| Description | Includes:
Blue LED Lamp
Revive (Red) Lamp
3 Patient Eyewear
Operators Manual
Power Cord | LOGIQ e Needle Recognition Software Option which helps provide precise and accurate display of the needle, anatomy and motion even in Color and Power Doppler. This feature harnesses pattern recognition technology that recognizes and accurately reveals the structure of a needle within the anatomy, without distortion of the needle and compromising the target. | Brand New Aesthetika Invikta 808nm Diode Laser for Hair Removal with Sapphire Dual Chill Tip and Large 12 x 16 mm Spot Size; Includes: Base Platform, 12 x 16 mm Diode Laser Handpiece with a One year, 20 million pulse warranty (whichever comes first), Operator Eyewear, Patient Eye Shields, User Manual, Clinical Workbook, Power Cord, Water Refill Kit, Training, 1 Year System Warranty and Free Shipping. | VISION MEDICAL SMARTGRAFT FUE HAIR TRANSPLANT SYSTEMInnovative Hair Transplant System for Men and Women
Developed by physicians, medical scientists, and engineers, SmartGraft uses the most innovative technology in advanced hair restoration for both men and women – SmartHarvest Technology. This allows the operator to harvest grafts more efficiently, safely, and quickly, while keeping grafts moist, chilled, and robust prior to implantation. It also allows the physician to harvest grafts from other parts of the body, such as the chest and face, for better results, and incorporates the most critical component of hair transplantation – the human artistry required for proper facial framing. | The Erchonia Zerona Cosmetic Laser model is designed for use during non-invasive body contouring. It is a body sculpting machine designed to remove fat and contour the body without the invasive surgery that many patients prefer not to go under.Zerona is the only clinically-proven non-invasive body contouring treatment, providing 6 quick & painless treatments. These treatments specifically target stubborn fat areas and painlessly emulsify the fat under your skin using the Lymphatic system. | ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER includes: Handpiece, Footswitch, Operator Eyewear, Patient Eyewear, Cart, Key, Operator Manual, ultrasound gel, replacement fuses, replacement filters |
| Content | OMNILUX PHOTODYNAMIC THERAPY LIGHT SOURCEOmniLux Photodynamic Therapy Light Source, which entails the use of a photosensitizing topical medication in conjunction with exposure to red or blue light as a treatment for acne, can be quite an effective treatment.
This procedure is a good alternative to many acne treatments to include isotretinoin. Accutane and oral antibiotics. Some researchers have shown it to have similar effectiveness to these more traditional treatments. This type of treatment generally requires multiple sessions to achieve such results.The advantages of Omnilux therapy- Stimulates the bodies own cellular mechanisms by photomodulation
- Not a laser or an IPL so no heat, no side effects or downtime
- Non-invasive, non-ablative safe therapy
- No damage to sub-dermal tissue
- Relaxing and calming experience
- Allows treatment of large areas such as the face and chest
- Simple to operate
- Economically viable
Includes:
Blue LED Lamp
Revive (Red) Lamp
3 Patient Eyewear
Operators Manual
Power CordThe Importance of Your Light Source for Photodynamic TherapyPhotodynamic therapy (PDT) has been used for a variety of dermatologic conditions for many years. In the United States, PDT is considered an effective first-line therapy for treatment of skin with actinic keratoses (AK). PDT is a common therapeutic option in dermatology practices. The most commonly used photosensitizer is aminolevulinic acid (ALA). Sold under several different brand names worldwide and a variety of formulations, ALA, and variations/derivatives, is considered today’s safest and most effective PDT photosensitizing drug. Mechanism of ActionConventional PDT for the treatment of AKs, and in Europe basal cell carcinoma (BCC) and nonmelanoma skin cancer, involves the photoactivation of protoporphyrin IX (PpIX). This occurs after prodrug ALA application and uptake, PpIX selectively accumulates in the atypical, dysplastic, or malignant cells. Upon illumination, photoactivation and photobleaching of PpIX occurs, generating oxidative stress and free radical reactive oxygen species (ROS). This initiates inflammation and ensuing cytotoxicity, resulting in preferential apoptosis and necrosis of abnormal cells.To generate a therapeutic effect, the spectral output of the light source should correspond to the excitation peaks of the photosensitizer. PpIX has 2 important therapeutic peaks, 404 to 420 nm in the violet-blue spectrum, and 633 nm in the red wavelength region. The depth of light penetration into the skin increases with longer wavelengths. Although blue light allows sufficient tissue penetration for the treatment of superficial AKs, red light penetrates much deeper into skin (up to 8-mm deep) and is more effective for the treatment of thicker lesions such as BCCs when combined with ALA.
BLUE LAMP SPECS
Power:40 mW/cm2
Wavelength:415 nm
Treatment Time:20 Minutes
Lamp Type:LED
Weight: 12 Kg
REVIVE (RED) LAMP SPECS
Power:40 mW/cm2
Wavelength:633 nm
Treatment Time:20 Minutes
Lamp Type:LED
Weight:12 KgOmniLux Photodynamic Therapy Light SourcePLUS (YELLOW) INFARED LAMP SPECS
Power:30 mW/cm2
Wavelength:830 nm
Treatment Time:20 Minutes
Lamp Type:LED
Weight:12 KgLED (Light Emitted Diodes) Photodynamic Therapy Light Source
Omnilux BLUE Lamp
Omnilux blue has been specifically developed to target the naturally occurring photosensitiser, Coproporphyrin III, found in P.acnes bacteria. Omnilux blue is the most potent blue light source in activating the target photosensitiser, producing singlet oxygen that leads to rapid eradication of the P.acnes bacteria. The output of Omnilux blue is also optimised to activate the photosenstiser 5-aminolaevulinic acid and is therefore ideally suited for the treatment of Actinic keratosis. Omnilux blue delivers 40mW/cm2 48J/ cm2.The clinician can control the area of illumination and can shape the light to the contour of the treatment area. Only this way can the entire treatment area receive the required dose of light for effective therapy.Omnilux REVIVE (RED) Lamp
Omnilux revive at 633nm is proven to stimulate cellular mechanisms responsible for tissue repair and regeneration. OmniluxTM systems ensure that the right light dose is always delivered to the tissue, the right wavelength is always used to successfully activate the target cells or light reactive substrates and the right intensity is always used to prevent inefficient tissue response. The adjustable LED panels mean that the whole treatment area can be bathed in pure red light to maximize treatment outcome.Omnilux PLUS (YELLOW) INFARED Lamp
Omnilux plus utilises the core technology developed by Photo Therapeutics Ltd and can be delivered from a standard medical base unit using the interchangeable treatment head.Omnilux plus is based on a matrix of Infra Red LEDs, which provide narrowband 830nm light. The individual LED cone angle and the spacing of the LEDs ensure uniformity of the beam for full coverage of the treatment area. For safety reasons, single LEDs of visible yellow light are located in the four corners of each array in order to determine if the head is lit.Omnilux plus is used for the purpose of skin rejuvenation in combination with Omnilux revive and also for wound healing. Work is also being carried out on its use for the temporary relief of minor muscle and joint pain, arthritis, muscle spasm, relieving stiffness, promoting the relaxation of muscle tissue and to temporarily increase local blood circulation where applied.The clinician can control the area of illumination and can shape the light to the contour of the treatment area. Only this way can the entire treatment area receive the required dose of light for effective therapy. | GE Logiq E R7 Portable Ultrasound Machine
The NextGen LOGIQ combines the high performance of a console system with the portability of a laptop. GE Healthcare’s compact system is designed for general imaging, musculoskeletal, anesthesiology, interventional, emergency, and critical care applications.It provides ultrasound imaging with precise anatomical detail at a variety of depths. The system includes innovative features that help simplify interventional procedures.LOGIQ e Needle Recognition Software Option which helps provide precise and accurate display of the needle, anatomy and motion even in Color and Power Doppler. This feature harnesses pattern recognition technology that recognizes and accurately reveals the structure of a needle within the anatomy, without distortion of the needle and compromising the target.Also includes the ability to adjust needle gain and angle.- Standard package includes AC power cord (USA)
- internet cord 3 meter in length CAT-5 type
- PC to HUB structure
- system software on USB
- Optional Function Key Label
- Ultrasound Transmission Gel .25L
- English Basic Service Manual CD and English User Guide and AIUM booklet.
The following scanning modes are included:- B-mode
- M-mode
- Anatomical M-mode
- Color flow mode
- Power Doppler imaging
- Pulsed wave Doppler and Ophthalmic
Features:The NextGen LOGIQ ecombines the high performance of a console system with the portability of a laptop. GE Healthcare’s compact system is designed for general imaging, musculoskeletal, anesthesiology, interventional, emergency, and critical care applications.Display Screen:- 15 in High-Resolution Color LCD
- Resolution: 1024 x 768
- Horizontal/Vertical viewing angle: +/-80 degree
- Brightness AdjustmentIntegrated Speakers
- Audio Volume Adjustment
- Interactive Dynamic Software Menu
Console Design:- Laptop Style
- Lithium Ion Battery
- Integrated Solid State Drive
- CPU – Intel Duo Core
- Operating System – Microsoft® Windows® 7
Console Interfaces:- DC Power Input
- USB 2.0 (3)
- LAN 10/100/1000 BaseT
- Docking Cart Connector
- HDMI
Standard Features:- Integrated Solid State Drive
- Automatic Optimization
- CrossXBeamTM
- Speckle Reduction Imaging (SRI-HD)
- Virtual Convex/Virtual Apex
- Fine Angle Steer
- HD Zoom (Write Zoom)
- Coded Harmonic Imaging (CHI)
- Raw Data Processing
- Quicksave
- On-board User Manual (Help)
- InSiteTM ExC capability
- Loop storage—from live scanning and from memory
- Patient Information Database
- Customizable User Interface
- Full M&A Calculation Package with Real Time Auto Doppler Calculations
- Vascular Calcs
- Cardiac Calcs
- OB Calcs and Tables
- Fetal Trending
- Multi Gestational Calcs
- Musculoskeletal and Hip Dysplasia Calcs
- Gynecological Calcs
- Urological Calcs
- Renal Calcs
- Small Parts Calcs
- Rheumatology Calcs
- Pediatric Calcs
- Report Writer Package
Software Options:- easy3D
- LOGIQ View
- Needle Recognition
- Stress Echo
- eSmart Trainer
- Auto IMT
- DICOM® 3.0 Connectivity/Encrypted DICOM
Specifications: Console Dimensions Height- 70 mm (2.75 in) console only
- 100 mm (3.94 in) with handle
Width- 295 mm (11.61 in) console only
- 343 mm (13.50 in) with handle
Length- 346 mm (13.62 in) console only
- 375mm (14.76 in) with handle
Weight with Battery: Approximately 5.2 Kg (11.5 lbs)Operator Keyboard- Alphanumeric Keyboard
- Ergonomic Hard Keys
- Backlight Keys
Display Screen- 15 in High-Resolution Color LCD
- Resolution: 1024 x 768
- Horizontal/Vertical viewing angle: +/-80 degree
- Brightness Adjustment
- Integrated Speakers
- Audio Volume Adjustment
- Interactive Dynamic Software Menu
Console Electrical Power- Voltage: 100-240 V AC
- Frequency: 50/60 Hz
- Power: Max. 130 VA
Applications:GE Logiq E R7 Portable Ultrasound Machine- Abdomen
- Cardiac
- Gynecology
- Musculoskeletal
- Obstetrical
- Nerve Block
- Pediatric
- Small Parts
- Urological
- Vascular
- Rheumatology
- Emergency Medicine
- Cardiac intra-operative
| Aesthetika Invikta 808nm Diode Laser Hair Removal (Brand New)Aesthetika Invikta 808nm Diode Laser for Hair Removal with Sapphire Dual Chill Tip and Large 12 x 16 mm Spot Size; Includes: Base Platform, 12 x 16 mm Diode Laser Handpiece with a One year, 20 million pulse warranty (whichever comes first), Operator Eyewear, Patient Eye Shields, User Manual, Clinical Workbook, Power Cord, Water Refill Kit, Training, 1 Year System Warranty and Free Shipping.The diode 800- 810 nm laser for hair removal has become the gold standard for treating all skin types. This wavelength has been used for hair removal for over 20 years and is a testament to its effectiveness and safety. It is the number one selling wavelength for hair removal in the world. There are a number of reasons why the Invikta should be considered for your practice. These reasons include:
The Aesthetika Invikta Diode (808 nm), FDA cleared for laser hair removal, is one of the most versatile lasers for hair removal because you can treat just about every patient that walks through your door regardless of skin color. This means turning fewer patients away and generating more revenue from every customer. - Effective Pain Free Hair Removal
Invikta’s hair removal method uses time-tested SHR (Super Hair Removal) technology to offer a simple, effective, and painless method for hair removal. The Invikta’s SHR method gradually heats and damages the hair follicles while sparing injury to the surrounding skin. By keeping the handpiece constantly in motion, it ensures complete coverage to the treated area and offers a very comfortable treatment solution to the patient. The Invikta pulses a very low fluence at high repetition rates (10 Pulses per second) and enables you to customize a hair removal strategy for each patient safely and reliably.
Offering a very large spot size of 12 x 16 mm, it allows the practitioner to effectively treat very large body areas in a short amount of time. Time is money with laser hair removal and the Invikta allows you to complete larger treatment areas 30% to 40% faster than more traditional laser technologies.
The Invkita diode laser comes with a number of quality features that make it very attractive to the aesthetic practice. Some of the following include:
Reliability and LongevityThe Diode bar stacks inside the Invikta handpiece are imported from Germany and allow us to warranty the handpiece for 20 million pulses or 2 years, whichever comes first. Fewer breakdowns and down-time mean higher productivity for your practice and greater revenue generation. Very ErgonomicThe ultra-light handpiece allows the practitioner to perform a series of procedures without causing any discomfort or fatigue.
Ultra-Chilled Sapphire Tip means greater comfort and safety for your patient. Keeping your patient comfortable and free from heat-related pain is critical to a successful treatment outcome. The chill tip on the diode handpiece keeps a frosty temperature of -2 degrees Celsius, thereby ensuring safety and comfort with no adverse reactions. No Recertification or Warranty Transfer FeesWe’ve discussed this before, but it’s worth mentioning again. Almost every manufacturer out there charges a recertification fee. At Aesthetic Partners USA, we don’t believe this practice is ethical. Period. It’s bad business for the customer and it devalues your equipment if you ever choose to sell it down the road. We’ve chosen only laser manufactures who don’t resort to such practices and we hope we start a positive trend in the aesthetic industry by reducing or eliminating these fees altogether. AffordabilityThe Invikta Diode Laser is more affordable than 80 to 90% of the other laser hair removal devices currently sold in the marketplace today. To make things even better, you don’t compromise quality by paying less. You only win by making your practice more profitable, which is the name of the game for any aesthetic practice. Aesthetika Invikta 808 nm Diode Laser Hair Removal (New)Please Contact Us for More Details! | Vision Medical Smartgraft FUE Hair Transplant
Vision Medical Smartgraft FUE Hair Transplant System
Harvest hair grafts more efficiently, safely, and quickly, while keeping grafts moist, chilled, and robust prior to hair implantation.Innovative Hair Transplant System for Men and Women
Developed by physicians, medical scientists, and engineers, SmartGraft uses the most innovative technology in advanced hair restoration for both men and women – SmartHarvest Technology. This allows the operator to harvest grafts more efficiently, safely, and quickly, while keeping grafts moist, chilled, and robust prior to implantation. It also allows the physician to harvest grafts from other parts of the body, such as the chest and face, for better results, and incorporates the most critical component of hair transplantation – the human artistry required for proper facial framing.The SmartGraft Advantage:
Minimally invasive, faster healing time with virtually no discomfort or interruption of lifestyle for your patients
Advanced harvesting method for shorter procedure times and fatigue
Ideal solutions for both men and women of all hair types
Natural looking results
Solutions for other permanent hair loss areas, such as the body, facial hair and eyebrows.How Does SmartGraft Work & Why Is It Better?
SmartGraft is the newest Follicular Unit Extraction (FUE) device on the market, allowing physicians to remove the hair follicular units with more precision and less trauma than any other method. SmartGraft works by gently removing the hair grafts with suction while storing them in a temperature-controlled environment where they are kept healthy and hydrated without additional manipulation. Many physicians prefer these optimal conditions for the best outcome for hair growth after the hair implantations. Only SmartGraft is fully programmable to manage the rapid removal and allow shorter transplantation times, allowing your patients to get back to their activities quickly.What is Follicular Unit Extraction Hair Transplantation?
FUE is a less invasive surgical procedure that removes individual hair follicles from the donner site, usually the back of the head, to areas of evident hair loss or thinning. A hairline is designed and individual grafts are placed to create the most natural appearance. Unlike prior methods, such as the strip method, SmartGraft does not leave visible scarring and delivers natural results with minimal discomfort or downtime. | Erchonia Zerona Z6 Laser
The Zerona Laser Can Non-Invasively Reduce Upper Arm CircumferenceThe Zerona laser showed significant effectiveness in treating upper arms in a recent 40 subject, double-blind, randomized sham controlled clinical study. Subjects in the study were strictly screened to only include males and females aged 18 to 65 who were willing to maintain a regular diet and exercise during the time of the study. The study excluded all patients with any confounding medical, surgical, or other problems.All subjects were treated with a total of six, painless 20-minute treatments with either the Zerona 635 nm low-level laser or a sham laser device over a 2 week period. Upon completion of the treatments and at two weeks post-treatment, the active treatment group showed approximately a 4 cm combined reduction in the bilateral circumference and the sham treatment group showed essentially no change. Additionally, in the active treatment group 60 percent of the subjects met the success criteria and experienced a combined arm circumference reduction of 1.25 cm or greater compared with 0 percent of the patients treated with a sham laser. All of the results were highly statistically significant. Both groups showed no change in body mass index (BMI).Using low level laser light, the Zerona laser creates a pore in fat cells and stimulates fat to leak out of the cell. The cell deflates, but is not destroyed, and the fat is naturally processed by the lymphatic system as waste. After six treatments, one every other day for two weeks, patients lose an average of 3.65 inches from their waists, hips and thighs without pain, side effects or downtime.
COLD LASER and LOW LEVEL LASER TREATMENT TECHNOLOGYErchonia Zerona Cosmetic Laser is the first non-invasive fat loss laser to effectively target excess fat without the negative side effects associated with surgical methods. Zerona utilizes the same cold laser technology developed by Erchonia, which has been shown to emulsify fat and allow it to move to the interstitial space.Although this technology was originally utilized to help assist tumescent liposuction procedures, it was found that the cold laser treatment alone helped clients to reduce inches from their waist, hips, thighs, arms, chest, knees, ankles and back or bra fat thus creating overall body slimming effect.The research represented below was done in the US using an Erchonia laser and shows time released photography of one fat cell and its contents being emptied. Please note the cell is still alive. Erchonia uses only its own research to prove its patent and pending applications.
Erchonia Zerona Cosmetic Laser AdvantagesNo pain, no downtime and no risk
Proven effective
Superior treatment area coverageErchonia Zerona Cosmetic Laser Specifications Erchonia Zerona Z6 LaserUnit Status: This Unit is unlocked
Chassis: Power Coated metal frame for ease of cleaning.
Housing: Thermoformed of Non-allergen material / plastic
Accessories: 2 Keys, Laser Safety Glasses
Configuration: 5 – 3b Line Generated Laser Diode Modules
Wavelength: 635 nm
Modulation: Constant Wave (CW) – 1 MHz
Programming: 5 time-saving presets
Display: 8″ Full Color TFT Touch Screen
Electrical Info: 100-240 V (AC), 50-60 Hz
Dimensions: 49″ x 32″ x 57″
Weight: 266 lbs | Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERr uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IActive Optical Systems Optima 518 IPL LaserOptima-518-Classic
The Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERNew Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. |