| Description | NOMAD Pro 2 is designed with safety as the number one priority. The external backscatter shield and internal radiation shielding are specially designed to protect the operator from radiation exposure. In fact, the exposure from using NOMAD Pro 2 is less than one percent of allowed occupational doses. | Dynamis Pro Laser – XS Line
The Fotona XS Dynamis is a fully customisable Er:YAG laser (erbium) which represents a complete rejuvenation and resurfacing solution. It has a range of modes to allow alteration of the depth of laser peels; as well as offering, non-ablative treatments, ablative treatments and fractional treatments. | This system allows not only a quantitative nutational infrasonic infiltration, but also a nutational infrasonic liposculpture.Manufactured for a safe liposculpture respecting the non-fatty tissues. | New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort. | Energist NeoGen PSR offers a range of treatment options, and delivers the unparalleled results your patients expect: The unique energy delivered by NeoGen is non fractionated and not dependant on a chromophore for its uptake. This provides uniform energy absorption, ensuring consistent treatment of the skin, and at high energies supporting significant tightening. | CIRRUS HD-OCT 5000 is configured with the highest resolution visualization capabilities and sophisticated clinical applications such as Advanced RPE analysis to track retinal pigment epithelial integrity and Ganglion Cell Analysis to assess glaucomatous loss in the macula that may not be evident in the peripapillary region. The new FastTrac retinal tracking reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning. This feature enables the highest resolution B-Scans to be captured in identical locations from visit to visit providing precise assessment of change in targeted pathologies. |
| Content | NOMAD Pro2 Handheld Portable Dental X-Ray AribexNOMAD Pro2 Handheld Portable Dental X-Ray
• Entire unit weighs just over five pounds
• Handheld and portable design moves from room to room, eliminating the need for multiple units
• Perfect for use with children and special needs patients
• Ideal for clinical, hospital, home-health, nursing home, and out-of-office use
• Includes a one-year product warrantyModern Radiation Shielding
The external backscatter shield and internal radiation shielding are specially designed to protect the operator from radiation exposure. In fact, the exposure from using the NOMAD Pro is less than 1% of allowed occupational doses.Time Savings NOMAD Pro2 Handheld Portable Dental X-Ray Aribex
The NOMAD Pro color LCD screen, simple touch controls, and handheld design saves time.• Handheld design allows operator to stay with the patient, thereby reducing time required for X-ray procedures
• Quickly adjust exposure time with simple controls
• Ability to save custom exposure settings for fast recall
• Icons quickly identify tooth, receptor, and patient typeClear Images
The NOMAD Pro produces the highest quality images.• No blur from hand movement
• 0.4 mm focal spot produces sharp, high resolution images
• High-frequency, 60kV DC X-ray generator produces clear images while reducing patient doseWeight: 4.6 lbThe NOMAD Pro 2, now part of the trusted brand of KaVo, provides reliability and efficiency for busy dental offices as well as powerful freedom in workflow that is unattainable with wall-mount units. While the unit allows for the operator to move freely between operatories, it also helps with fearful or challenging patients since the assistant can stay in the room during the radiographic process.The most succinct diagnosis starts with the best image quality. NOMAD Pro 2 utilizes the latest in X-ray technology for precise, repeatable exposures that help to produce sharp, clear radiographic images. And the best part is that all of the benefits of this handheld unit can be attained with an eye on ALARA. With its intuitive user interface, the team member can select the right dose for each patient’s particular need.The unique, lead-infused acrylic shield protects the operator from direct and scatter radiation, and the internal proprietary housing encases the X-ray tube to block radiation leakage. When the KaVo NOMAD Pro 2 is used as directed, these shields create a “safe zone” for the operator throughout the acquisition process. | Fotona XS Dynamis Pro Multi-Application LaserOVERVIEWTechnology for Next Generation Resurfacing
With advanced treatment attributes and fully customizable settings, Fotona’s XS Dynamis offers true 3rd generation Er:YAG laser skin resurfacing. The XS Dynamis represents a complete rejuvenation solution. Its functions range from superficial to deep peels, from non-ablative to fully ablative and from full-field to fractional resurfacing. Resurfacing has Never Been as VersatileWith the XS Dynamis you can be your own artist; reverse the effects of aging and give skin a healthy, young look and feel. Over 20 treatment pre-sets can be accessed and further fine-tuned using digital ablation and coagulation depth indicators to gain predictable outcomes – one of the system’s strongest points. Complete ablation and coagulation control enables treatments to be tailored to each specific skin condition to achieve perfect results in both full-field and fractional resurfacing. The XS Dynamis can even be used with laser scar revision treatments. Acne scars in particular respond well to gentle Er:YAG laser resurfacing. Perfect for Pigmented Lesions Fotona XS Dynamis Pro Multi-Application LaserIn addition to skin resurfacing, the XS Dynamis’ high-performance Er:YAG laser is well equipped to handle a range of other applications in aesthetics and dermatology. The XS Dynamis can safely and effectively remove pigmented lesions like keratoses and moles through gentle ablation of the epidermis and superficial dermis in a controlled and relatively bloodless manner. Clinical studies have shown that Er:YAG lasers are very effective for the treatment of keratoses, with a clinical and histological improvement of up to 93% after just a single treatment. A Star Performer in GynecologyFotona’s Er:YAG laser wavelength is also highly useful for the treatment of lesions of the uterine neck and vagina, as well as HPV lesions, pigmentations and neoplasias. The XS Dynamis offers many benefits in gynecological treatments, including non-invasive, high-precision procedures with little or no pain, and often without anesthesia. Because of its non-contact, sterilizing capability it can even be used on infected tissue, with total re-epithelization and fast wound healing. | Euromi Eva SP7 Lipomatic Liposuction Unit{tab System composition}- 15-inch touch screen that can be angled from 0 to 45 degrees
- Excellent visibility for the surgeon during the procedure
- Control panel with touch screen allowing the infiltrated and aspirated zones to be visualized
- Control of the volume infiltrated and aspirated millimeter per millimeter in the zone selected on the touch screen
- The n.i.l technique ensures an homogeneous infiltration with a constant pressure, whatever the fat density
- Infiltration and aspiration data recording on USB flash memory
- Compatible with the lipofilling material n.l.f System 1 & 2
- In compliance with the European standards – CE marking
{tab Advantages}- Preservation of non-fatty tissues
- Very easy to change zones thanks to the mapping of the different zones on the touch screen
- Shorter post-procedure recovery
- Less traumatising (fewer hematomas and major reduction of ecchymosis and oedemas)
- Less painful for the patient
- Infrasonic frequency (25 Hz) comfortable for the patient
{tab Accessories} Euromi Eva SP7 Lipomatic Liposuction Unit- Evamatic/evamatic
- Control panel with touchscreen
- Quantitative infiltration system
- High-speed aspirator
- Complete set of cannulas
- Accessories
The Eva sp 7 allows a quantitative nutational infrasonic infiltration and also a nutational infrasonic liposculpture.Manufactured for a safe liposculpture respecting the non-fatty tissues, the system is entirely digitalizedIt complies with European standards (CE marking) and is compatible with N.L.F. System, our kit for lipofilling.This product is a medical device intended for use by qualified healthcare professionals.If you are a healthcare professional and would like more information about this product, please complete the form opposite.If you are an individual, for more information, please refer to your healthcare professional.Special features of Eva sp 7:- The screen provides excellent visibility for the surgeon during the procedure: infiltrated and aspirated areas.
- In addition, changing zones is very easy thanks to the mapping of the different zones on the touch screen. This screen allows you to control the volume infiltrated ml / ml in the zone selected on it.
- Infiltration and aspiration data can be saved on a USB drive.
| Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
The Laser uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IOptima-518-Classic Active Optical Systems Optima 518 IPL LaserThe Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. | Energist NeoGen PSR LaserNeoGen PSR SystemNeoGen nitrogen plasma technology delivers controlled heating to the skin architecture stimulating a significant physiological response, without creating an open wound. Unlike ablative technologies there is no epidermal vaporisation or charring caused at time of treatment.
Unique TechnologyNeoGen converts nitrogen gas into plasma energy, the fourth state of matter. The plasma emerges from the handpiece in controlled pulses and rapid heating of tissue occurs as it gives up its unique thermal energy to tissue.
No Open WoundsThe treated photodamaged layers undergo a controlled thermal modification, while remaining intact, creating a natural dressing to provide protection and speed healing. at high energies the epidermis sheds, but only after a new, healthier skin architecture is formed beneath.
Treats the Whole Skin ArchitectureTreating the entire skin structure ensures optimal results as the entire surface is regenerated with associated neocollagenesis and neoelastogenesis. No islands of untreated skin remain. Clinical studies show significant tightening – Mean 22% improvement in upper eyelid tightening (JOCD 7, 169-179, 2008).
Eyelids and Periorbital TreatmentEnergist NeoGen PSR is the ideal option for the treatment of the upper and lower eyelids, as well as the wider periorbital region. Other technologies cannot be used in this area or deliver inconsistent results.
Long Lasting ResultsClinical studies show neocollagenesis and reduction in elastosis continuing for more than one year post treatment.The Proven Power of Plasma for Skin Regeneration Energist NeoGen PSR Laser• Unique technology – controlled pulses of nitrogen plasma energy
• Treats the whole skin architecture – no islands of untreated skin remain
• Deep Tissue Remodelling – epidermis acts as natural dressing post treatment
• Versatile – high or low energy treatment choices to fit your patients’ needs and lifestyle
• Precise – treat eyelids effectively with significant results
• Long-lasting effects – intense fibroblast activity supports continued regeneration.
• Consistent – non-fractionated and non-chromophore dependence assures uniform energy absorption
• Proven Plasma Skin Regeneration is supported by numerous IRB-controlled studies
TechnologyPlasma skin regeneration was introduced with a level of scientific and clinical testing never before seen in the industry:
• 3+ years of pre-clinical and clinical testing
• 16 separate studies
• more than 450 clinical study treatments –No scarring or Hypopigmentation noted in studies
• one year clinical histology
This level of testing is very rare in the industryEnergist NeoGen PSR uses a highly energized gaseous state known as plasma to produce a unique thermal profile to penetrate the superficial and deeper levels of the dermis to replace damaged collagen and encourage new collagen growth for new skin. Plasma is produced inside the handpiece through the combination of inert nitrogen gas and ultra-high frequency RF.The Energist NeoGen PSR is emitted in millisecond pulses; the longer the pulse, the more energy is delivered. Nitrogen molecules impact the skin’s surface and immediately transfer energy upon contact. When the nitrogen plasma impacts the skin surface, energy is immediately transferred to the tissue. Oxygen is purged from the skin surface by the plasma, preventing carbonisation. The energy delivered to tissue ranges from 1 – 4 Joules and is user-adjustable. The repetition rate of the plasma pulses can also be controlled, and ranges from 1 – 2.5 Hertz.Specifications Energist NeoGen PSR| Power: | 100 – 120 / 230 Vrms – 50/60 Hz – 650 Va | | Energy Output: | Pulsed nitrogen plasma – 1-4 Joules. | | Repetition Rate: | 1.0 – 2.5Hz | | Dimensions: | 470 x 430 x 1060mm | | Gas Requirement: | Medical Grade Nitrogen | | System Weight: | 18kg/40lb | | Trolley Weight: | 25kg/55lb (excludes gas tank) | | Ambient Environment: | 0 to 40 celsius | | Relative Humidity: | 30 to 75% | | atmospheric pressure: | 700 to 1600 hpa |
| Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HDAdvancing Smart OCTfor Anterior Segment, Glaucoma and Retina- Anterior Segment Premier Module
- PanoMap Wide-Field Display
- Smart HD Scans
- En face report
Visualization at the speed of CIRRUSAnalyzing a single pathology from multiple views provides comprehensive insight and analysis of the clinical situation. How this helps you: - Spot small areas of pathology. Tightly spaced B-scans, (either 30 or 47 μm apart), in the cube ensure that small areas of pathology are imaged. For reference, a human hair is about 40-120 μm in diameter.
- Visualize the fovea. Scans that are spaced further apart than in the CIRRUS cube may miss the central fovea.
- Fuel for analysis. Millions of data points from the cube are fed into the Zeiss proprietary algorithms for accurate segmentation, reproducible measurements and registration for change analysis.
- Take the pressure off the operator. As long as the scan is placed in the vicinity of the fovea or optic nerve, the software automatically centers the measurements after the capture.
- See the tissue from different perspectives. View the cube data from all angles, with 3D rendering, OCT fundus images and Advanced Visualization™.
- Future ready. Previously captured CIRRUS cubes can be analyzed using new analyses.
Tracking at the speed of CIRRUSFastTrac™ reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning
With FastTrac, scan at the highest resolution at the same location at each visit. Assessment at the speed of CIRRUSMeasurement centering with FoveaFinder and AutoCenterOn the macula, the unique FoveaFinder technology ensures the ETDRS and ganglion cell plus inner plexiform layer measurement frameworks are centered on the fovea.AutoCenter™ function automatically centers the 3.4 mm diameter peripapillary RNFL calculation circle around the disc for precise placement and repeatable registration. The placement of the circle is not operator dependent. Accuracy, registration and reproducibility are assured. Manage at the speed of CIRRUS Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HDGuided Progression Analysis (GPA™) for Assessing RNFL and Optic Disc ChangeGPA™ compares RNFL thickness and optic disc measurements over time and determines if statistically significant change has occurred.Focal Progression Analysis – Up to 6 progression maps are compared to two baselines. Areas of statistically significant change are color-coded yellow when first noted and then red when the change is sustained over consecutive visits.
Trend Analysis with Rate of Change – RNFL thickness values are plotted over time. Trends are calculated and confidence intervals are shaded when rate of change is statistically significant.
|
Reviews
There are no reviews yet.