| Description | Fluke Biomedical Prosim 8 Vital Signs & ECG Patient Simulator
Testing can be performed all day with a 9-hour battery life and test results can be saved in the simulator’s onboard memory. Best-in-class accuracy and measurement technology, including 50+ arrhythmia waveforms, also make it a welcomed addition to any Biomed’s tool bench. | Cutera Xeo LaserMultiple Technologies, Maximum FlexibilityIn today’s fast-paced aesthetic practices, maximum flexibility and upgradeability are paramount. Whatever your need, the Cutera Xeo Laser can provide the most versatile laser and light technologies on the market today. Whether you are interested in, Skin Fitness, hair removal, vascular therapies – or all the above – the Xeo can accommodate your specific needs through our upgradeable platform.The Cutera Xeo Laser combines the proven effectiveness of Cutera’s long-pulse Nd:YAG laser technology with the next generation of pulsed light treatments. The Cutera XEO can offer permanent hair reduction on all skin types, a complete range of vascular treatments and the next-generation in non-ablative combination skin therapy. | InMode Aesthetics InmodeRF BodyTite with BodyTite and FaceTite ApplicatorsBenefits
Controls heating to ensure that large volume contraction is consistent, avoiding overtreated or undertreated area
When treating different areas of the body, the operator is always receiving real time temperature monitoring, even in deep fat areas where laser temperature readers cannot reach
Allows focal treatment of all body areas with large volume
Treats deep fat, up to 50 mm (2 inches) | CIRRUS HD-OCT 5000 is configured with the highest resolution visualization capabilities and sophisticated clinical applications such as Advanced RPE analysis to track retinal pigment epithelial integrity and Ganglion Cell Analysis to assess glaucomatous loss in the macula that may not be evident in the peripapillary region. The new FastTrac retinal tracking reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning. This feature enables the highest resolution B-Scans to be captured in identical locations from visit to visit providing precise assessment of change in targeted pathologies. | The Extra – 818 is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features:
* Contemporary touch screen control
* Built-in Patch Test procedure for examining the optimal energy level
* A stunning number of 450,000 flashes in both lamps.
* The Large Handpiece has a Push Button in addition to the Foot Switch making
work easier and faster for the therapist. | Energist NeoGen PSR offers a range of treatment options, and delivers the unparalleled results your patients expect: The unique energy delivered by NeoGen is non fractionated and not dependant on a chromophore for its uptake. This provides uniform energy absorption, ensuring consistent treatment of the skin, and at high energies supporting significant tightening. |
| Content | ProSim 8 Vital Signs Patient Simulator + SpO2
The ProSim 8 Vital Signs Patient Monitor Simulator by Fluke Biomedical is an all-in-one, portable simulator featuring a user-friendly design that helps healthcare technology maintenance and clinical bioengineering departments to efficiently meet compliance needs by enabling preventive maintenance testing with a single device, reducing average test time by up to 88%.Designed to make comprehensive patient monitor testing quick and easy, the ProSim 8 tests eight vital sign parameters that are synchronized with one another, just as in the human body. It offers total patient monitor quality and safety testing, from non-invasive blood pressure (NIBP), static pressure linearity and dynamic pressure repeatability tests, EC13 and ACLS ECG waveforms, to complete Nellcor and Nonin SpO2 low perfusion and Masimo Rainbow SET, all in a single, 5-minute PM testing tool. While specialized, stay-connected ECG posts ensure secure lead connections. Fluke Biomedical’s ProSim 8 Vital Signs Patient Monitor Simulator
Wireless PC communication, customized presets, auto-sequences, barcode scanning, onboard memory, direct data capture, printing functions and single-step adjustability helps the ProSim 8 maximize testing productivity. Weighing in at a compact 4.2 lbs. (1.87 kg), it’s smaller and lighter than Fluke Biomedical’s previous generation of single function simulator test tools. And last, but certainly not least, a carrying case doubles as a mobile workstation.“At Fluke Biomedical, innovation doesn’t happen by accident. We dedicate unprecedented amounts of time and resources into extensive voice-of-customer research. This means we develop products based on the life of a biomed; their pain points, workarounds, routines, and goals,” company officials say. “We listen. Then, we take it a step further and work to design products that will grow and adapt to what they may need in the future.”Testing can be performed all day with a 9-hour battery life and test results can be saved in the simulator’s onboard memory. Best-in-class accuracy and measurement technology, including 50+ arrhythmia waveforms, also make it a welcomed addition to any Biomed’s tool bench.“One of the best things about this product is the finger-friendliness,” remarked one of the Fluke Biomedical customer design partners. “Where the connectors are, where the softkeys are—you made it small enough to be highly compact but big enough to allow for amazing manual dexterity. It’s not too big, it’s not too small—you got it just right.”Top Product Features ProSim 8 Vital Signs Patient Simulator + SpO2Some of the key benefits of the ProSim 8 Vital Signs Patient Monitor Simulator include:- An all-in-one patient simulator 80% smaller and 17 lbs./7.7 kilos lighter than single function simulator test tools
- 8-in-1 multifunction patient simulator: ECG, fetal, arrhythmia, respiration, temperature, IBP, cardiac output, cardiac catheterization
- SpO2 tester and premier SpO2 simulator to test Rainbow multi-wavelength waveforms
- Stay-connected ECG posts for lead connections
- Custom SpO2 r-curve for accurate testing of oximetry technologies
- Static pressure linearity testing
- Repeatable NIBP simulation for dynamic pressure repeatability testing
- Physiologically synchronized pulses across all parameters
- Barcode scanning and direct data capture and printing
- Onboard, customizable patient presets and auto sequences
- Multiple language user interface with language selection
- Integrated, long-life battery
- Optional PC-interface software with customizable procedures/checklists and automated data capture/storage
- Wireless, remote PC control of data transfer and automated regulatory reporting
| Cutera Xeo with Full Nd Yag and Low PulsesCutera Xeo Laser HandpiecesPearl Fractional Handpiece Features- Pearl Fractional has deep ablation and controlled thermal zone delivers maximum single-treatment results with less patient discomfort, downtime and risk than CO2
- Indicated for moderate to severe photoaging
- The 2790 nm wavelength (YSGG) controls thermal damage to maximize ablation while maintaining thermal stimulation and coagulation
- Controlled thermal zone minimizes risk of PIH and other complications
- Single treatment results are possible because our large 300 micron spot size ablates enough tissue in one pass
- Wound healing causes increased fibroblast activity and long term collagen deposition. Improvement is realized over six month period.
CoolGlide Nd Yag Laser Handpiece Features and SpecificationsThe CoolGlide laser is the first laser cleared for permanent hair reduction in all skin types.- Treat all skin types (I-VI) including tanned skin in the summer
- Patented PowerFlex™ technology provides fast treatments and high efficacy; allows independent control of fluence, pulse duration and repetition rates to tailor your treatment parameters
- Copper cooling provides the most efficient method of cooling for optimal skin protection and comfort
- Large spot size (10 mm) for maximum speed and optimal penetration at all follicle depths
- Wavelength: 1064 nm
- Fluence / Energy: Up to 300 J/cm2
- Spot Size: 3 mm, 5 mm, 7 mm, 10 mm
- Pulse Width: 0.1 – 30 msec or 10 – 100 msec
- Repetition Rate: 2 Hz to 10 Hz
Laser Genesis Handpiece FeaturesLaser Genesis is a staple of skin care for every doctor’s practice. It is a multi-purpose, all season, all skin type solution for overall skin health- Cutera Xeo Laser has a 1064 nm wavelength, combined with our patented microsecond technology, protects the epidermis, targets microvasculature and stimulates collagen production
- Improves wrinkles by gently heating the dermis; corrects diffuse redness, rosacea; smooths skin texture, shrinks pore size
- Peer reviewed journal shows evidence of erythema reduction and new collagen formation in the papillary dermis (Archives of Dermatology, Nov 2004)
- No downtime, minimal discomfort, no disposables.
LimeLight Handpiece Features and SpecificationsLimeLight is the most versatile, programmable device for treating vascular and pigmented lesions.- Three distinct preset programs (520-1100 nm) provide excellent hemoglobin and melanin absorption for uniform treatments and ease of use
- Clinical versatility permits treatment of multiple indications, including both low and high contrast pigmentation
- Features such as the industry’s fastest treatment speed and adjustable temperature control provide clinical versatility
- Only company with real-time calibration; this ensures accurate and consistent power output during treatment for reproducible results and patient safety
- Program A – 520 nm Filter – Fine Telangiectasia
- Program B – 560 nm Filter – Telangiectasia, Pigment
- Program C – 580 nm Filter – Solar Lentigines
- Spot Size: 10 mm x 30 mm
- Cooling: 5 °C, 10 °C or 20 °C
- Fluence / Energy: 5-30 J/cm2
- Repetition Rate: 2 Hz
AcuTip Handpiece FeaturesAcuTip delivers optimal results with targeted focal treatments of pigmented and vascular lesions–with no risk to surrounding skin.- Small tip allows aggressive pinpoint treatments – without compromising safety
- Selective wavelengths (500-635 nm) with short pulse durations deliver a powerful focal treatment
- Ideal for treatment of both low and high contrast pigmented lesions
- As powerful as Q-switched lasers for epidermal pigmentation; low risk of associated PIH
Pearl Handpiece FeaturesPearl delivers superior results in fewer treatments with less patient downtime than with non-fractional ablative lasers.- Indicated for fine wrinkles, dyschromia, skin tone and texture
- Full epidermal renewal is achieved with YSGG’s 2790 nm wavelength
- Patients receive 1-2 treatments without weeping and oozing and recover in 3-4 days
Excel Handpiece FeaturesThe first clinically effective long-pulsed Nd:YAG laser for both facial and lower extremity vascular lesions.- The Excel safely and effectively treats discrete vessels, high pressure vessels and deep veins
- Patented PowerFlex™ technology provides fast treatments and high efficacy; allows independent control of fluence, pulse duration and repetition rates to tailor your treatment parameters
- Contact copper cooling provides the most efficient method of cooling for optimal skin protection and comfort
- The “clearview” handpiece feature prevents vessel closure due to contact pressure
- Easy on-the-fly spot size adjustment (3, 5, 7 mm) facilitates optimal selection for safety and results
Titan V HP (small areas) + Titan XL HP (large areas) Handpieces Features and SpecificationsTitan is the most researched and peer-reviewed infra-red solution for deep dermal heating of all skin.- Titan’s light source generates energy from 1100 to 1800 nm for safe and effective volumetric heating of the dermis
- Titan candidates are often patients not yet ready for surgery
- When combined with other non-ablative procedures that improve conditions such as dyschromia, Titan’s toning effect enhances overall results
- Wavelength: 1100 – 1800 nm Infrared
- Fluence / Energy: 5 to 65 J/cm2
- Spot Size
- Titan V – 10 mm x 15 mm
- Titan XL – 10 mm x 30 mm
- Tx Cycle: 4 to 10 Seconds
ProWave Hair Removal Handpiece Features and SpecificationsProWave has multiple wavelength technology switches modes from Alexandrite to Diode to near Nd:YAG for maximum results, safety and versatility—all in a single high speed device.- ProWave (770-1100 nm), combines unrivaled treatment speed with optimal results and safety. Maximum versatility is achieved multiple wavelength technology enabling treatment modes from Alexandrite to Diode to near Nd:YAG
- Clinical studies showed > 80% hair reduction six months post three treatments
- Wavelength: 770 – 1100 nm
- Fluence: 5 to 35 J/cm2
- Spot Size: 10 mm x 30 mm
- Repetition Rate: 2 Hz
Cutera Xeo Laser System Specifications Cutera Xeo with Full Nd Yag and Low Pulses- Dimensions: 12″ W x 19″ D x 35″ H
- System Cooling: Internal, self-contained
- Electrical Info
- 115 V | 60 Hz | 20A
- 230 V | 60 Hz | 20A | 1 Phase
- Weight: 135 lbs
| INMODE Bodytite Laser – Radio Frequency (RF)BodyTite
Cannula Length:17 cm
Cannula Diameter:2.2 mm
Depth of Treatment:Up to 50 mm (2)
Internal Temperature:Operator adjustable between 50°C – 70°C
External Temperature:Operator adjustable up to 42°C
Output Temperature:1 MHz+
FaceTite
Cannula Length:10 cm
Cannula Diameter:1.3 mm
Depth of Treatment:Up to 25 mm (1″)
Internal Temperature:Operator adjustable between 50°C 70°C
External Temperature:Operator adjustable up to 42°C
Output Frequency:1 MHzBodyTite WorkstationMinimally Invasive Radio-Frequency Assisted Lipolysis (RFAL) Surgical Results Without the Scars.BodyTite is InModes latest minimally-invasive body contouring procedure that provides superior internal and external lipolysis, delivering results only achieved through more extensive excisional surgical procedures. BodyTite is powered by RFAL (Radio-Frequency Assisted Lipolysis) resulting in three-dimensional remodeling.BodyTite provides doctors with a tool to perform arm lifts without excisions, breast lifts without the lollipop scar and contour areas of non-adherence with results previously only achieved through more extensive surgical procedures.Benefits
Controls heating to ensure that large volume contraction is consistent, avoiding overtreated or undertreated area
When treating different areas of the body, the operator is always receiving real time temperature monitoring, even in deep fat areas where laser temperature readers cannot reach
Allows focal treatment of all body areas with large volume
Treats deep fat, up to 50 mm (2 inches)PATIENT BENEFITS
Patients today want to avoid surgery when possible. With BodyTite and FaceTite, your patients can reduce fat without leaving behind saggy, wrinkly skin. They are left with surgical-like results with no scars, less downtime and long-lasting, beautiful results.PRACTICE BENEFITS
Adopting RFAL with three-dimensional skin contraction can help innovate your practice. Leveraging BodyTite and FaceTite for your practice allows you to add a suite of minimally invasive procedures that contours and lifts abdominal, breast, face, neck, arm, thigh and knee tissue.FaceTite
HOW DOES IT WORK
FaceTite is a minimally-invasive contouring solution for the face and small areas of the body. Physicians can achieve results similar to a facelift or brachioplasty without excisional surgery. This is a safe, effective and exciting treatment that offers patients significant aesthetic changes.FaceTite is powered by RFAL (Radio-Frequency Assisted Lipolysis) and provides superior internal and external lipolysis, resulting in three-dimensional remodeling of the fibrous septa. Built-in safeguards including real time measurements of skin temperature, impedance monitoring, power cut-off and audible feedback help ensure patient safetyBenefits INMODE Bodytite Laser – Radio Frequency (RF)
Uniform thermal field provides an even distribution of heat.
Dual temperature technologies provide greater safety and control compared to other technologies.
100% energy concentration in the treatment zone.
Physician sets and controls the temperatures. Heat gradient enables optimal treatment results.AccuTite
ACCURACY IS EVERYTHING
PRECISION TARGETING AND PROVEN PERFORMANCE
ACCURACY IS EVERYTHING
The new AccuTite makes focal RF contraction without excisional surgery the new standard in cosmetic medicine. Small, but mighty, the AccuTite delivers precision heating in addition to the science and safety recognized with the Radio-Frequency Assisted Lipolysis (RFAL) family of technologies.
FOR FACE AND BODY
FACEBrow
Periorbital
Nasolabial Fold
Lower Face
Neck
BODYAxilla Bra Fat
Upper Arms
Hands
Abdomen Etching
Inner Thigh
Knees
Womens Health & WellnessSIMPLE, SAFE & FOCUSED
The AccuTite is the smallest minimally-invasive radio-frequency contraction device with the most number of clinical studies and peer-reviewed publications backing its safety and efficacy. Patients who need precision fat reduction or skin contraction now have a new solution that can be done under local anesthesia, in an office setting, in less than 20 minutes, without excisional surgery. | Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HDAdvancing Smart OCTfor Anterior Segment, Glaucoma and Retina- Anterior Segment Premier Module
- PanoMap Wide-Field Display
- Smart HD Scans
- En face report
Visualization at the speed of CIRRUSAnalyzing a single pathology from multiple views provides comprehensive insight and analysis of the clinical situation. How this helps you: - Spot small areas of pathology. Tightly spaced B-scans, (either 30 or 47 μm apart), in the cube ensure that small areas of pathology are imaged. For reference, a human hair is about 40-120 μm in diameter.
- Visualize the fovea. Scans that are spaced further apart than in the CIRRUS cube may miss the central fovea.
- Fuel for analysis. Millions of data points from the cube are fed into the Zeiss proprietary algorithms for accurate segmentation, reproducible measurements and registration for change analysis.
- Take the pressure off the operator. As long as the scan is placed in the vicinity of the fovea or optic nerve, the software automatically centers the measurements after the capture.
- See the tissue from different perspectives. View the cube data from all angles, with 3D rendering, OCT fundus images and Advanced Visualization™.
- Future ready. Previously captured CIRRUS cubes can be analyzed using new analyses.
Tracking at the speed of CIRRUSFastTrac™ reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning
With FastTrac, scan at the highest resolution at the same location at each visit. Assessment at the speed of CIRRUSMeasurement centering with FoveaFinder and AutoCenterOn the macula, the unique FoveaFinder technology ensures the ETDRS and ganglion cell plus inner plexiform layer measurement frameworks are centered on the fovea.AutoCenter™ function automatically centers the 3.4 mm diameter peripapillary RNFL calculation circle around the disc for precise placement and repeatable registration. The placement of the circle is not operator dependent. Accuracy, registration and reproducibility are assured. Manage at the speed of CIRRUS Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HDGuided Progression Analysis (GPA™) for Assessing RNFL and Optic Disc ChangeGPA™ compares RNFL thickness and optic disc measurements over time and determines if statistically significant change has occurred.Focal Progression Analysis – Up to 6 progression maps are compared to two baselines. Areas of statistically significant change are color-coded yellow when first noted and then red when the change is sustained over consecutive visits.
Trend Analysis with Rate of Change – RNFL thickness values are plotted over time. Trends are calculated and confidence intervals are shaded when rate of change is statistically significant.
| Active Optical Extra 818 IPL Skin Rejuvenation & Hair RemovalHandpieces:Integrated dual handpieces
Chilled Tip:Up to 4c
Pulse Interval:0.5-2 Seconds
Output Power:11-31 joulse/cm2, upto 4,000W
Cooling System:Revolutionary dual cooling
Control:Intuitive touch screen control
Lamp’s Life Span:250,000 Flashes (Universal) 200,000 Flashes (Facial)
Treatment Area:4.5 cm2 (15*50mm) Universal, 4.5 cm2 (15*30mm) Facial
Wavelength:420-100 nm
Weight:42Kg (including Stand)
Dimensions:44cm x 45cm x 100cmExtra-818 Active Optical Extra 818 IPL Skin Rejuvenation & Hair Removal
The Extra – 818 is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features:
* Contemporary touch screen control
* Built-in Patch Test procedure for examining the optimal energy level
* A stunning number of 450,000 flashes in both lamps.
* The Large Handpiece has a Push Button in addition to the Foot Switch making
work easier and faster for the therapist.The Extra – 818, based on Active’s GEM-PL technology, sets sets a specific Pulse Pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth.
The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.The combination of tested treatment protocols with high end engineering makes the Extra – 818 the perfect device for leading clinics.Revolutionary Cooling System
The Extra – 818 has a dual cooling system, controlled and monitored in order to ensure long lifetime to the lamp and a comfortable treatment to the patient.Competitive cooling systems “freeze” the skin so that during the treatment the skin temperature will rise to a bearable level. However, this “freezing” temperature might limit the results because the follicles will not reach the coagulation temperature. To ensure optimal results Active installed a special Processor that prevents overcooling the skin and maintains a uniform low temperature of the “glass” throughout the treatment. This revolutionary system enables the Extra – 818 to provide best results with optimal patient comfort.Research Program
For clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device.
The energy levels in the self setting program can reach 31Jcm2 with high intensity of 4,000W. | Energist NeoGen PSR LaserNeoGen PSR SystemNeoGen nitrogen plasma technology delivers controlled heating to the skin architecture stimulating a significant physiological response, without creating an open wound. Unlike ablative technologies there is no epidermal vaporisation or charring caused at time of treatment.
Unique TechnologyNeoGen converts nitrogen gas into plasma energy, the fourth state of matter. The plasma emerges from the handpiece in controlled pulses and rapid heating of tissue occurs as it gives up its unique thermal energy to tissue.
No Open WoundsThe treated photodamaged layers undergo a controlled thermal modification, while remaining intact, creating a natural dressing to provide protection and speed healing. at high energies the epidermis sheds, but only after a new, healthier skin architecture is formed beneath.
Treats the Whole Skin ArchitectureTreating the entire skin structure ensures optimal results as the entire surface is regenerated with associated neocollagenesis and neoelastogenesis. No islands of untreated skin remain. Clinical studies show significant tightening – Mean 22% improvement in upper eyelid tightening (JOCD 7, 169-179, 2008).
Eyelids and Periorbital TreatmentEnergist NeoGen PSR is the ideal option for the treatment of the upper and lower eyelids, as well as the wider periorbital region. Other technologies cannot be used in this area or deliver inconsistent results.
Long Lasting ResultsClinical studies show neocollagenesis and reduction in elastosis continuing for more than one year post treatment.The Proven Power of Plasma for Skin Regeneration Energist NeoGen PSR Laser• Unique technology – controlled pulses of nitrogen plasma energy
• Treats the whole skin architecture – no islands of untreated skin remain
• Deep Tissue Remodelling – epidermis acts as natural dressing post treatment
• Versatile – high or low energy treatment choices to fit your patients’ needs and lifestyle
• Precise – treat eyelids effectively with significant results
• Long-lasting effects – intense fibroblast activity supports continued regeneration.
• Consistent – non-fractionated and non-chromophore dependence assures uniform energy absorption
• Proven Plasma Skin Regeneration is supported by numerous IRB-controlled studies
TechnologyPlasma skin regeneration was introduced with a level of scientific and clinical testing never before seen in the industry:
• 3+ years of pre-clinical and clinical testing
• 16 separate studies
• more than 450 clinical study treatments –No scarring or Hypopigmentation noted in studies
• one year clinical histology
This level of testing is very rare in the industryEnergist NeoGen PSR uses a highly energized gaseous state known as plasma to produce a unique thermal profile to penetrate the superficial and deeper levels of the dermis to replace damaged collagen and encourage new collagen growth for new skin. Plasma is produced inside the handpiece through the combination of inert nitrogen gas and ultra-high frequency RF.The Energist NeoGen PSR is emitted in millisecond pulses; the longer the pulse, the more energy is delivered. Nitrogen molecules impact the skin’s surface and immediately transfer energy upon contact. When the nitrogen plasma impacts the skin surface, energy is immediately transferred to the tissue. Oxygen is purged from the skin surface by the plasma, preventing carbonisation. The energy delivered to tissue ranges from 1 – 4 Joules and is user-adjustable. The repetition rate of the plasma pulses can also be controlled, and ranges from 1 – 2.5 Hertz.Specifications Energist NeoGen PSR| Power: | 100 – 120 / 230 Vrms – 50/60 Hz – 650 Va | | Energy Output: | Pulsed nitrogen plasma – 1-4 Joules. | | Repetition Rate: | 1.0 – 2.5Hz | | Dimensions: | 470 x 430 x 1060mm | | Gas Requirement: | Medical Grade Nitrogen | | System Weight: | 18kg/40lb | | Trolley Weight: | 25kg/55lb (excludes gas tank) | | Ambient Environment: | 0 to 40 celsius | | Relative Humidity: | 30 to 75% | | atmospheric pressure: | 700 to 1600 hpa |
|
Reviews
There are no reviews yet.