials including glass, plastic, hi-index, polycarbonate, and Trivex. | |  | | 3D Lens Measurement
The CPE-4000 features an advanced lens sensor that will allow you to achieve a 3-dimensional measurement to optimize both beveling and grooving. | |  | | Ultra-Fine Bevel Adjustment
With the CPE-4000, bevel position can be precisely adjusted in fine 0.01mm increments relative to the front curve, back curve, thickness, or base curve of the lens. | | | Automatic Polishing
Enjoy superior, automatic polishing of beveled, grooved, and flat-edged lenses. | |  | | Safety Bevel
The CPE-4000 can achieve front and rear safety beveling, making it a leader in its class. | | | Adjustable Precision Grooving
This model features incredibly fine, adjustable precision grooving. The position, width and depth of the groove can be adjusted in 0.01mm increments. | |  | | Convenient User Interface
A graphic user interface makes it easy for virtually any operator to manage all of the process functions and custom settings. | | | More Efficient
Numeric keypad permits rapid data entry. With the CPE-4000, you can manage multiple jobs simultaneously for improved efficiency. Silent Operation
A built-in inverter mechanism minimizes noise during the edging process, ensuring a comfortable work environment. |
| Edging System | Automatic | | | | Edging Mode | Beveling
Flat Edging
Grooving
Safety Beveling
Polishing | | | | Lens | Glass, Plastic, High Index Plastic, Poly Carbonate, Trivex | | | | Edging Size | Max: 3.54in / 90mm
Min: 0.71in / 18mm | | | | Weight | 99lb / 45kg | | | | Power Supply | AC 110/220V, 50/60Hz | | | | Power Consumption | 1200W (Max) | | | | Dimension | 22.44(W) X 21.26(D) X 18.11(H)in (570(W) X 540(D) X 460(H)mm) | | | | Others | High Brightness Wide TFT LCD Adopted
Bar Code System Available
Networking System | | | | Tracer | | | | Dimension | 11.02(W) X 11.81(D) X 9.05(H)mm (280(W) X 300(D) X 230(H)mm) | | | | Tracing System | 3D Binocular | | | | Weight | 17.6lb / 8kg | | | | Power Supply | AC 110/220V, 50 / 60Hz | | | | Power Consumption | 42W (Max) | | | | Others | User friendly display with LCD |
| Domain Surgical FMX and FMwand Ferromagnetic Surgical SystemThe FMX Generator intelligently delivers electrical energy to the surgical instruments. The advanced generator features a patented software control algorithm that continuously monitors and adjusts the delivery of energy, ensuring that the optimal amount of heat is delivered to the tissue at all times. The large touchscreen display provides the entire surgical team immediate feedback on power setting levels and changing settings is as easy as touching the display. The FMX Generator has earned the Type CF (“Cardiac Floating”) rating.Laser-Like Precision
- Tactile control with minimal tissue drag
- Surface only thermal effect
- Predictable, char-free layer-by-layer dissection with optimal visualization of tissue planes
- Safe to use near nerves, vessels, and all delicate organs, including the heartMinimal Thermal Injury
- As little as 1/10th the thermal injury of monopolar electrosurgery
- As few as 80 microns (0.08 mm) of thermal spread
- Clear margins for reliable pathology specimens
- Surgeons note less unintended damage to tissue, leading to reduced use of blood products during surgery, and less post-operative edema and drainageElectrical Silence
- No electrical current passes through tissue
- No grounding pad
- No spark, arcing, or stray currentPrepare the FMwand by following these simple steps:
- Plug the FMX Power Module into the front panel of the FMX Generator
- Snap the power module into the back of the FMwand Handpiece
- Set the power settings on the generator and the FMwand is readyFMX Generator Technical Specifications Domain Surgical FMX and FMwand Ferromagnetic
- Operating Environment Conditions
Temp: 10° to 30° C (50° to 86° F)
Humidity: 15% to 85% Non-condensing
- Storage Conditions
Temp: -20° to 65° C (-4° to 149° F)
Humidity: 15% to 85% Non-condensing
- Shipping Conditions
Temp: -20° to 65° C (-4° to 149° F)
Humidity: 15% to 85% Non-condensing
- Moisture Protection
Generator: IPX1
Foot Pedal: IPX7 minimum
- Generator Dimensions : 14″ x 4″ x 12″ 35.6 cm x 10.2 cm x 30.5 cm
- Generator Weight : Approximately 20 lbs. (9 kg)
- Power Requirements
Voltage: 110/220/230 Vac
Current: 4/2A rms max
Frequency: 50/60 Hz
- Power Output : 60W Max
- Fuses
For 110V: T 5A L 250V
For 220V/230V: T 2.5A L 250V
- Operating Frequency : 40.68 MHz
- Mode of Operation : Intermittent Operation 10 sec. ON, 30 sec. OFF
- Protection Class : Class I
- Output Type : Type CF | ZEISS Cirrus HD OCT 4000 Quad Core OCT
The ZEISS Cirrus HD-OCT 4000 (Cirrus HD-OCT or Cirrus) enable examination of the posterior and anterior of the eye at an extremely fine spatial scale, without surgical biopsy or even any contact with the eye. The Cirrus HD-OCT builds on and refines the retinal imaging technology first introduced with the ZEISS Stratus OCT™. HD-OCT stands for “high-definition optical coherence tomography.”Employing the advanced imaging technology of spectral domain optical coherence tomography, Cirrus HD-OCT acquires OCT data about 70 times faster (27,000 vs. 400 A-scans per second) and with better resolution (5 μm vs. ~10 μm axial resolution in tissue), compared to first-generation OCT technology. Cirrus acquires whole cubes of OCT image data, composed of hundreds of line scans, in about the same time as Stratus acquires a six-line scan. You can view these data cubes in three planes, or through three dimensions, giving you access to an extensive amount of retinal image data in one scan.Intended UseThe Cirrus HD-OCT with Retinal Nerve Fiber Layer (RNFL), Macular, Optic Nerve Head, and Ganglion Cell Normative Databases is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures.Indications for UseThe Cirrus HD-OCT is a non-contact, high resolution tomographic and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures, including cornea, retina, retinal nerve fiber layer, ganglion cell plus inner plexiform layer, macula, and optic nerve head. The Cirrus normative databases are quantitative tools for the comparison of retinal nerve fiber layer thickness, macular thickness, ganglion cell plus inner plexiform layer thickness, and optic nerve head measurements to a database of normal subjects. The Cirrus HD-OCT is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration, and glaucoma.Note: The Cirrus HD-OCT is not intended to be used as the sole diagnostic for disease.Essential Performance ZEISS Cirrus HD OCT 4000 Quad Core OCTThe Essential Performance of the instrument is to provide accurate measurements of anterior and posterior ocular structure.Patient PopulationThe Cirrus HD-OCT may be used on all adults in need of diagnostic evaluation of the eye. This includes (but is not limited to) patients with the following disabilities or challenges:• Wheelchair user
• Very low or not measurable visual acuity
• Fixation problems
• Postural problems
• Deafness
• Large body, but not those above 99th percentile based on anthropomorphic dataThere is a general requirement that the patient be able to sit upright and be able to place their face in the chin and forehead rest of the instrument (with or without supplemental human or mechanical support).Cirrus HD-OCT is designed for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures. | Icare ic200 TonometerThe device is based on a rebound measuring principle that requires no drops, air or specialized skills for its use. The new premium design and user interface bring IOP measuring to a new level. The Icare ic200 tonometer is designed for professional use in the surgical operation room and emergency room as well as the clinic. The ic200 is fully portable, requires no anesthesia and its freedom of positioning allows measuring whether the patient is sitting, standing, half-sitting or in the supine or lateral recumbent position.A high-visibility indicator at the probe base confirms your positioning of the tonometer prior to measurement. A green light indicates measurement will be reliable, a red light indicates incorrect positioning. Features:
- Effortless probe loading with the same probe as for the Icare TA01i and ic100 tonometers
- The probe can’t accidentally drop from the device
- Easy menu in many languages
- Wireless (Bluetooth) printing and measurement transfer - Revolutionary design to allow for positional freedom when taking IOP measurements
- Innovative automatic measuring sequence allows for 6 automatic measurements or single measurements to be taken with the same button
- Intelligent positioning system for correct alignment of the tonometer
- Powered by AA batteries
Specifications:
- Dimensions : 43mm[W] x 104mm[H] x 214mm[L]
- Weight : 165 g (without batteries), 260 g (with 4 x AA batteries)
- Power supply : 4 x AA non-rechargeable batteries, 1.5V alkaline LR6
- Measurement range : 7 - 50 mmHg
- Accuracy : ±1.2 mmHg (≤20 mmHg) and
: ±2.2 mmHg (>20 mmHg)
- Repeatability (coefficient of variation) : <8% Package Includes:
- Icare ic200 tonometer
- 4 x AA batteries
- Aluminum case
- IOP pad
- Probe base cover
- Quick guide
- Screw driver
- Silicone grip
- Spare probe base
- Instruction manual
- Warranty card
- Wrist strap |